• 제목/요약/키워드: Wavy film

검색결과 30건 처리시간 0.026초

나노인덴테이션과 주사탐침현미경을 이용한 박막 재료의 특성평가 (Characterization of Thin Film Materials by Nanoindentation and Scanning Probe Microscopy)

  • 김봉섭;윤존도;김종국
    • 한국재료학회지
    • /
    • 제13권9호
    • /
    • pp.606-612
    • /
    • 2003
  • Surface and mechanical properties of thin films with submicron thickness was characterized by nanoindentation with Berkovich and Vickers tips, and scanning probe microscopy. Nanoindention was made in a depth range of 15 to 200 nm from the surface by applying tiny force in a range from 150 to $9,000 \mu$N. Stiffness, contact area, hardness, and elastic modulus were determined from the force-displacement curve obtained. Reliability was first tested by using fused quartz, a standard sample. Elastic modulus and hardness values of fused quartz measured were the same as those reported in the literature within two percent of error. Mechanical properties of ITO thin film were characterized in a depth range of 15∼200nm. As indentation depth increased, elastic modulus and hardness decreased by substrate effect. Ion beam deposited DLC thin films were indented in a depth range of 40∼50 nm. The results showed that the DLC thin film using benzene and bias voltage 0∼-50 V has elastic modulus and hardness value of 132 and 18 GPa respectively. Pure DLC thin films showed roughnesses lower than 0.25 nm, but silicon-added DLC thin films showed much higher roughness values, and the wavy surface morphology.

나노스케일 박막의 표면주름 형성을 통한 산란반사도 향상 (Diffuse Reflectance Enhancement through Wrinkling of Nanoscale Thin Films)

  • 김윤영
    • 대한기계학회논문집A
    • /
    • 제39권12호
    • /
    • pp.1245-1249
    • /
    • 2015
  • 본 연구에서는 나노스케일 박막의 표면주름 형성에 의한 산란반사도 향상을 평가하였다. 실리콘 기판 위에 120 nm 두께의 Poly(methyl metacrylate) 층을 스핀코팅(spin-coating)한 후, 20 nm 의 알루미늄 박막을 증착하여 시편을 제작하였다. 이를 오븐에서 $95^{\circ}C$의 온도로 2 시간 동안 풀림처리하여 표면주름을 형성하였다. 분광광도계로 가시광선 영역의 산란반사도를 측정한 결과 400 nm 파장에서 40%의 증가를 보였으며, 표면주름 위에 100 nm 의 은박막을 추가적으로 증착한 경우 산란반사도가 50%까지 향상되는 것을 확인하였다. 본 연구는 산란반사도의 증대를 요구하는 박막형 소자에 표면주름을 활할 수 있음을 제시한다.

Nucleation and Growth of b-Axis Oriented $PrBa_2Cu_3O_{7-x}$ Thin Films on $LaSrGaO_4$ (100) Substrates

  • Sung, Gun-Yong;Suh, Jeong-Dae
    • ETRI Journal
    • /
    • 제18권4호
    • /
    • pp.339-346
    • /
    • 1997
  • Good quality a-axis oriented thin films of $YBa_2Cu_3O_{7-x}$ may be grown by the use of a $PrBa_2Cu_3O_{7-x}$ (PBCO) layer as a template. Here we present a detailed study of the nucleation of the PBCO layer, explaining the orientations observed. It is determined that the wavy surface of a $LaSrGaO_4$ (LSGO) (100) substrate consists of the {101} planes by observing cross-sectional transmission electron microscopy images of the interface between the PBCO film and the substrate. The images and selected area diffraction patterns show that a mixed c-and b-axis oriented PBCO layer was initially grown on the substrate, followed by pure b-axis oriented PBCO growth. We explain that the c-axis oriented growth is the result of the growth of the PBCO (019) planes on the LSGO (101) planes. We conclude that the nucleation and growth of the PBCO films at the initial stages depends on the crystallographic plane of the substrate surfaces, however, as the film grows further, the kinetics of the deposition process favors b-axis oriented growth.

  • PDF

수평 냉각관 외부를 흘러내리는 $LiBr-H_2O$ 수용액의 유동 및 열/물질 전달 특성에 관한 실험적 연구 (An Experimental Study on Flow and Heat / Mass Transfer Characteristics of $LiBr-H_2O$ Solution Flowing over a Cooled Horizontal Tube)

  • 설신수;이상용
    • 대한기계학회논문집B
    • /
    • 제24권8호
    • /
    • pp.1085-1096
    • /
    • 2000
  • An experimental study was performed to examine the heat and mass transfer characteristics of $LiBr-H_2O$ solution flowing over a single horizontal tube with the water vapor absorption. Effects of the flow rate and the temperature of the solution at the top of the tube, the absorber pressure and the drainage pattern were considered. The absorption rate depends highly on the absorber pressure at the low flow rate condition while on the solution inlet temperature at the high flow rate condition. Also, when the flow rate is low, the absorption performance with the sheet flow drainage appeared to be higher than that with the dripping/jet drainage. However, at the high flow rate condition, the case became reversed. The liquid film became wavy with the higher absorption rate. The waves were more probable to form with the lower flow rate and temperature of the solution, and with the higher absorber pressure.

흡수식 열펌프용 공냉식 응축기의 성능특성에 관한 시뮬레이션 (Computer Simulation on the Performance of Air-Cooled Condenser for an Absorption Heat Pump)

  • 박윤철;민만기
    • 대한기계학회논문집
    • /
    • 제19권8호
    • /
    • pp.1999-2011
    • /
    • 1995
  • Computer simulation was conducted to study performance characteristics of air-cooled condenser of a double effect absorption heat pump with variations of saturation pressures and mass flow rates of the refrigerant ; volume flow rates, relative humidities and temperatures of the air The vertically installed condenser had the staggered tube array with continuous plate fins of wavy type. When the saturation pressure of the condenser was decreased from 760 torr to 20 torr, heat transfer rates and condensing rates of refrigerant were decreased. If excess refrigerant flows in the condenser, the pressure and saturation temperature of the condenser were increased which makes the refrigerating capacity of an absorption heat pump reduced.

Wave가 있는 원판형 추력베어링의 윤활특성 (Lubrication Characteristic of a Disk Type Wave Thrust Bearing)

  • 박태조;제태진;이운섭
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2002년도 추계학술대회 논문집
    • /
    • pp.888-891
    • /
    • 2002
  • This paper presents the lubrication characteristics of a disk type wavy thrust bearing. The hydrodynamic pressure distributions in the fluid film are numerically solved the Reynolds equation and then the bearing load capacity and friction forces acting on the disk are calculated. Especially the effects of number and amplitude of the circumferential waves are investigated for tilted operating conditions. The results showed that the load capacity increases with wave amplitude and optimum wave number exists for given design conditions. Therefore the results can be applied to enhance the lubrication performance of thrust bearing adopted in the scroll compressor.

  • PDF

파형이 있는 슬라이더 베어링의 윤활효과 (Lubrication effect of slider bearing with wavy surface)

  • 왕일군;진도훈;윤문철
    • 한국기계가공학회지
    • /
    • 제13권5호
    • /
    • pp.35-42
    • /
    • 2014
  • The influence of sine wave striated surface roughness on load carrying capacity of a bearing is studied for thin film effect of slider bearing. A Reynolds equation appropriate for slider bearing is used in this paper for analysis and it is discussed using finite difference method of central difference scheme. For a slider bearing with sine wave simple roughness form, several parameters such as pressure, load capacity and shear stress of the bearing can be obtained and also this results can be stored in sequential data file for latter analysis. After all, their distribution can be displayed and analyzed easily by using the matlab GUI technique. The parameters such as amplitude, number of waviness and slope of the surface are used for discussing the load carrying capacity of the rectangular bearing. The results reported in this paper should be applied to the other slider bearing such as rectangular or round embossed surface of slider bearing.

수직형 흡수기 최적화에 따른 흡수 성능 예측에 관한 연구 (Study on the Prediction of Absorption Performance by the Optimization of a Vertical Absorber)

  • 김정국;조금남
    • 에너지공학
    • /
    • 제14권3호
    • /
    • pp.194-202
    • /
    • 2005
  • 본 연구는 다양한 수직 액막형 흡수기에서 열 및 물질전달 과정에 따른 흡수 특성 예측을 이론 및 실험적으로 수행하였다. 열 및 물질전달 향상은 해석적으로 조사되었으며, 흡수 성능에 대한 유동 형태, 삽입기구 및 주름에 의한 형상 변수의 영향 등을 조사하였다. 특히, 최대 흡수 성능에 대한 동적 변수(수용액 유량, 유동형태)와 흡수기 형상(ID=22.8mm, L=1150m)의 최적값을 수치 해석적으로 예측하였다 수치 해석 및 실험에서 최대 흡수 성능은 삽입기구(스프링)에 의한 파동 유동에서 나타났다.

관내 응축 시 2상유동 단면구조의 가시화 (Visualization of cross-sectional two-phase flow structure during in-tube condensation)

  • ;김형대
    • 한국가시화정보학회지
    • /
    • 제14권2호
    • /
    • pp.18-24
    • /
    • 2016
  • This paper presents an experimental investigation to visualize cross-sectional two-phase flow structure and identify liquid-gas interface for condensation of steam at a low mass flux in a slightly inclined tube using the axial-viewing technique, which permits to look directly into flow during condensation of steam. In this technique, two-phase flow is viewed along the axis of a pipe by locating a high-speed video camera in front of a viewer that is fitted at the outlet of the pipe. A short section of the pipe is illuminated and is recorded through the viewer, which is kept free of liquid by mildly introducing air. Experiments were conducted in a pipe of 19.05 mm in inner diameter at atmospheric pressure. Cross-sectional two-phase flow structure is obtained at a steam mass flux of $2.62kg/m^2s$ as a function of steam quality in the range from 0.5 to 0.9. The results show that stratified-wavy flow is a unique flow pattern observed in the scope of the present study. Condensate film thickness, stratification angle and void fraction were measured from the obtained flow structure images. Finally, heat transfer coefficient was calculated using the measurement data and discussed in comparison with existing correlations.

An Intraosseous Schwannoma Combined with a Subchondral Fracture of the Femoral Head: a Case Report and Literature Review

  • Kim, Hyun Young;Ryu, Kyung Nam;Park, Yong Koo;Han, Jung Soo;Park, Ji Seon
    • Investigative Magnetic Resonance Imaging
    • /
    • 제21권3호
    • /
    • pp.177-182
    • /
    • 2017
  • Schwannomas are benign nerve sheath tumors that are typically located in soft tissue. Occasionally, schwannomas involve osseous structures. These intraosseous schwannomas are generally benign neoplasms that account for less than 0.2% of primary bone tumors. Schwannomas are very rarely observed in long bones. We present a case of a schwannoma affecting the proximal femur with a coincident subchondral fracture of the femoral head. A 38-year-old-male presented with left hip pain without deteriorating locomotor function. Plain film radiographs displayed a lobulating contoured lesion within the intertrochanteric portion of the femur. The magnetic resonance imaging (MRI) scans showed a tumor occupying the intertrochanteric region. Diffuse bone marrow edema, especially in the subchondral and head portions of the femur that was possibly due to the subchondral insufficiency fracture was also noted. The lesion was surgically excised and bone grafting was performed. Histologically, there was diffuse infiltrative growth of the elongated, wavy, and tapered cells with collagen fibers, which are findings that are characteristic of intraosseous schwannoma. Although very rare, intraosseous schwannoma should be included in the differential diagnosis of radiographically benign-appearing, non-aggressive lesions arising in the femur. The concomitant subchondral fracture of the femoral head confounded the correct diagnosis of intraosseous schwannoma in this case.