• Title/Summary/Keyword: Water-retention capacity

Search Result 206, Processing Time 0.022 seconds

Flour Quality Characteristics of Korean Waxy Wheat Lines

  • Hong, Byung-Hee;Park, Chul-Soo;Baik, Byung-Kee;Ha, Yong-Woong
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.46 no.5
    • /
    • pp.360-366
    • /
    • 2001
  • Flour physicochemical properties of six Korean waxy wheat lines and their parental plants, including Kanto 107 and BaiHuo, which have partially null in GBSS (granule bound starch synthase), were evaluated in this study. The very low amylose content (3.20%) of Korean waxy wheat lines, which had been influenced by the null in all three GBSS isoforms encoded by three Wx loci, could result in the higher starch swelling power (25.15%), lower starch and flour pasting temperature (61.37$^{\circ}C$; 65.85$^{\circ}C$), and higher starch pasting peak viscosity and breakdown (246.60 RVU; 161.50 RVU) than those of their parental plants. In addition to high swelling and pasting properties, Korean waxy wheat lines had the higher protein content (12.80%), alkaline water retention capacity (97.39%), SDS sedimentation volume (80.33 $m\ell$) and damaged starch content (4.35 %) than those of their parental plants.

  • PDF

Oil Absorption Effects of Organic Porous Materials (유기 다공성 소재의 흡유 효과)

  • Kang, Young-Goo;Han, Sang-Bum
    • Journal of the Korean Society of Safety
    • /
    • v.21 no.1 s.73
    • /
    • pp.86-91
    • /
    • 2006
  • Oil spills caused by the accidents have been occurred from house and factory waste, grounded tanker, the rupture of storage tank and oil pipelines, the deterioration of various industrial facilities, etc. Many oil spills result in contamination of shorelines and workplace. Fire and explosion may happen from these spills. There are several technologies used for clean-up application, which include use of oil dispersing agents, absorbents, solidifiers, booms and skimmers by physical, chemical, and biological methods. Methods for oil spill clean-up operation are classified into the absorption type, gel type and self-swelling type. Porous materials with oil absorptive properties are classified into micropore, mesopore, and macropore depending on their pore sizes. Recently, new porous materials with smaller size have been developed, but the selective oil absorption in water-in-oil interface demonstrates the macro pore size. In this study oil absorption effects were evaluated using the organic porous materials with a complex function of gel type and swelling type. Samples were subjected to analysis by FT-IR spectroscopy and were characterized in terms of gel formation and morphologies. Oil sorption capacity, pressure retention force and gel strength were also measured. From these results, the physicochemical reactivity before and after gelation was verified and the industrial applications of clean-up operation were suggested.

Quality Characteristics of Beef Patty Containing Gums (Gum류를 첨가한 우육 Patty의 품질 특성)

  • Jeong, In Cheol;Kim, Do Wan;Lee, Gyeong Su
    • Journal of the East Asian Society of Dietary Life
    • /
    • v.10 no.5
    • /
    • pp.404-404
    • /
    • 2000
  • In order to investigate the possibility of low fat meat products, beef patties were prepared with gumssuch as carrageenan, methyl cellulose, and xanthan gum. The quality characteristics of beef patties were examined. Moisture contents of raw and cooked patties of control were lower than those of patties containing gums. and fat content was higher than those of containing gums. There was no significant difference in the protein contents of patties. In case of L-value(lightness) of raw patty, the control was higher than those patties containing gums. a- ( redness) and b-value(yellowness) among patties were not significantly different. Cooking yield, fat retention, and water holding capacity of beef patties containing gums were higher than control beef patty, but salt soluble protein and gel strength were not significantly different. Significant difference did not exist among beef patties in hardness, but the chewiness and gumminess of patties containing gums were higher than control. In case of sensory evaluation, there was no significant difference among patties in aroma and palatability. Texture of control was higher than patties containing gums, and juiciness of control was higher than patties containing carrageenan.

Properties of Low-Fat Pork Patties Formulated with Carrageenan Alone or in Combination with Pectin or Potato Starch (Carrageenan에 pectin 및 potato starch를 혼합 첨가하여 제조한 저지방 돈육 patty의 특성연구)

  • Joo, Sin-Youn;Chung, Hai-Jung
    • Journal of the Korean Society of Food Culture
    • /
    • v.20 no.3
    • /
    • pp.360-366
    • /
    • 2005
  • This study was conducted to investigate the quality characteristics of low- fat pork patties containing fat replacers. Carrageenan(CA) in combination with pectin(PE) or potato starch(PO) was added as fat replacers and physicochemical properties were evaluated in low-fat pork patties cooked by oven-roasting or pan-frying. Uncooked and cooked pork patties formulated with fat replacers were higher in moisture and ash content and lower in fat content than those of control. The cooking yield and reduction in diameter of pork patties were significantly improved by the addition of fat replacers(p<0.05). Pork patties formulated with CA had the highest fat retention, while CA+PE had the highest water holding capacity. Hunter s L(lightness) value was not different from among patties and a(redness) and b(yellowness) values were higher in carrageenan-based patties than those of control patties. Hardness was higher in carrageenan-based patties than that of control and cohesiveness and springiness showed no difference among patties. Sensory analysis showed that flavor, juiciness and palatability of carrageenan-based patties were superior to control patties and combined use of CA with PE or PO provided improved acceptability of low-fat pork patties over that from using single carrageenan.

Optimization of disposable paper-based test strips for hypochlorous acid detection

  • Rita E. Ampiaw;Muhammad Yaqub;Changyeon Woo;Wontae Lee
    • Membrane and Water Treatment
    • /
    • v.14 no.4
    • /
    • pp.181-189
    • /
    • 2023
  • The Covid-19 pandemic has increased demand for chlorine-based sanitizing solutions, most of which contain hypochlorous acid (HOCl) as an active agent. Free chlorine (HOCl) in these sanitizers is crucial for their efficacy. Disposable test strips are affordable and convenient tools for determining various qualitative and quantitative parameters. In this study, disposable opto-chemical test strips were developed by physically immobilizing 3,3',5,5'-tetramethylbenzidine (TMB) and o-dianisidine (o-D) reagents on chromatography and filter paper-based test strips for the visualization and detection of free chlorine in the form of HOCl. The reagents undergo a rapid color change upon reaction with chlorine through a redox reaction. The paper-based test strips showed rapid color change within a minute and a low sample volume requirement (1 ml). This portable, disposable paper-based test strip is a simple and cost-effective way to rapidly detect the presence of HOCl sanitizers for home and field applications. Both TMB and o-D successfully detected chlorine. Chromatography paper proved to be the more efficient option among the two papers used as substrates for the reagents (TMB and o-D). It exhibited high retention capacity and high performance in terms of color transformation when reacting with HOCl, even after two months of storage.

Fabrication of Fe3O4/Fe/Graphene nanocomposite powder by Electrical Wire Explosion in Liquid Media and its Electrochemical Properties (액중 전기선 폭발법을 이용한 Fe3O4/Fe/그래핀 나노복합체 분말의 제조 및 전기화학적 특성)

  • Kim, Yoo-Young;Choi, Ji-Seub;Lee, Hoi-Jin;Cho, Kwon-Koo
    • Journal of Powder Materials
    • /
    • v.24 no.4
    • /
    • pp.308-314
    • /
    • 2017
  • $Fe_3O_4$/Fe/graphene nanocomposite powder is synthesized by electrical wire explosion of Fe wire and dispersed graphene in deionized water at room temperature. The structural and electrochemical characteristics of the powder are characterized by the field-emission scanning electron microscopy, X-ray diffraction, Raman spectroscopy, field-emission transmission electron microscopy, cyclic voltammetry, and galvanometric discharge-charge method. For comparison, $Fe_3O_4$/Fe nanocomposites are fabricated under the same conditions. The $Fe_3O_4$/Fe nanocomposite particles, around 15-30 nm in size, are highly encapsulated in a graphene matrix. The $Fe_3O_4$/Fe/graphene nanocomposite powder exhibits a high initial charge specific capacity of 878 mA/g and a high capacity retention of 91% (798 mA/g) after 50 cycles. The good electrochemical performance of the $Fe_3O_4$/Fe/graphene nanocomposite powder is clearly established by comparison of the results with those obtained for $Fe_3O_4$/Fe nanocomposite powder and is attributed to alleviation of volume change, good distribution of electrode active materials, and improved electrical conductivity upon the addition of graphene.

Charge-Discharge Characteristics of Lithium Metal Polymer Battery Adopting PVdF-HFP/(SiO2, TiO2) Polymer Electrolytes Prepared by Phase Inversion Technique (상반전 기법으로 제조한 PVdF-HFP/(SiO2, TiO2) 고분자 전해질을 채용한 리튬금속 고분자 2차전지의 충방전 특성)

  • Kim, Jin-Chul;Kim, Kwang-Man
    • Korean Chemical Engineering Research
    • /
    • v.46 no.1
    • /
    • pp.131-136
    • /
    • 2008
  • Silica- or titania-filled poly (vinylidene fluoride-co-hexafluoropropylene)-based polymer electrolytes were prepared by phase inversion technique using N-methyl-2-pyrrolidone and dimethyl acetamide as solvent and water as non-solvent. The polymer electrolytes were adopted to the lithium metal polymer battery using high-capacity cathode $Li[Ni_{0.15}Co_{0.10}Li_{0.20}Mn_{0.55}]O_2$ and lithium metal anode. After the repeated charge-discharge test for the cell, it was proved that the cell adopting the polymer electrolyte based on the phase-inversion membrane containing 40~50 wt% silica showed the highest discharge capacity (180 mAh/g) until 80th cycle and then abrupt capacity fade was just followed. The capacity fade might be due to the deposition of lithium dendrite on the polymer electrolyte, in which the capacity retention was no longer sustainable.

The Comparison of Electrical Conductivity for Soil Solutions Extracted in Field Capacity and Saturation-Paste (포장용수량과 포화 반죽 토양용액의 전기전도도 비교)

  • Lee, Ye-Jin;Lee, Jong-Sik;Yang, Jae-E.
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.43 no.6
    • /
    • pp.776-781
    • /
    • 2010
  • Estimating the electrical conductivity of the saturation-paste (SP) is a common method to assess soil salinity. To assess soil salinity realistically, it is important to extract soil solution under field capacity. However, few studies on salinity assessment have been conducted for soil solution extracted under field capacity (-33 kPa; FC) moisture condition due to difficulty in soil solution extraction. This study was conducted to evaluate whether saturation-paste can represent field condition. Soil solutions were extracted from 22 soils in the plastic film house (PFH) and 18 soils in the reclaimed land (RL) at saturation and field capacity moisture conditions. Those were analyzed for pH, EC, cations ($K^+$, $Ca^{2+}$, $Mg^{2+}$, $Na^+$) and anions ($Cl^-$, ${NO_3}^-$, ${PO_4}^{3-}$, ${SO_4}^{2-}$). Both cations and anions of soil solution extracted from FC showed high correlations with ions extracted from SP in the PFH and the RL, except for ${NO_3}^-$, ${PO_4}^{3-}$ in the RL. Results of the t-test, the ECe and $EC_{FC}$ were not significant at significance level 0.05. The slopes of the equations between $EC_{FC}$ and ECe at more than sand 50% soils were higher than less than sand 50% soils, and differences of saturation percentage between SP and FC showed larger as increasing sand percentage. EC was related to soil water retention by soil texture. To determine the EC, soil texture and other soil properties which effect the soil moisture should be considered.

Effects of Soil Amendments on Survival Rate and Growth of Populus sibirica and Ulmus pumila Seedlings in a Semi-arid Region, Mongolia (몽골 반건조 지역에서 토양 개량이 백양나무와 비술나무 묘목의 활착 및 생장에 미치는 영향)

  • Jung, Yegi;Yoon, Tae Kyung;Han, Saerom;Kang, Hoduck;Yi, Myong-Jong;Son, Yowhan
    • Journal of Korean Society of Forest Science
    • /
    • v.103 no.4
    • /
    • pp.703-708
    • /
    • 2014
  • This study was conducted to investigate effects of soil amendments on survival rate and growth of seedlings in a semi-arid region, Mongolia. 2-year-old Populus sibirica and Ulmus pumila seedlings were planted in alkaline sandy soils and treated with 2 levels of nitrogen, elemental sulfur, artificial moisture retention and converted loess. After 4 months, the seedling survival rate of both species decreased as the amount of nitrogen increased. Nitrogen has been generally known to increase seedling survival rate and growth by supplying nutrients, however, reduced survival rate in this study might be affected by consequential increase in soil osmotic pressure, which was caused by excessive nitrogen fertilization. The root collar diameter (RCD) growth of both species increased significantly by the treatment of converted loess, and only RCD growth of P. sibirica increased by the artificial moisture retention treatment. Although P. sibirica is drought-tolerant, it is in the group of Populus spp. which requires a high capacity of available water. Conversely, the elemental sulfur treatment showed no effect on survival rate and RCD growth for both species due to the low oxidation of sulfur in arid soils. The extended monitoring of seedling growth and soil characteristics is required to elucidate the long-term effects of soil amendments in the semi-arid region, and the further studies are also needed to examine the appropriate amount of fertilizers for both species.

A Review Study on Major Factors Influencing Chlorine Disappearances in Water Storage Tanks (저수조 내 잔류염소 감소에 미치는 주요 영향 인자에 관한 문헌연구)

  • Noh, Yoorae;Kim, Sang-Hyo;Choi, Sung-Uk;Park, Joonhong
    • Journal of Korean Society of Disaster and Security
    • /
    • v.9 no.2
    • /
    • pp.63-75
    • /
    • 2016
  • For safe water supply, residual chlorine has to be maintained in tap-water above a certain level from drinking water treatment plants to the final tap-water end-point. However, according to the current literature, approximately 30-60% of residual chlorine is being lost during the whole water supply pathways. The losses of residual chlorine may have been attributed to the current tendency for water supply managers to reduce chlorine dosage in drinking water treatment plants, aqueous phase decomposition of residual chlorine in supply pipes, accelerated chlorine decomposition at a high temperature during summer, leakage or losses of residual chlorine from old water supply pipes, and disappearances of residual chlorine in water storage tanks. Because of these, it is difficult to rule out the possibility that residual chlorine concentrations become lower than a regulatory level. In addition, it is concerned that the regulatory satisfaction of residual chlorine in water storage tanks can not always be guaranteed by using the current design method in which only storage capacity and/or hydraulic retention time are simply used as design factors, without considering other physico-chemical processes involved in chlorine disappearances in water storage tank. To circumvent the limitations of the current design method, mathematical models for aqueous chlorine decomposition, sorption of chlorine into wall surface, and mass-transfer into air-phase via evaporation were selected from literature, and residual chlorine reduction behavior in water storage tanks was numerically simulated. The model simulation revealed that the major factors influencing residual chlorine disappearances in water storage tanks are the water quality (organic pollutant concentration) of tap-water entering into a storage tank, the hydraulic dispersion developed by inflow of tap-water into a water storage tank, and sorption capacity onto the wall of a water storage tank. The findings from his work provide useful information in developing novel design and technology for minimizing residual chlorine disappearances in water storage tanks.