• Title/Summary/Keyword: Water-glass

Search Result 1,094, Processing Time 0.026 seconds

A Study on the Effects of Water Absorption on the Thermal Conductivity of Insulation Materials (수분 흡수가 단열재의 열전도계수에 미치는 영향에 관한 연구)

  • Yoo, Seong-Yeon;Kim, Tae-Ho
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.25 no.3
    • /
    • pp.119-125
    • /
    • 2013
  • IInsulation material is generally used for preventing heat loss from heat transport fluids, and water absorption severely reduces the insulation property. The purpose of this study is to evaluate the amount of water absorption supplied by the pouring method and spraying method, to investigate the effects of water absorption on the thermal conductivity of an insulation material, and modeling the relation between water absorption and thermal conductivity. E-glass, a kind of glass fiber, and HYPERLITE, mainly composed of pearlite, are selected, to compare hygroscopic and insulation properties. E-glass is found to have much higher water absorptivity, compared to HYPERLITE. The thermal conductivity of the water-absorbed E-glass is increased by more than 150%, compared to that of no absorption, while variation of the thermal conductivity of HYPERLITE with water absorption is insignificant. A three-stage model of water absorption for thermal conductivity is developed, and the modeling results are found to be in good agreement with the experimental data.

Effects of Nanoclay and Glass Fiber on the Microstructural, Mechanical, Thermal, and Water Absorption Properties of Recycled WPCs

  • Seo, Young-Rok;Kim, Birm-June;Lee, Sun-Young
    • Journal of the Korean Wood Science and Technology
    • /
    • v.47 no.4
    • /
    • pp.472-485
    • /
    • 2019
  • When wood plastic composites (WPCs) have been used for a certain period of time, they become waste materials and should be recycled to reduce their environmental impact. Waste WPCs can be transformed into reinforced composites, in which fillers are used to improve their performance. In this study, recycled WPCs were prepared using different proportions of waste WPCs, nanoclay, and glass fiber. The effects of nanoclay and glass fiber on the microstructural, mechanical, thermal, and water absorption properties of the recycled WPCs were investigated. X-ray diffraction showed that the nanoclay intercalates in the WPCs. Additionally, scanning electron micrographs revealed that the glass fiber is adequately dispersed. According to the analysis of mechanical properties, the simultaneous incorporation of nanoclay and glass fiber improved both tensile and flexural strengths. However, as the amount of fillers increases, their dispersion becomes limited and the tensile and flexural modulus were not further improved. The synergistic effect of nanoclay and glass fiber in recycled WPCs enhanced the thermal stability and crystallinity ($X_c$). Also, the presence of nanoclay improved the water absorption properties. The results suggested that recycled WPCs reinforced with nanoclay and glass fiber improved the deteriorated performance, showing the potential of recycled waste WPCs.

THE EFFECT OF EARLY WATER CONTACT ON GLASS-IONOMER CEMENTS (Glass ionomer cement초기 경화시 수분접촉의 영향에 관한 연구)

  • Um, Chung-Moon;Oilo, Gudbrand
    • Restorative Dentistry and Endodontics
    • /
    • v.18 no.2
    • /
    • pp.507-513
    • /
    • 1993
  • The purpose of this study was to observe the effect of immersion in water at 3, 5, 7, and 10 minutes after mixing on the surface of three regular and one light-curing glass-ionomer cement by measuring penetration of a methylene blue solution. Early solubility of these cements was also measured and compared with that of a zinc phosphate and a polycarboxylate cement. A blue-stained zone was observed in all glass-ionomer cement, but an inner, opaque zone was observed in only two of the regular glass-ionomer cements. Extending the time between start of mixing and immersion on water decreased the width of both zones in all cements and markedly lowered the loss of substance from the surface of regular glass-ionomer cements. However, time after mixing had no or only a limited effect on the loss of substance from the light-curing glass-ionomer cement, the zine phosphate cement, or the polycarboxylate cement.

  • PDF

Evaluation of Efficiency on Glass Precision Machining by using Abrasive Water-jet (연마재 워터젯 가공을 이용한 유리 미세 가공 성능 평가)

  • Bahk, Yeon-Kyoung;Park, Kang-Su;Kim, Hyung-Hoon;Shin, Bo-Sung;Ko, Jong-Soo;Go, Jeung-Sang
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.27 no.7
    • /
    • pp.87-93
    • /
    • 2010
  • This paper presents an evaluation of efficiency on glass precision machining by using abrasive water-jet machine. In this study, problems of conventional water-jet machining are examined experimentally and are analysized numerically. Especially, the reason of whitening on the machined surface of biochip glass is determined. It is found that the mass flow rate of abrasive input and transverse speed of water-jet are key parameters to control the direct machining of micro hole and channel on a glass substrate. Based on results of experimental analysis, possibility of direct fabrication of micro holes and channels on a glass substrate is successfully confirmed.

Impermeability of Earth Natural Grouting Method (ENG 공법의 차수효과 연구)

  • Jung, Min-Hyung;Kim, Yong-Sik;Jung, Chun-Hak;Lee, Song
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2009.03a
    • /
    • pp.836-843
    • /
    • 2009
  • The Water Glass grouting method has been applied frequently to impermeable grouting in practice. But there is raising problems which are durability decrease by passage time and environmentally adverse effect. So, Earth Natural Grouting method which uses micro cement is developed to overcomes the problems of the Water Glass grouting method. And it is displayed ground injection extent like Water Glass grouting method. For verifying impermeability of ENG, it is carried out a triaxial permeability test about manufacturing specimen of ENG, SGR method which is a presentative Water Glass grouting method. Although Coefficient of permeability, k, of SGR is measured a little high than k of ENG whose value is $a{\times}10^{-6}cm/sec$, the value of ENG belong to impermeable rage. And, k of SGR shows relatively rapid increase according to cure time due to durability decrease of water glass. Also, in-situ test result of ENG has similar value with SGR method for similar ground.

  • PDF

Glass Transition Temperature of Honey Using Modulated Differential Scanning Calorimetry (MDSC): Effect of Moisture Content

  • Kim, Mi-Jung;Yoo, Byoung-Seung
    • Preventive Nutrition and Food Science
    • /
    • v.15 no.4
    • /
    • pp.356-359
    • /
    • 2010
  • Glass transition phenomena in nine Korean pure honeys (moisture content 18.3~20.1%) and honey-water mixtures by different water contents (0, 2, 5, and 10% w/w) were investigated with modulated different scanning calorimetry (MDSC). The total, reversing, and non-reversing heat flows were quantified during heating using MDSC. Glass transition was observed from reversing heat flow separated from the total heat flow. The glass transition temperatures ($T_g$) of pure honeys, which are in the range of $-42.7^{\circ}C$ to $-50.0^{\circ}C$, varied a lot with low determination coefficient ($R^2$=0.63), whereas those of honey-water mixtures decreased with a decrease in honey content. The $T_g$ values were also more significantly different among honey-water mixtures when compared to pure honeys, indicating that in the honey-water mixture system the $T_g$ values appear to be greatly dependent on moisture content. The measured heat capacity change (${\Delta}C_p$) was not influenced by moisture content.

Pressure Loss and Heat Transfer Characteristics of the Glass Beads-Water Flow in a Vertical Tube (수직관내 유리알-물 유동의 압력손실 및 열전달 성능)

  • Kim, N.H.;Kim, J.S.;Lee, Y.P.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.8 no.4
    • /
    • pp.550-560
    • /
    • 1996
  • Recently, fluidized bed heat exchangers with circulating liquid are widely used in a number of places-chemical, process, food concentration, waste water treatment facilities, etc. In a circulating heat exchanger, solid particles circulate with the liquid, thereby increase the heat transfer and reduce the fouling potential of the heat exchanger. In this study, glass beads were circulated through a vertical tube. The pressure loss and the heat transfer coefficient were measured. At low flow velocities, glass beads enhanced the heat transfer considerably. The enhancement increased as the volume fraction of the glass beads increased. The pressure loss showed a similar trend. From the observed particle behavior near tube wall, a possible explanation of the trend is provided.

  • PDF

Pressure Loss and Heat Transfer Characteristics of the Glass Bead - Water Flow in a Vertical Tube (수직관내 유리알-물 유동의 압력손실 및 열전달 성능)

  • 김내현;김정식;이윤표
    • Proceedings of the Korea Society for Energy Engineering kosee Conference
    • /
    • 1996.04a
    • /
    • pp.121-131
    • /
    • 1996
  • Recently, circulating liquid fluidized bed heat exchangers are widely used in a number of places - chemical, process, food concentration, waste water treatment facilities, etc. In a circulating heat exchanger, solid particles circulate with the liquid, thereby increase the heat transfer and reduce the fouling potential of the heat exchanger. In this study, glass beads were circulated through a vertical tube. The pressure loss and the heat transfer coefficient were measured. At low flow velocities, glass beads enhanced the heat transfer considerably. The enhancement increased as the volume fraction of the glass beads increased. It also increased as the particle diameter increased. The pressure loss showed a similar trend. From the observed particle behavior near tube wall, a possible explanation of the trend is provided.

  • PDF

Upstream Behavior of Glass Eels (Anguilla japonica) in an Experimental Eel-ladder (실험 어도에서 실뱀장어의 소상 행동)

  • Hwang, Sun-Do;Lee, Tae Won;Hwang, Hak-Bin;Choi, Il-Su;Hwang, Sun Jae
    • Korean Journal of Ichthyology
    • /
    • v.21 no.4
    • /
    • pp.262-272
    • /
    • 2009
  • Upstream behavior of glass eels was examined in an experimental eel-ladder at a laboratory of the National Fisheries Research and Development Institute from March to May in 2008. The study was made under various environmental factors and conditions affecting the upstream migration of glass eels in order to design a functional ladder that would allow the passage of glass eels. The experimental eel-ladder consisted of an upper freshwater chamber and a lower sea water chamber; glass eels in sea water can move up to the upper freshwater chamber through the slope (eel-ladder) between them. The optimal condition of the eel-ladder was estimated by comparing the number of glass eels that moved upstream depending on various conditions. Since the glass eels actively moved up the slope to river water rather than to reservoir water or tap water, the experiment was realized using river water. A significantly higher number of glass eels moved up during the spring tide than during the neap tide, and during night than during the day. Upstream movement was significantly higher during high tide than during low tide. Glass eels effectively moved up through a slope of less than $30^{\circ}$ and water-flow velocity lower than 0.4 m/sec. The fish preferred a coarser ladder bed covered with small gravels, brush or carpet.

A STUDY ON THE VICKER'S HARDNESS AND DIAMETRAL TENSILE STRENGTH OF HYBRID GLASS IONOMER (Hybrid Glass Ionomer cement의 비커스경도와 간접인장강도에 관한 연구)

  • Kwon, Kyun-Won;Park, Sang-Jin
    • Restorative Dentistry and Endodontics
    • /
    • v.22 no.2
    • /
    • pp.505-518
    • /
    • 1997
  • The objective of this investigation was to compare the effects of water storage on the aspect of hardness and diametral tensile strengths of four hybrid glass ionomer cements(two compomers and two resin-reinforced glass ionomers) with a resin composite material. One composite resin(Degufill Ultra), two compomers(Dyract, Compoglass Cavifil), and two resin-reinforced glass ionomers(Fuji Duet, Vitremer) were used in this study. Cylindrical specimens were prepared and stored at $36{\pm}1^{\circ}C$ in distilled water for 10 minutes after set, and then tested on an Instron testing machine(No.4467) at 1.0 mm/min displacement rate. Vicker's hardness and diametral tensile strengths as time elapsed were measured after aging in water for 10 minutes, 1 hour, 3 hours, 1 day, 3 days, 5 days and 7 days at $36{\pm}1^{\circ}C$. During the test of diametral tensile strength, stress-strain curves were obtained, from which the compressive modulus were calculated and compared. The structure of four set glass ionomer cement mass was observed on SEM(Hitachi, S-2300) after being etched with 9.6% hydrofluoric acid for 1 minute. The results were as follows; 1. The hardness of the experimental group(compomer and the resin reinforced glass ionomer cement) did not exceed the value of control group(Degufill Ultra). 2. Vicker's hardness of the Fuji Duet tended to increase succeedingly, Dyract was decreased after 3 hours in water, and Vitremer was the lowest. 3. The control group(Degufill Ultra) presented progressively on increased diametral tensile strength with time, Fuji Duet were decreased after 3 days, Compoglass Cavifil and Vitremer were decreased after 5 days in water storage. 4. Compressive modulus of the control group(Degufill Ultra) and Dyract were increased sharply timely, Fuji Duet and Vitremer were increased smoothly by lapse of time in water. Fuji Duet were stronger than Vitremer. On the other hand, Vitremer exhibited the lowest toughness. 5. The microstructure of compomer was similar with that of the composite resin(Degufill Ultra), and the fillers in resin-reinforced glass ionomer cements were noticed. It can be concluded that mechanical properties of hybrid glass ionomer cements is weaker than composite resin, and that the compomers or the resin-reinforced glass ionomers can not substitute the composite resins. A plenty of considerations should be done on the application of them to the area under the loading and high wear has a little adverse effect on the mechanical properties on the water storage for 7 days. The further research should be needed to confirm the advantage of the compomer.

  • PDF