• Title/Summary/Keyword: Water treatment System

Search Result 2,440, Processing Time 0.033 seconds

Study on the alternatives to trace the origin and to diminish the sediments of drinking water (수돗물의 앙금발생규명 및 저감기술방안)

  • 김갑수;임병진;권은미
    • Journal of environmental and Sanitary engineering
    • /
    • v.9 no.1
    • /
    • pp.17-28
    • /
    • 1994
  • There are many possibilities that may lead to low quality of drinking water Recently, some unknown deposits in tap water raised a lot of public concern regarding the safety of drinking water in Seoul. We analyzed the quality of tap water from several areas of Seoul, including the area where public complaints about tap water were high. The results shows that the quality of tap water in Seoul was good, well below the environmental standards. Only the tap water from the area with high public complaints showed turbidity higher than that of other area. Also, result shows that component of deposit in tap water was Al, Fe, Mn, and Zn. Based on the research result we propose several measures that might help to reduce the amount of deposit in tap water as follows : 1 Using coagulant aid when coagulating or adjusting pH when filtering. 2. Replacing old water pipeline with new corrosive- resistant one. 3. Increasing water treatment efficiency by enhancing water treatment system such as automation of water treatment system adjusting production capacity, and improving operational condition of filler basin. 4. Chlorine disinfection at the distribution reservoir would help maintaining the same pH level and chlorine concentration throughout the water pipeline and reduce corrosion of pipe.

  • PDF

Research of Sludge Quantity and Evaluation of Sludge Handling Facilities in Water Treatment Plants (정수 슬러지 발생량 조사 및 슬러지 처리시설의 공정평가)

  • Moon, Seong-Yong;Kim, Seung-Hyun
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.18 no.3
    • /
    • pp.279-290
    • /
    • 2004
  • Sludge quantity has increased at "A"water treatment plant due to deterioration of raw water quality and GAC installation. Increased sludge resulted in overloading on sludge handling facilities. The object of this study is to survey sludge quantity and capacity of sludge handling facilities at "A"water treatment plant. Measured quantity of sedimentation sludge considerably exceeded the design capacity of sludge holding basin. Sludge holding basin was properly designed, but low concentration of sludge discharged from sedimentation basin caused production of large volume of the sludge. Timer operated control system for sludge withdrawal unit and leakage through a control valve were suspected to cause the low concentration. Augmentation of the control system by a turbidity meter and addition of a new control valve successfully reduced the sludge volume enough to satisfy the design capacity of sludge holding basin. Unlike sedimentation sludge, measured quantity of washwater was considerably less than the design capacity of washwater basin because it was over-designed.

Development of Water Quality Management Model for Rural Area Using Decision Support System (의사결정지원기법을 이용한 농촌유역 수질관리모형의 개발)

  • 양영민;권순국
    • Proceedings of the Korean Society of Agricultural Engineers Conference
    • /
    • 1999.10c
    • /
    • pp.783-788
    • /
    • 1999
  • In this study, a decision support system (DSS) was developed to calculate optimal wastetreatment cost, treatment level and treatment quantity of various pollutants for applying for in rural basin. The DSS includes a gegraphic informatino system (GIS), relational database system (RDBS), water quality models(Loading function , WASP5), watershed pollution load calculation module(SPLC), optimal water quality management plan to satisfy the water quality regulations. The system can be modified by user to trace the optimal condition for decision. The effort was conducted to apply the developed DSS to select the for optimal water quality management plan small rural basin called Kwanri Stream.

  • PDF

Development of the Electrolysis Ballast Water Treatment System and Test (직접 전기분해식 선박평형수 처리장치 개발과 시험에 관한 연구)

  • Bag, Og-Yeol;Moon, Jang;Park, Jun-Mo;Kong, Gil-Young
    • Journal of Navigation and Port Research
    • /
    • v.41 no.3
    • /
    • pp.79-86
    • /
    • 2017
  • Ballast water filled into and discharged from the ballast tank of a ship has a negative impact on local marine environment due to various aquatic organisms contained therein. The IMO developed and adopted "The International Convention for the Control and Management of Ships Ballast Water and Sediments, 2004" with the purpose of protecting the marine environment from transfer of harmful aquatic organisms in ballast water carried by ships. The IMO BWM Convention was approved in September 2016 and ships must be equipped with ballast water management system after September 2017. Ships' ballast water treatment methods are divided into using active substances as electrolytic type, ozone type, chemical dosing type and using physical treatment type as filter type, ultraviolet type. It is also used with a combination of two methods. Electrolysis is superior in terms of cost and efficiency. In this study, basic principles, components, and land base test contents of electrolysis ballast water treatment system, a direct electrolyzed ballast water treatment system, were examined. Land base test was conducted with 300m3/h capacity device at the KIOST Geoje plant where the government test facility was installed. This test validated that the system meets IMO standards.

The Determination of Coagulant Feeding Rate in the Water Treatment Plant Using Intelligent Algorithms

  • Kim, Yong-Yeol;Jung, Hyung-Tae;Jang, Gil-Soo;Park, Chul-Hong;Kang, E-Sok
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2001.10a
    • /
    • pp.123.2-123
    • /
    • 2001
  • It is difficult to determine the feeding rate of coagulant in the water treatment plant, due to nonlinearity, multivariables and slow response characteristics, etc. To deal with this difficulty, the neuro-fuzzy system and the genetic-fuzzy system were used in determining the feeding rate of the coagulant. The fuzzy system is excellently robust in multi-variables and nonlinear problems. Therefore it uses basic algorithm, but it is difficult to construct of the fuzzy parameter such as the rule table and the membership function, Therefore we made the neuro-fuzzy system and the genetic-fuzzy system with the fusion of learning algorithms and compared the performance of the two fuzzy systems. To apply these algorithms, we made the rule table, membership function from the actual operation data of the water treatment plant. We determined optimized feeding rate of coagulant using the fuzzy operation, and also compared ...

  • PDF

The Study of DAF-System to Apply the CSOs Treatment (CSOs의 오염물질 제거시 DAF-system의 적용에 관한 연구)

  • Lee, Tae-Gwan
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.18 no.3
    • /
    • pp.385-391
    • /
    • 2004
  • This paper examines the applicability of DAF-system to the domestic sewers for the effective CSOs treatment. The procedures for the experiment include mainly two steps. One is to analyse the water qualities and settling test of the CSOs and the other focuses on general characteristics of the CSOs such as the removal efficiency of pollutant, the distribution of particle size and mass balance of DAF-system. The result of this study show that the application of DAF-system is more effective and economical than the existing treatment systems because it has two removal mechanisms of sedimentation and flotation simultaneously.

Land Based Test of Ballast Water Treatment System by Ozonation

  • Park, Sung-Jin;Yoon, Seung-Je;Kim, In-Soo
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.34 no.3
    • /
    • pp.383-390
    • /
    • 2010
  • This study is currently giving priority to developing the ship's ballast water treatment system using ozone (Ozone BWTS). The Ozone BWTS was tested in a full scale land-based mobile barge to evaluate performance according to the IMO G8 Guidelines. Test cycles using the mobile-barge were conducted in seawater and brackish water in the vicinity of the Port of Busan and Nakdong River, Republic of Korea. All tests were conducted according to the requirements of the G8 Guidelines. Test results show that the Ozone BWTS meets the Ballast Water Performance Standard contained in Regulation D-2 of the IMO Ballast Water Management Convention, as well as all of the operational, safety, and environmental testing requirements of the G8 Guidelines, as required for type approval of IMO. The study results show that the Ozone BWTS is capable of meeting the Ballast Water Performance Standard under Regulation D-2 of the International Convention for the Control and Management of Ships’ Ballast Water and Sediments, and also the more stringent standards being proposed under US legislation.

Development of Heat Pump Use Slurry Pig Manure Evaporation Drying System (열펌프를 이용한 슬러리 돈분뇨 증발건조처리시스템 개발)

  • Kim H. T.;Choi H. L.
    • Journal of Biosystems Engineering
    • /
    • v.30 no.1 s.108
    • /
    • pp.32-37
    • /
    • 2005
  • This study was conducted the slurry pig manure treatment by condensation drying of liquid from the slurry manure with a heat-pump and electric heater combined with air flow channel system. The system was designed as liquid and solid matters separation of slurry manure, and it can doing continuous input of slurry manure from a pig house, and it can operated year round use for pig farms. The separation of liquid and solid matters from slurry manure needed the prevention of solid accumulation in the system. The system was designed as closed space from outside air space for maximized evaporation of liquid and the condensation of liquid from slurry manure. The system can be operated the pig slurry manure treatment regardless of seasons in a yew. The separated evaporation water from the pig slurry manure by the heat-pump was satisfactorily pure water that can be used as washing water in livestock farms. The system can applicate to about 100 heads of pig, and the proper area of evaporation plate system was considered around $10\;m^2$. The input electrical energy of about 15 kWh which the cost equal to 250,000 won per month.

Evaluating Commercial Spray Applications of Lactic Acid, Hot Water, and Acidified Sodium Chlorite for the Reduction of Escherichia coli on Beef Carcasses

  • Kang, Dong-Hyun;Lee, Sun-Young
    • Food Quality and Culture
    • /
    • v.2 no.1
    • /
    • pp.55-60
    • /
    • 2008
  • This study examined the effects of lactic acid spray, hot water spray, or their combined treatment, as well as the effects of acidified sodium chlorite (ASC), for the decontamination of Escherichia coli on beef carcass surfaces using a commercial intervention system. With this system, the effects of 2 or 4% lactic acid (v/v), hot water ($89{\pm}1^{\circ}C$), or their combined treatment, were examined in terms of reducing inoculated E. coli. ASC (266 ppm), which was adjusted to pH 2.5 using acetic acid or citric acid, was applied using a hand-held spray system. When the beef carcasses were treated with 2 or 4% lactic acid for 10.4 s, less than 1 log reductions of inoculated E. coli were observed. A hot water spray treatment for 9.8 s resulted in a 2.1 log reduction of inoculated E. coli. However, when the hot water was followed with either 2 or 4% lactic acid, no difference in E. coli reduction was found between the hot water alone or the combined treatment with lactic acid. When ASC was adjusted to pH 2.5 with acetic acid and citric acid, 3.8 and 4.1 log reductions of E. coli were observed, respectively. Overall, the lactic acid spray treatment was least effective, and the ASC treatment was most effective, for the E. coli decontamination of beef carcasses. Therefore, these data suggest that ASC would be a more effective intervention against E. coli than most of the methods currently being used. However, more research is required to evaluate the effects of ASC on other organisms, as well as to identify application methods that will not affect meat quality.

  • PDF

A Study on the Determination of Dosing Rate for the Water Treatment using Genetic-Fuzzy (유전-퍼지를 이용한 정수장 응집제 주입률 결정에 관한 연구)

  • 김용열;강이석
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.5 no.7
    • /
    • pp.876-882
    • /
    • 1999
  • It is difficult to determine the feeding rate of coagulant in the water treatment process, due to nonlinearity, multivariables and slow response characteristics, etc. To deal with this difficulty, the genetic-fuzzy system was used in determining the feeding rate of the coagulant. The genetic algorithms are excellently robust in complex optimization problems. Since it uses randomized operators and searches for the best chromosome without auxiliary informations from a population consists of codings of parameter set. To apply this algorithms, we made the lookup table and membership function from the actual operation data of the water treatment process. We determined optimum dosages of coagulant(LAS) by the fuzzy operation, and compared it with the feeding rate of the actual operation data.

  • PDF