• 제목/요약/키워드: Water transmission system

검색결과 279건 처리시간 0.029초

네트워크 통합관리시스템과 보안스위치를 이용한 반송정수장 무선랜 구축사례 (The case study on wireless lan design technique for Bansong purification plant using network integrated management system and security switch)

  • 박은철;최현주
    • 상하수도학회지
    • /
    • 제32권4호
    • /
    • pp.309-315
    • /
    • 2018
  • Currently, the commercialization of the $5^{th}$ Generation (5G) service is becoming more prevalent in domestic communication network technology. This has reduced communication delay time and enabled large-capacity data transmission and video streaming services in real-time. In order to keep pace with these developments, K-water has introduced a smart process control system in water purification plants to monitor the status of the water purification process. However, since wireless networks are based on the public Long Term Evolution (LTE) network, communication delay time remains high, and high-resolution video services are limited. This is because communication networks still have a closed structure due to expense and security issues. Therefore, with 5G in its current form, it is very difficult to accommodate future services without improving the infrastructure of its communication networks. In recognition of these problems, this study implemented the authentication and management function of wireless networks on a wired network management system in the K-water Bansong water purification plant. The results confirmed that wired Local Area Network (LAN) services give a higher security performance than an expensive commercial wireless LAN system. This was achieved by using an Internet Protocol (IP) address management system of wired networks and the packet filtering function of the Layer2 (L2) switch. This study also confirmed that it is possible to create a wireless LAN service that is 3.7 times faster than the existing LTE communication network.

가연성 물질에 따른 워터커튼 시스템의 열 및 연기유동 제어특성에 관한 연구 (A Study on the Effect of Inflammable Materials on the Control Characteristics of Thermal and Smoke Fluid of Water Curtain System)

  • 유우준;남준석;김동준;이정균;유홍선
    • 한국화재소방학회논문지
    • /
    • 제26권2호
    • /
    • pp.53-58
    • /
    • 2012
  • 본 연구에서는 가연성 물질을 고려한 워터커튼 시스템(Water Curtain System)의 열 및 연기유동 제어 특성을 실험적으로 분석하였다. 이를 위해서 Room Corner Tester(RCT)를 사용하여 연료의 종류가 소나무(PineWood)와 가솔린(Gasoline)인 경우 각각의 발열량(Heat Release Rate)을 구하였으며, 워터커튼용 화재실험 장치를 제작하여 화원근방에서 5m 떨어진 지점의 천장 부근에 분사각도 $180^{\circ}$, 오리피스 직경 8.2 mm의 노즐(Nozzle)을 설치한 후 목재와 가솔린 각각에 대해서 화재실험을 실시하여 워터커튼 전후의 온도분포와 가시도를 측정하였다. 그결과 워터커튼 시스템의열및연기유동 제어는 가연성 물질의 연소특성에 따른 고온의 연기발생량과 분사 노즐에 의한 유동현상이 중요한 상관관계를 갖고 있음을 확인하였다.

여과수열원 히트펌프를 이용한 온실난방기술 개발 (Development of Heating Technology for Greenhouse by Use of Ground Filtration Water Source Heat Pump)

  • 문종필;이성현;강연구;이수장;김경원
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2010년도 춘계학술대회 초록집
    • /
    • pp.172.2-172.2
    • /
    • 2010
  • This study was carried out in order to reduce the installation expense of heating system for greenhouse comparing to geothermal heat pump and develope the coefficient of performance (COP) for a heat pump. For getting plenty of heat flux from geothermal energy. Surface water in river channel was used for getting a lots of geothermal heat by penetrating water through underground soil layer of the river bank that make heat transmission to passing water. The range of water temperature after the process of Ground filtration is 13~18 degrees celsius which is very similar to low heat source of geothermal heat pump system and the plenty amount of heat source from that make the number of geothermal heat exchanging hole and the expense for geothermal heat exchanger construction reduced. Drainage well is also used for returning filtration water to the aquifer that keep the water good recirculation from losing geothermal heat and water resource. For the COP improvement of Heat pump, thermal storage tank with separating insulation plate according to the temperature difference make the COP of Heat pump that is similar to thermal storage tank with diffuser. Developed thermal storage tank make construction expense cheaper than customarily used one's. and that sand filter and oxidation sand (FELOX) are going to be used for improving ground filtration water quality that make heat exchanger efficiency better. All above developed component skill are going to be set on the Ground filtration water source heat pump system and applied for medium, large scale for protected greenhouse in riverside area and on-site experiment is going to do for optimizing the heating system function and overcome the problem happening in the process of on-site application afterward.

  • PDF

A Remote Monitoring and Control System for Waste Treatment Facility via Public Communication Network.

  • Jung, Jae-Hak;Choi, Jin-Yong
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2001년도 ICCAS
    • /
    • pp.124.2-124
    • /
    • 2001
  • The research for development of remote monitoring and control systems composed three stages of research categories. At the first stage, we decided the suitable instrumentation devices for interface between H/W systems and waste water treatment facility. And at the second stage, we developed the software package for remote monitoring and data transmission system including data receipt system via wired telephone line. At the final stage we developed local control system for auto-process control of waste water treatment facilities. For the first stage of research we developed the a drawing of design the instrumentation and selected optimal sensors or monitoring basic important data. After the first stage research we developed the software package with Graphic User Interface(GUI) ...

  • PDF

3단 회전식 건조성형장치 설계 프로그램 개발 (A Development of Design System Program for the 3-pass rotary dryer)

  • 김태식;최윤환;도덕희;이연원
    • 동력기계공학회지
    • /
    • 제10권2호
    • /
    • pp.36-40
    • /
    • 2006
  • In order to prevent the environmental pollution, the dryers are commonly used to treat sludge that one of sewages is polluting the quality of water. Generally, the drying method is various as to the property of material and use. Rotary dryer is a good apparatus to treat them. It is the way that is to make substance transmission and heat using hot air between sludge particle and heated gas. In this paper, we developed a 3-pass rotary dryer for a design program for the 3-pass rotary dryer with various conditions. The working conditions of dryer are a raw sludge feed rate, input & output water content and operation time etc.

  • PDF

유기 EL 보호층으로 적용하기 위한 무기 복합 박막의 투습율 특성 연구 (Study on the Water Vapor Permeation Properties of the Inorganic Thin Composite Film for the Passivation Layer in the OLED)

  • 김광호;이주원;김영철;주병권;김재경
    • 한국전기전자재료학회논문지
    • /
    • 제17권4호
    • /
    • pp.432-438
    • /
    • 2004
  • In this study, we investigated the WVTRs Properties of inorganic thin composite films(ITCFs) to be newly adopted as the passivation layer of the OLED to replace the inorganic compound material Because we thought that inorganic compound materials were limited to enhance the barrier property of thin film. So, ITCFs were fabricated by mixing the cooperated material with the base material. And then, ITCFs were deposited onto the plastic substrate using the electron beam evaporation system and the water vapor transmission rates(WVTRs) were measured using the Mocon equipment. As a result of the WVTR measurement, we could analyze the WVTR values for various ITCFs. ITCFs had a remarkably lower value than the inorganic compound film. Through the analysis of thin film, we can understand the crystal structure and mixed amount. Therefore, ITCFs can be used as the inorganic passivation layers of OLED with the inorganic compound film.

진동수주형 파력발전 시스템에서 운동과 파랑회절의 영향 (Motion and Wave Transmission Effect on Floating OWC(Oscillating Water Column) Wave Energy Conversion System)

  • Lee, Sang-moo;Kim Seoung-gun
    • 한국해양공학회:학술대회논문집
    • /
    • 한국해양공학회 2001년도 춘계학술대회 논문집
    • /
    • pp.20-25
    • /
    • 2001
  • 부유식 파랑에너지 변환시스템(Oscillating Water Column)에서 에너지 변환은 입력파와 챔버, 챔버내 공기의 상호작용으로 이루어진다. 이 논문은 파랑에너지를 기계적 운동으로 변환하는 기계적 특성을 해석한다. 단일 진동수 규칙파가 입력되었을 때에 파에 의하여 챔버의 상하운동이 선형적으로 발생하며, 이 상하운동은 챔버내의 압력 변화에 영향을 받는다. 상하운동과 챔버내로 투과한 파, 그리고 챔버내 압력에 의해 발생되는 파에 의해 챔버내의 상대운동을 정하고, 그 상대운동에 의한 공기의 압축 팽창과 온도상승을 근사적 열역학적 방정식으로 해석하여 오리피스를 통한 유량과 압력을 기준으로 에너지 변환요율을 결정하였다. 얻어진 식은 간단하면서도 관련요소의 영향을 전반적으로 표현한다. 개구율 변화에 따른 운동응답을 비교하였다.

  • PDF

The submerged flexible membrane breakwaters in oblique seas

  • S.T.Kee
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 2001년도 학술발표회 논문집(II)
    • /
    • pp.1133-1138
    • /
    • 2001
  • The focus of this paper is on the numerical investigation of obliquely incident wane interactions with a system composed of full submerged and floating dual buoy/vertical-flexible-membrane breakwaters placed in parallel with spacing. The fully submerged systems allow surface and bottom clearances to enable wave transmission over and under the system. The problem is formulated based on the two-dimensional multi-domain hydro-elastic linear wave-body interaction theory. The hydrodynamic interaction of oblique incident waves with the combination of the rigid and flexible bodies was solved by the distribution of the simple sources (modified Bessel function of fille second kind) tat satisfy the Helmholz governing equation. Using this computer program, the performance of various dual systems varying buoy radiuses and drafts, membrane lengths, clearances. spacing, mooring-lines stiffness, mooring types, water depth, and wave characteristics is thoroughly examined. It is found that the fully submerged and floating dual buoy/membrane breakwaters call, if it is properly tuned to the coming waves, have good performances ill reflecting the obliquely incident waves over a tilde range of wave frequency and headings.

  • PDF

홍수 및 수질 오염 감시용 지능형 고속 광 통신 시스템 개발에 관한 연구 (The study on the development of intelligent optical communication system to monitor flood and water pollution)

  • 이진영
    • 디지털융복합연구
    • /
    • 제10권11호
    • /
    • pp.351-358
    • /
    • 2012
  • 본 연구는 강유역의 홍수 및 수질 오염을 보다 효율적으로 관리하기 위해 고품질의 영상정보를 고속으로 전달할 수 있는 광통신 장치로 기존의 장치에 비해 저렴하면서도 네트워크 광선로 및 장비상태를 실시간으로 모니터링이 가능한 시스템을 제안한다. 홍수 통제용으로 이용되는 통신장비는 주로 무인함체 내에 설치되어 있고 이는 장거리 구간의 강 하구에 위치한 홍수 통제소에서 운용하고 있기 때문에 광 케이블의 절단이나 노화 등에 의한 통신 장해 발생시 신속한 대처가 어려운 문제가 있다. 따라서, 본 연구에서는 광 선로를 이용하여 고품질의 영상정보를 고속으로 전달할 수 있으면서도 위와 같은 사고 발생시 1차적으로 이중화 광 케이블 보호절체 기능을 이용하여 문제를 해결하고, 실시간 모니터링 기능으로 발생 지점을 실시간으로 통보해줌으로써 보다 효율적인 관리가 가능한 시스템을 제안하였다. 또한, 제안된 시스템은 지능형 교통 시스템 등 다양한 분야에서 폭넓게 활용이 가능할 것으로 판단된다.

전력구내 지중케이블 강제냉각에서의 적정냉각구간에 관한 연구 (A Study on the Optimum Cooling Span of the Underground Power Transmission Cable Equipped by a Forced Cooling System)

  • 이재헌;정상호;김재근;박만홍
    • 설비공학논문집
    • /
    • 제2권1호
    • /
    • pp.49-62
    • /
    • 1990
  • The forced cooling system has been widely applied to passing more electric current in the underground power transmission cable technology. In this paper, the optimum cooling span of the in-trough-indirect water cooling method within an electric tunnel was investigated. A parametric study was performed for the cable currents, the coolant flow rates, and the coolant inlet temperatures. As a result, the temperature of the inlet air has been found as the most important parameter in determination of the optimum cooling span.

  • PDF