• 제목/요약/키워드: Water transfer characteristic

검색결과 94건 처리시간 0.029초

Conceptual Design of Passive Containment Cooling System for Concrete Containment

  • Lee, Seong-Wook;Baek, Won-Pil;Chang, Soon-Heung
    • 한국원자력학회:학술대회논문집
    • /
    • 한국원자력학회 1995년도 추계학술발표회논문집(1)
    • /
    • pp.358-363
    • /
    • 1995
  • A study on passive cooling systems for concrete containment of advanced pressurized water reactors has been performed. The proposed passive containment cooling system (PCCS) consist of (1) condenser units located inside containment, (2) a steam condensing pool outside containment at higher elevation, and (3) downcommer/riser piping systems which provide coolant flow paths. During an accident causing high containment pressure and temperature, the steam/air mixture in containment is condensed on the outer surface of condenser tubes transferring the heat to coolant flowing inside tubes. The coolant transfers the heat to the steam condensing pool via natural circulation due to density difference. This PCCS has the following characteristic: (1) applicable to concrete containment system, (2) no limitation in plant capacity expansion, (3) efficient steam condensing mechanism (dropwise or film condensation at the surface of condenser tube), and (4) utilization of a fully passive mechanism. A preliminary conceptual design work has been done based on steady-state assumptions to determine important design parameter including the elevation of components and required heat transfer area of the condenser tube. Assuming a decay power level of 2%, the required heat transfer area for 1,000MWe plant is assessed to be about 2,000 ㎡ (equivalent to 1,600 of 10 m-long, 4-cm-OD tubes) with the relative elevation difference of 38 m between the condenser and steam condensing pool and the riser diameter of 0.62 m.

  • PDF

마이크로 세라믹 윅을 사용한 루프 히트파이프의 특성 연구 (Characteristic Studies on Loop Heat Pipe with Micro Ceramic Wick)

  • 박종찬;이충구;이석호
    • 대한기계학회논문집B
    • /
    • 제31권10호
    • /
    • pp.823-831
    • /
    • 2007
  • This paper presents the experimental and simulation study of a loop heat pipe (LHP) that can be applied to present electronics, space missions and thermal control systems. The present experimental study was carried out employing sintered alumina ceramic wick ($d=2.96\;{\mu}m$, ${\phi}=0.61$). High purity R-134a, R-22 and water were also used as alternative working fluids in addition to ammonia. The experimental study showed that the maximum heat transfer performance for the test LHP in the vertical top heating mode was over 100 Watts when ammonia was used as the working fluid. The simulation results have been compared with the experimental results to validate a simulation model based on the thermal resistance network that was developed to evaluate the performance of LHPs, focusing on their prospective applications in electronics. The simulation model is based on the loop overall energy, mass, and momentum balance. The simulation program can predict the effects of various parameters which affect the performance of LHP within 5% compared with the experimental results.

EPR Study of${\gamma}(1,2)-[H{_n}SiV^{IV}VW_{10}O_{40}]^{(7-n)-}$ (n = 0, 1 or 2). Identification of Four One-Electron Reduction Products and Evidence for Proton Transfer in the Solid State

  • Jeongmin Park;Hyunsoo So
    • Bulletin of the Korean Chemical Society
    • /
    • 제15권9호
    • /
    • pp.752-758
    • /
    • 1994
  • Several one-electron reduction products of ${\gamma}$(1,2)-[$H_nSiV_2W_{10}O_{40}]^{(6-n)-}$ were separated by precipitating or coprecipitating with diamagnetic host compounds at different pH. Mono-and diprotonated species, 1 and 2, in powder samples exhibit aPR spectra characteristic of a mononuclear oxovanadium species, indicating that the unpaired electron is trapped at one vanadium atom. The EPR spectrum of the unprotonated species 0 shows 15 parallel lines, indicating that the unpaired electron interacts equally with two vanadium atoms. While different species were precipitated depending upon the pH of the solution and the charge of the host anion, only one species 1' was formed in the frozen solutions at pH 3.2-4.7. The EPR spectrum of 1' indicates that the unpaired electron is trapped at one vanadium atom and 1/16 of the spin density is delocalized onto the second vanadium atom. The species 1' is probably another form of the monoprotonated species. The EPR spectra show that some of 2 transform into 1 and some of 0 transform into 1' in the solid state at low temperatures. It is suggested that proton transfer between the heteropolyanion and water molecues in the solid state is involved in these transformations.

물-공기 혼합분무에 의한 고온 강판 냉각에 대한 연구 (I) -막비등 열전달에 대한 공기질량유속의 영향- (A Study on Cooling of Hot Steel Surface by Water-Air Mixed Spray(I) -The Effect of Air Mass Flux on Film Boiling Heat Transfer-)

  • 이필종;진성태;이승홍
    • 대한기계학회논문집B
    • /
    • 제28권3호
    • /
    • pp.247-255
    • /
    • 2004
  • The cooling characteristic of water-air mixed spray for high water mass flux is not well defined, compared to that of highly pressurized spray. A series of research program was planned to develop the boiling correlation for whole temperature range in case of water-air mixed spray with high water mass flux. The cooling experiments of hot steel surface with initial temperature of 820$^{\circ}C$ were conducted in unsteady state with relatively high water mass flux. A computer program was developed to calculate the heat flux inversely from measured data by three inserted thermocouples. Finally the effects of water and air mass flux on the averaged film boiling heat flux and wetting temperature were studied. In this 1st report, it is found that the boiling curve was similar to that of highly pressurized spray and the decreased slope of heat flux in film boiling region with respect to surface temperature became steep by increasing air mass flux. Also it is shown that, by increasing air mass flux, the averaged heat flux in film boiling region was increased, and then saturated and the wetting temperature was increased, and then decreased. Finally when the heat flux in film boiling region is compared with that of highly pressurized spray, it is known that the cooling is improved by introducing air up to 60%.

설비공학 분야의 최근 연구 동향: 2011년 학회지 논문에 대한 종합적 고찰 (Recent Progress in Air-Conditioning and Refrigeration Research: A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2011)

  • 한화택;이대영;김서영;최종민;백용규;김수민
    • 설비공학논문집
    • /
    • 제24권6호
    • /
    • pp.521-537
    • /
    • 2012
  • This article reviews the papers published in the Korean Journal of Air-Conditioning and Refrigeration Engineering during 2011. It is intended to understand the status of current research in the areas of heating, cooling, ventilation, sanitation, and indoor environments of buildings and plant facilities. Conclusions are as follows. (1) Research trends of thermal and fluid engineering have been surveyed as groups of fluid machinery and fluid flow, thermodynamic cycle, and new and renewable energy. Various topics were presented in the field of fluid machinery and fluid flow. Research issues mainly focused on the rankine cycle in the field of thermodynamic cycle. In the new and renewable energy area, researches were presented on geothermal energy, fuel cell, biogas, reformer, solar water heating system, and metane hydration. (2) Research works on heat transfer area have been reviewed in the categories of heat transfer characteristics, pool boiling and condensing heat transfer, nanofluids and industrial heat exchangers. Researches on heat transfer characteristics included heat transfer above liquid helium surface in a cryostat, methane hydrate formation, heat and mass transfer in a liquid desiccant dehumidifier, thermoelectric air-cooling system, heat transfer in multiple slot impinging jet, and heat transfer enhancement by protrusion-in-dimples. In the area of pool boiling and condensing heat transfer, researches on pool boiling of water in low-fin and turbo-B surfaces, pool boiling of R245a, convective boiling two-phase flow in trapezoidal microchannels, condensing of FC-72 on pin-finned surfaces, and natural circulation vertical evaporator were actively performed. In the area of nanofluids, thermal characteristics of heat pipes using water-based MWCNT nanofluids and the thermal conductivity and viscosity were measured. In the area of industrial heat exchangers, researches on fin-tube heat exchangers for waste gas heat recovery and Chevron type plate heat exchanger were implemented. (3) Refrigeration systems with alternative refrigerants such as $CO_2$, hydrocarbons, and mixed refrigerants were studied. Heating performance improvement of heat pump systems were tried applying supplementary components such as a refrigerant heater or a solar collector. The effects of frost growth were studied on the operation characteristic of refrigeration systems and the energy performance of various defrost methods were evaluated. The current situation of the domestic cold storage facilities was analyzed and the future demand was predicted. (4) In building mechanical system fields, a variety of studies were conducted to achieve effective consumption of heat and maximize efficiency of heat in buildings. Various researches were performed to maximize performance of mechanical devices and optimize the operation of HVAC systems. (5) In the fields of architectural environment and energy, diverse purposes of studies were conducted such as indoor environment, building energy, and renewable energy. In particular, renewable energy and building energy-related researches have mainly been studied as reflecting the global interests. In addition, various researches have been performed for reducing cooling load in a building using spot exhaust air, natural ventilation and energy efficiency systems.

초음파 스케일 방지를 위한 전자구동기법에 관한 연구 (A Study of Electronic Generation Technique for the Scale Prevention Using Ultrasonic Waves)

  • 허필우;이양래;김재형;임의수
    • 연구논문집
    • /
    • 통권26호
    • /
    • pp.51-56
    • /
    • 1996
  • In the case of a heat exchanger, scale is made in the tube by the chemical reactions of Ca and Mg ions contained in the water, and heat transfer rate is reduced because of increment of heat resistance in the pipe of the heat flow. Thus it brings to reduce the energy efficiency and to make environmental pollution by the use of chemicals for the prevention and removement of scale. In this paper, we discussed the design of electronic generator for ultrasonic scale preventor and analyzed the fundamental characteristic for ultrasonic transducer.

  • PDF

IC 칩 냉각용 초소형 히트 파이프의 제작 및 성능 평가 (Fabrication and Characteristics Test of Micro Heat Pipe Array for IC Chip Cooling)

  • 박진성;최장현;조형철;조한상;양상식;유재석
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제50권7호
    • /
    • pp.351-363
    • /
    • 2001
  • This paper presents an experimental investigation on the heat trensfer characteristic of micro pipe (MHP) array with 38 triangular microgrooves. A heat pipe is an effective heat exchanger operating without external power. The heat pipe transfers heat by means of the latent heat of vaporization and two-phase fluid flow driven by the capillary force. The overall size of the MHP array can be put undermeath a microelectonic die and integrated into the electrronic package of a microelectronin device to dissipate the heat from the die. The MHP array is fabricated by micromachining with a silicon wafer and a glass substrate. The MHP was filled with water and sealed. The experimental results show the temperature decrease of 12.1$^{\circ}C$ at the evaporator section for the input power of 5.9 W and the improvement of 28% in the heat transfer rate.

  • PDF

Study of point defects caused by a thin contamination layer in a-Si TFT-LCD

  • Oh, Jae-Young;Lee, Jae-Kyun;Yang, Moung-Su;Kang, In-Byeong
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2007년도 7th International Meeting on Information Display 제7권1호
    • /
    • pp.845-848
    • /
    • 2007
  • Analysis of point defects invisible by a microscope has been studied on the a-Si thin film transistor panel. The point defects which were named Invisible Point Defect (IPD) is characterized by no particles or distortion of patterns on a pixel structure and randomly distributed on panels. To investigate the IPD, measurements were carried out: gray level driving, transistor transfer characteristic, focused ion beam (FIB), and secondary ion mass spectrometry (SIMS). The results showed that a contamination layer had a bad influence on an active surface. The contamination layer consisted of oxygen and iron from a water supply line during cleaning process. After the process tuning, IPD has been stabilized.

  • PDF

Influence of head structure on hydrodynamic characteristics of transonic motion projectiles

  • Wang, Rui;Yao, Zhong;Li, Daqin;Xu, Baocheng;Wang, Jiawen;Qi, Xiaobin
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • 제12권1호
    • /
    • pp.479-490
    • /
    • 2020
  • The hydrodynamic characteristic of transonic motion projectiles with different head diameters are investigated by numerical simulation. Compressibility effect in liquid-phase water are modeled using the Tait state equation. The result shows that with increasing of velocity the compression waves transfer to shock waves, which cause the significant increasing of pressure and decreasing the dimensions of supercavities. While the increasing of head diameter, the thickness, the vapor volume fraction and the drag coefficient of supercavities are all enhanced, which is conducive to the stability of transonic-speed projectiles. The cavity dynamics of the different head projectiles are compared, and the results shows when Mach number is in high region, the truncated cone head projectile is enveloped by a cavity which results in less drag and better stability.

LNG선박 열교환기 세관의 SCC에 미치는 용액의 온도의 영향 (The Effect of Temperature on SCC of Heat Exchanger Tube for LNG Vessel)

  • 정해규;임우조
    • 한국가스학회지
    • /
    • 제8권1호
    • /
    • pp.1-6
    • /
    • 2004
  • 선박용 열교환기의 냉각수로 사용되고 있는 해수의 입구온도는 스팀터빈콘덴서의 경우 약 $25^{\circ}C$이고 출구온도는 약 $60^{\circ}C$이며, 오일쿨러의 경우 출구온도는 약 $40^{\circ}C$이다. 이러한 해수의 온도 변화는 열교환기 세관재의 부식특성에 크게 영향을 미친다. 그러므로 부식손상을 최소화하면서 열교환 효율을 최대로 유지할 수 있는 냉각용액의 온도설정은 매우 중요하다. 따라서 본 연구에서는 $3.5\%$ NaCl + $0.1\%\;NH_4OH$ 수용액의 유동하에서 선박용 열교환기 세관재로 사용되고 있는 Al-황동의 분극 및 응력부식균열 실험을 실시하여 분극특성, 응력부식균열거동 및 탈아연특성에 미치는 용액의 온도의 영향에 대하여 고찰하였다.

  • PDF