• 제목/요약/키워드: Water tank experiments

검색결과 265건 처리시간 0.024초

FLOW CHARACTERISTICS OF A TWO-DIMENSIONAL NEUTRALLY BUOYANT JET IN A MODEL SETTLING TANK

  • Kim, Young-han;Seo, Il-Won;Ahn, Jung-kyu
    • Water Engineering Research
    • /
    • 제2권1호
    • /
    • pp.21-31
    • /
    • 2001
  • In this study, laboratory experiments were performed to investigate the flow characteristics of a two-dimensional neutrally buoyant jet in the inlet region of a rectangular laboratory settling tank. Velocity measurements were made with a three-component ADV. Two types of baffles were installed in front of two-dimensional slot; a one-sided and a two-sided baffle. The flow fields from a plane jet impinging on these two types of baffles and a plane jet without a baffle showed quite different characteristics. To concentrate on investigating these flow characteristics, the effects of density currents due to temperature difference or the presence of sediments were not studied. Results of the experiments reveal that the use of the two-sided baffle results in the shortest inlet region. Also shown is that, in addition to the types of baffles, the Froude number turns out to be an important factor in the extent of the inlet region.

  • PDF

수중 하베스트형 빙축열 시스템의 운전특성 실험 (Experiments on Operation Characteristics of In-Water Harvest-Type Ice Storage System)

  • 최인수;김재돌;윤정인
    • 대한기계학회논문집B
    • /
    • 제25권5호
    • /
    • pp.653-659
    • /
    • 2001
  • This paper is concerned with the development of a new method for making and separating ice in-water and saving floated ice by installing an evaporation panel in an ice storage tank. The new method shows very good heat transfer efficiency than that of the convectional method. It is because the evaporation panel is directly contacted with water in the storage tank. The experiments were performed by varying inlet and outlet refrigerant temperatures of its evaporator. From the experimental results, the operating characteristics of in-water harvest-type ice storage system were investigated by measuring temperature and pressure at each point of the ice storage system and power required to operating compressor respect to the changes of the inlet and outlet refrigerant temperature of evaporator. It can be think that defrost frequency decreased and heavy ice created as the refrigerant temperature of evaporator outlet and defrost setting temperature is low so gotten result can effect to release efficiency. Also, consumption power, condensing heat quantity, refrigerating capacity and performance efficiency decreased as time goes by. Therefore, these results provide the basic data for system optimization, performance improvement and the possibility of application to other fields.

지하 빗물저류시설의 설치에 따른 유출 저감 효과 분석 (Reduction Rate of the Total Runoff Volume though Installing a Rainfall Storage Tank in the Sub-Surface)

  • 최계운;최종영;이진원
    • 한국수자원학회논문집
    • /
    • 제36권3호
    • /
    • pp.455-464
    • /
    • 2003
  • 본 연구에서는 지하 빗물저류시설 설치에 따른 유출저감 효과를 분석하기 위하여 실험실내 모형 빗물저류장치를 설치하여 강우강도 변화, 표층의 피복상태 변화, 표면경사 변화에 따른 유출량 변화 실험을 실시하였다. 실험결과 대상하천인 승기천의 토양조건하에서 강우강도가 40mm/hr-100mm/hr일 때 총유출량 감소는 42.3-52.9%로 나타났으며, 지하 빗물저류시설을 설치하는 경우 총유출량과 첨두유량의 감소를 가져올 수 있을 것으로 판단된다. 경사변화에 따른 총유출량의 변화는 완만한 경사에서는 매우 크게 나타났으나 3%이상의 급경사에서 침투에 의한 저류량에 변화가 적고, 이는 산지와 같은 급경사지역에 빗물저류시설을 설치하는 경우 장기간의 홍수에 대하여 상당한 효과를 나타내는 것으로 나타났다. 따라서, 본 시스템은 하천이나 산지의 급경사에도 큰 결과를 기대할 수 있다.

성층 축열 시스템에서의 열 저장 특성에 관한 실험적 연구 (An experimental study on thermal storage characteristics in the thermally stratified water storage system)

  • 고재윤;김영기;이채문;임장순
    • 한국태양에너지학회 논문집
    • /
    • 제21권4호
    • /
    • pp.37-46
    • /
    • 2001
  • This study describes the experimental study that focuses on the effects that distributor shapes and flow rate variations have an influence on the stratification in a rectangular thermal storage tank. Experiments were carried out under the conditions that the flow rates of working fluid are 20, 10 and $5\ell$/min. The storage tank is initially filled with chilled water of $1^{\circ}C$, and is extracted through the bottom at the same rate as the return warm water from load is entered through the distributor at the top of the tank. The thermo-cline forms at the top of the storage tank as the warm water enters the tank from the load through the distributor and the thermo-cline thickness increases with time. Emphasis is given to the effects of mixing at the inlet that increases the thermo-cline decay Flow rate variation and inlet distributor shapes are the important parameters in deciding the performance of a storage system. Stratification degree increases with decreasing in inlet flow rate under $10\ell$/min. Experiments shows that better thermal stratification can be obtain using the distributor to limit momentum mixing at the inlets and outlets. Also, 12% of improvement in the thermal energy usage has been achieved using the modified distributor discharging same flow rate in each lateral ports.

  • PDF

A Study on the Viscous Damping Effect According to the Shape of the Inclined OWC Chamber Skirt

  • Jung, Hyen-Cheol;Koo, Weoncheol
    • 한국해양공학회지
    • /
    • 제36권4호
    • /
    • pp.270-279
    • /
    • 2022
  • In this study, numerical analysis and experiments were performed to analyze the viscous damping effect according to the shape of the chamber skirt of the breakwater-linked inclined oscillating water column wave energy converter. Experiments were conducted using a two-dimensional mini wave tank and verified by comparing the results of a computational fluid dynamics numerical analysis. Pointed and rounded skirts were modeled to compare the effect of viscous damping when incident waves enter the chamber, and the difference in the displacement of the water surface in the chamber was compared according to the wave period for the two skirt shapes. The wave elevation in the chamber in the rounded-skirt condition was larger than the pointed-skirt condition in all wave periods, which was approximately 47% greater at 0.9 s of the incident wave period. Therefore, extracting the maximum energy through the optimal orifice is possible while minimizing the energy attenuation in the rounded-skirt condition.

양어사육수를 이용한 사경재배 (Sand Culture Using Recirculated Aquaculture Water)

  • 김기덕;이병일;강용구;문보흠;홍상근;홍석우;배용수
    • 한국유기농업학회지
    • /
    • 제8권1호
    • /
    • pp.79-88
    • /
    • 1999
  • In order top investigate the growth of water dropwort grown by sandculture irrigated with recirculated tilapia aquaculture water, these experiments were carried out. Fish(tilapia) production and biofiltration provided by sand cultured water dropwort(Oenanthe stolonifera DC.) were linked in a closed system of recirculation water. Water dropwort was irrigated with water drawn from the tilapia tank and drainage from sand beds was returned to the fish tank. The temperature, pH and EC of tilapia culture water were stable. The growth of water dropwort grown by sandculture with aquaculture water was normal. Microbial activity of the biofilterbed irrigated by tilapia rearing water was higher than that of biofilterbed irrigated by tapwater. The feasibility of an integrated, recirculatory system for concurrent production of water dropwort and fish with no additional fertilization application was demonstrated.

  • PDF

수조를 이용한 조력발전량산정에 관한 실험적 연구 (The Experimental Study on the Evaluation of Tidal Power Generation Output Using Water Tank)

  • 정신택;김정대;고동휘;최우정;오남선
    • 한국해안·해양공학회논문집
    • /
    • 제20권2호
    • /
    • pp.232-237
    • /
    • 2008
  • 소규모 수조를 이용한 조력발전시스템에 대하여 검토하였다. 이를 위하여 소규모 수조를 제작하고 시간에 따른 수위의 변화를 관측한 후 이를 이론적인 계산값과 비교하였다. 수조는 내부수조와 외부수조로 제작하여 창조발전과 낙조발전의 개념을 재현할 수 있도록 하였다. 또한 내부수조와 외부수조의 연결관을 두 곳에 설치하여 유량을 변화시키며 실험을 하였다. 관측된 수위의 변화를 계산값과 비교하여 유량계수를 산출하였다. 수위의 관측치와 이론적인 계산치는 높은 상관관계를 갖는 것으로 나타나 이론식이 실제의 수위를 잘 모의하는 것으로 나타났다. 프로펠러의 유무, 밸브의 유무, 창조 발전, 낙조 발전 등에 따라 유량계수가 큰 변화를 보이는 것으로 나타나 실제 발전시스템을 제작할 때 실험을 통한 유량계수 등의 산정이 반드시 필요한 것으로 나타났다. 또한 이론적인 식에 의한 총에너지와 실험유량으로부터 계산된 총에너지를 비교한 결과 큰 차이가 없는 것으로 나타났다. 본 수조에 대하여 계산된 발전량은 크지 않으나 충분한 조차가 있는 곳에 적정 규모의 수조를 설치할 경우 소규모의 조력발전이 가능하여 신재생에너지 생산에 기여할 것으로 판단된다.

온도 변화에 따른 수돗물 저장 저수조 내 잔류염소에 관한 수학적 모형 시뮬레이션 (Mathematical Model Simulations Assessing the Effects of Temperature on Residual Chlorine Concentrations in Water Storage Tanks)

  • 노유래;박준홍
    • 한국물환경학회지
    • /
    • 제33권2호
    • /
    • pp.187-196
    • /
    • 2017
  • To ensure hygienic safety of drinking water in a water storage tank, the concentrations of residual chlorine should be above a certain regulation level. In this study, we conducted model simulations to investigate the effects of temperature on residual chlorine in water storage tank conditions typically used in Seoul. For this, values of model parameters (decomposition rate constant, sorption coefficient, and evaporation mass transfer coefficient) were experimentally determined from laboratory experiments. The model simulations under continuous flow conditions showed that the residual chlorine concentrations were satisfied the water quality standard level (0.1 mg/L) at all the temperature conditions ($5^{\circ}C$, $10^{\circ}C$, $15^{\circ}C$, $20^{\circ}C$ and $25^{\circ}C$). Meanwhile, when the tanks had a no flow condition (i.e., no tap-water influent due to a sudden shut-down), the concentrations became lower than the regulatory level after certain periods. The findings from this modeling works simulating Seoul's water storage tanks suggested disappearance rate of residual chlorine could be reduced through the tanks design optimization with maintenance of low water temperature, minimization of air flow and volume, suppression of dispersion and the use of wall materials with low sorption ability.

BPSK 변조를 이용한 수중 음향 통신의 실험적 고찰 (Experimental Results of an Underwater Acoustic Communications using BPSK Modulation)

  • 주형준;전재국;김기만
    • 한국마린엔지니어링학회:학술대회논문집
    • /
    • 한국마린엔지니어링학회 2005년도 전기학술대회논문집
    • /
    • pp.454-458
    • /
    • 2005
  • In this paper we analyzed the performance of data transmission using BPSK modulation. The system performances were evaluated by the experiments in water tank. As a result we showed the influences of reverberation due to the multipath. In order to simplify the experiment procedure the channel coding etc. were omitted. The experimental result shows that the maximum transmission data rate in used water tank is about 350 bps at bit error rate of $10^{-3}$.

  • PDF

유입하수에 따른 BNR에서의 N과 P 제거율에 관한 연구 (Removal Ratio of Nitrogen & Phosphorus according to Sewage Inflow in the Biological Treatment(Biological Nutrient Removal)Process)

  • 이한섭;정광보;안성환;김경호;원성권
    • 한국응용과학기술학회지
    • /
    • 제31권4호
    • /
    • pp.669-678
    • /
    • 2014
  • The amount of waste water generated from the domestic sources is consistently increasing in proportion to economic growth, and the conventional activated sludge process is widely being used for general waste water treatment. But the ministry of environment becomes stringthent treatment standards of N and P (less than 20mg/L of N, 2mg/L of P) to prevent the eutrophication of lake water, and therefore highly advanced treatment technology is required not only in the existing treatment plants where the activated sludge process is being used, but also in newly constructed treatment plants for the treatment of N and P. This study is aimed at highly operating the engineering technology method was developed by domestic to eliminate N and P at the same time. Experiments were conducted in the treatment plant located in Yong In city. The bioreactor was started from the principal equipment for the elimination of N and P and the elimination of organic compounds. It consists of an internal recycle piping from the end of the aerobic tank to the anoxic tank and external recycle piping from the final settling basin to the denitrification tank. By experiment of 4 types separate inflow of waste water to the denitrification tank and the anaerobic tank, and changes in staying time at the anoxic tank and the aerobic tank, the elimination of organic compounds in each type and the relationship in the efficiency between the elimination of N and P were researched.