• 제목/요약/키워드: Water system

검색결과 18,206건 처리시간 0.043초

SWG 추진을 위한 다중수원 워터루프 시스템 관련 법제도 개선방안 (Legal Improvements for SWG Application Relevant to the Water Loop System with Multi-Water Resources)

  • 서진석;김영화;한국헌;김동환
    • 한국관개배수논문집
    • /
    • 제21권1호
    • /
    • pp.127-140
    • /
    • 2014
  • Recently drastic climate changes(e.g., extreme floods and droughts) are often taking place around the world. Even an increase in uncertainty, population, and mega cities has caused drastic changes in water recycle process. As in other countries, Korea has faced some issues relevant to water security. In response to these changes, Smart Water Grid(SWG) system combining the current water resources management with ICT (Information and Communications Technology) is considered as a new paradigm for the Korean water resources management. This study aims to explore and identify influential factors contributing to the SWG system's application to analyze the importance and role of those factors, and then to offer a policy suggestion for the successful application of the SWG system along with legislative improvements in Korea. In this study, we looked at different barriers related to the SWG application and also the complicated Korean water laws, enacted by different ministries and in order to efficiently apply the SWG system to the current Korean water resources management structures. This study employed qualitative research methods to analyze and identify the priorities of the tasks to be implemented by analyzing conditions for the SWG application, especially related to multi water sources and micro water grid, because legal and institutional measures can be more important to manage conflicts between different stakeholders once the SWG enters a phase of standardization and commercialization from its development stage.

  • PDF

A Technology for Water Pollution Diffusion Prevention based on Web Map

  • Shin, Jin Seob
    • 한국컴퓨터정보학회논문지
    • /
    • 제22권11호
    • /
    • pp.65-71
    • /
    • 2017
  • An integrated water environment management system is necessary in improving water quality, properly allocating water resources, and supporting socio-economic development. Specifically, water quality management system using web map can be an efficient approach to accomplish this system. This paper aims to construct a dynamic water quality management system to reflect a water environment management system which includes three sub-models with consideration of their interrelationships (a socio-economic model based on dynamic Input-Output model, a water resources cycle model, and a water pollutants flow model). Based on simulation, the model can precisely estimate trends of water utilization, water quality, and economic development under certain management targets, and propose an optimal plan. This study utilized the model to analyze the potential of using reclaimed water to accomplish local water environment management and sustainable development plan while exploring the applicable approaches. This study indicates that the constructed water environment management system can be effective and easily adopted to assess water resources and environment while improving the trade-off between economic and environment development, as well as formulate regional development plan.

데이터센터 냉방시스템 고효율화를 위한 국내 수열에너지 보급 제도 개선에 관한 연구 (A Study on the Improvement of the Water Source Energy Distribution Regulation for High Efficient Data Center Cooling System in Korea)

  • 조용;최종민
    • 한국지열·수열에너지학회논문집
    • /
    • 제17권3호
    • /
    • pp.21-29
    • /
    • 2021
  • In this study, the current regulation of the water source energy, one of the renewable energy, was analyzed, and the improvement plan for the high efficient data center cooling system was suggested. In the improvement plan, the design and construction guidelines of the water source energy system permit to adopt the cooling and heating system with or without heat pump. In addition, it should also include the system operated in the cooling mode only all year-round. The domestic test standards to consider the water source operating conditions should be developed. Especially, it is highly recommended that the test standards to include the system with forced cooling and free cooling modes related with the enhanced data center cooling system adopting the water source energy.

극지운항용 빙해선박의 밸러스트 수 결빙방지 기법 연구 (A Study on Anti-Icing Technique for Ballast Water of Icebreaking Vessels Operating in Ice-Covered Water)

  • 정성엽;이춘주;조성락
    • 대한조선학회논문집
    • /
    • 제48권1호
    • /
    • pp.93-97
    • /
    • 2011
  • When freezing is present on ballast water, it can impose additional loads on the hull and effect on stabilization of ship. The anti-icing techniques of ballast water, therefore, are key criteria for ship safety. The existing anti-icing techniques of ballast tank are hull heating, water circulation and air bubble system etc. In this research, anti-icing performance tests for the ballast water using micro-bubble system and sea water circulation system have been carried out at two temperature conditions($-10^{\circ}C$ and $-25^{\circ}C$). Ambient temperature, sea water temperature and temperature of the inner parts of the ballast tank are measured and also ballast water conditions are checked during the model test. The applied anti-icing techniques of ballast water, such as micro-bubble system and sea water circulation system show good performance in the low temperature conditions.

청라지구 물순환체계내 주운수로의 흐름유발시설 설치효과 (The Effect of Flow Induction Machine in Water Circulation System of Cheongna Canal Way)

  • 김동언;최계운;박영식;윤근호
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 2010년도 학술발표회
    • /
    • pp.77-81
    • /
    • 2010
  • This study carried out hydraulic model test for water circulation system in Cheongna district as part of Incheon Free Economic Zone. Canal way project of Cheongna was planned to establish for environment-friendly water circulation system, improve quality of life and diversification of traffic through using boat as a water-friendly international business city. The navigation canal, There are two intake facility in central park and it can purify water 15,000$m^3$ per day. After purify, water move to 8 facility of water culture area which supplies water in canal way. This process called water circulation system in cheongna. Also, there are several flow induction machine in canal way except south-north way. Therefore, this study will verify about validity of water circulation system's safety through hydraulic model test.

  • PDF

Strengthen the Construction of Water Resources Monitoring Ability, Support the Strictest System of Water Resources management

  • Jiang, Yun-Zhong;Yi, Wan
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 2012년도 학술발표회
    • /
    • pp.27-33
    • /
    • 2012
  • At present, the overall water resources monitoring ability in China is weak since there is an absence of a sound monitoring system and comprehensive monitoring information. In addition to the problem of weak management ability in monitoring, measurement and information, it can hardly meet the need of implementing the strictest management system of water resource and also restricts the practice of the system to some extent. The production states the necessity of further development of water resources monitoring ability and points out the concept of "One Country, One Account" for constructing water resources information. There is an analysis on the demand on further development of water resources monitoring ability and profound discussion about the strategies for supporting "three red-line" management.

  • PDF

급수관로계에 설치된 수격흡수기의 수격흡수효과에 관한 실험적 연구 (Experimental Study on the Water Hammer Absorption Effects of Water Hammer Arrester in the Water Supply Piping System)

  • 최중근;이석종;이명호;성재용
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제30권3호
    • /
    • pp.396-402
    • /
    • 2006
  • In this study, dynamic characteristics of water hammer pressure in water supply piping system with water hammer arrester has been investigated experimentally to characterize the transient pressure of water hammer in high rise building. Experiments were conducted to verify the absorption effects by water hammer arresters with 3 different gas volumes of water hammer pressure generated by sudden valve closure. As the results, it has been found that zoning and sizing of pipe diameter for suitable flow velocity and water hammer arresters with effective pressure absorption capacity have to be installed to protect water hammer problems in building water supply piping system.

기후변화 대응을 위한 수처리 여과시스템 선정 방안 연구 (Study on Selection of Water Treatment Filtration System to Cope with Climate Change)

  • 황윤빈;박기학
    • 한국기후변화학회지
    • /
    • 제9권1호
    • /
    • pp.75-80
    • /
    • 2018
  • The problem of water shortages and water related disasters caused by climate change has increased the seriousness of water problems and the importance of water treatment technology capable of securing clean water is expanding. In this study, we analyzed not only the water pollutant generated by the filtration system technology of various water treatment technologies but also the indirect greenhouse gas emissions generation, and analyzed the influence on the environment. The subjects of study are Fabric Filter, Reverse Osmosis System and Pressurized Microfiltration Device which are widely used for water treatment and we analyzed the impact on the environment using the Life Cycle Assessment (LCA) method using the electricity amount necessary for use, the water purification efficiency, the throughput per ton and the cost. The amount of greenhouse gas generated when the Pressurized Microfiltration Device operates for 1 year is $2.15E+04kg\;CO_2-eq$., Fabric Filter is $3.29E+04kg\;CO_2-eq$., and Reverse Osmosis System is $1.68E+05kg\;CO_2-eq$. As a result of analyzing the amount of greenhouse gas generated at the time of purifying 1 ton of the Pressurized Microfiltration Device and the conventional filtration system, the Pressurized Microfiltration Device was $20.5g\;CO_2-eq$., Fabric Filter was $34.7g\;CO_2-eq$., and Reverse Osmosis System was $191.7g\;CO_2-eq$. The amount of greenhouse gas generated was calculated to be 41.0% less than that of the Fabric Filter by the Pressurized Microfiltration Device and 89.3% less than the Reverse Osmosis System. From the viewpoint of climate change, it is necessary to select a filtration system that takes climate change into account, not from the viewpoint of water quality removal efficiency and economic efficiency according to future water treatment applications, and it is necessary to select a water treatment filtration system more researches and improvements will be made for.

시설용수 및 영농편의용수 공급시스템 개발 (I) - FDA 시스템 개발 - (Development of Clean Water Supplying System for Greenhouse Cultivation and Convenience Water (I) - Development of the FDA System -)

  • 이광야;최경숙
    • 한국농공학회논문집
    • /
    • 제51권5호
    • /
    • pp.95-100
    • /
    • 2009
  • The water purification systems have been hardly used for agricultural purpose due to their complicated compositions and high costs for farmers, while only simple filtrations have been applied to irrigation systems in order to prevent the system from clogging problems. This study therefore developed a clean water supplying system, the Filter-Disinfection-Adsorption (FDA) system, especially for greenhouse cultivation of where low quality of water is available. This system has also been produced for providing convenience water to farmers in the areas of no water supply service systems for the purpose of washing their bodies or agricultural machineries after farm work. The FDA system consists of three stages of purification processes with an integral module, including disk and teflon filtrations and Ultraviolet (UV) sterilization processes. Indoor experiments were undertaken with a trial product of the FDA system to test its performance. The operation test of the process was performed as well as the condition check of each item including UV module, filters, control panel, pump, valves, etc. The results shows good performance of each test with no critical problems. The initial and maintenance costs were also analysed with other purification systems. From the comparisons, the FDA system found to be very economical and easy to use.

Development of Water Supply System under Uncertainty

  • Chung, Gun-Hui;Kim, Tae-Woong;Kim, Joong-Hoon
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 2009년도 학술발표회 초록집
    • /
    • pp.2179-2183
    • /
    • 2009
  • As urbanization is progressed, the network for distributing water in a basin become complex due to the spatial expansion and parameter uncertainties of water supply systems. When a long range water supply plan is determined, the total construction and operation cost has to be evaluated with the system components and parameter uncertainties as many as possible. In this paper, the robust optimization approach of Bertsimas and Sim is applied in a hypothetical system to find a solution which remains feasible under the possible parameter uncertainties having the correlation effect between the uncertain coefficients. The system components to supply, treatment, and transport water are included in the developed water supply system and construction and expansion of the system is allowed for a long-range period. In this approach, the tradeoff between system robustness and total cost of the system is evaluated in terms of the degree of conservatism which can be converted to the probability of constraint violation. As a result, the degree of conservatism increases, the total cost is increased due to the installation of large capacity of treatment and transportation systems. The applied robust optimization technique can be used to determine a long-range water supply plan with the consideration of system failure.

  • PDF