• 제목/요약/키워드: Water supply line

검색결과 104건 처리시간 0.035초

비상시 용수공급을 위한 상수도 연계관로의 수리적 적정성 평가 (Hydraulic Adequacy of Connection Pipes in Water Supply Systems for Contingencies)

  • 한완섭;정관수;김주환
    • 상하수도학회지
    • /
    • 제27권6호
    • /
    • pp.679-687
    • /
    • 2013
  • Although stable and safe drinking water supply to the customers is a basic function of multi-regional water supply systems in Korea, most systems have their vulnerabilities in emergency time due to the branch-type. Application of connections from the other water supply system can provide a solutions for these tentative problems. This paper describes reduction planning of water supply accidents that can minimize a service interruption to customers in multi-regional water supply system by connecting pipe lines between local water supply systems in Mokpo city areas. The result of this study shows that Juam dam multi-regional water supply systems can cover all of the water shortage in southern parts of Jeonnam multi-regional water supply systems by transmitting water through connected pipes between local networks. This can be effective to supply water interactively in various contingencies, when a pipe line accident occurs in southern area of Jeonnam multi-regional water supply systems. On the contrary, southern area of Jeonnam multi-regional water supply systems can cover 99.5 %($62,500m^3/day$) of the water shortage of Juam dam multi-regional water supply systems when service interruptions caused by various pipe accidents occur in the system.

급수기구 발생음의 실험실 측정방법 제3부 : 직렬 밸브와 급수기구의 설치방법 및 작동조건 (Laboratory tests on noise emission from appliances and equipment used in water supply installations Part 3: Mounting and operating conditions for in-line valves and appliances)

  • 정갑철;양관섭;박현구;김선우
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2004년도 추계학술대회논문집
    • /
    • pp.986-989
    • /
    • 2004
  • The method of measurement for laboratory tests on noise emission from appliances and equipment used in water supply installations is specified in ISO 3822-1 This part of standard gives detailed descriptions for mounting and operating in-line valves and appliances, which control the flow, pressure or temperature of the water in water supply installations in such laboratory tests.

  • PDF

위기대응 취약성 분석을 통한 광역상수도 연계운영 평가 (Evaluation for conjunctive operation of multi-regional water supply system through risk analysis)

  • 황진수;최태호;홍공현;이두진;구자용
    • 상하수도학회지
    • /
    • 제33권4호
    • /
    • pp.269-279
    • /
    • 2019
  • This study would present a risk analysis method to evaluate stable tap water supply in a multi-regional water supply system and propose a measure for the evaluation of the effect of the conjunctive operation of the multi-regional water supply system using this. Judging from the vulnerability for the crisis response of the entire N. multi-regional water supply system, as compared to the result of Scenario 1 in which no conjunctive pipes were operated, it was found that in Scenario 2, in which conjunctive pipes were partially operated, the vulnerability of crisis response decreased by about 30.6%, and as compared to Scenario 3, the vulnerability of crisis response decreased by 86.2%. In setting a plan for stable tap water supply in N multi-regional water supply system, using the estimated value and the method for the evaluation of the vulnerability of crisis response by pipe, by interval and by line, it is judged that this can be utilized as a basis for the judgment of the evaluation of the operation or the additional installation of conjunctive pipes.

관로계통 및 가압펌프장 수격에 따른 최적 안정성 확보방안 (Application & Examination of the Plan for Optimum Stability through Water-hammer in Pipe Line and Booster Pump Station)

  • 라병필;박종호
    • 한국유체기계학회 논문집
    • /
    • 제12권5호
    • /
    • pp.19-24
    • /
    • 2009
  • This paper is performed to find out the stability of water-hammer in pipe line and pump station that is happened when additional water needs demanded. At first, the water supply construction project is planned to supply $6,000\;m^3/day$ through 17.9 km pipe line. But additional demand ($1,200\;m^3/day$) happened from Cheong-ra water reservoir. In this situation, air-chamber($4\;m^3$) and vacuum breaker valve(${\varphi}100\;mm$) are needed to prevent water-hammer. When the additional water is supplied, the existing facilities (air-chamber, vacuum breaker valve) are sufficient to alleviate shock not changing capacity alteration, judging from the airspace change and rise. Therefore, there is no problem for water-hammer by installing air-chamber($4\;m^3$) and vacuum breaker valve(${\varphi}100\;mm$) at the top of Yeo-ju hill.

동결온도가 상수도관의 거동에 미치는 영향 (Behavior Characteristics of Water Supply Pipeline Due to Freezing Temperature)

  • 신은철;류병현;강현회;황순갑
    • 한국지반신소재학회논문집
    • /
    • 제13권4호
    • /
    • pp.1-10
    • /
    • 2014
  • 이 논문에서는 현장모형 실험을 통하여 동결온도에 따른 상수도관의 거동변형특성을 다루었다. 동결 온도 조건에 따라 상수도관에 미치는 동상압력과 Marston-Spangler 이론에 의한 동상 압력은 다소 차이를 나타내는 것을 보이며, Marston-Spangler이론만으로 관에 작용하는 하중을 고려하는 것은 안전측을 벗어날 수도 있다는 것을 염두 해야 한다. 또한 현장모형실험을 통한 상수도관의 변형률은 수치해석결과보다 작은 값을 나타내는 것을 확인하였다.

외기온도 변화에 따른 집단에너지 공동주택의 최적 열공급제어 알고리즘 개발에 관한 연구 (Study on the Development of Optimal Heat Supply Control Algorithm in Group Energy Apartment Building According to the Variation of Outdoor Air Temperature)

  • 변재기;이규호;최영돈;신종근
    • 설비공학논문집
    • /
    • 제23권5호
    • /
    • pp.334-341
    • /
    • 2011
  • In the present study, optimal heat supply algorithm which minimize the heat loss through the distribution pipe line in group energy apartment was developed. Variation of heating load of group energy apartment building in accord with the outdoor air temperature was predicted by the heating load-outdoor temperature correlation. Supply water temperature and mass flow rate were controlled to minimize the heat loss through distribution pipe line. District heating apartment building located in Hwaseong city, which has 1,473 households, was selected as the object building for testing the present heat supply a1gorithm. Compared to the previous heat supply system, 10.4% heat loss reduction can be accomplished by employing the present method.

지역난방 에너지 공동주택의 다중 열공급 제어 알고리즘 개발에 관한 해석적 연구 (Study on the Development of Multi Heat Supply Control Algorithm in Apartment Building of District Heating Energy)

  • 변재기;최영돈;박명호;신종근
    • 한국기계기술학회지
    • /
    • 제13권2호
    • /
    • pp.63-70
    • /
    • 2011
  • In the present study, we developed optimal heat supply algorithm which minimizes the heat loss through the distribution pipe line in group energy apartment. Heating load variation of group energy apartment building in accordance with outdoor air temperature was predicted by the correlation obtained from calorimeter measurements of whole households of apartment building. Supply water temperature and mass flow rate were conjugately controlled to minimize the heat loss rate through distribution pipe line. Group heating apartment located in Hwaseong city, Korea, which has 1,473 households divided in 4 regions, was selected as the object apartment for verifying the present heat supply control algorithm. Compared to the original heat supply system, 10.4% heat loss rate reduction can be accomplished by employing the present control algorithm.

제주특별자치도 상수도 기후위기 적응대책 연구 (A study on adaptation measures to climate crisis for water supply system of Jeju Special Self-Governing Province)

  • 김진근
    • 상하수도학회지
    • /
    • 제37권6호
    • /
    • pp.447-456
    • /
    • 2023
  • Risk assessment on Jeju Special Self-Governing Province(JSSGP)'s water supply facilities and establishment of adaptation measures for climate crisis factors were implemented. JSSGP's vulnerability to the climate crisis was high in the order of drought, heat wave, heavy rain and strong wind. As a drought adaptation measure, policies of water saving and revenue water ratio improvement were considered. As for the heat wave adaptation measure, the introduction of an advanced water treatment process was suggested in response to the increase of algae cell number which resulting in taste and odor problem. As for heavy rain adaptation measures, the installation and operation of automatic coagulant injection devices for water purification plants that take turbid surface water were proposed. As a measure to adapt to strong winds, stabilization of power supply such as installation of dual power line was proposed in preparation for power outages. It is expected that water facilities will be able to supply high-quality tap water to customers even under extreme climate conditions without interruption through risk assessment for climate crisis factors and active implementation of adaptation measures.

A Sustainability Assessment of the Rainwater Harvesting System for Drinking Water Supply: A Case Study of Cukhe Village, Hanoi, Vietnam

  • Nguyen, Duc Canh;Dao, Anh Dung;Kim, Tschung-Il;Han, Mooyoung
    • Environmental Engineering Research
    • /
    • 제18권2호
    • /
    • pp.109-114
    • /
    • 2013
  • In Cukhe, a village located in the outskirts of Hanoi, Vietnam, people suffer from a shortage of high-quality water due to an arsenic contaminated supply water resource. We installed catchments, filters and settled tanks in the existing rainwater harvesting facility to improve water quality, and ten portable rainwater tanks to provide good-quality drinking water to the poor households and kindergartens in the dry season. The triple bottom line considerations, as well as the environmental, economic, and social impacts of the rainwater harvesting (RWH) systems are examined. RWH is a sustainable method to obtain good-quality drinking water at low cost and with little energy expenditure. Education of the system also encourages that continuation of the system and expansion can lead into economic prosperity, as the safe drinking water can be sold to the community. Hence, RWH is a unique proposal as sustainable drinking supply water for improving the lives and health of residents in Cukhe and other sites where water supply sources are contaminated.

송산그린시티(동측)내 선진 상수관로파손감시시스템 구축기술 (The deployment Advanced Technology of Water supply line breakage detection system in Songsan Green City)

  • 곽준근;박지영;윤상조
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국정보통신학회 2022년도 춘계학술대회
    • /
    • pp.291-295
    • /
    • 2022
  • 본 논문은 시민들의 Life Style 변화에 대응하고 송산그린시티의 미래상을 달성하기 위해 기술과 주거, 산업, 관광레저 등 기능이 상호 효율적으로 융합된 환경친화적 첨단도시를 건설하기 위하여 스마트도시에 적용한 u-상수도 관로파손감지시스템 구축기술에 대하여 기술하기로 한다. 관로파손감지시스템은 송산그린시티 동측지구내 상수도관 상부에 설치되는 스마트예방시트, 관로파손감지기, 관파손감지 소프트웨어, 서버 등으로 구성되며 중앙제어부(관파손감지소프트웨어, 서버)는 화성시 맑은물사업소내에 설치되어 SKT의 WCDMA방식의 무선통신망을 통하여 현장에서 화성시로 데이터를 전송하고 있다. 본 시스템은 굴착공사중 시설물 파손을 예방하고 관로 손상여부를 실시간으로 감지하여 이벤트 발생위치를 관리자에게 알려주여 누수손실을 예방하여 시설물의 수명연장을 도모한다.

  • PDF