• Title/Summary/Keyword: Water spray system

Search Result 271, Processing Time 0.042 seconds

A Study on Heat Transfer of n Storage Type Direct Contact Heat Exchanger for Solar Energy Utilization (태양열 이용 축열식 직접접촉 열교환기의 열전달에 관한 연구)

  • Kang, Yong-Heack;Jeon, Myung-Seok;Yoon, Hwan-Ki;Chun, Won-Gee
    • Solar Energy
    • /
    • v.15 no.3
    • /
    • pp.3-14
    • /
    • 1995
  • The Direct Contact heat Exchanger(DCHX) has been widely studied in the chemical industry for many years due to its inherent simplicity as a counter-current divice for heat and mass transfer. In many solar systems, the DCHX unit can be combined with the thermal storage unit, or alternatively, it can be used separately from the storage unit, much like an external(to storage) closed heat exchanger system. In the present work, the spray column type of direct contact heat exchangers are studied extensively to harness the solar energy for hot water and spaced heating. Some of the major considerations that are involved in the design of heat exchangers in this study are that : working fluid is a hydrocaabon(such as Texaterm) or water which is either lighter or heavier than storage medium. The experimental data have revealed some interesting characteristics concerning the application of DCHXs for solar energy utilization. These experiments are carried out in the line of solar heating system, major results are as follows : 1) the flow and aspect of working fluid drop for maxium heat transfer 2) efficiency and volumetric heat transfer coefficient of D.C.H.X with a heavier working fluid are higher than those of D.C.H.X with a lighter working fluid.

  • PDF

Analysis and Improvement Plan of Cultivation and Postharvest Management Status of Cut Chrysanthemum Farms in Korea (국내 절화국화 재배농가의 재배와 수확 후 관리현황 분석 및 개선 방안)

  • Roh, Yong Seung;Yoo, Yong Kweon
    • FLOWER RESEARCH JOURNAL
    • /
    • v.26 no.4
    • /
    • pp.187-194
    • /
    • 2018
  • This study was conducted to investigate the facilities, cultivation, postharvest management, and distribution status of 27 cut chrysanthemum farms in Korea. The 60% of farms have cultivated the cut chrysanthemum using soil fertigation system in the PE plastic house. In Jeonnam and Busan provinces, Standard type of chrysanthemum was cultivated mainly than spray type of chrysanthemumJeoas. Most farms have been producing the rooted cuttings by plug system using cuttings self-propagated or purchased from the company, but farms in Jeonnam have been planting cuttings directly on cultivation bed. And the 66.6% of cut chrysanthemum farms have been pretreating with dipping in hot water or tap water after harvesting. Precooling was not performed on 70.4% of the farms, and precooling farms have been mainly conducted at temperature of $2-4^{\circ}C$. After harvesting, 70.4% of the farms stored the cut flowers at $2-4^{\circ}C$ for more than 48 hours to control the distribution volume. Cut chrysanthemum was graded mainly by individuals before distribution, and some export farmers have been conducting the cooperative grading. In distribution, all farms have distributed the cut flowers to the domestic markets, and 44.4% of these farms have been also exporting. The 63.0% of farms distributed to domestic market have been trading with flower auction sites.

An Air Cleaning Efficiencies of Wet Air Cleaner in the Windowless Swine Fattening Stall in Summer (무창 비육돈사에서 습식공기정화기의 여름철 공기정화효율 분석)

  • Oh, I.H.;Lee, J.H.;Lee, K.H.;Lee, J.H.;Lee, D.S.;Eo, S.M.;Lee, M.L.
    • Journal of Animal Environmental Science
    • /
    • v.12 no.3
    • /
    • pp.133-140
    • /
    • 2006
  • The climate of stall significantly influences on animal production ability. High concentration of ammonia gas, $CO_2$ and lots of dust are found in modern densely raising stall system, as results, they provide a negative influence on animal and farmer health, and production ability. Therefore, it is necessary to keep clean the inside air of stall to increase the productivity. An air cleaner of wet type, consisting of a fan, a motor, rotating discs, a dust collector, a water bowl, an ozone generator etc, has been developed to clean the stall air. The work principle is that the inside air is sucked through the fan, and the rotating discs make water into fineness spray and blow into the stall. The rest water flows down to the dust collector. In the present study, we measured the dust, ammonia gas, odor, temperature and humidity in a swine stall that were installed two wet air cleaners with 700 fattening swine with On-mode and Off-mode of wet air cleaners. The dust measure was divided into 3 categories, TSP, $PM_{10}$, and $PM_{2.5}$. In summer, the TSP in on-mode were maximum $0.259mg/m^3$ and minimum $0.128mg/m^3$, and the average was $0.195mg/m^3$. These are comparable to the data from Off-mode stall that maximum $0.308mg/m^3$, minimum $0.139mg/m^3$, and average $0.277mg/m^3$. However, $PM_{10}$ and $PM_{2.5}$ showed any significant differences between the tests. The concentrations of ammonia gas in Off-mode stall were maximum 13.8 ppm and minimum 5.9 ppm, and the average was 8.47 ppm. However in On-mode stall the ammonia gas concentrations were maximum 10.5 ppm and minimum 5.5 ppm, and the average was 7.63 ppm. The concentration of ammonia gas in On-mode was 10% in average lower than off-mode stall. Odor was measured by olfactometer. In the Off-mode stall, the odor unit were maximum 420 $Ou/m^3$ and minimum $300\;OU/m^3$, and the average was $367\;OU/m^3$, but in the On-mode stall the odor unit were maximum $330\;OU/m^3$ and minimum $210\;OU/m^3$, and the average was $253\;OU/m^3$. Odor removal efficiency was about 31% in On-mode stall.

  • PDF

Characteristics for Sludge Removal Nozzle in Steam Generator (증기 발생기 슬러지 제거용 노즐 특성 연구)

  • Lee Sam-Goo
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.8 no.3
    • /
    • pp.37-43
    • /
    • 2004
  • Water-jet trajectory visualization and velocity deficits from a high pressurized steam-generator nozzles were experimentally observed. In order to find an optimal nozzle configuration. several parameters affecting plugging and erosion onto the steam generator tube were quantitatively analyzed. For the experiments, a high-pressurized pump (pressure in use: 200 kg/$\textrm{cm}^2$, 15 HP, 11 kW, output flow Q : 301/min) was utilized. Visualization, velocity distribution, and spray growth rate with different nozzle configurations have been mainly focused using a 2-D PDPA system. The results indicated that trajectories along the centerline regardless of their configurations has its potential core region. However, the phenomena from the peripheral part need to be meticulously considered. Accordingly, it is evident that quantitative velocity deficits at the outer region are outstanding due to the aerodynamical drag and entrainment.

An Improvement of Fire Safety Code for Rack-Type Warehouse in Korea (국내 랙크식 창고의 방화관련 규정 개선에 관한 연구)

  • Kim, Woon-Hyung;Lee, Young-Jae
    • Fire Science and Engineering
    • /
    • v.28 no.6
    • /
    • pp.69-75
    • /
    • 2014
  • Recently Amore pacific rack-type warehouse fire broke out and argue an urgent improvement of fire protection design code including automatic sprinkler and detection design. Various type of commodities have their unique fire characteristics from fire spread rate and heat lease rate and fire hazard depends on storage height, rack arrangement, aisle width, fire load etc. With increasing ceiling height for more storage space prevent effective water spray of sprinkler head, also delays detection time causes failure of early suppression. To achieve fire protection code performance of this occupancy, Major code articles relating to a classification of commodity, sprinkler system installation, detection and fire fighting are reviewed and suggested based on fire case analysis, code review between country and field survey.

Qualitative Analysis of the Major Constituents in Traditional Oriental Prescription Bang-poong-tong-sung-san by Liquid Chromatography/Ultraviolet Detector/Ion-Trap Time-of-Flight Mass Spectrometry

  • Eom, Han Young;Kim, Hyung-Seung;Han, Sang Beom
    • Mass Spectrometry Letters
    • /
    • v.5 no.1
    • /
    • pp.24-29
    • /
    • 2014
  • An advanced and reliable high performance liquid chromatography (HPLC)/ultraviolet detector (UV)/ion-trap time-of-flight (IT-TOF) mass spectrometry was developed for the simultaneous quantification of 19 marker compounds in Bang-poong-tong-sung-san (BPTS), a traditional oriental prescription. Various parameters affecting HPLC separation and IT-TOF detection were investigated, and optimized conditions were identified. The separation was achieved on a Capcell PAK C18 column ($1.5mm{\times}250mm$, $5{\mu}m$ particle size) using a gradient elution of acetonitrile and water containing 0.1% formic acid at a flow rate of 0.1 mL/min. The column temperature was maintained at $40^{\circ}C$ and the injection volume was $2{\mu}L$. IT-TOF system was equipped with an electrospray ion source (ESI) operating in positive or negative ion mode. The optimized electrospray ionization parameters were as follows: ion spray voltage, +4.5 kV (positive ion mode), or -3.5 kV (negative ion mode); drying gas ($N_2$), 1.5 L/min; heat block temperature, $200^{\circ}C$. Automatic $MS^n$ (n = 1~3) analyses were carried out to obtain structural information of analytes. Elemental compositions and their mass errors were calculated based on their accurate masses obtained from a formula predictor software. The marker compounds in BPTS were identified by comparisons between $MS^n$ spectra from standards and those from extracts. Moreover, the libraries of $MS^2$ and $MS^3$ spectra and accurate masses of parent and fragment ions for marker compounds were constructed. The developed method was successfully applied to the BPTS extracts and identified 17 out of 19 marker compounds in the BPTS extracts.

Establishment of Seed Treatment for Healthy Production of Peanut Sprout (청정 땅콩나물 생산을 위한 종자처리기술 확립)

  • Park, Eun-Ji;Lee, Gyu-Bin;Heo, You;Son, Beung-Gu;Choi, Young-Whan;Lee, Yong-Jae;Park, Young-Hoon;Suh, Jeong-Min;Kang, Jum-Soon
    • Journal of Environmental Science International
    • /
    • v.24 no.6
    • /
    • pp.755-762
    • /
    • 2015
  • The present study was conducted to develop seed treatment for the production of healthy and clean peanut sprout. Dry heat treatment of peanut seeds reduced the incidence of the rot. The seed treatment condition at $52^{\circ}C$ for 10 h. was the most efficient without inhibiting seed viability significantly. Seeds were dark cultured at $27^{\circ}C$ for up to 9 days. The treatment of Indole-B and gibberellic acid influenced germination, T50, fresh, dry weight, hypocotyl length, hypocotyl length diameter, root length, number of lateral root and epicotyl of peanut sprout. There were no differences in the germinability of peanut seeds between gibberellic acid treatment methods but higher fresh weight was observed in the GA3 solution spray after 2 hour water soaking. The general growth and lateral root development of peanut sprouts were suppressed by Indole-B which is used for inhibiting root formation and promoting hypocotyls. The treatment of gibberellic acid promoted hypocotyl elongation, but it did not influence on the growth of hypocotyls and root system.

A Study on the Improvement of the Disaster Prevention and Control System for Underpasses by Analytic Hierarchy Process (계층분석법을 통한 지하차도 재해 예방 및 제어 시스템 개선 연구)

  • Kim, Phil Do;Kim, Kyoung Soo;Moon, Yoo Mi
    • Journal of the Society of Disaster Information
    • /
    • v.16 no.4
    • /
    • pp.734-746
    • /
    • 2020
  • Purpose: Increase in the size and number of underpasses rises occurrence of disasters such as fire and flooding inundation in underpasses. In the occurrence of disasters, the underpasses are more vulnerable to expose of crucial disasters than the general roads due to they are built underground. Therefore, The purpose of this paper is to derive system improvement items to prevent and control disasters in underpasses. Method: A hierarchical model of disaster impact factors and alternatives was developed based on prior researches and expert advices on disaster analyses and impact factors in the underpasses. The developed model was employed for surveys of pairwise comparison, and rankings of improvement were determined by applying the AHP method. Result: With a consistency of the surveys, results of relative weights of evaluation criteria(traffic accidents, fire, flooding inundation) and alternatives(law, system/planning, maintenance/human factor/environment) shows that improvement of laws and system related to the fire disaster is a top priority to prevent and control disaster of the underpasses. Conclusion: From experts' point of view, strengthening laws and systems related to disater prevention facilities such as water spray facilities, external(ground) exit in relation to fire in underpasses showed that it is an alternative to prevent disasters and minimize damage to underpasses.

Development of Accelerator Control System for Wet Shotcrete Spraying Equipment (습식 숏크리트 뿜칠 장비의 급결제 유량 제어 시스템 개발)

  • Tae-Ho, Kang;Soo-Ho, Chang;Soon-Wook, Choi;Jin-Tae, Kim;Bong-Gyu, Kim;Chulho, Lee
    • Tunnel and Underground Space
    • /
    • v.32 no.6
    • /
    • pp.353-362
    • /
    • 2022
  • The wet shotcrete refers to a method in which all materials are mixed and then supplied to the spraying device, compressed air is added to the nozzle, and the spraying speed is improved to spray on the target surface. In order to reproduce the amount of shotcrete used in the wet method in the field and the situation at the laboratory scale, it is essential to control the discharge amount of the equipment. In this study, in order to increase the reproducibility of field conditions at the laboratory scale, a flow control system for shotcrete mortar spraying equipment was developed and applied to the equipment. To verify the developed equipment, a discharge control test using water and mortar was performed. In the developed control system, the discharge was smoothly controlled according to the user input value for the mono pump, but the discharge was not properly controlled according to the input value for the screw pump because of a reducer. When a speed reducer is attached, it is necessary to adjust the operation rate of the screw pump close to the target flow rate by increasing the operation rate of the screw pump while lowering the operation rate of the mono pump.

Development of Fog Cooling Control System and Cooling Effect in Greenhouse (온실 포그 냉방 제어시스템 개발 및 냉방효과)

  • Park, Seok Ho;Moon, Jong Pil;Kim, Jin Koo;Kim, Seoung Hee
    • Journal of Bio-Environment Control
    • /
    • v.29 no.3
    • /
    • pp.265-276
    • /
    • 2020
  • This study was conducted to provide a basis for raising farm income by increasing the yield and extending the cultivation period by creating an environment where crops can be cultivated normally during high temperatures in summer. The maximum cooling load of the multi-span greenhouse with a floor area of 504 ㎡ was found to be 462,609 W, and keeping the greenhouse under 32℃ without shading the greenhouse at a high temperature, it was necessary to fog spray 471.6 L of water per hour. The automatic fog cooling control device was developed to effectively control the fog device, the flow fan, and the light blocking device constituting the fog cooling system. The fog cooling system showed that the temperature of the greenhouse could be lowered by 6℃ than the outside temperature. The relative humidity of the fog-cooled greenhouse was 40-80% during the day, about 20% higher than that of the control greenhouse, and this increase in relative humidity contributed to the growth of cucumbers. The relative humidity of the fog cooling greenhouse during the day was 40-80%, which was about 20% higher than that of the control greenhouse, and this increase in relative humidity contributed to the growth of cucumbers. The yield of cucumbers in the fog-cooled greenhouse was 1.8 times higher in the single-span greenhouse and two times higher in the multi-span greenhouse compared to the control greenhouse.