• 제목/요약/키워드: Water quality parameters

검색결과 1,072건 처리시간 0.028초

반순환여과양식시스템에서 오존 유래 잔류산화물이 넙치(Paralichthys olivaceus) 사육수의 수질과 미생물에 미치는 영향 (Ozone-produced Oxidants Improve Water Quality Parameters and Microbial Colony Counts in the Semi-Recirculating Aquaculture System for Olive Flounder Paralichthys olivaceus)

  • 정상명;박우근;박성덕;박정환;김재원;김병기
    • 한국수산과학회지
    • /
    • 제54권5호
    • /
    • pp.751-760
    • /
    • 2021
  • This study investigated the changes in water quality parameters and microbial colonies when ozone was applied to a semi-recirculating aquaculture system (semi-RAS) for the olive flounder Paralichthys olivaceus (500 g in average weight). Concentrations of ozone-produced oxidants (OPO) in rearing tanks were maintained at 0, 0.014, 0.025 mg/L as Cl2 for 26 days. Except total ammonia nitrogen, nitrite nitrogen, nitrate nitrogen, phosphate phosphorus, chemical oxygen demand, and total suspended solids decreased significantly with increasing OPO concentration in daily and weekly monitoring (P<0.05). Colony forming unit (CFU) counts of heterotrophic marine bacteria decreased in an OPO concentration-dependent manner. Overall reduction rates of microbial colonies in the treatments were 80% higher than those of the control (P<0.05). During the experiment, the OPO concentration-driven ozonation was reliably practiced without any adverse effects on the animals cultured in semi-RAS. Considering the biohazard, operating cost, and stability of ozonation, an OPO concentration of 0.014 mg/L would be sufficient to control water quality parameters and microbial colonies in a semi-RAS.

한강수질 평가를 위한 COD (화학적 산소 요구량) 모델 평가 (Chemical Oxygen Demand (COD) Model for the Assessment of Water Quality in the Han River, Korea)

  • Kim, Jae Hyoun;Jo, Jinnam
    • 한국환경보건학회지
    • /
    • 제42권4호
    • /
    • pp.280-292
    • /
    • 2016
  • Objectives: The objective of this study was to build COD regression models for the Han River and evaluate water quality. Methods: Water quality data sets for the dry season (as of January) during a four-year period (2012-2015) were collected from the database of the Han River automatic water quality monitoring stations. Statistical techniques, including combined genetic algorithm-multiple linear regression (GA-MLR) were used to build five-descriptor COD models. Multivariate statistical techniques such as principal component analysis (PCA) and cluster analysis (CA) are useful tools for extracting meaningful information. Results: The $r^2$ of the best COD models provided significant high values (> 0.8) between 2012 and 2015. Total organic carbon (TOC) was a surrogate indicator for COD (as COD/TOC) with high reliability ($r^2=0.63$ in 2012, $r^2=0.75$ for 2013, $r^2=0.79$ for 2014 and $r^2=0.85$ for 2015). The ratios of COD/TOC were calculated as 2.08 in 2012, 1.79 in 2013, 1.52 and 1.45 in 2015, indicating that biodegradability in the water body of the Han River was being sustained, thereby further improving water quality. The BOD/COD ratio supported these findings. The cluster analysis revealed higher annual levels of microorganisms and phosphorous at stations along the Hangang-Seoul and Hantangang areas. Nevertheless, the overall water quality over the last four years showed an observable trend toward continuous improvement. These findings also suggest that non-point pollution control strategies should consider the influence of upstreams and downstreams to protect water quality in the Han River. Conclusion: This data analysis procedure provided an efficient and comprehensive tool to interpret complex water quality data matrices. Results from a trend analysis provided much important information about sources and parameters for Han River water quality management.

Rainfall Harvesting as an Alternative Water Supply in Water Stressed Communities in Aguata-Awka Area of Southeastern Nigeria

  • Okpoko, Ephraim;Egboka, Boniface;Anike, Luke;Okoro, Elizabeth
    • Environmental Engineering Research
    • /
    • 제18권2호
    • /
    • pp.95-101
    • /
    • 2013
  • Alternative sources of water are sought in some water stressed communities in the study area. The study focuses on the Aguata-Awka area of southeastern Nigeria. Aquifers occur at great depths, and surface waters may be far from homesteads. The scarcity of water has necessitated the people to adopt various local technologies for harvesting rainfall. The local technology includes collecting rainwater from roofs and channeling the water into large underground tanks, shallow wells and surface reservoirs. Large concrete tanks of $6m{\times}6m{\times}4m$ dimensions are often built underground and can store $144m^3$ of water. Surface reservoirs built on 4 m concrete pillar supports having dimensions of $10m{\times}10m{\times}4m$ and have a storage capacity of $400m^3$. Water samples were collected at 3 different locations of Agulu, Ekwulobia, and Awka and were analyzed for their physical, chemical, and bacteriological parameters. Results indicate a range of values for pH, 5.9 to 7.1; turbidity, 0.9 to 2.7; total dissolved solids, 80 to 170 mg/L; total hardness, 4.5 to 6.4 mg/L; magnesium, 1.2 to 1.4 mg/L; bicarbonate, 19.4 to 83.6 mg/L; and sulfate, 3.6 to 6.4 mg/L. Bacteriological analysis results were negative for fecal and total coliform counts. All parameters, with the exception of pH where aluminum and galvanized iron roofs are used for collection, fall within the recommended guidelines for drinking water quality of the World Health Organization, and the Standard Organization of Nigeria, new Nigerian standards for drinking water quality. Magnesium is above the maximum permitted level for consumer acceptability of the Nigerian standards for drinking water quality. The water can be classified as fresh moderately hard and soft. The water can be described as a calcium and bicarbonate type.

화성호 유역의 수질관리를 위한 유역모델링 연구 (Watershed Modeling Research for Receiving Water Quality Management in Hwaseong Reservoir Watershed)

  • 장재호;강형식;정광욱
    • 한국물환경학회지
    • /
    • 제28권6호
    • /
    • pp.819-832
    • /
    • 2012
  • HSPF model based on BASINS was applied for the Hwaseong Reservoir watershed (HRW) to evaluate the feasibility of water quality management. The watershed was divided into 45 sub-basins considering various watershed environment. Streamflow was calibrated based on the measured meteorological data, discharge data of treatment plants and observed streamflow data for 2010 year. Then the model was calibrated against the field measurements of water qualities, including BOD, T-N and T-P. In most cases, there were reasonable agreements between observed and predicted data. The validated model was used to analyze the characterization of pollutant load from study area. As a result, Non-point source pollutant loads during the rainy season was about 66~78% of total loads. In rainy-season, water quality parameters depended on precipitation and pollutant loads patterns, but their concentration were not necessarily high during the rainy season, and showed a decreasing trend with increasing water flow. As another result of evaluation for load duration curves, in order to improve water qualities to the satisfactory level, the watershed managements considering both time-variant and pollution sources must be required in the HRW. Overall, it was found that the model could be used conveniently to assess watershed characteristics and pollutant loads in watershed scale.

천수만의 수질환경특성과 장기변동 (Long-term Changes and Variational Characteristics of Water Quality in the Cheonsu Bay of Yellow Sea, Korea)

  • 박승윤;박경수;김형철;김평중;김전풍;박중현;김숙양
    • 한국환경과학회지
    • /
    • 제15권5호
    • /
    • pp.447-459
    • /
    • 2006
  • Long-term trends and distribution patterns of water quality were investigated in the Cheonsu Bay of Korea from 1983 to 2004. Water samples were collected at 4 stations and physicochemical parameters were analyzed including water temperature, salinity, suspended solids (SS), chemical oxygen demand (COD), dissolved oxygen (DO) and nutrients. Spatial distribution patterns were not clear between stations but the seasonal variations were distinctive except COD, SS and nitrate. Twenty two year long-term trend analysis by PCA revealed the significant changes in water quality in the study area. Water quality during 1980's and early 1990's showed high SS, low nutrients and low COD which increased during the mid and late 1990's and early 2000's. Overall water duality in the Cheonsu Bay indicated the increase in nutrients and COD concentration.

서부경남지역 음용 지하수 관리 실태 및 지역적 특성에 관한 비교 고찰 (Study on Water Quality Management of Drinking Groundwater and Its Regional Characteristics in the West Gyeong-Nam)

  • 박현건;박지연
    • 한국물환경학회지
    • /
    • 제31권2호
    • /
    • pp.103-109
    • /
    • 2015
  • The characteristics of drinking groundwater at west Gyeong-nam were analyzed by investigating 3,698 cases which were carried out from January 2008 to september 2013. 24.5% of the observed data exceeded the drinking water quality standards. Among the drinking water quality standards, 40 parameters were found to exceed. and most problematic were total coliform and HPC(Heterotrophic Plate Count). The unfit ratio of each region for drinking water were 23.1% at Geoje, 18.7% at Geochang, 28.5% at Goseong, 24.1% at Namhae, 32.8% at Sacheon, 20.5% at Sancheong, 36.9% at Uiryeong, 29.2% at Jinju, 40.9% at Tongyeong, 24.7% at Hadong, 20.6.% at Hamyang, 20.1% at Hapcheon. The result of correlation showed that rainfall and unfit ratio of HPC may be associated with the hydrologic durability and season. The coefficient of correlation between them was 0.304. During the summer, the coefficient of correlation was 0.699. But the significant correlation between total coliform and rainfall was not found.

낙동강수계 지류 수질자료를 통한 수질개선 우선순위 선정 (Priority Selection of Water Quality Improvement Through Water Quality Data of Tributaries of Nakdong River)

  • 심규현;신상민;김성민;김용석;김경훈
    • 한국물환경학회지
    • /
    • 제36권5호
    • /
    • pp.364-372
    • /
    • 2020
  • The "Master Plan for the Revitalization of Water in the Nakdong River" is designed for the fundamental improvement of water quality in the Nakdong River. The water quality and flow of the Nakdong River system tributaries was monitored in this study. Among the living environmental standard parameters of 195 rivers, BOD (Biochemical oxygen demand), T-P (Total phosphorus) and TOC (Total organic carbon) were assessed to analyze the water quality from 2012 to 2019. We examined the role of TOC. It was found that 12 rivers exceeded the water quality of the second grade (3.0 mg/L BOD standard, 0.1 mg/L T-P standard, 4.0 mg/L TOC standard) based on BOD and T-P concentrations: the Gumi stream, Gisegok stream, Yongha stream, Yongho stream, Changnyeong stream, Gajwa stream, Gwangok stream, Yeongsan stream, Toerae stream, Hwapo stream, Sangnam stream and Hogye stream. These rivers require strategies to improve the quality of the Nakdong River. Based on the ongoing project, it is possible to supplement the "Master Plan for the Revitalization of Water in the Nakdong River" and manage it after verifying it as a component of people's life and therefore used to establish water quality control measures.

환경영향평가에 사용되는 컴퓨터 모델에 관한 연구 I : 수질 모델 (A Study of Computer Models Used in Environmental Impact Assessment I : Water Quality Models)

  • 박석순;나은혜
    • 환경영향평가
    • /
    • 제9권1호
    • /
    • pp.13-24
    • /
    • 2000
  • This paper presents a study of water quality model applications in environmental impact statements which were submitted during recent years in Korea. Most of the applications have reported that the development projects would have significant impacts on the water quality, especially, of streams and rivers. The water quality models, however, were hardly used as an impact prediction tool. Even in the cases where models were used, calibration and verification studies were not performed and thus the predicted results would not be reliable. These poor model applications in environmental impact assessment can be attributable to the fact that there were no available model application guidelines as well as no requirements by the review agency. In addition, the expected waste loads were improperly estimated in most cases, especially in non-point sources, and the predicted parameters were not good enough to understand water quality problems expected from the proposed plans. The effects of mitigation measures were not analyzed in most cases. Again, these can be attributed to no formal guidelines available for impact predictions until now. A brief guideline is described in this paper, including model selection, calibration and verification, impact prediction, and analysis of effects of mitigation measures. The results of this study indicate that the model application should be required to overcome the current improper predictions of environmental impacts and the guidelines should be developed in detail and provided.

  • PDF

사무실 사용용수의 수량/수질 동시 측정이 가능한 일체형 스마트 워터 미터의 현장 적용성 평가 (Evaluation of Field Applicability for All-In-One Smart Water Meter to Measure both Water Quantity and Quality in Office Building Water Usage)

  • 이새로미;오현제;주진철;안창혁;박재로
    • 상하수도학회지
    • /
    • 제30권6호
    • /
    • pp.653-662
    • /
    • 2016
  • Recently, advanced metering infrastructure (AMI) has been recognized as a core technology of smart water grid, and the relevant market is growing constantly. In this study, we developed all-in-one smart water meter of the AMI system, which was installed on the test-bed to verify both effectiveness and field applicability in office building water usage. Developed 15 mm-diameter smart water meter is a magneto-resistive digital meter, and measures flow rate and water quality parameters (temperature, conductivity) simultaneously. As a result of the water usage analysis by installing six smart water meters on various purposes in office building water usage, the water usage in shower room showed the highest values as the 1,870 L/day and 26.6 liter per capita day (LPCD). But, the water usage in laboratory was irregular, depending on the many variables. From the analysis of the water usage based on day of the week, the water usage on Monday showed the highest value, and tended to decrease toward the weekend. According to the PCA results and multivariate statistical approaches, the shower room (Group 3) and 2 floor man's restroom sink (Group 1-3) have been classified as a separate group, and the others did not show a significant difference in both water use and water quality aspects. From the analysis of water usage measured in this study, the leak or water quality accident did not occur. Consequently, all-in-one smart water meter developed in this study can measure flow rate and water quality parameters (temperature, conductivity) simultaneously with effective field applicability in office building water usage.

Effect of Flow Direction on Two-Phase Flow Distribution of Refrigerants at a T-Junction

  • Tae Sang-Jin;Cho Keum-Nam
    • Journal of Mechanical Science and Technology
    • /
    • 제20권5호
    • /
    • pp.717-727
    • /
    • 2006
  • The present study experimentally investigated the effect of flow direction and other flow parameters on two-phase flow distribution of refrigerants at a T-junction, and also suggested a prediction model for refrigerant in a T-junction by modifying previous model for air-water flow. R-22, R-134a, and R-410A were used as test refrigerants. As geometric parameters, the direction of the inlet or branch tube and the tube diameter ratio of branch to inlet tube were chosen. The measured data were compared with the values predicted by the models developed for air-water or steam-water mixture in the literature. We propose a modified model for application to the reduced T-junction and vertical tube orientation. Among the geometric parameters, the branch tube direction showed the biggest sensitivity to the mass flow rate ratio for the gas phase, while the inlet quality showed the biggest sensitivity to the mass flow rate ratio among the inlet flow parameters.