• Title/Summary/Keyword: Water pressure management

Search Result 279, Processing Time 0.035 seconds

Regeneration of solid phase filter by chemical cleaning

  • Byung-Dae Lee
    • Journal of the Korean Applied Science and Technology
    • /
    • v.41 no.1
    • /
    • pp.19-26
    • /
    • 2024
  • Recently, separation membranes have been applied to fields such as water supply, sewage treatment, gray water reuse, and air pollution control. Chemical cleaning technology is attracting attention among the methods of reusing these expensive separation membranes. It was found that the separation membrane could be regenerated using chemical cleaning. Specifically, it was found that the use time of the separation membranes regenerated by chemical cleaning was sustainable for more than 1,700 hours. Additionally, it was found that the flux recovery ratio after chemical cleaning was maintained at least 60%. In addition, the flux recovery ratio of HYDREX 4710, an organic membrane cleaner, and 4703, an inorganic membrane cleaner, was 76% and 62%, respectively, showing the highest flux recovery ratio among the chemicals used. Considering that the target raw water of this study is biological secondary treatment water, it was suggested that chemical cleaning could be actively used to regenerate separation membranes in future water treatment.

The effect of external influence and operational management level on urban water system from water-energy nexus perspective (물-에너지 넥서스 관점에서 외부영향과 운영관리 수준이 도시물순환시스템에 미치는 영향)

  • Choi, Seo Hyung;Shin, Bongwoo;Song, Youngseok;Kim, Dongkyun;Shin, Eunher
    • Journal of Korea Water Resources Association
    • /
    • v.56 no.9
    • /
    • pp.587-602
    • /
    • 2023
  • Due to climate change, population growth, and economic development, the demand for water in the urban water system (UWS) and the energy required for water use constantly increase. Therefore, beyond the traditional method of considering only the water sector, the Nexus approach, which considers synergies and trade-offs between the water and energy sectors, has begun to draw attention. In previous researches, the Nexus methodology was used to demonstrate that the UWS is an energy-intensive system, analyze the water-energy efficiency relationship surrogated by energy intensity, and identify climate (long-term climate change, drought, type), geographic characteristics (topography, flat ratio, location), system characteristics (total supply water amount, population density, pipeline length), and operational management level (water network pressure, leakage rate, water saving) effects on the UWS. Through this, it was possible to suggest the direction of policies and institutions to UWS managers. However, there was a limit to establishing and implementing specific action plans. This study built the energy intensity matrix of the UWS, quantified the impact of city conditions, external influences, and operational management levels on the UWS using the water-energy Nexus model, and introduced water-energy efficiency criteria. With this, UWS managers will be able to derive strategies and action plans for efficient operation management of the UWS and evaluate suitability and validity after implementation.

CONSTRUCTION MANAGEMENT OF TUNNELLING IN SEVERE GROUNDWATER CONDITION

  • Young Nam Lee;Dae Young Kim
    • International conference on construction engineering and project management
    • /
    • 2005.10a
    • /
    • pp.655-661
    • /
    • 2005
  • For a hydro power plant project, the headrace tunnel having a finished diameter of 3.3m was constructed in volcanic rocks with well-developed vertical joint and high groundwater table. The intake facility was located 20.3 km upstream of the powerhouse and headrace tunnel of 20 km in length and penstock of 440 m in height connected the intake and the powerhouse. The typical caldera lake, Lake Toba set the geology at the site; the caving of the ground caused tension cracks in the vertical direction to be developed and initial stresses at the ground to be released. High groundwater table(the maximum head of 20 bar) in the area of well-connected vertical joints delayed the progress of tunnel excavation severely due to the excessive inflow of groundwater. The excavation of tunnel was made using open-shield type TBM and mucking cars on the rail. High volume of water inflow raised the water level inside tunnel to 70 cm, 17% of tunnel diameter (3.9 m) and hindered the mucking of spoil under water. To improve the productivity, several adjustments such as modification of TBM and mucking cars and increase in the number of submersible pumps were made for the excavation of severe water inflow zone. Since the ground condition encountered during excavation turned out to be much worse, it was decided to adopt PC segment lining instead of RC lining. Besides, depending on the conditions of the water inflow, rock mass condition and internal water pressure, one of the invert PC segment lining with in-situ RC lining, RC lining and steel lining was applied to meet the site specific condition. With the adoption of PC segment lining, modification of TBM and other improvement, the excavation of the tunnel under severe groundwater condition was successfully completed.

  • PDF

A study on the explosion properties and Autoignition Temperature of a food additive Dusts (식품분진의 폭발 특성과 발화온도에 관한 연구)

  • 안형환
    • Proceedings of the Safety Management and Science Conference
    • /
    • 2001.05a
    • /
    • pp.301-310
    • /
    • 2001
  • A study for the dangerous properties measurment of dust explosion was attended by the various dust concentration on Anthraquinone, Sodiumbenzoic acid, Corn starch, soy sauce powder, and cheese powder. As the result, maximum explosion pressure, the maximum rate of pressure rise, autoigntion temperature, and the water content of dust on lower limit explosion concentration was obtained as follows 1. The lower limit explosion concentration on soy sauce powder with the humidity of 65 to 90% increased by increasing the con tent of moisture, and the effect of dry air and moisture air decreased better in make of dry air. 2. The effect of a various dust concentration on autoigntion temperatures is investigated, If the vessel of dust explosion is small size and the easiness of autoignition was controled by air within the vessel, because it was better decreased air with increasing of dust concentration 3. The maximum explosion pressures of Anthraguinone, sodiumbenzoic acid, com starch, soy sauce powder, and cheese powder were 1.0g/$\ell$, 1.0g/$\ell$, 1.5g/$\ell$, 1.5g/$\ell$, and 1.5g/$\ell$, respectively, and the maximum rate of pressure rise were 0.5g/$\ell$, 0.5g/$\ell$, 1.0g/$\ell$, 1.0g/$\ell$, and 1.0g/$\ell$, respectively.

  • PDF

Blood Pressure Lowering Effect of Korean turbid rice wine (Takju) Lees Extracts in Spontaneously Hypertensive Rat (SHR) (막걸리박 열수추출물 첨가 식이가 선천성 고혈압쥐(SHR)의 혈압 저하에 미치는 영향)

  • Lee, Hyun-Sook;Hong, Kyoung-Hee;Kim, Jae-Young;Kim, Dong-Hee;Yoon, Cheol-Ho;Kim, Soon-Mi
    • Journal of the Korean Society of Food Culture
    • /
    • v.24 no.3
    • /
    • pp.338-343
    • /
    • 2009
  • This study was conducted to investigate the effects of Takju lees hot water extracts on the blood pressure in spontaneously hypertension rats (SHR). Twenty eight male SHR were grouped by their blood pressure and fed a control diet or experimental diets containing 1% (G1), 2% (G2), or 4% (G4) Takju lees extracts for 4 weeks. Food intake was not significantly different among the groups. However, body weight gain was significantly lower in groups fed the Takju lees extract than the control group. The systolic blood pressure was significantly lower in the Takju lees extract containing groups (especially in G4 group) than the control groups. In addition, mean blood pressure {(systolic+dyastolic)/2} decreased with an increase in the amount of Takju lees extract in the diet and feeding period. Takju lees extract decreased angiotensin I converting enzyme (ACE) activity in a dose-dependent manner. These results suggest that the Takju lees extract exert an antihypertensive effect by decreasing ACE activity.

Development of Rehabilitation and Management Techniques for Old Water Distribution Systems (기존 상수도 노후관망의 개량 및 관리 기법의 개발)

  • 김중훈;김종우
    • Water for future
    • /
    • v.29 no.3
    • /
    • pp.197-205
    • /
    • 1996
  • Flow carrying capacity of water distribution systems is getting reduced by deterioration of pipes in the systems. The objective of this study is to develop a managerial decision-making model for the rehabilitation of water distribution systems with a minimum cost. The decisions made by the model also satisfy the requirements for the discharge and pressure at demanding nodes in the system. The replacement cost, pipe break repair cost, and pumping cost are considered in the economic evaluation of the decision along with the break ratio and interest ratio to determine the optimal replacement time for each pipe. Then, the hydraulic integrity of the water distribution system is checked for the decision by a pipe network simulator, KYPIPE, if the discharge and pressure requirements, the decision made for the optimal replacement time is revised until the requirements are satisfied. The model is applied to an existing water distribution system, the Metropolita Water Supply Project (1st Phase). The result shows that the decisions for the replacement time determined by the economix analysis are accepted as optimal and the hydraulic integrity of the system is in good condition.

  • PDF

Efficient Management of the pH of the Wet Scrubber Washing Water for Risk Mitigation (리스크 완화를 위한 Wet Scrubber 세정수 pH의 효율적 관리)

  • Joo, Dong-Yeon;Seoe, Jae Min;Kim, Myung-Chul;Baek, Jong-Bae
    • Journal of the Korean Society of Safety
    • /
    • v.35 no.6
    • /
    • pp.85-92
    • /
    • 2020
  • Wet Scrubber reacts the incoming pollutant gas with cleaning water (water + absorbent) to absorb pollutants and release the clean air to the atmosphere. Wet scrubbers and packed tower scrubbers using this principle are widely used in businesses that emit acid gases. In particular, in the etching process using hydrochloric acid (HCl), alkaline washing water (NaOH) having a pH of about 8 to 11 is used to absorb a large amount of acid gas. However, These salts are attached to the injection nozzle (nozzle), filling material (packing), and the demister (Demister), causing air pollution, human damage, and inoperability due to clogging and acid gas discharge. Therefore, In this study, an improvement plan was proposed to manage the washing water with pH 3~4 acidic washing water. The test method takes samples from the Wet Scrubber flue measurement laboratory twice a month for 1 year. Hydrogen chloride (HCl) concentration (ppm) was measured, and nozzle clogging and scale conditions were measured, compared, and analyzed through a differential pressure gauge and a pressure gauge. As a result of the check, it was visually confirmed that the scale was reduced to 50% or less in the spray nozzle, filler, and demister. In addition, the emission limit of hydrogen chloride in accordance with the Enforcement Regulation of the Air Quality Conservation Act [Annex 8] met 3 ppm or less. Therefore, even if the washing water is operated in an acidic pH range of 3 to 4, it is expected to reduce air pollution and human damage due to clogging of internal parts, and it is expected to reduce maintenance costs such as regular cleaning or replacement of parts.

Properties of Oil-in-Water Nano-emulsions Prepared from Hydrogenated Lecithin with High Pressure Homogenizer

  • Cho, Wan-Goo;Bae, Duck-Whan
    • Journal of the Korean Applied Science and Technology
    • /
    • v.28 no.1
    • /
    • pp.1-5
    • /
    • 2011
  • In this study, We investigated the properites of nano-emulsions containing hydrogenated lecithin prepared by high pressure homogenizer. The size of droplet of emulsions prepared by homogenizer at various rpm (rotation per minute) was not measured due to the unstability of emulsions, however, the size of droplet of nano-emulsions prepared by high pressure homogenizer was around 300 nm and the appearance of emulsions was bluish. The stability of emulsions with various lecithin concentration was tested against time. POV (Peroxide value) of emulsions were plotted against time. POVs of emulsions prepared with an egg lecithin and a soy lecithin were increased with time, however, POV of emulsion with Lecinol S-$10^{(R)}$ was kept constant within 60 hours and at $60^{\circ}C$. In consumer test, the nano-emulsion showed higher affinity regardless of skin type. Both of irritation scores of emulsions were similar.

The Development of a Flood Protection System for Pad Transformers Using Pneumatic Pressure in Areas Prone to Floods

  • Kim, Gi-Hyun;Lee, Jae-Yong;Bae, Suk-Myong
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.3
    • /
    • pp.27-32
    • /
    • 2010
  • The inundation of substation and ground power equipment breaks out every summer season in low-lying downtown areas and low-lying shores by torrential rain, typhoons and tsunamis. It has, in turn, caused replacement, social and economic costs for blackouts. For activity management regarding flood damage we produced a flood protection system which using the Pad transformer as a basic frame and is developed using pneumatic pressure. We tested safety concerns including insulation resistance and current leakage first for water tank flooding and, second, by an empirical test through supplying 22.9[kV]. We estimate that costs associated with flooding and power failure can be diminished by these advances toward creating a more reliable system.

Two-Phase Flow Characteristics in an Adiabatic Horizontal Tube (단열 수평관내 이상류의 유동특성)

  • Choi, B.H.
    • Journal of Power System Engineering
    • /
    • v.8 no.1
    • /
    • pp.36-40
    • /
    • 2004
  • Two-phase loop systems using the latent heat capacity of their working fluids can meet the increasing power requirements and are well suited to thermal management systems of future large applications, due to its abilities to handle large heat loads and to provide them at uniform temperatures regardless of the changes in the heat loads. Therefore some experiments on the effect of the gas and liquid superficial velocities, $j_G,\;j_L$ on flow pattern transition, void fraction and frictional pressure loss were performed on a co-current air-water flow in an adiabatic horizontal tube. The flow patterns were depended on the superficial velocity of each phase. It snowed that the increasing $j_L$, resulted in a significant increase in the frictional pressure loss for all flow patterns, at a constant $j_G$. The experimental results were also evaluated with some of existing models and correlations.

  • PDF