• 제목/요약/키워드: Water pollutant$BOD_5$

검색결과 196건 처리시간 0.033초

낙동강수계 수질오염총량관리를 위한 시범소유역 유황별 유달율 산정방법 연구 (A Study on Estimation of the Delivery Ratio by Flow Duration in a Small-Scale Test Bed for Managing TMDL in Nakdong River)

  • 손태석;박재범;신현석
    • 한국물환경학회지
    • /
    • 제25권5호
    • /
    • pp.792-802
    • /
    • 2009
  • The objective of this study is to construct the watershed management system with link of the non-point sources model and to estimate delivery ratio duration curves for various pollutants. For the total water pollution load management system, non-point source model should be performed with the study of the characteristic about non-point sources and loadings of non-point source and the allotment of pollutant in each area. In this study, daily flow rates and delivered pollutant loads of Nakdong river basin are simulated with modified TANK model and minimum variance unbiased estimator and SWAT model. Based on the simulation results, flow duration curves, load duration curves, and delivery ratio duration curves have been established. Then GIS analysis is performed to obtain several hydrological geomorphic characteristics such as watershed area, stream length, watershed slope and runoff curve number. As a result, the SWAT simulation results show good agreements in terms of discharge, BOD, TN, TP but for more exact simulation should be kept studying about variables and parameters which are needed for simulation. And as a result of the characteristic discharges, pollutants loading with the runoff and delivery ratios, non-point sources effects were higher than point sources effects in the small-scale test bed of Nakdong river basin.

강우시 신갈호 유입하천의 오염부하량 및 기여율 산정 (Estimation pollutant load and rate of contribution in inflow streams of Sin-gal reservoir during the raining season)

  • 정재훈;안태웅;최이송;오종민
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 2009년도 학술발표회 초록집
    • /
    • pp.966-970
    • /
    • 2009
  • 경기도 용인시, 오산시와 화성시 지역의 농업용수와 공업용수의 공급원으로 이용되고 있는 신갈호는 현재 유입하천으로부터 미처리된 도시하수, 공장 폐수, 축산 폐수 등의 점오염원 및 도시 지역 불투수층에 쌓여있는 오염물질인 비점오염원이 무분별하게 유입되어 수질이 매우 악화되어 용수로의 사용이 어려운 지경에 달하였으며, 자연정화능력도 감소하는 등 심각하게 오염되었다. 또한 최근에는 신갈호 유역의 개발에 따른 토지이용 변화로 신갈호 유역의 총오염부하량이 증가하고 있는 실정이다. 따라서 본 연구에서는 현재 날로 심각해지는 신갈호 유입하천의 비점오염원 조사를 통해 신갈호 및 유입하천의 기초데이터의 확충 및 현황 파악을 하고자 하였다. 본 연구에서는 강우 시 신갈호로 유입되는 3개의 유입지천인 신갈천(SG), 지곡천(JK), 공세천(KS)에서 비점오염부하량을 산정함으로써 강우 시 호소로 유입되는 총오염부하량 및 비점오부하량의 비율을 알아보고자 하였다. 강우사상에 따른 총 오염물질 부하량은 EMC 농도를 구한 후 총 유출유량을 곱하고 총 강우지속시간을 곱하여 산정하였다. 조사결과 강우기에 있어서 거의 모든 항목의 농도는 평수기보다 매우 높은 수치를 나타냈다. 특히 SS 농도는 토사의 하천유입으로 인해 다른인자에 비해 큰 변동폭을 나타내었으며, COD와 T-P는 토양입자에 흡착되어 함께 이동하기 때문에 SS와 밀접한 관계를 가졌다. 강우시의 각 유입하천별 오염부하 기여율은 SG의 경우 SS 74.1%, BOD 64.4%, COD 65.7%, T-N 63.8%, T-P 73.8%를 나타내었다. JK의 경우 SS 25.4%, BOD 31.5%, COD 30.5%, T-N 32.5%, T-P 24.2% 였고, KS의 경우 SS 0.5%, BOD 4.1%, COD 3.8%, T-N 3.7%, T-P 2.0%를 나타내었다. 강우시의 각 유입하천별 오염부하 기여율을 평수기때의 오염부하 기여율과 비교하였다. 비교결과 SS의 경우는 SG가 강우시에 74%, 평수기에 83%, BOD의 경우는 강우시 64%, 평수기 80%, T-N은 강우시 64%, 평수기에 84%, T-P의 경우는 강우시 74%, 평수기에 82%로 모든 항목에서 평수기에 신갈천이 신갈호의 오염부하에 미치는 영향이 큰 것으로 나타났는데, 이는 강우시 지곡천의 기여율이 평수기 보다 상대적으로 높아지기 때문인 것으로 판단된다.

  • PDF

오염부하량 및 유하거리가 인공습지에 의한 폐수처리 효율에 미치는 영향 (Effect of Pollutant Loading and Flow Distance to Wastewater Treatment Efficiency in the Constructed Wetland System)

  • 김형중;김선주;윤춘경
    • 한국농공학회지
    • /
    • 제39권5호
    • /
    • pp.97-108
    • /
    • 1997
  • Natural wastewater treatment systems using the constructed wetland system were evaluated for the wastewater from the industrial complex in rural areas. For the treatment of wastewater from the industrial complex in rural area, a pilot plant of the constructed wetland system was installed at Baeksuk agri-industrial complex in ChunahnCity, Chunchungnam-Do. The experiment with this pilot plants was performed for 1996 and 1997. Results of the study were summarized as follows. For the BOD and COD, when the pollutant loading of them was about 1 3.8g/$m^2$. day (the concentration was l24.0mg/${\ell}$) arid 24.4g/$m^2$.day(the concentration was 220.Omg/${\ell}$), the removal rate of them was high, 90.2% and 93.4%, respectively. For the SS, the effluent concentration was consistently lower than the water quality standard even though the influent concentration varied significantly, which showed that SS was removed by the system effectively which consist of soil and plants. For the T-N and T-P, when the influent pollutant loading of them were moderately high, 2.8g/$m^2$.day to 7.4g/$m^2$. day(concentration 25.0mg/${\ell}$ to 49.7mg/${\ell}$) for T-N and 1.0g/$m^2$.day to 2.6g /$m^2$.day(concentration 8.6mg/${\ell}$ to 14.7mg/${\ell}$) for T-P, the removal rate of them were 86.5% and 94.0%, respectively. The removal rate by the flow distance increased rapidly in the first 4m from the inlet zone, and gradually there after. The width of system was 2m. Overall, the result showed that constructed wetland system is a feasible alternative for the treatment of wastewater from industrial complex in rural areas. Compared to existing systems, this system is quite competitive because it requires low capital cost, almost no energy and maintenance, and therefore, very cost effective.

  • PDF

오염원 산정단위 수준의 소유역 세분화를 고려한 새만금유역 수문·수질모델링 적용성 검토 (Developing Surface Water Quality Modeling Framework Considering Spatial Resolution of Pollutant Load Estimation for Saemangeum Using HSPF)

  • 성충현;황세운;오찬성;조재필
    • 한국농공학회논문집
    • /
    • 제59권3호
    • /
    • pp.83-96
    • /
    • 2017
  • This study presented a surface water quality modeling framework considering the spatial resolution of pollutant load estimation to better represent stream water quality characteristics in the Saemangeum watershed which has been focused on keeping its water resources sustainable after the Saemangeum embankment construction. The watershed delineated into 804 sub-watersheds in total based on the administrative districts, which were units for pollutant load estimation and counted as 739 in the watershed, Digital Elevation Model (DEM), and agricultural structures such as drainage canal. The established model consists of 7 Mangyung (MG) sub-models, 7 Dongjin (DJ) sub-models, and 3 Reclaimed sub-models, and the sub-models were simulated in a sequence of upstream to downstream based on its connectivity. The hydrologic calibration and validation of the model were conducted from 14 flow stations for the period of 2009 and 2013 using an automatic calibration scheme. The model performance to the hydrologic stations for calibration and validation showed that the Nash-Sutcliffe coefficient (NSE) ranged from 0.66 to 0.97, PBIAS were -31.0~16.5 %, and $R^2$ were from 0.75 to 0.98, respectively in a monthly time step and therefore, the model showed its hydrological applicability to the watershed. The water quality calibration and validation were conducted based on the 29 stations with the water quality constituents of DO, BOD, TN, and TP during the same period with the flow. The water quality model were manually calibrated, and generally showed an applicability by resulting reasonable variability and seasonality, although some exceptional simulation results were identified in some upstream stations under low-flow conditions. The spatial subdivision in the model framework were compared with previous studies to assess the consideration of administrative boundaries for watershed delineation, and this study outperformed in flow, but showed a similar level of model performance in water quality. The framework presented here can be applicable in a regional scale watershed as well as in a need of fine-resolution simulation.

남천에서의 강우시 비점오염물질의 유출특성 (Runoff Characteristics of Non-point Source According to Rainfall in Nam Watershed)

  • 장성호;박진식
    • 한국환경보건학회지
    • /
    • 제31권1호
    • /
    • pp.1-6
    • /
    • 2005
  • This study was conducted to identify the runoff characteristics of non-point source according to rainfall in Nam watershed. Land-uses of the Nam watershed were surveyed paddy field 4.5%, crop field 6.8%, mountainous 78.7%, urban 2.4%, and etc. 7.7%. Mean runoff coefficients in each area were observed Ⅰ area 0.08, Ⅱ area 0.08, and Ⅲ area 0.05. In the relationship between the rainfall and peak-flow, correlation coefficients(r) were investigated Ⅰ area -0.8609, Ⅱ area 0.6035, and Ⅲ area -0.4913. In the relationship between the antecedent dry period and first flow runoff, correlation coefficients(r) were investigated Ⅰ area -0.9093, Ⅱ area -0.1039, and Ⅲ area -0.7317. The discharge of pollutant concentrations relates to the flow rate of storm-water. In the relationship between the rainfall and watershed loading, exponent values of BOD, COD, SS, and T-N were estimated to 1.2751, 1.2003, 1.3744, and 1.1262, respectively.

착유시스템별 세척수 발생량에 관한 연구 (Research on the Amount of Wastewater Produced from the Different Milking System)

  • 최동윤;강희설;곽정훈;최희철;김재환;김태일;이덕수;권두중;한정대
    • 한국축산시설환경학회지
    • /
    • 제7권2호
    • /
    • pp.77-82
    • /
    • 2001
  • This research was carried out to investigate the daily amount and characteristics of wastewater produced from bucket milkers, pipeline, tandem ad herringbone milking system for washing operations after milking included 28 dairy farms. The average amount of wastewater produced from milking system was 9.8l/head/day. The amount of wastewater varied from a low of 8.2 litters/head/day(pipeline milking system) to 13.4 litter/head/day(herringbone milking system). The moisture content, Biochemical Oxygen Demand($BOD_5$), Chemical Oxygen Demand($COD_{Mn}$), Suspended Solids(SS), Total Nitrogen(T-N) and Total Phosphorus(T-P) concentration of wastewater were 99.9%, 394mg/l, 417.3mg/l, 1,201.3mg/l, 3.78mg/l, 0.51mg/l.

  • PDF

무심천 수질 오염 실태와 그 방지책;I. 하계절의 수질 오염 분석 (Contamination of the Mushim-Cheon and its Countermeasures;I. Analysis of the Water Samples in Summer)

  • 이재구;경기성;김학남;오경석
    • 한국환경농학회지
    • /
    • 제9권1호
    • /
    • pp.23-37
    • /
    • 1990
  • 무심천의 오염실태와 그 방지책을 강구하기 위하여 1989년 8월과 9월 2회에 걸쳐 채수한 수질을 분석하여 다음과 같은 결과를 얻었다. 1. 8, 9월의 주간 무심천 수온은 미생물과 조류의 생육에 지장이 없는 것으로 보이는25.8-$30.8^{\circ}C$로써 자정능력이 있는 것으로 판단되었다. 2. 동 기간중 무심천수의 pH는 St 14를 제외하고는 6.5-8.5 범위이었다. 3. St 18(분뇨처리장 배수구와 무심천의 합류지점)에서 9월에 DO가 0.7 ppm까지 내려가는 현상이 관찰되었다. 4. St 18에서 BOD가 최고 62.1 ppm으로써 분뇨 처리장 방류수의 BOD 허용치인 40 ppm 을 크게 초과하였다. 또한 SS도 8, 9월에 각각 200과 520ppm으로써 허용치인 70 ppm을 3-7배 초과 하였다. 5. St 18에서 9월중에 $NH_3-N$이 46.2 ppm이나 되는 것은 분뇨로 크게 오염되어 있음을 말해 준다. 6. 9월중 사직동 하수의 BOD 부하량은 약 0.306ton/day이었다. 7. 무심천 본류보다 무심천으로 유입되는 지천과 가정하수구 및 분뇨처리장 방류수에서 오염도가 훨씬 높았다. 8. St 12(사직동 하수)의 2시간별로 채수한 시료에서 오염물질의 부하량이 인근 주민의 생활주기와 밀접한 관계가 있음을 알 수 있었다. 9. 1979년 무심천 수질 분석 결과와 비교해 볼 때 영운동 취수장(St 9)에서는 큰 차이가 없었으나 사직동 하수(청주대교 밑, St 12)와 제2운천교(St 15)에서는 최근 10년 동안 수질이 더욱 악화되었음을 알 수 있다.

  • PDF

강우시 도시배수구역의 유출특성 지배인자 분석 (Identifying dominant parameters of storm-sewer-overflows in seperate sewer system)

  • 정시몬;박인혁;하성룡
    • 한국습지학회지
    • /
    • 제10권2호
    • /
    • pp.105-114
    • /
    • 2008
  • 급격한 도시화에 따른 불투수 면적과 인구의 증가로 인하여 많은 양의 오염물이 배출되고 있고, 이로 인하여 지역 하천의 수질이 심각한 위협을 받고 있다. 특히 강우시 지표면의 쌓인 다량의 오염물질은 오수관으로 유입된 후 월류되어 하천으로 유입되기 때문에 이에 대한 연구와 관리시스템의 마련이 시급하다. 이에 본 연구에서는 청주시를 대상으로 도시배수구역의 유출특성을 분석하고 이에 영향을 미치는 인자를 추출 및 분석할 수 있는 통계적 분석방법을 제시 것에 목적이 있다. 선행된 연구를 참고하여 강우강도, 선행건기일수, 강우량과 5개의 수질분석항목(CODcr, BOD, SS, TN, TP)과의 관계를 통계적인 방법으로 분석하였으며, 강우시 도시유출특성을 지배하는 인자에 대한 규명을 시도하였다.

  • PDF

강우시 인공 초지의 비점오염물질 유출특성 및 상관성 (Washoff Characteristics of NPS Pollutants from Artificial Grassland)

  • 이정용;;최지연;이재운;김이형
    • 한국습지학회지
    • /
    • 제11권3호
    • /
    • pp.145-151
    • /
    • 2009
  • 현재까지 국내의 수질관리 정책은 점오염원 관리를 우선시 하고 있다. 그러나 계속되는 점오염원의 관리에도 불구하고 호소수의 수질은 악화되고 있다. 비점오염원은 강우 시 발생하는 오염원으로 토지이용에 따라 발생하는 오염물질의 종류와 양이 달라 불확실성이 큰 오염원이므로 점오염원과 함께 비점오염원의 관리가 필요한 실정이다. 다양한 토지이용 중에서 인공초지(공원 묘지) 지점이 차지하는 비율이 낮기 때문에 원단위를 산정하는데 필요한 기초 데이터에 대한 연구가 전무한 상태이다. 따라서 본 연구는 인공초지(공원 묘지) 지점으로부터 강우 시 유출수와 함께 발생하는 비점오염물질의 유출특성 및 상관성을 파악하였다. 그 결과 강우 초기에 오염물질의 농도는 비교적 높게 유출되는 현상을 나타냈으며, 강우가 지속될수록 오염물질의 농도는 감소하는 것으로 나타났다. 그러나 첨두유량이 발생하면서 유출농도는 증가하였다. 또한 통계분석을 실시한 결과 오염물질별 상관성이 거의 없는 것으로 나타났다. 이러한 결과는 향후 부하량과 원단위 산정에 필요한 기초자료로 활용될 수 있을 것으로 기대된다.

  • PDF

강우시 임하호 유입수 수질변동과 오염물질의 공간적 이동 특성 (Characteristics of Inflow Water Quality Variations and Pollutants Transport in Imha Reservoir during a Rainfall Event)

  • 이흥수;신명종;윤성완;정세웅
    • 한국물환경학회지
    • /
    • 제29권1호
    • /
    • pp.97-106
    • /
    • 2013
  • The temporal and spatial variations of water quality in a stratified reservoir are fully dependent on the characteristics of inflow loading from its watershed and the transport regimes of pollutants after entering the reservoir. Because of the meteorological and hydrological conditions in Korea, the pollutants loading to reservoirs are mostly occur during rainfall events. Therefore it is important to understand the characteristics of pollutants loading from upstream rivers and their spatial propagation through the stratified reservoir during the rainfall events. The objectives of this study were to characterize the water quality variations in upstream rivers of Imha Reservoir during a rainfall event, and the transport and spatial variations of pollutants in the reservoir through extensive field monitoring and laboratory analysis. The results showed that the event mean concentration (EMC) of SS, BOD, $COD_{Mn}$, T-N, T-P, $PO_4-P$ are 8.6 ~ 362.1, 2.5 ~ 5.1, 1.5 ~ 5.1, 1.1 ~ 1.9, 8.3 ~ 57.1, 5.6 ~ 25.7 times greater than the mean concentrations of these parameters during non-rainfall period. The turbidity and SS data showed good linear correlations, but the relationships between flow and SS showed large variations because of hysteresis effect during rising and falling periods of the flood. The ratio of POC to TOC were 12.6 ~ 14.7% during the non-rainfall periods, but increased up to 28.2 ~ 41.7% during the flood event. The turbid flood flow formed underflow and interflow after entering the reservoir, and delivered a great amount of non-point pollutants such as labile and refractory organic matters and nutrients to the metalimnion layer of reservoir, which is just above the thermocline. Spatially, the lateral variations of most water quality parameters were marginal but the vertical variations were significant.