• 제목/요약/키워드: Water pipe supply

검색결과 265건 처리시간 0.026초

가스내장 히트파이프의 냉시동특성과 성능에 관한 연구 (A Study on the Chilling Start-up Characteristics and Performance of a Gas Loaded Heat Pipe)

  • 홍성은;강환국
    • 설비공학논문집
    • /
    • 제18권11호
    • /
    • pp.915-922
    • /
    • 2006
  • Considering heat pipe design principles in fabrication and operational performances, water is one of the most recommended working fluids to make mid to low tempera lure heat pipes. But the conventional water heat pipes might encounter the failure in a cold start-up operation when socked at a chilling temperature lower than the freezing point. If they are subjected to a heat supply for start-up at a temperature around $-20^{\circ}C$, the rate of the vapor flow and the corresponding heat transfer from the evaporator to the condenser is so small that the vapor keeps to stick on the surface of the chilling condenser wall, forming an ice layer, resulting in a liquid deficiency in the evaporator. This kind of problems was resolved by Kang et al. in 2004 by adopting a gas loading heat pipe technology to the conventional water heat pipes. This study was conducted to examine a chilling start-up procedure of gas loading heat pipes by investigating the behaviors of heat pipe wall temperatures. And the thermal resistance of the gas loaded heat pipe that depends on the operating temperatures and heat loads was measured and examined. Two water heat pipes were designed and fabricated for the comparison of performances, one conventional and the other loaded with $N_2$ gas. They were put on start-up test at a heat supply of 30 W after having been socked at an initial temperature around $-20^{\circ}C$. It was observed that the gas loaded one had succeeded in chilling start-up operation.

상수도시스템 수질사고 인지를 위한 유속기반 수질계측기 위치 결정 (Velocity-based decision of water quality measurement locations for the identification of water quality problems in water supply systems)

  • 홍성진;이찬욱;박지승;유도근
    • 한국수자원학회논문집
    • /
    • 제53권11호
    • /
    • pp.1015-1024
    • /
    • 2020
  • 최근 인천, 서울 적수 사고와 같은 관로 내 수질오염 사고가 지속적으로 발생되고 있다. 이러한 수질문제를 인지하기 위해서는 적절한 위치에 수질계측기를 설치하고 미리 계측하여 수용가의 수도꼭지까지 물 공급이 되기 이전에 발견 혹은 차단할 필요가 있다. 그러나 모든 관로에 수질계측기를 다수 설치하는 것에는 유지비용증대와 같은 한계점이 존재한다. 따라서 본 연구에서는 관로 내 수질문제 인지를 위한 유속기반의 수질계측기 설치위치를 결정하고 우선순위를 선정하는 방법론을 제안하였다. 제안된 절차를 관 파괴 시나리오와 국내에서 실제 운영 중인 비상연계관로가 포함된 관망운영 시나리오에 적용해 수질계측기 위치를 결정하고 결과를 분석하였다. 결정 결과 개별적인 관로의 파괴와 비상연계에 의한 비정상상황 발생시 대수용가와 탱크 주변, 그리고 비상연계관로 인근에 위치한 관로의 유속이 급격히 변하여 탁수발생에 의한 수질사고가 나타날 수 있을것으로 나타났다. 제안된 유속기반의 수질계측기 위치 결정 절차는 향후 관 청소를 위한 차단 및 비상관로 운영 계획 수립 등 수질모니터링 지점 선정 기법으로 활용 가능할 것으로 기대된다.

U-City/BIM USN 고도화를 위한 상수도배관용 자기유체발전 기술 개발 (Development of Waterworks Piping MHD Technology for USN Advancement in U-City/BIM)

  • 황정래;이현동;오윤석;곽필재;김지은
    • 상하수도학회지
    • /
    • 제26권4호
    • /
    • pp.555-563
    • /
    • 2012
  • Due to the importance of energy-saving and CO2 reduction is being emphasized in the world, efforts to find a solution for the problems is increasing rapidly. In particular, the renewable energy is on understanding as a breakthrough for the protection of the environment and the economic development, so it is intensively fostered as future industries. Developed countries are already pursuing policy and technology development related with renewable energy. In this paper, we will develop MHD(Magneto Hydro Dynamics) technology to supply the commercial power that can is targeted at water pipe related with hydro power among renewable energy technologies. Kinetic energy of fluid flowing in the water pipe is converted into electric power. It allows stable power supply to the various sensors and devices on water pipe. We have performed several experiments to verify the application possibility of the developed technologies and present the result and a method of performance improvement of the technologies.

급수관로계에 설치된 수격흡수기의 수격흡수효과에 관한 실험적 연구 (Experimental Study on the Water Hammer Absorption Effects of Water Hammer Arrester in the Water Supply Piping System)

  • 최중근;이석종;이명호;성재용
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제30권3호
    • /
    • pp.396-402
    • /
    • 2006
  • In this study, dynamic characteristics of water hammer pressure in water supply piping system with water hammer arrester has been investigated experimentally to characterize the transient pressure of water hammer in high rise building. Experiments were conducted to verify the absorption effects by water hammer arresters with 3 different gas volumes of water hammer pressure generated by sudden valve closure. As the results, it has been found that zoning and sizing of pipe diameter for suitable flow velocity and water hammer arresters with effective pressure absorption capacity have to be installed to protect water hammer problems in building water supply piping system.

흑염소 축사시설에 관한 실태조사 연구 (A Study of Investigation the Actual conditions on Housing and Facilities for Korean Native Goat)

  • 최순호;정광화;조영무;강희설;김원호;김영근
    • 한국축산시설환경학회지
    • /
    • 제7권1호
    • /
    • pp.13-20
    • /
    • 2001
  • This study was conducted to investigate the actual conditions on housing and facilities for goat. This investigation of the actual conditions was investigated by the style of farm which was divided into sideline scale and speciality scale included 47 farms. The results are summarized as follows: Rearing scale was 48.9% for 50-100 heads per farm. Rearing type was 46.8% for grazing type and 53.2% for barn type. Housing type was 27.7% for simple frame housing and 72.3% for permanent housing. Pipe was used 80.8% with Pillar and Girder as the housing frame at farm. For the pipe used in farm, 27.7% of them was used for simple frame housing. Side wall was composed of cement and winch curtain to be 29.8%, slate roof to be 40.4%, pipe partition to be 38.3%, and cement floor to be 51.1%. Materials of feeding trough were wood and Zinc grater to be 41.5%, respectively. Type of feeding trough was square to be 70.2%. The feeding trough was located in barn to be 48.9%. Material of water supply facilities was plastic to be 87.2%. Type of water supply facilities was mostly square to be 76.6%. Water-trough was located in playground to be 48.9%. Parturition facilities were consisted of partition structure by group to be 42.5% and were mainly composed of pipe and wood. 46.8% of the barn did not have delivery room in the farm.

  • PDF

대구경 관로의 노후도 평가 연구(II) : 수도권 광역상수도(1단계) 적용 (Assessment of the Deterioration of Large-Diameter Pipe Networks (II) : Application to Metropolitan Multi-Regional Water Supply System (1st Phase))

  • 이승현;윤기용;김응석
    • 한국산학기술학회논문지
    • /
    • 제15권2호
    • /
    • pp.1096-1101
    • /
    • 2014
  • 본 연구(II)는 연구(I)에서 제안한 대구경 관로의 노후도 평가 모형을 수도권 광역상수도 1단계를 대상으로 이를 적용하였다. 노후도 평가 방법별 적용 결과에서, 총 30개 관로 중에서 1995년 평가방법은 24개, 2002년 평가방법은 27개 관로가 개량이 필요한 것으로 나타났다. 또한 개발된 모형과 기존의 2개 평가방법의 결과는 거의 일치하는 것으로 산정되었다. 즉, 본 연구에서 개발한 간편모형은 기존의 많은 인자를 이용하여 노후도를 평가하는 방법과 비교에서 신뢰할 수 있는 부합되는 결과를 보여 주었다. 따라서, 본 연구에서 개발한 모형은 기존의 노후관 평가방법과 비교시 실험 및 분석 등에 필요한 시간적 경제적 비용을 절약할 수 있어 실무적 적용에 많은 도움을 줄 수 있으리라 기대된다.

외기온도 변화에 따른 집단에너지 공동주택의 최적 열공급제어 알고리즘 개발에 관한 연구 (Study on the Development of Optimal Heat Supply Control Algorithm in Group Energy Apartment Building According to the Variation of Outdoor Air Temperature)

  • 변재기;이규호;최영돈;신종근
    • 설비공학논문집
    • /
    • 제23권5호
    • /
    • pp.334-341
    • /
    • 2011
  • In the present study, optimal heat supply algorithm which minimize the heat loss through the distribution pipe line in group energy apartment was developed. Variation of heating load of group energy apartment building in accord with the outdoor air temperature was predicted by the heating load-outdoor temperature correlation. Supply water temperature and mass flow rate were controlled to minimize the heat loss through distribution pipe line. District heating apartment building located in Hwaseong city, which has 1,473 households, was selected as the object building for testing the present heat supply a1gorithm. Compared to the previous heat supply system, 10.4% heat loss reduction can be accomplished by employing the present method.

지역난방 에너지 공동주택의 다중 열공급 제어 알고리즘 개발에 관한 해석적 연구 (Study on the Development of Multi Heat Supply Control Algorithm in Apartment Building of District Heating Energy)

  • 변재기;최영돈;박명호;신종근
    • 한국기계기술학회지
    • /
    • 제13권2호
    • /
    • pp.63-70
    • /
    • 2011
  • In the present study, we developed optimal heat supply algorithm which minimizes the heat loss through the distribution pipe line in group energy apartment. Heating load variation of group energy apartment building in accordance with outdoor air temperature was predicted by the correlation obtained from calorimeter measurements of whole households of apartment building. Supply water temperature and mass flow rate were conjugately controlled to minimize the heat loss rate through distribution pipe line. Group heating apartment located in Hwaseong city, Korea, which has 1,473 households divided in 4 regions, was selected as the object apartment for verifying the present heat supply control algorithm. Compared to the original heat supply system, 10.4% heat loss rate reduction can be accomplished by employing the present control algorithm.

전자제어 장치를 이용한 세라믹 파이프의 온수제어기 개발 (A Controller Development of Water Heating in a Ceramic Pipe Using Electronics Control System)

  • 이정석
    • 한국전자통신학회논문지
    • /
    • 제6권5호
    • /
    • pp.717-722
    • /
    • 2011
  • 본 논문은 원통형 세라믹관에서 온수를 순간적으로 가열하여 설정된 온도 및 수량으로 제어하고자 전자 제어기를 개발하였다. 순간온수기의 구조는 유입되는 온수가 원통형 세라믹 히터를 통하여 열량을 공급하여 온도를 제어하고자 설계하였고, 또한 수량센서와 임펠러를 이용한 수량을 제어하는 전자 제어기를 설계하였다. 순간온수의 제어방법은 유입되는 유량에 열량을 공급하는 원통형 세라믹 히터의 수학적인 모델링을 수립하여 제어기 적용하였고, 이에 대한 실험결과는 설정온도에 따라 제어가 잘 적용되어, 효율적이고 실용성 결과를 보였다. 따라서 원통형 세라믹 순간온수기는 향후 실용제품에 적용할 수 있는 제품구조와 제어 방법을 제시하였다.

위기대응 취약성 분석을 통한 광역상수도 연계운영 평가 (Evaluation for conjunctive operation of multi-regional water supply system through risk analysis)

  • 황진수;최태호;홍공현;이두진;구자용
    • 상하수도학회지
    • /
    • 제33권4호
    • /
    • pp.269-279
    • /
    • 2019
  • This study would present a risk analysis method to evaluate stable tap water supply in a multi-regional water supply system and propose a measure for the evaluation of the effect of the conjunctive operation of the multi-regional water supply system using this. Judging from the vulnerability for the crisis response of the entire N. multi-regional water supply system, as compared to the result of Scenario 1 in which no conjunctive pipes were operated, it was found that in Scenario 2, in which conjunctive pipes were partially operated, the vulnerability of crisis response decreased by about 30.6%, and as compared to Scenario 3, the vulnerability of crisis response decreased by 86.2%. In setting a plan for stable tap water supply in N multi-regional water supply system, using the estimated value and the method for the evaluation of the vulnerability of crisis response by pipe, by interval and by line, it is judged that this can be utilized as a basis for the judgment of the evaluation of the operation or the additional installation of conjunctive pipes.