• 제목/요약/키워드: Water pipe supply

검색결과 265건 처리시간 0.021초

수도관로 소수력발전설비에 수격작용으로 인한 고장대책 (Trouble and Measure Owing to Water-hammer in Small Hydropower Turbine System Of Waterpipe)

  • 이형묵;김기원;변일환;홍정조;이은웅
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 B
    • /
    • pp.671-672
    • /
    • 2006
  • Recently the development of small hydropower generation with using water pipes is revitalized by the water works facilities. However, when the tubine generator is in case of emergency stop by the internal and external accidents, it causes water hammer in water pipes and suspension of water supply. To prevent these problems of small hydropower generator, we has analyzed water supply patterns, installation position and water pipe systems.

  • PDF

수도관로 소수력발전설비에서의 수격작용으로 인한 고장대책 (Trouble and Measure Owing to Water-hammer In Small Hydropower Turbine System Of Waterpipe)

  • 이형묵;홍정조;이은웅;김경엽
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2006년 제4회 한국유체공학학술대회 논문집
    • /
    • pp.61-64
    • /
    • 2006
  • Recently the development of small hydropower generation with using water pipes is revitalized by the water works facilities. However, when the tubine generator is in case of emergency stop by the internal and external accidents, it causes water hammer in water pipes and suspension of water supply. To prevent these problems of small hydropower generator, we has analyzed water supply patterns, installation position and water pipe systems.

  • PDF

지하매설 배관의 탐사 및 도장을 위한 로봇시스템 개발 (Development of a Robot System for Monitoring and Repairing a Underground Pipe)

  • 여희주;성문현
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 심포지엄 논문집 정보 및 제어부문
    • /
    • pp.346-348
    • /
    • 2007
  • Underground pipe is an instrument to transport rapidly and safely a lot of fluid like gas, oil, water supply and drain system. It acts like blood vessels of human body in a modern industry. As in this country, the pipe facilities have been constructing since 1970's. The pipes constructed for a long time ago are already starting to reveal the problem like corrosion and most of them are built underground. So for companies, the managing of the underground pipes is very hard because it needs high technology and a lot of money. So we made a new robot system to repair and maintain the pipes at a low price. This new robot is devised using pressing wall type to work inside 700${\sim}$900(mm) size pipe. And it has good carrying and working power.

  • PDF

수량화II류이론을 활용한 상수도관로의 안전성 평가 모델 개발 및 적용성 평가 연구 (A Study on the Development and Applicative Estimation of Safety Evaluation Model for Water Supply Pipelines using Quantification Theory Type II)

  • 김기범;신휘수;서지원;구자용
    • 상하수도학회지
    • /
    • 제30권1호
    • /
    • pp.59-67
    • /
    • 2016
  • Owing to time and cost constraints, new methods that would make it possible to evaluate the safety of the water supply pipeline in a less time- and cost-consuming manner are urgently needed. In response to this exigency, the present study developed a new statistical model to assess the safety of the water supply pipeline using the quantification theory type II. In this research, the safety of the water supply pipeline was defined as 'a possibility of the pipeline failure'. Quantification analysis was conducted on the qualitative data, such as pipe material, coating, and buried condition. The results of analyses demonstrate that the hit ratio of the quantification function amounted to 77.8% of hit ratio, which was a fair value. In addition, all variables that were included in the quantification function were logically valid and demonstrated statistically significant. According to the results derived from the application of the safety evaluation model, the coefficient of determination ($R^2$) between K-region's water supply pipeline safety and the safety inspection amounted to 0.80. Therefore, these findings provide meaningful insight for the measured values in real applications of the model. The results of the present study can also be meaningfully used in further research on safety evaluation of pipelines, establishing of renewal prioritization, as well as asset management planning of the water supply infrastructure.

대구경 상수도관 부식 손상부의 고분자 필러와 복합슬리브 성능 평가 (Performance assessment of polymeric filler and composite sleeve technique for corrosion damage on large-diameter water pipes)

  • 이호민;박정수;박정주;배철호
    • 상하수도학회지
    • /
    • 제37권4호
    • /
    • pp.203-214
    • /
    • 2023
  • In this study, the physical properties and fracture characteristics according to the tensile load are evaluated on the materials of the polymeric filler and carbon fiber-based composite sleeve technique. The polymeric filler and the composite sleeve technique are applied to areas where the pipe body thickness is reduced due to corrosion in large-diameter water pipes. First, the tensile strength of the polymeric filler was 161.48~240.43 kgf/cm2, and the tensile strength of the polyurea polymeric filler was relatively higher than that of the epoxy. However, the tensile strength of the polymeric filler is relatively very low compared to ductile cast iron pipes(4,300 kgf/cm2<) or steel pipes(4,100 kgf/cm2). Second, the tensile strength of glass fiber, which is mainly used in composite sleeves, is 3,887.0 kgf/cm2, and that of carbon fiber is up to 5,922.5 kgf/cm2. The tensile strengths of glass and carbon fiber are higher than ductile cast iron pipe or steel pipe. Third, when reinforcing the hemispherical simulated corrosion shape of the ductile cast iron pipe and the steel pipe with a polymeric filler, there was an effect of increasing the ultimate tensile load by 1.04 to 1.06 times, but the ultimate load was 37.7 to 53.7% compared to the ductile cast iron or steel specimen without corrosion damage. It was found that the effect on the reinforcement of the corrosion damaged part was insignificant. Fourth, the composite sleeve using carbon fiber showed an ultimate load of 1.10(0.61T, 1,821.0 kgf) and 1.02(0.60T, 2,290.7 kgf) times higher than the ductile cast iron pipe(1,657.83 kgf) and steel pipe(2,236.8 kgf), respectively. When using a composite sleeve such as fiber, the corrosion damage part of large-diameter water pipes can be reinforced with same level as the original pipe, and the supply stability can be secured through accident prevention.

부식억제제에 의한 상수도관의 피막 형성 및 수질개선 효과 (Coating formation of water supply pipes by inhibitor and water quality improvement effect)

  • 임재철;김진근;구자용
    • 상하수도학회지
    • /
    • 제26권1호
    • /
    • pp.97-106
    • /
    • 2012
  • To investigate the application of corrosion inhibitor on water supply pipes, turbidity, magnitude of corrosion, composition of scale and concentration of metals from an old steel pipe were analysed under inhibitor addition. The concentration of turbidity, iron and copper from the pipes under inhibitor application was 12 ~ 14% of the case which no inhibitor was applied, which suggests the application of inhibitor was very effective for internal corrosion control. In addition, SEM, EDX, XRD and XRF test results showed that application of inhibitor was effective for the decrease of iron concentration and increase of oxygen, phosphorus and calcium concentration, which suggested the existence of protective layer. Therefore, the occurrence of red water will be significantly decreased when inhibitor was applied to the old steel pipes.

적응 칼만필터를 이용한 상수관망의 누수감시 기법 (Leakage Detection of Water Distribution System using Adaptive Kalman Filter)

  • 김성원;최두용;배철호;김주환
    • 한국수자원학회논문집
    • /
    • 제46권10호
    • /
    • pp.969-976
    • /
    • 2013
  • 수돗물의 공급과정에서 발생되는 상수관망의 누수는 소중한 수자원의 손실, 공급에너지의 추가적인 소요 등 사회경제적인 손실을 초래한다. 본 연구에서는 관로 상에 설치되어 실시간으로 계측되는 유량자료를 이용하여 누수를 감시하는 모형을 적응 칼만필터 기법을 이용하여 제시하였다. 제안된 누수감시 알고리즘에서는 수돗물 사용량의 시간적 변화와 요일적 변동을 고려함으로써 예측의 신뢰도를 향상시키는 방안을 제시하였다. 또한 기존의 칼만필터 기법에 혁신과정을 추가하여 잡음의 공분산에 대한 자동보정을 통하여 예측의 정확도를 개선하였다. 개발된 모형은 사인형태의 가상 유량자료에 대한 모의실험을 통하여 적응 칼만필터 기법의 예측정확도를 기존의 칼만필터 기법과 비교하였으며, JE시의 2개소 블록유량자료에 대한 현장 적용성 평가를 실시하였다. 본 연구의 결과는 관로의 파열에 의한 누수 및 비정상적인 용수사용량에 대한 감시를 통하여 상수관망의 효율적인 운영관리에 적용될 수 있을 것으로 기대된다.

수경재배 온실의 양액냉각시스템 개발 (Development of Nutrient Solution Cooling System in Hydroponic Greenhouse)

  • 남상운;김문기
    • 한국농공학회지
    • /
    • 제36권3호
    • /
    • pp.113-121
    • /
    • 1994
  • Since it is difficult to expect the normal production of plants in greenhouses during hot summer season in Korea, certain provisions on the control of extreme environmental factors in summer should be considered for the year-round cultivation in greenhouses. This study was carried out to find a method to suppress the temperature rising of nutrient solution by cooling, which is able to contribute to the improvement of the plant growth environment in hydroponic greenhouse during hot summer season. A mechanical cooling system using the counter flow type with double pipe was developed for cooling the nutrient solution efficiently. Also the heat transfer characteristics of the system was analysed experimentally and theoretically, and compared with the existing cooling systems of nutrient solution. The cooling capacities of three different Systems, which used polyethylene tube in solution tank, stainless tube in solution tank, and the counter flow type with double pipe, were evaluated. The performance of each cooling system was about 41 %, 70% and 81 % of design cooling load in hydroponic greenhouse of 1 ,000m$^2$ on the conditions that the flow rate of ground water was 2m$^3$/hr and the temperature difference between two liquids was 10 ˚C According to the results analysed as above, the cooling system was found to have a satisfactory cooling capability for regions where ground water supply is available. Fer the other regions where ground water supply is restricted, more efficient cooling System should be developed.

  • PDF

대구경 관로의 배수시간 산정을 위한 수치해석 기법 (A Numerical Method to Calculate Drainage Time in Large Transmission Pipelines Filter)

  • 신병호;최두용;정관수
    • 상하수도학회지
    • /
    • 제31권6호
    • /
    • pp.511-519
    • /
    • 2017
  • Multi-regional water supply system, which installed for supplying multiple water demands, is characterized by large-sized, long-distance, tree-type layout. This system is vulnerable to long-standing service interruption when a pipe breaks is occurred. In this study, a numerical method is proposed to calculate drainage time that directly affects time of service interruption. To begin with, governing equations are formulated to embed the delayed drainage effect by the friction loss, and to resolve complicated connection of pipelines, which are derived from the continuity and energy equations. The nonlinear hydraulic equations are solved by using explicit time integration method and the Newton-Raphson method. The developed model is verified by comparing the result with analytical solution. Furthermore, the model's applicability is validated by the examples of pipelines in serial, in parallel, and complex layout. Finally, the model is utilized to suggest an appropriate actions to reduce the deviation of draining time in the C transmission line of the B multi-regional water supply system.

동절기 수압시험을 대체하는 공기압시험의 적정압력 비교분석에 관한 연구 (Winter to replace the hydraulic test and pneumatic test comparative analysis of study on the optimal pressure)

  • 권영희;황동환;김태길;강경식
    • 대한안전경영과학회지
    • /
    • 제16권2호
    • /
    • pp.211-216
    • /
    • 2014
  • Using a high-rise building water piping after hydrostatic test of the reliability of the leak to be completed if the pressure is maintained until the leak is not commercially available considered. Due to the nature of high-rise buildings and the construction period will take several years from the lower levels of use of the water supply and fire fighting water pipe construction is in progress, the order of which I do most of the first pipe to the construction and more than three years. So kind of riser pipe is complete, install the valve in the basement by installing an automatic pump to maintain a constant pressure after hydrostatic test and after each floor plumbing piping is complete, the progress of the hydrostatic test without undergoing a separate branch pipe the valve is opened automatically when the number of the pressing pressure of the structure. I kind of do and keep working pressure of pipe until the completion of the construction work to keep the damage to human error when it is intended to prepare. In winter, the frost protection and an alternative to drainage water pipe is damaged or deformed, even if unaware of the finishing work to the building, the use of the damage caused by a leak in a after construction of finish work to be expected. Alternative to reduce this damage if the pressure test without fear of freezing to help maintain long-term commercial pressures may be considered.