• Title/Summary/Keyword: Water pipe supply

Search Result 265, Processing Time 0.03 seconds

A Study on the Chilling Start-up Characteristics and Performance of a Gas Loaded Heat Pipe (가스내장 히트파이프의 냉시동특성과 성능에 관한 연구)

  • Hong, Sung-Eun;Kang, Hwan-Kook
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.18 no.11
    • /
    • pp.915-922
    • /
    • 2006
  • Considering heat pipe design principles in fabrication and operational performances, water is one of the most recommended working fluids to make mid to low tempera lure heat pipes. But the conventional water heat pipes might encounter the failure in a cold start-up operation when socked at a chilling temperature lower than the freezing point. If they are subjected to a heat supply for start-up at a temperature around $-20^{\circ}C$, the rate of the vapor flow and the corresponding heat transfer from the evaporator to the condenser is so small that the vapor keeps to stick on the surface of the chilling condenser wall, forming an ice layer, resulting in a liquid deficiency in the evaporator. This kind of problems was resolved by Kang et al. in 2004 by adopting a gas loading heat pipe technology to the conventional water heat pipes. This study was conducted to examine a chilling start-up procedure of gas loading heat pipes by investigating the behaviors of heat pipe wall temperatures. And the thermal resistance of the gas loaded heat pipe that depends on the operating temperatures and heat loads was measured and examined. Two water heat pipes were designed and fabricated for the comparison of performances, one conventional and the other loaded with $N_2$ gas. They were put on start-up test at a heat supply of 30 W after having been socked at an initial temperature around $-20^{\circ}C$. It was observed that the gas loaded one had succeeded in chilling start-up operation.

Velocity-based decision of water quality measurement locations for the identification of water quality problems in water supply systems (상수도시스템 수질사고 인지를 위한 유속기반 수질계측기 위치 결정)

  • Hong, Sungjin;Lee, Chanwook;Park, Jiseung;Yoo, Do Guen
    • Journal of Korea Water Resources Association
    • /
    • v.53 no.11
    • /
    • pp.1015-1024
    • /
    • 2020
  • Recently, water pollution accidents have continued to occur in pipelines such as red water Incheon and Seoul. In order to recognize this water quality problem, it is necessary to install a water quality sensor in an appropriate location and measure it in advance to detect or block the water supply to the water faucet of the shelter. However, there are limitations, such as maintenance costs, to installing multiple water meters in all pipelines. Therefore, this study proposed a methodology for determining and prioritizing the installation location of flow-based water quality sensor for the recognition of water quality problems in pipelines. We applied the proposed procedure to the pipe break scenario. The results of the determination of the location of the water quality sensor were presented by applying it to the pipe network that actually operates the emergency pipe in Korea. The result of the decision showed that in the event of abnormal situation caused by the destruction of individual pipes, the flow rate of the pipes around the aqueduct and the tank may change rapidly, resulting in water quality accidents caused by turbidity. In the future, it is expected that the water quality monitoring point selection method, such as establishing an external pipe operation plan for pipe cleaning, will utilize the procedure for determining the location of the water quality sensor according to the velocity.

Development of Waterworks Piping MHD Technology for USN Advancement in U-City/BIM (U-City/BIM USN 고도화를 위한 상수도배관용 자기유체발전 기술 개발)

  • Hwang, Jung-Rae;Lee, Hyun-Dong;Oh, Yoon-Seuk;Kwak, Pill-Jae;Kim, Gi-Eun
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.26 no.4
    • /
    • pp.555-563
    • /
    • 2012
  • Due to the importance of energy-saving and CO2 reduction is being emphasized in the world, efforts to find a solution for the problems is increasing rapidly. In particular, the renewable energy is on understanding as a breakthrough for the protection of the environment and the economic development, so it is intensively fostered as future industries. Developed countries are already pursuing policy and technology development related with renewable energy. In this paper, we will develop MHD(Magneto Hydro Dynamics) technology to supply the commercial power that can is targeted at water pipe related with hydro power among renewable energy technologies. Kinetic energy of fluid flowing in the water pipe is converted into electric power. It allows stable power supply to the various sensors and devices on water pipe. We have performed several experiments to verify the application possibility of the developed technologies and present the result and a method of performance improvement of the technologies.

Experimental Study on the Water Hammer Absorption Effects of Water Hammer Arrester in the Water Supply Piping System (급수관로계에 설치된 수격흡수기의 수격흡수효과에 관한 실험적 연구)

  • Choi, Jung-Geun;Lee, Suk-Jong;Lee, Myoeng-Ho;Sung, Jae-Yong
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.30 no.3
    • /
    • pp.396-402
    • /
    • 2006
  • In this study, dynamic characteristics of water hammer pressure in water supply piping system with water hammer arrester has been investigated experimentally to characterize the transient pressure of water hammer in high rise building. Experiments were conducted to verify the absorption effects by water hammer arresters with 3 different gas volumes of water hammer pressure generated by sudden valve closure. As the results, it has been found that zoning and sizing of pipe diameter for suitable flow velocity and water hammer arresters with effective pressure absorption capacity have to be installed to protect water hammer problems in building water supply piping system.

A Study of Investigation the Actual conditions on Housing and Facilities for Korean Native Goat (흑염소 축사시설에 관한 실태조사 연구)

  • 최순호;정광화;조영무;강희설;김원호;김영근
    • Journal of Animal Environmental Science
    • /
    • v.7 no.1
    • /
    • pp.13-20
    • /
    • 2001
  • This study was conducted to investigate the actual conditions on housing and facilities for goat. This investigation of the actual conditions was investigated by the style of farm which was divided into sideline scale and speciality scale included 47 farms. The results are summarized as follows: Rearing scale was 48.9% for 50-100 heads per farm. Rearing type was 46.8% for grazing type and 53.2% for barn type. Housing type was 27.7% for simple frame housing and 72.3% for permanent housing. Pipe was used 80.8% with Pillar and Girder as the housing frame at farm. For the pipe used in farm, 27.7% of them was used for simple frame housing. Side wall was composed of cement and winch curtain to be 29.8%, slate roof to be 40.4%, pipe partition to be 38.3%, and cement floor to be 51.1%. Materials of feeding trough were wood and Zinc grater to be 41.5%, respectively. Type of feeding trough was square to be 70.2%. The feeding trough was located in barn to be 48.9%. Material of water supply facilities was plastic to be 87.2%. Type of water supply facilities was mostly square to be 76.6%. Water-trough was located in playground to be 48.9%. Parturition facilities were consisted of partition structure by group to be 42.5% and were mainly composed of pipe and wood. 46.8% of the barn did not have delivery room in the farm.

  • PDF

Assessment of the Deterioration of Large-Diameter Pipe Networks (II) : Application to Metropolitan Multi-Regional Water Supply System (1st Phase) (대구경 관로의 노후도 평가 연구(II) : 수도권 광역상수도(1단계) 적용)

  • Lee, Seung-Hyun;Yoon, Ki-Yong;Kim, Eung-Seok
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.2
    • /
    • pp.1096-1101
    • /
    • 2014
  • This study (II) has appled the new assessment model of large-diameter pipe deterioration proposed by the study (I) to the metropolitan multi-regional water supply system (1st phase). In the total 30 pipelines, 24 and 27 pipelines were required for improvement as results from the existing evaluation methods 1995 and 2002, respectively. The assessment results were almost similar in the new developed model and the existing methods. It is founded that the new simple model developed in this study can produce reliable results, consistent with those from the existing methods requiring many factors for a pipe deterioration assessment. It is therefore expected that the new model would be helpful in practical applications of a pipe deterioration assessment since it can save both temporal and economic costs for experiments and analysis, as compared with existing assessment methods.

Study on the Development of Optimal Heat Supply Control Algorithm in Group Energy Apartment Building According to the Variation of Outdoor Air Temperature (외기온도 변화에 따른 집단에너지 공동주택의 최적 열공급제어 알고리즘 개발에 관한 연구)

  • Byun, Jae-Ki;Lee, Kyu-Ho;Cho, Young-Don;Shin, Jong-Keun
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.23 no.5
    • /
    • pp.334-341
    • /
    • 2011
  • In the present study, optimal heat supply algorithm which minimize the heat loss through the distribution pipe line in group energy apartment was developed. Variation of heating load of group energy apartment building in accord with the outdoor air temperature was predicted by the heating load-outdoor temperature correlation. Supply water temperature and mass flow rate were controlled to minimize the heat loss through distribution pipe line. District heating apartment building located in Hwaseong city, which has 1,473 households, was selected as the object building for testing the present heat supply a1gorithm. Compared to the previous heat supply system, 10.4% heat loss reduction can be accomplished by employing the present method.

Study on the Development of Multi Heat Supply Control Algorithm in Apartment Building of District Heating Energy (지역난방 에너지 공동주택의 다중 열공급 제어 알고리즘 개발에 관한 해석적 연구)

  • Byun, J.K.;Choi, Y.D.;Park, M.H.;Shin, J.K.
    • Journal of the Korean Society of Mechanical Technology
    • /
    • v.13 no.2
    • /
    • pp.63-70
    • /
    • 2011
  • In the present study, we developed optimal heat supply algorithm which minimizes the heat loss through the distribution pipe line in group energy apartment. Heating load variation of group energy apartment building in accordance with outdoor air temperature was predicted by the correlation obtained from calorimeter measurements of whole households of apartment building. Supply water temperature and mass flow rate were conjugately controlled to minimize the heat loss rate through distribution pipe line. Group heating apartment located in Hwaseong city, Korea, which has 1,473 households divided in 4 regions, was selected as the object apartment for verifying the present heat supply control algorithm. Compared to the original heat supply system, 10.4% heat loss rate reduction can be accomplished by employing the present control algorithm.

A Controller Development of Water Heating in a Ceramic Pipe Using Electronics Control System (전자제어 장치를 이용한 세라믹 파이프의 온수제어기 개발)

  • Lee, Jung-Suk
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.6 no.5
    • /
    • pp.717-722
    • /
    • 2011
  • This paper presents that the electronic controller is developed for controlling the setting temperature and water in the ceramic pipe system. The heating water system is designed for controlling the temperature to supply the heat through the ceramic pipe heater to input the water, also for controlling quantity of water using the water sensor and impeller. The control method of the heating water system is applied the mathematic modeling of the ceramic pipe heater on the suppling the heat at coming water, and the test result of the electronic controller is present to smartly control the setting temperature, therefore the ceramic pipe heater is proposed to be able to apply the heating structure and the control methods as a product.

Evaluation for conjunctive operation of multi-regional water supply system through risk analysis (위기대응 취약성 분석을 통한 광역상수도 연계운영 평가)

  • Hwang, Jinsoo;Choi, Taeho;Hong, Gonghyun;Lee, Doojin;Koo, Jayong
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.33 no.4
    • /
    • pp.269-279
    • /
    • 2019
  • This study would present a risk analysis method to evaluate stable tap water supply in a multi-regional water supply system and propose a measure for the evaluation of the effect of the conjunctive operation of the multi-regional water supply system using this. Judging from the vulnerability for the crisis response of the entire N. multi-regional water supply system, as compared to the result of Scenario 1 in which no conjunctive pipes were operated, it was found that in Scenario 2, in which conjunctive pipes were partially operated, the vulnerability of crisis response decreased by about 30.6%, and as compared to Scenario 3, the vulnerability of crisis response decreased by 86.2%. In setting a plan for stable tap water supply in N multi-regional water supply system, using the estimated value and the method for the evaluation of the vulnerability of crisis response by pipe, by interval and by line, it is judged that this can be utilized as a basis for the judgment of the evaluation of the operation or the additional installation of conjunctive pipes.