• Title/Summary/Keyword: Water pipe supply

Search Result 265, Processing Time 0.03 seconds

Limit Loads for Circular Wall-Thinned Feeder Pipes Considering Bend Angle (굽힘각도를 고려한 원형 감육이 발생한 중수로 피더관의 한계하중)

  • Bae, Kyung-Dong;Je, Jin-Ho;Kim, Jong-Sung;Kim, Yun-Jae
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.36 no.3
    • /
    • pp.313-318
    • /
    • 2012
  • In CANDU, feeder pipes supply heavy water to pressure tube and steam generator. Under service conditions, Flow-Accelerated Corrosion (FAC) produces local wall-thinning in the feeder pipes. The wall-thinning in these pipes affects the integrity of the piping system, as verified in previous research. This paper provides limit loads for wallthinned feeder pipes with $45^{\circ}$ and $60^{\circ}$ bend angles, and proposes an equation that predicts the limit loads for wallthinned feeder pipes with arbitrary bend angles. On the basis of finite element limit analyses, limit loads are obtained for wall-thinned feeder pipes under in-plane bending and internal pressure. There are two cases of in-plane bending: the in-plane closing direction and the in-plane opening direction. The material is considered the effect of the large deformation, so an elastic-perfectly-plastic material is assumed in the calculations.

Performance Improvement of Cross-Flow type Small Hydro Turbine by Air Layer Effect (소수력발전용 횡류수차의 공기층효과에 의한 성능향상)

  • Choi, Young-Do;An, Young-Joon;Shin, Byeong-Rog;Lee, Dong-Yeup;Lee, Young-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.1070_1071
    • /
    • 2009
  • Recently, small hydropower attracts attention because of its clean, renewable and abundant energy resources to develop. Therefore, a cross-flow hydraulic turbine is proposed for small hydropower development in this study. The turbine‘s simple structure and high possibility of applying to the sites of relatively low effective head and large flow rate can be advantages for the introduction of the small hydropower development. The purpose of this study is not only to investigate the effects of air layer in the turbine chamber on the performance and internal flow of the cross-flow turbine, but also to suggest a newly developed air supply method. CFD analysis for the performance and internal flow of the turbine is conducted by an unsteady state calculation using a two-phase flow model in order to embody the air layer effect on the turbine performance effectively. The result shows that air layer effect on the performance of the turbine is considerable. The air layer located in the turbine runner passage plays the role of preventing a shock loss in the runner axis and suppressing a recirculation flow in the runner. The location of air suction hole on the chamber wall is very important factor for the performance improvement. Moreover, the ratio between air from suction pipe and water from turbine inlet is also significant factor of the turbine performance.

  • PDF

A Safety Improvement for the Design Change of Westinghouse 2 Loop Auxiliary Feedwater System (웨스팅하우스형 원전의 보조급수계통 설계변경 영향 평가)

  • Na, Jang Hwan;Bae, Yeon Kyoung;Lee, Eun Chan
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.9 no.1
    • /
    • pp.15-19
    • /
    • 2013
  • The auxiliary feedwater is an important to remove the heat from the reactor core when the main feedwater system is unavailable. In most initiating events in Probabilistic Safety Assessment(PSA), the operaton of this system is required to mitigate the accidents. For one of domestic nuclear power plants, a design change of a turbine-driven auxiliary feedwater pump(TD-AFWP), pipe, and valves in the auxiliary system is implemented due to the aging related deterioration by long time operation. This change includes the replacement of the TD-AFWP, the relocation of some valves for improving the system availability, a new cross-tie line, and the installation of manual valves for maintenance. The design modification affects the PSA because the system is critical to mitigate the accidents. In this paper, the safety effect of the change of the auxiliary feedwater system is assessed with regard to the PSA view point. The results demonstrate that this change can supply the auxiliary feedwater from the TD-AFWP in the accident with the motor-driven auxiliary feedwater pump(MD-AFWP) unavailable due to test or maintenance. In addition, the change of MOV's normal position from "close" to "open" can deliver the water to steam generator in the loss of offsite power(LOOP) event. Therefore, it is confirmed that the design change of the auxiliary feedwater system reduces the total core damage frequency(CDF).

Fatigue Evaluation of District Heat Pipes based on the Measured Data (실데이터 분석을 통한 지역난방 열배관의 피로안전성 평가)

  • Park, Jin-Eun;Kyung, Kab-Soo;An, Yong-Mo;Kwon, Soon-Cheol
    • Journal of Korean Society of Steel Construction
    • /
    • v.23 no.5
    • /
    • pp.569-579
    • /
    • 2011
  • Heating pipes, which are among the main equipment in district heating systems, can be classified into supply and return pipes. Because when the district heating transmission pipe, which is charged with district heating in small to medium-size cities, is under thermal stress during temperature variances in heating water, it suffers from the fatigue phenomenon caused by the thermal stress, according to the number of its service years. District heatingpipes have shown various characteristics according to the operating condition of the service connections, and the irregular temperature variance has had a bad influence on fatigue heating pipes. Therefore, in this study, a field test on laid heating pipes was performed, and the data for each region were analyzed. Also, the fatigue safety of district heating pipes was evaluated via cycle-based evaluation and stress-based evaluation.

An Experimental Study on the Damage of the Data Process Equipment When $CO_2$ is Discharged ($CO_2$ 소화설비 방사시 정보저장장치의 저온손상에 관한 연구)

  • 이수경;김종훈;김영진;최종운
    • Fire Science and Engineering
    • /
    • v.13 no.3
    • /
    • pp.19-26
    • /
    • 1999
  • $CO_2$ extinguishing system is the most $\phi$pular among the gas extinguishing system. $CO_2$ is usually stored with liquified state. But, it gasifies at the tip of nozzle when $CO_2$ was released through the pipe and head. A ro$\alpha$n temperature is very low when $CO_2$ was released. So electrical instrument, magnetic storage equipment and memory semiconductor are electrically or physically injured by cooling effect in a few minutes. So, we intend to find out temperature profile and electrical damage in compartment area, and supply basic d data for research and making standards and code through the full scale experiment. As result of experiment on the damage due to cooling effect from $CO_2$ extinguishing system, i instantaneous discharging temperature. was $-82.5^{\circ}C$ in average. An average temp. in the compartment after discharging $CO_2$ was $-40^{\circ}C$.

  • PDF

Motions of Semi-submersible Drilling Rigs in Deep Water (Semi-submersible 석유시추선(石油試錐船)(부체해양구조물(浮體海洋構造物))의 운동(運動) -계산방법(計算方法), 해석(解析) 및 응용(應用))

  • Jin-S.,Chung
    • Bulletin of the Society of Naval Architects of Korea
    • /
    • v.11 no.2
    • /
    • pp.23-40
    • /
    • 1974
  • Semisubmersible 해양석유시추선의 기본설계에 필요한 파랑중(波浪中)에서 운동(運動)을 계산(計算)하는 이론적방법(理論的方法)을 제시하고 "MOHOLE"과 "SEDCO 1350-F" 석유시추선들의 운동(運動)을 해석하였다. 이 규칙파에서 운동계산을 불규칙해양파(波)에 적용하는 응용해석을 보여주었다. 현재 이론적 방법으로는 6자유도(自由度)의 운동을 해양파의 어떤 방향에 대해서도 정확히 계산할 수 있으며 계산의 정확성은 수조(水槽)에서의 모형선의 운동측정치와 실선(實船)의 운동측정치와 비교하여 증명되었다. 또 현재의 방법은 종전에 개발된 방법보다 더 일반적(一般的)인 경우를 다룰 수 있으며 결과치도 더 정확하다. 극소운동특성을 갖는 해양석유시추선과 부체(浮體)해양구조물의 설계는 경비가 비싸고 시간이 많이 드는 모형실험보다는 유체역학적(流體力學的) Parameters를 신속 정확히 자주 변경 검토해야 하는 기본설계단계에서는 정확한 이론적인 전자계산기에 의한 계산방법이 절실히 필요하다. 예상(豫想)과 같은 부가질량(附加質量)과 감쇠력(減衰力)은 Resonance 운동주기에서만 운동에 영향을 준다. 해양구조물에 작용하는 파력(波力)은 Froude-Krilov force, 부가질량(附加質量) 및 감쇠력(減衰力)과 Restoring force로 구성했으며 규칙파(規則波)에서의 6자유도(自由度) 운동방정식은 본 논문에 제시된 실험측정치(値)와 실험으로 정확도가 증명된 이론치(値)의 부가질량과 감쇠력 계수(係數)를 써서 풀었다. 규칙파(規則波)에서의 계산된 운동을 Pierson Moskowitz 해양파(海洋波) 스펙트럼과 linear superposition principle에 의해 불규칙해양파(不規則海洋波)에서의 운동을 계산하는데 사용했다. 불규칙파(不規則波)에서의 운동은 운동스펙트럼과 통계적 운동치로 나타냈다. 현재의 계산방법은 실제 기본설게에 사용되어 왔으며, 다른 응용분야는 파랑중(波浪中)에서의 파면(波面)과 Deck간(間)의 Clearance, 계류선(係留線)의 동장력(動張力)계산의 기본 Data 및 기본설계의 Draft 등 Parameters를 통(通)한 Optimum Design 등(等)이다. 파(波)의 한 방향(方向)에 대(對)한 전자계산기(電子計算機)(IBM 370 또는 CDC 6400)에 의한 운동계산은 10초(秒)미만밖에 안걸린다. 또 현재의 계산방법은 해양석유시추선뿐 아니라 이와 비슷한 부체(浮體)해양구조물과 Pipe-laying선(船) 또 Supply Boat설계(設計)에도 쓰여지고 있다.

  • PDF

Development of 2D Data Quality Validation Techniques for Pipe-type Underground Facilities (2차원 관로형 지하시설물 정보 품질검증기술 개발)

  • Sang-Keun Bae;Sang-Min Kim;Eun-Jin Yoo;Keo-Bae Lim;Da-Woon Jeong
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.46 no.3
    • /
    • pp.285-292
    • /
    • 2023
  • As various accidents have occurred in underground spaces, we aim to improve the quality validation standards and methods as specified in the Regulations on Producing Integrated Map of Underground Spaces devised by the Ministry of Land, Infrastructure and Transport of the Republic of Korea for a high-quality integrated map of underground spaces. Specifically, we propose measures to improve the quality assurance of pipeline-type underground facilities, the so-called life lines given their importance for citizens' daily activities and their highest risk of accident among the 16 types of underground facilities. After implementing quality validation software based on the developed quality validation standards, the adequacy of the validation standards was demonstrated by testing using data from two-dimensional water supply facilities in some areas of Busan, Korea. This paper has great significance in that it has laid the foundation for reducing the time and manpower required for data quality inspection and improving data quality reliability by improving current quality validation standards and developing technologies that can automatically extract errors through software.

Advantages and disadvantages of renewable energy-oil-environmental pollution-from the point of view of nanoscience

  • Shunzheng Jia;Xiuhong Niu;Fangting Jia;Tayebeh Mahmoudi
    • Advances in concrete construction
    • /
    • v.16 no.1
    • /
    • pp.69-78
    • /
    • 2023
  • This investigation delves into the adverse repercussions stemming from the impact of arsenic on steel pipes concealed within soil designated for rice cultivation. Simultaneously, the study aims to ascertain effective techniques for detecting arsenic in the soil and to provide strategies for mitigating the corrosion of steel pipes. The realm of nanotechnology presents promising avenues for addressing the intricate intersection of renewable energy, oil, and environmental pollution from a novel perspective. Nanostructured materials, characterized by distinct chemical and physical attributes, unveil novel pathways for pioneering materials that exert a substantial impact across diverse realms of food production, storage, packaging, and quality control. Within the scope of the food industry, the scope of nanotechnology encompasses processes, storage methodologies, packaging paradigms, and safeguards to ensure the safety of consumables. Of particular note, silver nanoparticles, in addition to their commendable antibacterial efficacy, boast anti-fungal and anti-inflammatory prowess, environmental compatibility, minimal irritability and allergenicity, resilience to microbial antagonism, thermal stability, and robustness. Confronting the pressing issue of arsenic contamination within both environmental settings and the food supply is of paramount importance to preserve public health and ecological equilibrium. In response, this study introduces detection kits predicated upon silver nanoparticles, providing an expeditious and economically feasible avenue for identifying arsenic concentrations ranging from 0.5 to 3 ppm within rice. Subsequent quantification employs Hydride Atomic Absorption Spectroscopy (HG-AAS), which features a detection threshold of 0.05 ㎍/l. A salient advantage inherent in the HG-AAS methodology lies in its capacity to segregate analytes from the sample matrix, thereby significantly reducing instances of spectral interference. Importantly, the presence of arsenic in the soil beneath rice cultivation establishes a causative link to steel pipe corrosion, with potential consequences extending to food contamination-an intricate facet embedded within the broader tapestry of renewable energy, oil, and environmental pollution.

Recent Progress in Air-Conditioning and Refrigeration Research : A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2013 (설비공학 분야의 최근 연구 동향 : 2013년 학회지 논문에 대한 종합적 고찰)

  • Lee, Dae-Young;Kim, Sa Ryang;Kim, Hyun-Jung;Kim, Dong-Seon;Park, Jun-Seok;Ihm, Pyeong Chan
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.26 no.12
    • /
    • pp.605-619
    • /
    • 2014
  • This article reviews the papers published in the Korean Journal of Air-Conditioning and Refrigeration Engineering during 2013. It is intended to understand the status of current research in the areas of heating, cooling, ventilation, sanitation, and indoor environments of buildings and plant facilities. Conclusions are as follows. (1) The research works on the thermal and fluid engineering have been reviewed as groups of fluid machinery, pipes and relative parts including orifices, dampers and ducts, fuel cells and power plants, cooling and air-conditioning, heat and mass transfer, two phase flow, and the flow around buildings and structures. Research issues dealing with home appliances, flows around buildings, nuclear power plant, and manufacturing processes are newly added in thermal and fluid engineering research area. (2) Research works on heat transfer area have been reviewed in the categories of heat transfer characteristics, pool boiling and condensing heat transfer and industrial heat exchangers. Researches on heat transfer characteristics included the results for general analytical model for desiccant wheels, the effects of water absorption on the thermal conductivity of insulation materials, thermal properties of Octadecane/xGnP shape-stabilized phase change materials and $CO_2$ and $CO_2$-Hydrate mixture, effect of ground source heat pump system, the heat flux meter location for the performance test of a refrigerator vacuum insulation panel, a parallel flow evaporator for a heat pump dryer, the condensation risk assessment of vacuum multi-layer glass and triple glass, optimization of a forced convection type PCM refrigeration module, surface temperature sensor using fluorescent nanoporous thin film. In the area of pool boiling and condensing heat transfer, researches on ammonia inside horizontal smooth small tube, R1234yf on various enhanced surfaces, HFC32/HFC152a on a plain surface, spray cooling up to critical heat flux on a low-fin enhanced surface were actively carried out. In the area of industrial heat exchangers, researches on a fin tube type adsorber, the mass-transfer kinetics of a fin-tube-type adsorption bed, fin-and-tube heat exchangers having sine wave fins and oval tubes, louvered fin heat exchanger were performed. (3) In the field of refrigeration, studies are categorized into three groups namely refrigeration cycle, refrigerant and modeling and control. In the category of refrigeration cycle, studies were focused on the enhancement or optimization of experimental or commercial systems including a R410a VRF(Various Refrigerant Flow) heat pump, a R134a 2-stage screw heat pump and a R134a double-heat source automotive air-conditioner system. In the category of refrigerant, studies were carried out for the application of alternative refrigerants or refrigeration technologies including $CO_2$ water heaters, a R1234yf automotive air-conditioner, a R436b water cooler and a thermoelectric refrigerator. In the category of modeling and control, theoretical and experimental studies were carried out to predict the performance of various thermal and control systems including the long-term energy analysis of a geo-thermal heat pump system coupled to cast-in-place energy piles, the dynamic simulation of a water heater-coupled hybrid heat pump and the numerical simulation of an integral optimum regulating controller for a system heat pump. (4) In building mechanical system research fields, twenty one studies were conducted to achieve effective design of the mechanical systems, and also to maximize the energy efficiency of buildings. The topics of the studies included heating and cooling, HVAC system, ventilation, and renewable energies in the buildings. Proposed designs, performance tests using numerical methods and experiments provide useful information and key data which can improve the energy efficiency of the buildings. (5) The field of architectural environment is mostly focused on indoor environment and building energy. The main researches of indoor environment are related to infiltration, ventilation, leak flow and airtightness performance in residential building. The subjects of building energy are worked on energy saving, operation method and optimum operation of building energy systems. The remained studies are related to the special facility such as cleanroom, internet data center and biosafety laboratory. water supply and drain system, defining standard input variables of BIM (Building Information Modeling) for facility management system, estimating capability and providing operation guidelines of subway station as shelter for refuge and evaluation of pollutant emissions from furniture-like products.

Characteristics of Spray Deposit Pattern and Flow Rate in the Air-Center Nozzle System (Air-center nozzle의 분무살포도(噴霧撒布度)와 분무량(噴霧量)의 특성(特性))

  • Lee, Sang Woo;Hur, Yun Kun
    • Korean Journal of Agricultural Science
    • /
    • v.7 no.2
    • /
    • pp.156-168
    • /
    • 1980
  • The air-center nozzles, being specially designed to supply air into the central part of water stream at seven levels of air volume, were tested for spray deposit pattern and flow-rate at each of the twelve pressure levels ranging from $0.35kg/cm^2$ (5 psi) to $6.33kg/cm^2$ (90 psi) in comparison with those of standard nozzles. The air-center nozzles produced comparatively more stable spray deposit patterns than the standard nozzles. The spray deposit patterns of the air-center nozzle were concentrated gradually in the central region with increase of air volume as a component of spray mixture. The degree of concentration of spray deposit on the central region from the air-center nozzle was higher than that of the standard nozzle, which suggested the possibility of obtaining farther travel distance spraying system at a given performance level. The flow rate of the air-center nozzle was not as much as that of the standard nozzle due to the air within certain limits. The rate of decrease of water flow became smaller with an increase in operating pressure although it changed rapidly in the beginning stage, ranging up to two or three percent of the air flow rate due to the compressive properties of air.

  • PDF