• Title/Summary/Keyword: Water management treatment system

Search Result 324, Processing Time 0.024 seconds

Full-scale Soil Washing and Non-discharged Washing Water Treatment Process of Soil Contaminated With Petroleum Hydrocarbon (현장규모의 유류오염 토양세척 및 무방류 세척 유출수 처리 공정)

  • Seo, Yong-Sik;Choi, Sang-Il;Kim, Jong-Min;Kim, Bo-Kyung;Kim, Sung-Gyoo;Park, Sang-Hean;Ju, Weon-Ha
    • Journal of Soil and Groundwater Environment
    • /
    • v.14 no.1
    • /
    • pp.61-67
    • /
    • 2009
  • A non-discharged system of sequentially physico-chemical water treatment was used to treat the contaminated water produced from washing system of soils according to full-scale soil washing. After washing the TPH contaminated soils, the remaining concentrations of COD$_{Mn}$, SS, and n-hexane were analyzed for each compartment to estimate the treatment efficiencies of non-discharged system. Three times of sampling events were conducted for 4 different compartments (sediment tank, flocculation tank, oil/water separator, and process-water tank). In addition, soil washing efficiencies and concentrations of each parameter (COD$_{Mn}$, SS, and n-hexane) for process-water tank were analyzed for about 8 months. As results, the average efficiency of soil washing was high to have 95.9%, regardless of the condition of TPH contamination level for soils, as well as the concentrations of COD$_{Mn}$, SS, and n-hexane in the process-water tank were below the regulation limits of the Water Environmental Conserveation Act. Accordingly, the full-scale washing treatment system in this study could make the washing water 100% recycled which lead the system to be environmentally-friendly and economical.

A Feasibility Review for an Uneven Baseline Basis Minimal Ballast Ship

  • Kang, Hee Jin;Kim, Kwang-Soo;Choi, Jin;Lee, Yeong-Yeon;Ahn, Haeseong;Yim, Geun-Tae
    • Journal of Ocean Engineering and Technology
    • /
    • v.34 no.1
    • /
    • pp.1-12
    • /
    • 2020
  • Although there are many kinds of advanced ballast water management systems, pioneering studies for ballast-water free ship and minimal ballast water ship concepts are in progress. In this study, the existing alternatives of ballast water are reviewed and a new design concept is studied on the basis of the existing bulk carrier hull form. To develop a new design alternative which has minimal ballast for ballast water discharge free operation, the new concept should have technical feasibilities that are related to the role of the ballast water, berth access, loading constraints, etc. For this purpose, a simplified systems engineering basis design approach is adopted using a business model as the system analysis and control tool. To check the performance feasibility of the new concept, ship resistance performance is reviewed based on a model scale ship resistance performance analysis.

Study in the integrated watershade management for conservation of water resources (II) - Water quality modeling and simulation of Oship stream - (수자원 보전을 위한 유역통합관리 방안에 관한 연구(II) - 오십천 수계의 수질모델링 및 수질 예측 -)

  • 허인량;정의호;권재혁
    • Journal of Environmental Health Sciences
    • /
    • v.28 no.2
    • /
    • pp.61-69
    • /
    • 2002
  • Oship stream is located nearby south eastern coasts. This study was performed to find out waters quality modeling and then to predict water quality of Oship stream. Based on survey data, BOD, T-N, T-P calibration and verification result were in good agreement with measured value within mean coefficient variance(MSE) value, which were 13.9%, 9.0%, 26.5% and 19.5%, 12.0%, 16.5%, respectively. Sectional water quality predictions of the main stream of Oship stream are executed on the basis of the following cases 1) with sewage treatment of Dogye-eup 2) reduction of mine wastewater treatment of 80% in th basin. As a result, BOD, T-P improvement rates at down stream of Oship stream, case 1) were appeared 12.2%, 22.2%, case 2) maximum sulfate ion and conductivity reduction removal rate of Oship stream were 58%, 68%. The main pollution sources of Oship-stream were almost domestic wastewater and mine wastewater discharged from Dogye-eup which located in uppers stream. The large effects will appear after the construction of Dogye sewage water treatment plant which remove the organic matter and nutrients in these sewage water. The waste water from mine can not easily to treat for characteristics of effluence and economic problems. However, to achieve the goal of water quality in Oship-stream water system, treatments of those are necessary.

Performance Characteristics and Improvement Suggestion of Individual Sewage Treatment in Kyangan Watershed (경안천 유역 소규모 오수처리시설의 처리특성 및 효율개선방안)

  • Jang, Young-ho;Kim, Keug Tae;Jahng, Deok-Jin
    • Journal of Korean Society on Water Environment
    • /
    • v.26 no.5
    • /
    • pp.816-821
    • /
    • 2010
  • It has been achieved 109.1 kg/d of BOD reduction that is equivalent to the amount of BOD loading discharged from 21,880 persons and dramatic decrease of the fallout ratio against water quality of effluent, from 42% to 9%, through technical support on ISTPs to be applied by the ISMSGA at the upper area of Geongan river in Yong-In city. It was clearly revealed that the most efficient configuration for ISTP was a series of anaerobic tank, equalization basin, aerobic tank, sedimentation tank, and then effluent tank. Also, the major causes on the fallout ratio of ISTP resulted in the lack of management (67.5%) and imperfect facilities (32.5%). Then, when compared the quantity of water supply with the design capacity of ISTP, the design capacity was estimated as 1.8 or 2.4 folds larger than the real quantity of water supply so that it is essential to punctually consider the key factors such as an estimation methods, the specificity of commission operator and construction by high systematic technologies to improve the water quality for the future.

Installation and Shipboard Tests of the Ballast Water Treatment System Electro-Cleen (Electro-Cleen 선박평형수 처리장치의 실선 설치 및 선상시험)

  • Kim, Eun-Chan;Cho, Jin-Suk;Park, Yong-Seok;Lee, Jong-Wook
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.12 no.3
    • /
    • pp.209-216
    • /
    • 2009
  • IMO has established International Convention for the Control and Management of Ships' Ballast Water and Sediment 2004 in February 2004 in order to prevent transfer of aquatic organisms through ballast water. According to the Convention, Each countries are preparing ratification and legislation process and encouraging the development of treatment system to satisfy the performance standard in the Convention. This Electro-$Cleen^{TM}$ treatment system was granted IMO basic approval in March 2006, and final approval in October 2008. The Type Approval Certificate was issued in December 2008 by the Government of Republic of Korea. This paper considers the matter of principle mechanism, overview of the system, installation on shipboard and shipboard test results for the Electro-$Cleen^{TM}$. Shipboard tests with the 8300 GT M/V Yokohama and 27,000 DWT M/V Greenwing have already been conducted. These tests confirmed that the Electro-$Cleen^{TM}$ system satisfies all of the IMO standards and is suitable for installation in new and existing ships.

  • PDF

Consideration on the Ballast Water Treatment System Technology and its Development Strategies (IMO 선박평형수 처리장치 기술과 발전 방향에 대한 고찰)

  • Kim, Eun-Chan
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.15 no.4
    • /
    • pp.349-356
    • /
    • 2012
  • For smooth implementation of the IMO Ballast Water Management Convention that is to come into effect in the near future, IMO and Member States are working on the development of various technologies and establishment of legislative action. Ballast water treatment systems are essential, yet difficult technologies, as they need not only to treat living organisms, but also define whether they are viable or not, count the number of viable organisms, and present quantitative results of the concentration of active substances. Despite the fact that the Convention is looming in the near future, the issues mentioned above obstruct the setup of consensual technologies for performance reliability of the treatment system and analysis method of efficacy test results. This paper considers the unsolved issues of the ballast water treatment technologies, and presents guidelines to solve these issues.

USN-based Water Treatment Plant Facilities Data Management Techniques and Reliability (USN 기반 수직형 정수처리시설 데이터 최적관리 및 신뢰성 검증연구)

  • Jang, Sang-Bok;Shin, Gang-Wook;Hong, Sung-Taek;Lee, An-Kyu;Park, Hye-Mi;Chun, Myung-Geun
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.17 no.11
    • /
    • pp.2736-2744
    • /
    • 2013
  • In this paper, we present a Smart Water Treatment Plant using Zigbee USN devices and a real-time monitoring system in K-water Flow Meter Calibration Center Building. For verification, the data of vertical type WTP such as flow rate, pressure, water level and water temperature are obtained by the Zigbee USN devices, operating in 2.45 GHz band, and be wirelessly surveilled by the real-time monitoring system. The received data from the sensor is transmitted to the data processing device, and then the processed data can be monitored on a smart phone. Consequently, the pilot plant based on the low-cost and high-efficiency USN has been developed with the performance analysis for the communication network and remote monitoring system on mobile devices.

Removal Characteristics of Natural Organic Matter and Taste and Odor by Advanced Water Treatment Process around the Han River Water Supply System (한강수계 고도정수처리 공정에서의 유기물과 맛·냄새의 제거특성)

  • Jae-Lim Lim;Lee, Kyung-Hyuk;Kim, Seong-Su;Chae, Seon-Ha
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.21 no.1
    • /
    • pp.13-25
    • /
    • 2007
  • The water treatment plants in Seoul Metropolitan Area, which are under Korea Water Resources Corporation(KOWACO)'s management, take water from Paldang Reservoir in Han River System for drinking water supply. There are taste and odor (T&O) problems in the finished water because the conventional treatment processes do not effectively remove the T&O compounds. As part of countermeasures for taste and odor control, KOWACO is planning to introduce advanced water treatment process such as ozone and GAC in near future. This study evaluated the removal characteristics of T&O and dissolved organic matter (DOM) to find design and operation parameters of advanced water treatment processes in a pilot-scale treatment plant. The GAC adsorption capacity for DOC in the two GAC system (GAC and $O_3$-GAC) at an EBCT of 14min was mostly exhausted after 9months. The differency of the removal efficiency of DOC between $O_3$-GAC and GAC increased with increasing operation time because the bioactivity in $O_3$-GAC process was enhanced by post-ozone process. Removal by conventional treatment was unable to reach the target TON(threshold odor number) of 3 but GAC systems at an EBCT(empty bed contact time) of 14 min were able to archive the target with few exception. During the high T&O episodes, PAC as a pretreatment together with GAC could be useful option for T&O control. However, substantial TON removal continued for more than two year (> 90,000 bed volumes). At the spiking of less concentration 26 to 61 ng/L in the influent of GAC systems, GAC absorber and $O_3$-GAC processes could meet the treatment target. The better spike control after 12 and 19 months of operation compared to that after 7 months of operation is a strong indication of biological control. The results presented in this study had shown that $O_3$-GAC process was found to be more effective for T&O control than GAC process. And the main removal mechanism in GAC systems were adsorption capacity and biodegradation.

An Assessment on Efficiency of MBAS Removal in Urban Stream Maintenance Water by Using Sand Filtration (모래여과를 이용한 도시하천유지용수의 MBAS 제거 효율 평가)

  • Kim, hong bae;Ahn, kyung soo
    • Journal of Wetlands Research
    • /
    • v.8 no.2
    • /
    • pp.45-51
    • /
    • 2006
  • Biological enhanced treatment and send filtration are established being operated to remove nutrients and MBAS(Methylene Blue Activate Substance) in the most of Waste Water Treatment Plant(WWTP) in Korea. However, untreated synthetic detergents and nutrients which directly run into the water system present an unpleasant view because of the foam, taste and odor generating filamentous periphytic algae and interrupting self-purification in the stream. Therefore, this research was enforced to know the MBAS removal efficiency of the sand filtration about G WWTP which reuses effluent as urban stream management water. As a result, the maximum removal efficiency using sand filtration was 63% after 24 hours and particularly 30% after 2 or 4 hours which turned out to be not that effective. In conclusion, It is recognized that other methods of MBAS removal and a research will be needed which reuse effluent as urban stream management water from now on. Because the MBAS removal with sand filtration is insufficient with economical efficiency from the fact that it needs long hours for a sand filtration treatment and the removal efficiency was almost below the expectation.

  • PDF

A Development Study on High Quality Drinking Water Production by the Biological Activated Carbon/immersed Membrane Filtration System

  • Inoue, Shiro;Iwai, Tosinori;Isse, Masaaki;Terui, Taturo
    • Proceedings of the Membrane Society of Korea Conference
    • /
    • 2001.07a
    • /
    • pp.155-162
    • /
    • 2001
  • Advanced drinking water production systems, which not only good quality product water, but also provide easy management and mainenance of facilities, and operate on a smaller site area, have been expected to be developed for some time. We are going ahead with a program to deveop an advanced drinking water production system, using immersed membrane filtration combined with biological activated carbon, to meet the need described above. The demonstration plant tests been conducted with surface water from the Yodo-river since Dec. 1998 to measure treatment performance, reliability, and controllability of the system. The quality of product water has consistently remained at a very high level for about 2 years under controlled conditions. Results showed that the re-circulation granular biological activated carbon could suppress the increase of membrane pressure difference and promote a reduction of dissolved organic matter. (This work has been conducted along the ACT21 Programs.)

  • PDF