• 제목/요약/키워드: Water management treatment system

검색결과 324건 처리시간 0.033초

하천수 및 정수공정에서의 비소관리를 위한 대체인자 개발 (Development of Alternative Indicator for Arsenic Management in River Basin and Drinking Water Treatment)

  • 강미아;김광태
    • 한국물환경학회지
    • /
    • 제21권6호
    • /
    • pp.659-663
    • /
    • 2005
  • Many studies have been conducted to develop new technologies for arsenic removal and to reveal the levels of arsenic and other chemicals in rivers, lakes and ground waters. However, there are few studies dealing with such compounds in the total water system of the city, and the way of management of these compounds in the water system. Because the occurrence of these hazardous compounds, which are geological origins, is almost impossible to control, it is very important to manage these compounds in the water system. In this research, it was revealed that the risk of arsenic in the water treatment system of S city in Japan. As a results, the parameters such as Q in river and E260 in drinking water treatment plant is proposed as a new indicator with simple and rapid method for controling arsenic level.

매립지내 환경에너지단지의 무방류 시스템 구축방안 (Construction Method of Zero Discharge System for Environmental Energy Complex in Landfill)

  • 천승규
    • 상하수도학회지
    • /
    • 제27권5호
    • /
    • pp.581-590
    • /
    • 2013
  • A research was performed for zero discharge system of waste water which is produced from energy recovery process of waste and biomass. Leachate and all kinds of waste water should be separated and integrated into three categories in addition to converting existing leachate treatment facility into waste water treatment facility as well as introducing a management system of reverse osmosis membrane facility and bioreactor landfill. Following these conditions to better water treatment process, it was likely to produce over 3,000 tons of low-grade recycling water and 2,000 tons of high-grade recycling water per day when zero discharge system of waste water is applied starting from 2016. Economical efficiency was also surveyed in total treatment fee. Present system costs 18,129 million won per year, and suggested zero discharge system would cost 15,789 million won per year.

하천 수질관리 시스템에서 최적화를 위한 유전알고리즘의 개발 (Development of a Genetic Algorithm for the optimization in River Water Quality Management System)

  • 성기석;조재현
    • 한국경영과학회:학술대회논문집
    • /
    • 한국경영과학회 2001년도 추계학술대회 논문집
    • /
    • pp.203-206
    • /
    • 2001
  • Finding the optimal solution in the river water quality management system is very hard with the non-linearity of the water quality model. Many suggested methods for that using the linear programming, non-linear programming and dynamic programming, are failed to give an optimal solution of sufficient accuracy and satisfaction. We studied a method to find a solution optimizing the river water quality management in the aspect of the efficiency and the cost of the waste water treatment facilities satisfying the water Quality goals. In the suggested method, we use the QUAL2E water quality model and the genetic algorithm. A brief result of the project to optimize the water quality management in the Youngsan river is presented.

  • PDF

워터젯 수압분사와 화염버너에 의한 석판재 표면처리의 품질특성 비교연구 (Comparison Study on Quality Characteristics of Surface Treatment of Stone Board Materials by Water-jet System and Flame-burner)

  • 강지호;장명환
    • 대한안전경영과학회지
    • /
    • 제5권1호
    • /
    • pp.115-128
    • /
    • 2003
  • To comparison the surface treatment methods of stone board materials, the results of Dorry's abrasive test were 23.4 for water-jet system and 18.9 for flame-burner system. Therefore abrasive hardness, the stone board materials by the water-jet system was greater than one by flame-jet system. As a result of Shore's hardness test, the stone board materials by water-jet system was twice greater than one by flame-jet system. Authors carried out microscopic observation to survey a defection of the composition minerals for two methods, but all of the both methods have not founded a defection. Therefore, the stone board materials by water-jet system was greater durability than one by flame-jet for the surface treatment methods.

GIS를 이용한 하천수질관리 (An Application of GIS to Water Quality Management)

  • 양형재;이유원;김민
    • 환경영향평가
    • /
    • 제3권2호
    • /
    • pp.25-32
    • /
    • 1994
  • This study was carried out as the Anyang creek water quality management using Geographic Information System (GIS) is the purpose of this pilot project to apply a GIS to environmental management field. Analysis of water quality data has been investigated using GIS with modeling of water quality management for the Anyang creek. The results of this study are summarized as follows: 1. The concentration of Mercury in sediment was increased rapidly nearby A26(Nightsoil Treatment Plant) and maximum was showed at A18 (Imgok bridge). Cadmium was increased rapidly at A35(Chulsan bridge). 2. River water quality management using visible computer system as GIS is effective to make decision for water quality management plan and database of environmental factors should be completed before applying GIS. 3. When water pollution accident is occurred in the river water system, pollutant source can be traced and analysed systematically using GIS to manage pollutants discharged into the river water system.

  • PDF

의사결정지원기법을 이용한 농촌유역 수질관리모형의 개발 (Development of Water Quality Management Model for Rural Area Using Decision Support System)

  • 양영민;권순국
    • 한국농공학회:학술대회논문집
    • /
    • 한국농공학회 1999년도 Proceedings of the 1999 Annual Conference The Korean Society of Agricutural Engineers
    • /
    • pp.783-788
    • /
    • 1999
  • In this study, a decision support system (DSS) was developed to calculate optimal wastetreatment cost, treatment level and treatment quantity of various pollutants for applying for in rural basin. The DSS includes a gegraphic informatino system (GIS), relational database system (RDBS), water quality models(Loading function , WASP5), watershed pollution load calculation module(SPLC), optimal water quality management plan to satisfy the water quality regulations. The system can be modified by user to trace the optimal condition for decision. The effort was conducted to apply the developed DSS to select the for optimal water quality management plan small rural basin called Kwanri Stream.

  • PDF

물 자원 생산을 위한 Coal Seam Gas Water Management Study의 평가 및 분석 2. 처리기술 예측 및 병합 시스템 설계 (Assessment and Analysis of Coal Seam Gas Water Management Study for Water Resource Production 2. Prediction of Treatment Technology and Design of Co-treatment System)

  • 신춘환
    • 한국환경과학회지
    • /
    • 제24권12호
    • /
    • pp.1629-1637
    • /
    • 2015
  • To develop various usable water from coal seam gas (CSG) water that needs to be pumped out from coal seams for methane gas production, a feasibility study was carried out, evaluating and analysing a recent report (Coal Seam Gas Water Management Policy 2012) from Queensland State Government in Australia to suggest potential CSG water treatment options for fit-for-purpose usable water production. As CSG water contains intrinsically high salinity-driven total dissolved solid (TDS), bicarbonate, aliphatic carbon, $Ca^{+2}$, $Mg^{+2}$ and so on, it was found that appropriate treatment technologies are required to reduce the hardness below 60 mg/L as $CaCO_3$ by setting the reduction rates of $Ca^{+2}$, $Mg^{+2}$ and Na+ concentrations, as well as TDS reduction. Also, Along with fiber filtration and membrane separation, an oxidation degradation process was found to be required. Along with salinity reduction, as CSG water contains organic compounds (TOC: 248 mg/L, $C_6-C_9$: <20 mg/L and $C_{10}-C_{36}$: <60 mg/L), compounds with relatively high molecular weights ($C_{10}-C_{36}$) need to be treated first. Therefore, this study suggests a combined system design with filtration (Reverse osmosis) and oxidation reduction (electrolysis) technologies, offering proper operating conditions to produce fit-for-purpose usable water from CSG water.

정수시설 자산관리 LoS분석 벤치마크지수 개발 (Development of Benchmark Index of LoS for Asset Management of Water Treatment Facilities)

  • 남영욱;현인환;이철성;천민규;김민철;김두일
    • 상하수도학회지
    • /
    • 제29권6호
    • /
    • pp.667-683
    • /
    • 2015
  • Since aged water treatment facilities could threaten the sustainable water supply, asset management system has been adopted for their systematic management. Level of Service(LoS) is one of critical components of asset management and could be quantified through benchmark index(BMI). Water supplier could estimate consumer's satisfaction and their performance through BMI to improve the LoS. We developed BMI for water treatment facilities from customer's satisfaction survey. BMI, represented with the Total Service Score(TSS), was assessed with water quality, water pressure, taste and odor, water rate, and service quality with weighing factors. BMI could, further, be used to assist the analysis of the life cycle cost to increase the unit of LoS.

수처리시설용 광대역 통합망 연계형 실시간 계측 관리 시스템 UI개발 (Real-time measurement management system UI development linked the Water treatment facilities Broadband Convergence Network)

  • 양승연;김진태;오환진;이민우
    • 한국위성정보통신학회논문지
    • /
    • 제10권4호
    • /
    • pp.83-86
    • /
    • 2015
  • 본 논문에서는 수처리 시설용 광대역 통합망 연계 실시간 계측관리 시스템 UI 개발을 제안한다. 수처리시설용 광대역 통합망을 통해 서버로 수신된 센서 및 영상 데이터를 Web과 연동하기 위한 프로그램을 개발하며, 이와 별도로 독립적으로 운영이 가능한 UI를 개발한다. 전송된 센서 및 영상데이터를 원격 모니터링 하기 위한 웹 서버를 구축하며 센서 데이터, 영상 데이터를 Web기반의 UI를 통해 감시 및 제어가 가능하도록 개발하였다. 제안하는 수처리 시설용 광대역 통합망 연계형 실시간 계측관리 시스템을 통하여 센서를 통한 측정시간, 농도, 수심 계면 등의 현재 상태를 파악할 수 있으며 영상 모니터링을 통하여 실시간으로 수처리 시설의 정상적인 동작여부와 보안 및 화재 등의 인명피해 여부를 확인 할 수 있다. 뿐만 아니라 실시간 계측 관리 시스템을 실시간으로 모니터링 할 수 있는 UI 개발로 인해 실시간으로 정보를 한눈에 볼 수 있다.

상수원 관망 부식 제어를 위한 부식성 수질 관리: 북미지역 관리 사례 및 국외 현황 (The Regulations and Guidelines for Management of Corrosive Water and Pipe Corrosion in Drinking Water Distribution System in North America)

  • 김민희;현승훈;이원석
    • 한국물환경학회지
    • /
    • 제33권3호
    • /
    • pp.359-369
    • /
    • 2017
  • Water distribution systems supply drinking water to consumers' taps. Internal corrosion of metallic pipe used in drinking water distribution systems has reduced water quality and led to increased levels of toxic heavy metals such as lead, copper and nickel. These problems have been experienced to varying degrees by water utilities in many countries. North America has successfully managed and controlled pipe corrosion and corrosive water in water distribution system based on various policies, regulations and rules. Practical and engineering guidelines for evaluation of pipe corrosion and determination of treatment options are also provided to assist drinking water supplies. In addition, the corrosion mechanism in water distribution systems, such as the complex effects of physical and chemical parameters on the corrosion pipes has been improved to accurately predict corrosion rates of metallic pipes in actual water distribution systems. This paper reviews various regulations, policy statement, and treatment produces on controlling corrosion in drinking water distribution systems in US and Canada and then offers suggestion for management of corrosive water and pipe corrosion in drinking water distribution system in Korea.