• Title/Summary/Keyword: Water loss

Search Result 3,663, Processing Time 0.037 seconds

Distribution of the Organic Contents in Reservoir Sediment (호소 퇴적물의 유기물 분포)

  • Hwang, Jong Yeon;Han, Eui Jung;Yu, Soon Ju;Yoon, Young Sam;Cheon, Se Eug;Kim, Tae Keun
    • Journal of Environmental Impact Assessment
    • /
    • v.8 no.2
    • /
    • pp.95-107
    • /
    • 1999
  • The organic contents of reservoir sediment can offer a good indicator to events in history of lake life. Reservoir sediment have many information of the past and future fingerprint about development direction of life cycle in biological animals. So, in this study we made an effort to know the distribution of organic contents in Daecheong reservoir sediment. Items for this investigations are such as follows: Loss on ignition, COD, Organic carbon, TN, TP, heavy metal contents, Loss on ignitions were determined in 6.44~15.91% and COD were determined in 1.606~6.859%, organic carbon in 1,077~3.743%. Contents of TP and TN were in the range of 0.083~0.757%, and 0.645~0.926%, respectively.

  • PDF

A Study of Design factors for Increasing Energy Production in Small Hydro power with Using Long Pipe (장대관로를 이용한 소수력 발전량 향상을 위한 설계요소에 관한 연구)

  • Kim, Hyun-Han;Kim, Kwang-Ho
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.63 no.8
    • /
    • pp.1134-1139
    • /
    • 2014
  • Recently the need for renewable energy development is expanding due to the global climate change, the environmental issues and the limited fossil energy resources. Dependence of energy on overseas is high in Korea. To resolve the environmental problems and to improve the energy independence rate, the development of renewable energy is more required. The small hydro power, one of the renewable energy resources, has been developing and operating from a long time ago. If we are new developing a small hydro power with the use existing dams and reservoirs, we will design the length of inlet pipe and the diameter suitable for it. However, in case of using the existing water supply pipe which had been designed suitable for water service, the designer has to review and check that the pipe is suitable for operating a generator. In this paper, the design of small hydro power using the existing long pipe of water supply, we suggest the optimum way to reduce the water hammer in pipe which causes the unsteady flow during the load-shutdown of generator, the generator operation plan for the stable supply of water and the design factor of determining the generator capacity through the analysis between discharge and head-loss.

Application of Micro Cross-Flow Turbine to Water Supply System (마이크로 관류수차의 상수도 관로시스템 적용에 관한 연구)

  • Choi Young-Do;Kurokawa Junichi
    • The KSFM Journal of Fluid Machinery
    • /
    • v.9 no.3 s.36
    • /
    • pp.36-43
    • /
    • 2006
  • Recently, micro hydropower and it's useful utilization are taking a growing interest as a countermeasure of global worming by carbon dioxide and exhaustion of fossil fuel. The purpose of this study is to investigate the possibility of extracting micro hydropower wasted by a valve in water supply system using micro cross-flow hydraulic turbine. In order to fulfill the functions of controlling flow rate and pressure in substitute for the valve, air and water are supplied into an air suction hole which is installed on the side wall of micro cross-flow hydraulic turbine. The results show that in case of supplying a lot of air into the air suction hole, about 50% of flow rate and relatively high value of loss coefficient are controlled by the turbine. Moreover, including high possibility of applying the micro cross-flow turbine to water supply system, extended application of the turbine to the water discharge system of drainage and irrigation canal.

Comparison of the Characteristics of Reservoir and Stream Sediments in Kum River basin (금강권역의 호소 및 하천 퇴적물 특성 비교)

  • Hwang, Jong-Yeon;Han, Eui-Jung;Kim, Tae-Keun;Yu, Soon-Ju;Yoon, Young-Sam;Chung, Yong-Soon
    • Journal of Environmental Impact Assessment
    • /
    • v.7 no.2
    • /
    • pp.135-143
    • /
    • 1998
  • In order to study the general characteristics of reservoir and stream sediments, various analysis tests were conducted. Water contents and ignition loss were measured to know the primary sediment characteristics. The COD, total phosphorus and nitrogen were contained for the determination of organic substance content. For the purpose of establishing the contamination degree of heavy metals, some heavy metal contents were investigated. In heavy metal contents, reservoir sediments showed somewhat higer value than stream sediments. As a result, the reservoir sediment content of all analysis items were higher than stream sediment.

  • PDF

Experimental Study on the Interference of Water Vapor on the Chemical Ionization of OH by Sulfur Hexafluoride Ion

  • Park, Jong-Ho
    • Mass Spectrometry Letters
    • /
    • v.5 no.4
    • /
    • pp.120-123
    • /
    • 2014
  • The interference of water vapor on the chemical ionization (CI) of hydroxyl radicals (OH) by sulfur hexafluoride ion ($SF_6{^-}$) was investigated using a flow tube system coupled to a high-pressure CI mass spectrometer. Water vapor, which is required to study heterogeneous reactions of OH under real tropospheric conditions, transforms the reagent ion $SF_6{^-}$ into $SF_4O^-$ and $F^-(HF)_n$, resulting in a substantial loss in CI sensitivity. Therefore, under humid conditions, peaks corresponding to OH are drastically diminished, while those corresponding to OH-water complex ions ($[OH(H_2O)_n]^-$) are enhanced. $[OH(H_2O)_3]^-$ was observed as the major OH species. The obsercation of $[OH(H_2O)_n]^-$ by isolating humid conditions to the CI region and preliminary ab initio calculations suggested that $[OH(H_2O)_n]^-$ ions were produced from reactions between OH ions ($OH^-$) and water molecules. An additional helium buffer flow introduced into the CI region reduced loss of the reagent ion and resulted in a partial recovery of OH peak intensities under humid conditions.

Computational Fluid Dynamics Study on Performance Variation of PEMFC with Serpentine Flow Fields According to Humidity Condition (가습조건이 사형유로를 채택한 고분자 전해질 연료전지의 성능에 미치는 영향에 대한 전산유체역학 해석 연구)

  • Oh, Gyu-Hwan;Lee, Kyu-Jin;Nam, Jin-Hyun;Kim, Charn-Jung
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.33 no.8
    • /
    • pp.604-612
    • /
    • 2009
  • Water management has been recognized as a crucial factor for achieving better performance and stability in polymer electrolyte membrane fuel cells (PEMFCs). Proper water management should provide favorable water conditions, including the local humidity, membrane water content, and liquid water saturation in PEMFCs, thereby leading to more uniform electrochemical reaction and current generation. In this study, computational fluid dynamics (CFD) simulation was conducted to investigate the effects of the cathode relative humidity (RH) on the performance of a 3 by $3\;cm^2$ PEMFC with serpentine flow fields. The CFD results showed that the best performance of the PEMFC was obtained for the cathode RH of 80%, but the performance variation was small for the cathode RH range of $60{\sim}100%$. However, the loss of the PEMFC performance was significant when the cathode RH was reduced below 40%. The reason for such performance variation was investigated through the detailed inspection of ohmic loss, activation and concentration overpotential, and water and current distributions.

Slump Loss of High Strength Concrete Containing Mineral Admixture and Gypsum (광물질 혼화재 및 석고를 사용한 고강도 콘크리트의 슬럼프 손실)

  • 김기형;최재진
    • Journal of the Korean Society of Safety
    • /
    • v.12 no.1
    • /
    • pp.101-107
    • /
    • 1997
  • High strength concrete(HSC) using high range water reducing admixture (HRWR) has the defect which severe slump loss occurs according to elapsed time. For using HSC without any trouble, special caution and countermeasure against this problem are necessary. In this study, for minimizing the slump loss of HSC, mineral admixture( flyash, ground granulated blast furnace slag ) and gypsum were used experimentally. Flyash and ground granulated blast furnace slag are effective in reducing the slump loss of HSC. Especially, the slump loss of HSC containing mineral admixture and gypsum Is minimized by the aggregation inhibiting action of gypsum. Cement substituted with flyash 30% or ground granulated blast furnace slag 50% by weight are very effective in minimizing the slump loss.

  • PDF

Comparison of Water Retention and Loss of Chicken Carcasses by Different Water Chilling Condition (침지냉각 조건에 따른 닭 도체의 수분 흡수 및 감량 비교)

  • Lee, Jae Cheong;Kim, Byeong-Ki;Jun, Jin An;Yim, Chan Hyok;Kim, Hyosun;Lee, Kyung-Woo
    • Korean Journal of Poultry Science
    • /
    • v.41 no.3
    • /
    • pp.159-164
    • /
    • 2014
  • This study was conducted to investigate whether water chilling had effect on water retention, freshness or internal temperature of chicken carcasses during chilling or storage in two different chicken processing plants (designated as A and B). A total of 240 carcasses from chicken processing plants (n = 120 per chicken processing plant) was randomly sampled and evaluated the effect of water chilling on carcass characteristics (i.e., water retention, water loss or freshness during chilling or storage). Torrymeter value was used as an indicator of freshness in chicken carcasses. Water chilling did not affect carcass water retention between the processing plants. However, chicken carcasses processing in B plant exhibited significantly higher freshness (p<0.05) compared with those in A plant. This difference in freshness was mainly due to the longer transit time through the water chiller in A versus B plants. Water loss of carcasses during storage was not different between plants. It was found that carcass freshness can be affected by water chilling time as manifested in this study. Further study is warranted to see whether freshness or microbiological status of chicken carcasses may be affected depending on the chilling methods, i.e., air or water chilling.

Effect of Carriers on Residue of Wetting Agent Containing Polyoxyethylene Octylphenyl Ether, Initial Wetting and Water Movement in Container Media (증량제의 종류가 Polyoxyethylene Octylphenyl Ether를 포함한 토양습윤제의 상토내 잔류성, 상토의 수분보유 및 이동에 미치는 영향)

  • Choi, Jong Myung;Min, Kyung Rae
    • Horticultural Science & Technology
    • /
    • v.18 no.6
    • /
    • pp.839-844
    • /
    • 2000
  • In developing of soil wetting agents using the mixture of polyoxyethylene octylphenyl ether [$C_8H_{17}O$ $(C_2H_4O)_{10}H$, POE] and polyoxyethylene+polypropyleneoxide tridecylether (1:1, w/w, CM-1), the effect of base carriers such as zeolite and vermiculite on changes of concentration of POE and on initial wetting of peat-vermiculite media were determined. The concentration of POE in the treatment of zeolite was higher than that of vermiculite. The treatments of POE+CM-1 with zeolite or vermiculite as carrier were effective in initial water retention of root media having about 510 mL of water per pot, where those of AquaGro and control had 490 mL and 400 mL of water per pot, respectively. In the evaporative water loss, the treatment of zeolite and AquaGro were faster than those of control and vermiculite. The treatment of AquaGro had faster water movement in root media than those of POE+CM-1 regardless of carriers and same trends were observed in the volume of water infiltrating into root media. Also, increasing the amount of POE+CM-1 resulted in increased water retention capacity, evaporative water loss, water movement in root media and amount of water infiltrating into root media.

  • PDF

A Study on the Estimation of Loss Rate of Dredged Fills (준설토의 유실률 평가에 관한 연구)

  • Kim, Hong-Taek;Kim, Seog-Yeol;Kang, In-Kyu;Park, Jae-Eock
    • Journal of the Korean GEO-environmental Society
    • /
    • v.1 no.1
    • /
    • pp.57-63
    • /
    • 2000
  • Volume change of the dredged soils is composed of loss amount of the soil particles flowing over an outflow weir with water and settlements due to both the self-weight consolidation in reclaimed layer and the desiccation at the surface of reclaimed layer. In order to estimate the amount of soil particles flowing over an outflow weir with water, the breakage theory and the results of hydrometer analyses. To verify a validity of the proposed procedure, evaluated loss ratio is compared with various estimates from the other existing methods.

  • PDF