• Title/Summary/Keyword: Water level of reservoir

Search Result 479, Processing Time 0.024 seconds

A Study on the Application of Total Pollution Load Management System for Water Quality Improvement in Agriculture Reservoir (농업용 호소의 수질개선을 위한 오염총량관리제의 적용에 관한 연구)

  • Oh, Dae-Min;Lee, Young-Shin
    • Journal of Environmental Health Sciences
    • /
    • v.35 no.5
    • /
    • pp.365-375
    • /
    • 2009
  • Agriculture reservoirs need a systematic approach that can control water purity and water improvement. The area under study, Bunam Lake exceeds the agricultural water standard level due to contamination from the upper stream. When the Taean Enterprise City was planned, the water quality improvement plan was applied to minimize the environmental change. However, in order to continuously maintain the water quality in the Bunam Lake, it was essential to apply the Total Pollution Load Management System (TPLMs). In order to achieve the targeted water quality in the Bunam Lake, standard flow rates and targeted water quality levels were applied to obtain the loading capacity which is as follows : BOD 1,891.2 kg/d, T-N 1,945.7 kg/d, T-P 131.7 kg/d. Also, the regional development load was calculated as, BOD 1,083.6 kg/d, T-N 942.2 kg/d, T-P 61.8 kg/d, which is required to be deceased :- by BOD 378.4 kg/d, T-N 198.9 kg/d, T-P 31.6 kg/d in order to safely achieve the targeted water quality in the Bunam Lake.

Basic Study on Monitoring System of Reservoir and Leeve Using Wireless Sensor Network (무선센서 네트워크 계측을 이용한 저수지 및 제방 계측시스템 구축에 관한 기초연구)

  • Yoo, Chanho;Kim, IkHoon;Lee, Seungjoo;Hwang, Jungsoon;Baek, Seungcheol
    • Journal of the Korean GEO-environmental Society
    • /
    • v.19 no.1
    • /
    • pp.25-30
    • /
    • 2018
  • Conventional monitoring method is used for evaluation of the reservoir and levee at the highest height sections. In recent years, automated measurement technology has been developed, and the measurement results are transmitted, collected and stored in real time into management office. Despite the development of real time monitoring technology, the measurement results are not used directly or indirectly with facility management at real time. Recently, as wireless sensor network measurement technology has been developed based on internet of things, this study proposed a real - time measurement and evaluation system based on wireless sensor network technology in the reservoir structure. As a result of the seepage analysis for the application, it was confirmed that the volumetric water content changes together with the change of the seepage line inside the embankment body according to the change of the water level of the embankment. In other words, the applicability of the measurement system with the volumetric water ratio set as the sensor node was verified.

Heavy Metal Contents in Tissues of Fishes in Andong and Imha Reservoirs (안동.임하호에 서식하는 수종 어류의 조직 내 중금속 함량)

  • Shin, Myung-Ja;Park, Young-Mi;Lee, Jong-Eun;Seo, Eul-Won
    • Journal of Life Science
    • /
    • v.20 no.9
    • /
    • pp.1378-1384
    • /
    • 2010
  • The present study aimed to investigate the effect of heavy metal contamination in the aquatic environment on the fishes (Opsariichthys bidens, Cyprinus carpio, Hemiculter eigenmanni and Culter brevicauda) inhabiting Andong and Imha reservoirs by comparing and analyzing the heavy metal contents accumulated in their tissues. Heavy metal contents were shown to be higher in the Andong reservoir than in the Imha reservoir. Accumulated heavy metals, Cr, Cu and Pb, were detected in tissues and bone tissues, but Cd was also found in the kidneys. Zn content was the highest among accumulated metals, whereas Cu content was the lowest in all tissues from the fishes in the Andong and Imha reservoirs. However, the amount of Cr in the tissues showed a twofold higher level in the Andong reservoir than that in Imha reservoir. The heavy metal contents of fish inhabiting the Andong reservoir were detected to be higher than those in the Imha reservoir. We also proposed that heavy metal contamination in water and its inhabiting fish is attributed to various heavy metals derived from water and sediments in the water environment of the Andong reservoir.

Analysis of Nutrient Load Balance in the Reservoir Irrigated Paddy Block (저수지 관개 광역 논의 영양물질 수지 분석)

  • Song, Jung-Hun;Kang, Moon-Seong;Song, Inhong;Hwang, Soon-Ho;Park, Jihoon;Jun, Sang-Min;Kim, Kye-Ung;Jang, Jeong-Ryeol
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.55 no.6
    • /
    • pp.167-175
    • /
    • 2013
  • The objective of this study was to investigate the nutrient load balance in the reservoir irrigated paddy block during growing seasons. Idong reservoir irrigation paddy block of 10.3 ha in size was selected to collect hydrologic and water quality data. Irrigation, canal flows, and paddy field drainage were measured using a water level gauge, while water samples were collected and analysed for water quality. The water balance analysis showed that 81 % and 75 % of total outflow were through paddy and irrigation canal drainage during 2011 and 2012, respectively. The water quality of paddy field drainage varied greatly depending on rice cultivation stage ranging from 0.05 to 24.55 mg/L and from 0.01 to 0.76 mg/L for T-N and T-P, correspondently. Paddy field drainage loads during May through June account for 64 % and 76 % in 2012 and 2013, while 82 % and 81 % for T-P in 2011 and 2012, respectively. The Pearson correlation analysis showed that rainfall was significantly correlated with nutrient loads during July through August due to runoff, and irrigation was related with nutrient loads of drainage during some period of July through September due to irrigation return flow. This study results showed characteristics of inflow and outflow nutrient loads from plentiful irrigated paddy block.

Analysis of Applicability by Filter Technique for Water Level Correction of Agricultural Canal (농업용 수로부의 수위 보정을 위한 필터기법별 적용성 분석)

  • Joo, Donghyuk;Na, Ra;Kim, Ha-Young;Choi, Gyu-hoon;Yun, Hyung Chang;Park, Sang-Bin;Yoo, Seung-Hwan
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.65 no.5
    • /
    • pp.51-68
    • /
    • 2023
  • Due to the recent integrated water management policy, it is important to identify a reliable supply amount for establishing an agricultural water supply plan. In order to identify the amount of agricultural water supply, it is essential to calculate the discharge by measuring the water level and flow velocity of reservoirs and canal agricultural water, and quality control to ensure reliability must be preceded. Unlike agricultural reservoirs, canal agricultural water are more sensitive to the surrounding environment and reservoir irrigation methods (continuous, intermittent irrigation, etc.), making it difficult to estimate general water level patterns and at the same time a lot of erroneous data. The Korea Rural Community Corporation is applying a filter technique as a quality control method capable of processing large quantities and real-time processing of canal agricultural water level data, and applicability evaluation is needed. In this study, the types of errors generated by the automatic water level measurement system were first determined. In addition, by using the manual quality control data, a technique with high applicability is derived by comparing and analyzing data calibrated with Gaussian, Savitzky-Golay, Hampel, and Median filter techniques, RMSE, and NSE, and the optimal parameters of the technique range was derived. As a result, the applicability of the Median filter was evaluated the highest, and the optimal parameters were derived in the range of 120min to 240min. Through the results of this study, it is judged that it can be used for quantitative evaluation to establish an agricultural water supply plan.

Producing synthetic lightweight aggregates by treating waste TFT-LCD glass powder and reservoir sediments

  • Tang, Chao-Wei
    • Computers and Concrete
    • /
    • v.13 no.3
    • /
    • pp.325-342
    • /
    • 2014
  • The use of lightweight aggregate (LWA) instead of ordinary aggregate may make lightweight aggregate concrete, which possesses many advantages such as lightweight, lower thermal conductivity, and better fire and seismic resistance. Recently the developments of LWA have been focused on using industrial wastes as raw materials to reduce the use of limited natural resources. In view of this, the intent of this study was to apply Taguchi optimization technique in determining process condition for producing synthetic LWA by incorporating waste thin film transition liquid crystal displays (TFT-LCD) glass powder with reservoir sediments. In the study the waste TFT-LCD glass cullet was used as an additive. It was incorporated with reservoir sediments to produce LWA. Taguchi method with an orthogonal array L16(45) and five controllable 4-level factors (i.e., cullet content, preheat temperature, preheat time, sintering temperature, and sintering time) was adopted. Then, in order to optimize the selected parameters, the analysis of variance method was used to explore the effects of the experimental factors on the performances (particle density, water absorption, bloating ratio, and loss of ignition) of the produced LWA. The results showed that it is possible to produce high performance LWA by incorporating waste TFT-LCD glass cullet with reservoir sediments. Moreover, Taguchi method is a promising approach for optimizing process condition of synthetic LWA using recycled glass cullet and reservoir sediments and it significantly reduces the number of tests.

Impacts on Residence Time and Water Quality of the Saemangeum Reservoir Caused by Inner Development (새만금 내부개발이 체류시간 및 수질변화에 미치는 영향)

  • Yoo, Sang-Cheol;Suh, Seung-Won;Lee, Hwa-Young
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.15 no.3
    • /
    • pp.186-197
    • /
    • 2012
  • In order to understand hydrodynamic and water quality changes on the Saemangeum reservoir in accordance to inner development plan, intensive numerical simulations using EFDC have been done. Due to inner dike construction and proposed dredging plans, stratification might occur and yield flow field change. It should be noticed that very conditional gate operation schedule adjusting target water elevation of -1.5 meter causes severe stratification and hence plays an important role in poor water qualities. By using random walk particle tracking residence simulations, it is found that hydrodynamic characteristics depends greatly on riverine inflow conditions. It is also inferred that the northern part of the Mangyeong reservoir behaves as a dead zone and acts as major reasoning of water quality deterioration owing to benthic flux from long-term residing settled sediment.

Environmental Changes and Embankment Addition of Reservoir Gonggeomji, Sangju City between Late Silla- and Early Goryeo dynasty (나말여초 상주 공검지의 환경 변화와 제방 증축)

  • Hwang, Sangill;Kim, Jeong-yun;Yoon, Soon-Ock
    • Journal of The Geomorphological Association of Korea
    • /
    • v.21 no.4
    • /
    • pp.165-180
    • /
    • 2014
  • Embankment of reservoir Gonggeomji in Sangju has been continuously added since the construction. After approximately 1220 yr BP of late Unified Silla dynasty when the embankment was firstly constructed, there were piled up four times with an interval of approximately 50 years until ca. 980 yr BP of late Goryeo dynasty. The first two times were relatively piled up high, while another two times were made slightly high. After addition of embankment, water level gradually became low and the quality also bad with increase of benthic- and epipitic diatoms than planktonic ones. Shoaling of reservoir was probably resulted from severe vegetation destructions on the small river basins flowing into Gonggeomji. After approximately 980 yr BP, water level rose during approximately 50 years due to precipitation increase.

Conveyance Analysis of Downstream of the Soyang Reservoir Considering the Influence of Vegetation (소양강 댐 직하류 하천의 식생 영향에 의한 통수능 분석)

  • Noh, Joonwoo;Shin, Hyunho;Kim, Hojoon
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.30 no.6B
    • /
    • pp.533-540
    • /
    • 2010
  • Recently management of vegetation distributed in the watercourse is very important not only for safety but also for river restoration. In general, vegetations in the watercourse increase hydraulic resistance and accordingly decrease conveyance capacity which may yield levee overflow. This paper simulates water level rise using 1D and 2D hydro dynamic model to check the possibility of overflow in downstream of the Soyang Reservoir by assigning different roughness coefficient corresponding to different types of vegetation. In this study, 3 different vegetation types of tree, shrub, and main channel were considered and corresponding Manning's roughness coefficient n was assigned based on the vegetation map generated from the site investigation. As results, the water level raised about 0.1 to 0.7 m comparing with the case without considering vegetation and a proper measurements is necessary where overflow occurs due to low level levee.

Assessment of Hydraulic Behavior and Water Quality Variation Characteristics in Underground Reservoir (지하저수조의 수리적 거동과 수질변화 특성 평가)

  • Lee, H.D.;Bae, C.H.;Kim, J.H.;Hwang, J.W.;Hong, S.H.
    • Journal of Korean Society on Water Environment
    • /
    • v.21 no.1
    • /
    • pp.52-58
    • /
    • 2005
  • The assessment on characteristics of hydraulic behavior and water quality variations of underground reservoirs of buildings were studied. Firstly, it was thought that underground reservoir capacities($m^3$) of buildings should be not determinated by the uniform and same methods but be estimated on the basis of the dwelling areas on dominated households and their residential characteristics, because these characteristics influence significantly on actual water usages and patterns of buildings. Secondly, it was likely that the average reduction rate of residual chlorine in underground reservoirs were affected from the their capacities, because the average reduction rate of residual chlorine in underground reservoirs under $1,000m^3$ was 43 percent, on the other hand, that rate of underground reservoirs over $1,000m^3$ was 60 percent. Thirdly, through the field investigation, the retention time of drinking water in underground reservoirs were in the range from 0.3 day to 3.9 day. In addition to, the average reduction rate of residual chlorine were depended largely on the retention time of drinking water. When the retention time was under 24 hours, the average reduction rate of residual chlorine was 45 percent, and in case of over 24 hours, was 49 percent. Fourth, water level in underground reservoirs was averagely varied in the range from 0.1 m to 2.65 m at the height of underground reservoirs. If considered actual height of underground reservoirs, 37.6 percent of the height of underground reservoirs was only used. Consequently, the frequency of the inflow and outflow of drinking water in underground reservoir were very increased, and had an effect on the reduction of residual chlorine. Lastly, the investigations on hydraulic structure characteristics of underground reservoirs inside showed the locations of inflow and outflow of drinking water almost were in the opposite direction. And some buildings had several baffles in the middle. Nevertheless, their installations had no beneficial for the improvement of water quality.