• Title/Summary/Keyword: Water leak repair

Search Result 18, Processing Time 0.026 seconds

A Study on the Applicability of Acrylic Water Leak Repair Materials used to Repair Cracks in Conduits and Underground Structures (관거 및 지하구조물 균열 보수에 사용되는 아크릴 누수 보수재의 적용성에 대한 연구)

  • Eunmi Lee;Kyungik Gil
    • Journal of Wetlands Research
    • /
    • v.26 no.2
    • /
    • pp.139-146
    • /
    • 2024
  • Various injection materials, such as asphalt-based injection materials, urethane-based injection materials, cement- based injection materials, and acrylic-based injection materials, are used for the repair of aged conduits and underground structures with cracks. In this study, research was conducted on an environmentally friendly acrylic- based leak repair material that exhibits good curing properties even in humid conditions and stability in temperature fluctuations. To compare the performance of the improved acrylic leak repair material with the existing acrylate injection material, experiments were conducted using KS standard methods, including underwater length change rate tests, underwater leakage resistance tests, and chemical performance tests. The comparative experiments revealed that the improved acrylic leak repair material showed no changes in shrinkage due to humidity, temperature variations, or chemical reactions compared to the existing acrylate injection material. In the underwater resistance test, the improved acrylic leak repair material did not show any leakage. Additionally, to assess the environmental impact of the improved acrylic leak repair material, acute fish toxicity tests and acute oral toxicity tests were conducted, and the results showed no mortality and no specific concerns with the test specimens. The experimental results led to the conclusion that the improved acrylic leak repair material is considered to be superior in performance, environmentally safe, and harmless to the human body. Based on various experimental results, it is inferred that the improved acrylic leak repair material is suitable for use as a repair material for cracks in manholes and underground structures compared to the existing acrylate repair material. This study aims to propose valuable data for future technological development by evaluating the applicability of acrylic leak repair materials.

Pinpointing of Leakage Location Using Pipe-fluid Coupled Vibration (파이프-유체의 연성진동을 이용한 누수위치 식별연구)

  • 이영섭;윤동진
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.14 no.2
    • /
    • pp.95-104
    • /
    • 2004
  • Leaks in underground pipelines can cause social, environmental and economical problems. One of relevant countermeasures against leaks is to find and repair of leak points of the pipes. Leak noise is a good source to identify the location of leak points of the pipelines. Although there have been several methods to detect the leak location with leak noise, such as listening rods, hydrophones or ground microphones, they have not been so efficient tools. In this paper, accelermeters aroused to detect leak locations which could provide an easier and more efficient method. Filtering, signal processing and algorithm of raw input data from sensors for the detection of leak location are described. A 120m-long and a 70m-long experimental pipeline systems are installed and the results with the systems show that the algorithm with the accelerometers offers accurate pinpointing for leaks location detection. Theoretical analysis of sound wave propagation speed of water in underground pipes, which is critically important in leak locating, is also described.

Pinpointing of Leakage Location of Water Pipelines using Accelerometers (가속도계를 이용한 상수도 배관의 누수위치 식별연구)

  • 이영섭;윤동진;정중채
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2003.05a
    • /
    • pp.821-826
    • /
    • 2003
  • Leaks in underground pipelines can cause social, environmental and economical problems. One of a good contermeasures of leaks Is to find and repair of leak points of pipes. Leak noise is a good source to identify the location of leak points of pipelines. Although there have been several methods to detect the leak location with leak noise, such as listening rods, hydrophones or ground microphones, they were not so efficient tools beca. In this paper, two accelermeters are used to detect leak locations which could provide an easier and efficient method. The filtering, signal processing and algorithm is described for the detection of leak location. A 120m-long pipeline system for experiment is installed and the results with the system show that the algorithm with the two accelerometers gives very accurate pinpointing of leaks. Theoretical analysis of sound wave propagation speed in underground pipes is also described.

  • PDF

Study on Leak Rate of SCC Degraded Alloy 600 Tubings of PWRs

  • Hwang, Seong Sik;Kim, Joung Soo;Kasza, Ken E.;Park, Jangyul
    • Corrosion Science and Technology
    • /
    • v.3 no.6
    • /
    • pp.233-239
    • /
    • 2004
  • Primary water stress corrosion cracking of steam generator tubings occur on many tubes in pressurized water reactors(PWRs), and they are repaired using sleeves or plugs. In order to develop proper repair criteria, it is necessary to know the leak behavior of the tubes, which have stress corrosion cracks. Crack development tests were carried out on the tubes at room temperature, and leak rate and burst pressure were measured on the degraded tubes at room temperature and a high temperature. No leakage was detected on the tubes where 100 % through wall crack developed, at 1560 psi, which is an operating pressure difference of pressurized water reactors(PWRs). In some tests, leak rates of the tubes increased with time at a constant internal water pressure. A test tube showed a very small amount of leakage at 2700 psi in a high temperature pressure test at $282^{\circ}C$, but it disappeared after the pressure increased slightly. Even cracks are 100 % through wall, they need to open in order to reach a certain amount of leak rate at the operating pressure difference.

Analysis of Flow and Economic Benefit Through Water Leakage Detection and Repair (누수탐사에 의한 유량분석 및 보수의 경제적 효과)

  • Lee, Seung-Chul;Lee, Sang-Il
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.19 no.1
    • /
    • pp.8-15
    • /
    • 2005
  • Field measurement data on water leakage are not readily available and it causes inaccurate assessment of water demand and poor supply planning. In this study, the procedure for leakage detection and unaccounted water calculation is proposed and applied to a city. The city has suffered from the significant amount of leak water and the financial loss as a result. Measurements were made for pressure and flow at 18 locations before and after the repair. Repair of the leakage increased pressure up to $2.0kgf/cm^2$ and saved 17.1% of water supply from distribution reservoirs. Monetary value of annual water savings for the entire city amounts to 1 billion won. It is believed that leakage detection and data analysis conducted in this study will contribute to the change of current practice and to the establishment of better water supply management system.

Rapid microcement and glycidylacrylate a Case Study on the Improvement of Water Leakage Site Applied to Mixed-use (급결마이크로시멘트 및 글리시딜아크릴레이트를 복합 적용한 누수현장 보수사례)

  • Cho, Il-Kyu;Yuh, Jae Hyung;Oh, Sang-Keun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2019.11a
    • /
    • pp.241-242
    • /
    • 2019
  • This technology is a water leak repair technology using composite materials of concrete structures that block leakage of structures by injecting rapid microcement into the face of underground concrete to block water and injecting flexible glycidylacrylate. Rapid micro cement system repair materials are mixed with fine fibers to improve the flexural sensitivity of the material and to form a layer that blocks stabilized water at the back of the structure by allowing rapid and tight spatial filling during injection with high cohesion The glycidylacrylate repair material can control the expansion rate, and the external stress also has the characteristic that the form of the material is not destroyed or separated, which can also be applied to vibrating induced structures that produce repetitive fatigue loads, and has an effective durability in saline, alkali, acid (chloric acid, sulfuric acid, nitric acid).

  • PDF

Production of SCC Flaws and Evaluation Leak Behavior of Steam Generator Tubes (누설 및 파열실험용 SCC 결함 전열관 제작 및 누설거동 평가)

  • Hwang, Seong-Sik;Jung, Man-Kyo;Park, Jang-Yul;Kim, Hong-Pyo
    • Corrosion Science and Technology
    • /
    • v.8 no.5
    • /
    • pp.188-192
    • /
    • 2009
  • A forced outage due to a steam generator tube leak in a Korean nuclear power plant was reported.1) Primary water stress corrosion cracking has occurred in many tubes in the plant, and they were repaired using sleeves or plugs. In order to develop proper repair criteria, it is necessary to understand the leak behavior of the tubes containing stress corrosion cracks. Stress corrosion cracks were developed in 0.1 M sodium tetrathionate solution at room temperature. Steam generator(SG) tubes with short cracks were successfully fabricated with a restricted solution contact method. The leak rates of the degraded tubes were measured at room temperature. Some tubes with 100 % through wall cracks showed an increase of leak rate with time at a constant pressure.

Path of Water Leakage of PC Apartment House 15 Years Have Elapsed (15년 경과한 PC아파트의 누수경로 조사결과)

  • Lee, Jung-Hun;Bae, Kee-Sun;Kim, Sang-Youn;Choi, Sung-Min;Oh, Sang-Keun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2014.05a
    • /
    • pp.156-157
    • /
    • 2014
  • PC apartment house 15 years have elapsed have various deteriorations by water leakage in roof and wall. The prior investigation such as investigating of leakage repair history of PC apartment and the field investigation were carried out to solve the water leak problem in its structure. The path of water was analyzed on the parts of greatest water leak such as roof parapet, roof floor, side wall, corridor and balcony. As a result, the specific path of the water leakage was identified in various structure units.

  • PDF

Burst Behavior for Mechanically Machined Axial Flaws of Steam Generator Tubings

  • Hwang, Seong Sik;Kim, Hong Pyo;Kim, Joung Soo
    • Corrosion Science and Technology
    • /
    • v.3 no.1
    • /
    • pp.30-33
    • /
    • 2004
  • It has been reported that some events of a rupture of seam generator tube have occurred in nuclear power plants around the world. Main causes of the leakage are from various types of corrosion in the steam generator(SG) tubings. Primary water stress corrosion cracking(PWSCC) of steam generator tubings have occurred in many tubes in Korean plant, and they were repaired using sleeves or plugs, In order to develop proper repair criteria, it is necessary to ascertain the leak behavior of the tubings. A high pressure leak and burst testing system was manufactured. Various types of Electro Discharged Machined (EDM) notches were developed on the SG tubes. Leak rate and burst pressure were measured on the tubes at room temperature. Burst pressure of the part through wall defected tubes depends on the defect depth, Water flow rates after the burst were independent of the t1aw types; tubes having 20 to 60 mm long EDM notches showed similar flow rates regardless of the defect depth. A fast pressurization rate gave the tube a lower burst pressure than the case of a slow pressurization.

Development of Standard Guideline for Water-leakage and Maintenance by parts of the Underground Structures in Multi-Family Housing - A Case Analysis of Water Leak Diagnosis - (공동주택 지하구조물의 부위별 표준 누수 진단 유지관리 지침 개발 - 누수 진단 사례 분석 -)

  • Kim, Soo Yeon;Lee, Jung Hun;Song, Je Young;Jang, Duk Bae;Oh, Sang Keun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2017.05a
    • /
    • pp.142-143
    • /
    • 2017
  • An analysis of the current water leak status of understand structure (underground parking lots, staircases, plumbing systems, water reservoirs, etc.) of multi-family housing in South Korea shows that water leaks are found from cracks in all areas of the underground structure caused by the degradation environment (water pressure by underground water, humidity, temperature, earth pressure, soil behaviour and vibration, etc.), which result in various problems, including mold, malodour, debonding of finishing materials, exfoliation, breakout, water leaks in electrical boxes, efflorescence, sedimentation of calcium hydroxide, decoloration, rusting, damages and pollution among others. Therefore, this study aims to analyse the current status of water leaks in underground structure and use the results as the basic data for developing a standard guideline for water leaks and maintenance by parts of the underground structure of multi-family housing.

  • PDF