• Title/Summary/Keyword: Water heating temperature

Search Result 1,005, Processing Time 0.03 seconds

Estimation of fire Experiment Prediction by Utility Tunnels Fire Experiment and Simulation (지하공동구 화재 실험 및 시뮬레이션에 의한 화재 설칠 예측 평가)

  • 윤명오;고재선;박형주;박성은
    • Fire Science and Engineering
    • /
    • v.15 no.1
    • /
    • pp.23-33
    • /
    • 2001
  • The utility tunnels are the important facility as a mainstay of country because of the latest communication developments. However, the utilities tunnel is difficult to deal with in case of a fire accident. When a cable burns, the black smoke containing poisonous gas will be reduced. This black smoke goes into the tunnel, and makes it difficult to extinguish the fire. Therefore, when there was a fire in the utility tunnel, the central nerves of the country had been paralyzed, such as property damage, communication interruption, in addition to inconvenience for people. This paper is based on the fire occurred in the past, and reenacting the fire by making the real utilities tunnel model. The aim of this paper is the scientific analysis of the character image of the fire, and the verification of each fire protection system whether it works well after process of setting up a fire protection system in the utilities tunnel at a constant temperature. The fire experiment was equipped with the linear heat detector, the fire door, the connection water spray system and the ventilation system in the utilities tunnel. Fixed portion of an electric power supply cable was coated with a fire retardant coating, and a heating tube was covered with a fireproof. The result showed that the highest temperature was $932^{\circ}c$ and the linear heat detector was working at the constant temperature, and it pointed at the place of the fire on the receiving board, and Fixed portion of the electric power supply cable coated with the fire retardant coating did not work as the fireproof. The heating tube was covered with the fireproof about 30 minutes.

  • PDF

Field Survey of Greenhouse for Strawberry Culture -Case Study Based on Western Gyeongnam Area- (딸기재배 온실의 현장조사 분석 -서부경남 지역을 중심으로-)

  • Jeong, Young Kyun;Lee, Jong Goo;Yun, Sung Wook;Kim, Hyeon Tae;Yoon, Yong Cheol
    • Journal of Bio-Environment Control
    • /
    • v.27 no.3
    • /
    • pp.253-259
    • /
    • 2018
  • This study set out to select a system to realize an optimal environment for strawberry cultivation greenhouses based on data about the growth and development of strawberry and its environment and to provide basic data for the research of its improved productivity. For these purposes, the investigator conducted a field survey with greenhouses for strawberry cultivation in western Gyeongnam. The findings show that farmers in their fifties and sixties accounted for the biggest part in the age groups of strawberry farmers. While those who were under 50 were accounted for approximately 67.5%, those who were 60 or older accounted for 32.5%. As for cultivation experiences, the majority of the farmers had ten years of cultivation experiences or less with some having 30 years of cultivation experiences or more. All the farmers built an arch type single span greenhouse. Those who used nutrient solutions were about 75.0%, being more than those who used soil. All of the farmers that used a nutrient solution adopted an elevated hydroponic system. The single span greenhouses were in the range of 7.5~8.5m, 1.3~1.8m and 2.5~3.5m for width, eaves, and ridge height, respectively, regardless of survey areas. The rafters interval was about 0.7~0.8m. In elevated hydroponic cultivation, the width, height, and interval of the beds were about 0.25m, 1.2m and 1.0m, respectively. As for the strawberry varieties, the domestic ones accounted for approximately 97.5% with Seolhyang being the most favorite one at about 65.0%. As for the internal environment factors of greenhouses, 38 farmers measured only temperature and relatively humidity. As for hydroponics, the farmers used a hydroponics control system. Except for the farmers that introduced a smart farm system for temperature and humidity control, approximately 85.0% controlled temperature and humidity only with a control panel for side windows and ventilation fans. As for heating and heat insulation, all of the farmers were using water curtains with many farmers using an oil or electric boiler, radiating lamp or non-woven fabric, as well, when necessary.

Detoxification of PSP and relationship between PSP toxicity and Protogonyaulax sp. (마비성패류독의 제독방법 및 패류독성과 원인플랑크톤과의 관계에 관한 연구)

  • CHANG Dong-Suck;SHIN Il-Shik;KIM Ji-Hoe;PYUN Jae-hueung;CHOE Wi-Kung
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.22 no.4
    • /
    • pp.177-188
    • /
    • 1989
  • The purpose of this study was to investigate the detoxifying effect on PSP-infested sea mussel, Mytilus edulis, by heating treatment and correlation between the PSP toxicity and the environmental conditions of shellfish culture area such as temperature, pH, salinity, density of Protogonyaulax sp. and concentration of inorganic nutrients such as $NH_4-N,\;NO_3-N,\;NO_2-N\;and\;PO_4-P$. This experiment was carried out at $Suj\u{o}ng$ in Masan, Yangdo in Jindong, $Hach\u{o}ng\;in\;K\u{o}jedo\;and\;Gamch\u{o}n$ bay in Pusan from February to June in $1987\~1989$. It was observed that the detection ratio and toxicity of PSP in sea mussel were different by the year even same collected area. The PSP was often detected when the temperature of sea water about $8.0\~14.0^{\circ}C$. Sometimes the PSP fox of sea mussel was closely related to density of Protogonyaulax sp. at $Gamch\u{o}n$ bay in Pusan from March to April in 1989, but no relationship was observed except above duration during the study period. The concentration of inorganic nutrients effects on the growth of Protogonyaulax sp., then effects of $NO_3-N$ was the strongest among them. When the PSP-infested sea mussel homogenate was heated at various temperature, the PSP toxicity was not changed significantly at below $70^{\circ}C$ for 60 min. but it was proper-tionaly decreased as the heating temperature was increased. For example, when the sea mussel homogenate was heated at $100^{\circ}C,\;121^{\circ}C$ for 10 min., the toxicity was decreased about $67\%\;and\;90\%$, respectively. On the other hand, when shellstock sea mussel contained PSP of $150{\mu}g/100g$ was boiled at $100^{\circ}C$ for 30 min. with tap water, the toxicity was not detected by mouse assay, but that of PSP of $5400{\mu}g/100g$ was reduced to $57{\mu}g/100g$ even after boiling for 120 min.

  • PDF

Comparison of the Content of Shizandrin, Gomisin A and Gomisin N in Schisandra Fruit by Water Extraction Condition (오미자의 물 추출조건에 따른 shizandrin, gomisin A, gomisin N의 함량 비교)

  • Kim, Hee-Soon;Moon, Hyun-Kyung;Lee, Young-Ju;Lee, Chun-Young;Hwang, Kwang-Ho;Kim, Ouk-Hee;Yoo, In-Sil;Jung, Kweon
    • Journal of Food Hygiene and Safety
    • /
    • v.30 no.1
    • /
    • pp.59-64
    • /
    • 2015
  • This study compared the content change of physiological active substances according to the extraction condition when we generally drink the extractive of Schisandra fruit with using water. Physiological active substances of the Schisandra fruit, schizandrin, gomisin A and gomisin N were analysed with HPLC. The results of extracting 1 dose of the Schisandra fruit tea, which is some as 1 g of Schisandra fruit, in 100 mL of water by differing the extraction type, extraction temperature and extraction time were of the followings. The total content of schizandrin, gomisin A and gomisin N of powder type in $26^{\circ}C$ leaching was the highest (p < 0.05) as the leaching content of 24 hours (5.54 mg/g) showed difference with different times and the contents of raw type Schisandra fruit were less than 0.1 mg/g in all of extraction time. The contents of powder type Schisandra fruit in $60^{\circ}C$ heating extraction was over 4.50 mg/g except for the 5 minute (2.94 mg/g), and the contents of raw Schisandra fruit were less than 0.3 mg/g. In case of $100^{\circ}C$ heating extraction, the contents of powder type Schisandra fruit showed over 5.10 mg/g in every time zone, and the raw type Schisandra fruit was less than 1.0 mg/g.

Properties of Quercus variabilis bio-oil prepared by sample preparation (시료 조건에 따른 굴참나무 바이오오일의 특성)

  • Chea, Kwang-Seok;Jo, Tae-Su;Choi, Seok-Hwan;Lee, Soo-Min;Hwang, Hye-Won;Choi, Joon-Weon
    • Journal of the Korean Applied Science and Technology
    • /
    • v.32 no.1
    • /
    • pp.148-156
    • /
    • 2015
  • In this study the differences in the sample size and sample input changes as characteristics of bio-oil oak(Quercus variabilis), the oak 0.5~2.0 mm of the oak weighing 300~900g was processed into bio-oil via fast pyrolysis for 1.64 seconds. In this study, the physico-chemical properties of biooil using oak were investigated. Fast pyrolysis was adopted to increase the bio-oil yield from raw material. Although the differences in sample size and sample input changes in the yield of pyrolysis products were not significantly noticeable, increases in the yield of bio-oil accounted for approximately 60.3 to 62.1%, in the order of non-condensed gas, and biochar. When the primary bio-oil obtained by the condensation of the cooling tube and the seconary bio-oil obtained from the electric dust collector were measured separately, the yield of primary bio-oil was twice as higher than that of the secondary bio-oil. However, HHV (Higher Heating Value) of the secondary bio-oil was approximately twice as higher than that of the primary bio-oil by up to 5,602 kcal/kg. The water content of the primary bio-oil was more than 20% of the moisture content of the secondary bio-oil, which was 10% or less. In addition, the result of the elemental analysis regarding the secondary bio-oil, its primary carbon content was higher than that of the primary bio-oil, and since the oxygen content is low, the water content as well as elemental composition are believed to have an effect on the calorific value. The higher the storage temperature or the longer the storage period, the degree of the viscosity of the secondary bio-oil was higher than that of the primary bio-oil. This can be the attributed to the chemical bond between the polymeric bio-oil that forms during the storage period.

Antioxidant and anti-aging activities of water extracts from Chionanthus retusus flesh according to different extraction temperatures (추출온도에 따른 이팝나무 과육 물 추출물의 항산화 및 항노화 활성)

  • Choi, Hae-Sim;Lee, Yang-Suk;Seo, Su-Jeong;Kim, Nam-Woo
    • Food Science and Preservation
    • /
    • v.24 no.8
    • /
    • pp.1129-1137
    • /
    • 2017
  • The fringe tree, Chionanthus retusus (Oleaceae) has been used as a natural remedy that helps a paralytic stroke, dementia, phlegm and malaria. This study was conducted to investigate the antioxidant and anti-aging activities of water extracts obtained from the flesh of C. retusus by reflux extraction at room temperature and $80^{\circ}C$, and pressure heating extraction at $110^{\circ}C$, for an increment of their practical use. The highest extraction yield from the flesh of C. retusus was 67.94% extract by pressure heating extraction at $110^{\circ}C$. The content of total polyphenol compounds was the highest by 72.71 mg/g in $80^{\circ}C$ extract by reflux extraction. The highest content of total flavonoid compounds was 7.60 mg/g at $110^{\circ}C$ extract. The results of soluble protein and reducing sugar contents showed the highest content of 4.93 mg/g and 46.77 mg/g in $110^{\circ}C$ extract, respectively. In the analysis of DPPH radical scavenging activity, all extracts showed an excellent effect of 92% in 1.0 mg/mL concentration. The highest effect of ABTS radical scavenging activity was 88.67% at $110^{\circ}C$ extraction in 1.0 mg/mL concentration. Nitrite scavenging ability was the highest as 66.16% at $110^{\circ}C$ extract at pH 1.2 and 1.0 mg/mL concentration. The results of SOD-like activity and xanthine oxidase inhibition activities showed the highest effect of 14.95% and 59.45% at $110^{\circ}C$ extract in 1.0 mg/mL, respectively. Tyrosinase inhibition activity for whitening effect was the highest of 35.31% at $85^{\circ}C$ in 1.0 mg/mL. In the analysis of anti-aging effect, collagenase and elastase inhibition activity showed the highest effects of 37.78% at $110^{\circ}C$ and 20.39% at $80^{\circ}C$, respectively. All results of antioxidant activities and anti-aging effects increased along with the concentration increases. These results indicated that the extracts extracted from the flesh of C. retusus at $80^{\circ}C$ and $110^{\circ}C$ have a large amount of useful ingredients, an excellent antioxidant activity, like as DPPH and ABTS radical scavenging activity, and anti-aging effects to develop functional products than those of $25^{\circ}C$.

Development of Heat Exchanger for Fermentation Heat Utilization from Waste Woody Biomass (목질계 폐바이오메스의 발효열이용 열교환기의 개발)

  • Cho, Nam-Seok;Choi, Tae-Ho;Kim, Hong-Eun;Lee, Suk-Ho;Lee, Chung-Koo
    • Journal of the Korean Wood Science and Technology
    • /
    • v.37 no.1
    • /
    • pp.94-104
    • /
    • 2009
  • It is urgently required to develop the production of fermentation-heat energy from the waste agricultural and forest biomass and its effective heat exchanging system for the supply of warm water to rural households and greenhouses. In this study 3 helical-type and 1 plate-type heat exchangers using 3 different waste biomasses [e.g. hardwood (HW) sawdust (100%), softwood (SW) sawdust : HW sawdust (50 : 50) and HW sawdust : grass (90 : 10)] were applied in order to find out the best heat recovery system. The heat exchanger was basically considered to improve the overall heat recovery efficiency, to minimize heat loss and to simplify manufacturing, assembling and breaking up the fermenting beds. The helical-type heat exchanger (HX-H3) installed in fermenting bed of HW sawdust : grass (90 : 10) showed relatively higher temperature profiles, in particular mid- and upper-parts than lower and surface parts during 45-day fermentation process. The maximum temperature was ranged from $40^{\circ}C$ to $65^{\circ}C$ with average $60^{\circ}C$. The water temperature of tank outlet was ranged to $33{\sim}48^{\circ}C$ during whole measuring periods. By the way plate-type one (HX-P) installed in same biomass compositional fermenting bed showed $64.5{\sim}76.5^{\circ}C$ at center part, and $43{\sim}56^{\circ}C$ and $42{\sim}58^{\circ}C$, water tank and tank outlet temperatures, respectively, during 100 day measurement. It could be concluded that the plate-type heat exchanger (HX-P) provides not only the effective heating for the rural households and greenhouses, but also having the best heat recovery performance, easy manufacturing, assembling and breaking up the systems.

Coupled T-H-M Processes Calculations in KENTEX Facility Used for Validation Test of a HLW Disposal System (고준위 방사성 폐기물 처분 시스템 실증 실험용 KENTEX 장치에서의 열-수리-역학 연동현상 해석)

  • Park Jeong-Hwa;Lee Jae-Owan;Kwon Sang-Ki;Cho Won-Jin
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.4 no.2
    • /
    • pp.117-131
    • /
    • 2006
  • A coupled T-H-M(Thermo-Hydro-Mechanical) analysis was carried out for KENTEX (KAERI Engineering-scale T-H-M Experiment for Engineered Barrier System), which is a facility for validating the coupled T-H-M behavior in the engineered barrier system of the Korean reference HLW(high-level waste) disposal system. The changes of temperature, water saturation, and stress were estimated based on the coupled T-H-M analysis, and the influence of the types of mechanical constitutive material laws was investigated by using elastic model, poroelastic model, and poroelastic-plastic model. The analysis was done using ABAQUS, which is a commercial finite element code for general purposes. From the analysis, it was observed that the temperature in the bentonite increased sharply for a couple of days after heating the heater and then slowly increased to a constant value. The temperatures at all locations were nearly at a steady state after about 37.5 days. In the steady state, the temperature was maintained at $90^{\circ}C$ at the interface between the heater and the bentonite and at about $70^{\circ}C$ at the interface between the bentonite and the confining cylinder. The variation of the water saturation with time in bentonite was almost same independent of the material laws used in the coupled T-H-M processes. By comparing the saturation change of T-H-M and that of H-M(Hydro-Mechanical) processes using elastic and poroelastic material mod31 respectively, it was found that the degree of saturation near the heater from T-H-M calculation was higher than that from the coupled H-M calculation mainly because of the thermal flux, which seemed to speed up the saturation. The stresses in three cases with different material laws were increased with time. By comparing the stress change in H-M calculation using poroelasetic and poroelasetic-plastic model, it was possible to conclude that the influence of saturation on the stress change is higher than the influence of temperature. It is, therefore, recommended to use a material law, which can model the elastic-plastic behavior of buffer, since the coupled T-H-M processes in buffer is affected by the variation of void ratio, thermal expansion, as well as swelling pressure.

  • PDF

Development of Economic Culture System Using Wastewater for Microalgae in Winter Season (폐수를 이용한 겨울철 경제적 미세조류 배양 시스템의 개발)

  • Lee, Sang-Ah;Lee, Changsoo;Lee, Seung-Hoon;An, Kwang-Guk;Oh, Hee-Mock;Kim, Hee-Sik;Ahn, Chi-Yong
    • Korean Journal of Environmental Biology
    • /
    • v.32 no.1
    • /
    • pp.58-67
    • /
    • 2014
  • The outdoor mass cultivation is not possible for microalgae in Korea all year round, due to cold winter season. It is not easy to maintain proper level of productivity of microalgae even in winter. To prevent a drastic decrease of temperature in a greenhouse, two layers were covered additionally, inside the original plastic layer of the greenhouse. The middle layer was made up of plastic and the inner layer, of non-woven fabric. Acrylic transparent bioreactors were constructed to get more sunlight, not only from the upper side but also from the lateral and bottom directions. In winter at freezing temperatures, six different culture conditions were compared in the triply covered, insulated greenhouse. Wastewater after anaerobic digestion was used for the cultivation of microalgae to minimize the production cost. Water temperature in the bioreactors remained above $10^{\circ}C$ on average, even without any external heating system, proving that the triple-layered greenhouse is effective in keeping heat. Algal biomass reached to 0.37g $L^{-1}$ with the highest temperature, in the experimental group of light-reflection board at the bottom, with nitrogen and phosphorus removal rate of 92% and 99%, respectively. When fatty acid composition was analyzed using gas-chromatography, linoleate (C18 : 3n3) occupied the highest proportion up to 61%, in the all experiment groups. Chemical oxygen demand (COD), however, did not decrease during the cultivation, but rather increased. Although the algal biomass productivity was not comparable to warm seasons, it was possible to maintain water temperature for algae cultivation even in the coldest season, at the minimum cost.

Evaluation of the Temperature Drop Effect and the Rutting Resistance of Moisture Retaining-Porous Asphalt Pavement Using Accelerated Pavement Testing (포장가속시험을 이용한 보수형 배수성 포장의 온도저감 효과 및 소성변형 저항특성 연구)

  • Kwak, Byoung-Seok;Suh, Young-Chan;Song, Chul-Young;Kim, Ju-Won
    • International Journal of Highway Engineering
    • /
    • v.11 no.3
    • /
    • pp.97-109
    • /
    • 2009
  • One of the main causes of asphalt rutting is high temperature of the pavement. Nevertheless, there has been few research on lowering the pavement temperature for reducing rutting. This study investigated the performance characteristics of moisture-retaining porous asphalt pavement, which is known to have a temperature reducing effect. The purpose of this study is to quantify the temperature reducing effect of moisture-retaining porous asphalt pavement and its effect of reducing rutting through Accelerated Pavement Testing(APT). Additionally, the possibility of reducing the thickness of the pavement in comparison to general dense grade pavement by analyzing structural layer coefficient of moisture retaining pavement. A total of three test sections consisting of two moisture-retaining porous asphalt pavement sections and one general dense-grade porous asphalt pavement section were constructed for this study. Heating and spraying of water were carried out in a regular cycle. The loading condition was 8.2 ton of wheel load, the tire pressure of $7.03kgf/cm^2$, and the contact area of $610cm^2$. The result of this experiment revealed that the temperature reducing effect of the pavement was about $6.6{\sim}7.9^{\circ}C$(average of $7.4^{\circ}C$) for the middle layer and $7.9{\sim}9.8^{\circ}C$(average of $8.8^{\circ}C$) for surface course, resulting in a rutting reduction of 26% at the pavement surface. Additionally, the structural layer coefficient of moisture retaining pavement measured from a laboratory test was 0.173, about 1.2 times that of general dense grade pavement. The general dense-grade porous asphalt pavement test section exhibited rutting at all layers of surface course, middle layer, and base layer, while the test sections of moisture-retaining porous asphalt pavement manifested rutting mostly at surface course only.

  • PDF