• 제목/요약/키워드: Water heater

검색결과 352건 처리시간 0.026초

열펌프 온수기의 부하 대응 축열조 제어에 관한 연구 (A Study on Control Method of Thermal Storage Tank for Varying Thermal Load in Heat Pump Water Heater)

  • 남현규;배철호
    • 설비공학논문집
    • /
    • 제24권4호
    • /
    • pp.330-335
    • /
    • 2012
  • A characteristic behavior of the thermal storage tank for varying thermal load in heat pump water heater was studied. The control method was suggested and applied. By measuring the temperature within the storage tank, the heat pump was ON/OFF controlled. The appropriate measuring position and the size of heat exchanger gives the minimized power consumption of heat pump. As the length of heat exchanger increases, the temperature measuring position goes down of the storage tank and the power consumption increases.

평판형 히터를 이용한 알루미늄과 타이타늄 산화물 나노유체의 풀비등 임계열유속에 관한 실험적 연구 (Experimental Investigation on the Pool Boiling Critical Heat Flux of Water-Based Alumina and Titania Nanofluids on a Flat Plate Heater)

  • 안호선;김형대;조항진;강순호;김무환
    • 대한기계학회논문집B
    • /
    • 제33권10호
    • /
    • pp.729-736
    • /
    • 2009
  • Pool boiling heat transfer and critical heat flux (CHF) of water-based nanofluids with alumina and titania nanoparticles of 0.01% by volume were investigated on a disk heater at saturated and atmospheric conditions. The experimental results showed that the boiling in nanofluids caused the considerable increase in CHF on the flat surface heater. It was revealed by visualization of the heater surface subsequent to the boiling experiments that a major amount of nanoparticles deposited on the surface during the boiling process. Pool boiling of pure water on the surface modified by such nanoparticle deposition resulted in the same CHF increases as what boiling nanofluids, thus suggesting the CHF enhancement in nanofluids was an effect of the surface modification through the nanoparticle deposition during nanofluid boiling. Possible reasons for CHF enhancement in pool boiling of nanofluids are discussed with surface property changes caused by the nanoparticle deposition.

Development of Induction Heated Hot Water Producer using Soft Switching PWM High Frequency Inverter

  • Fujita Kentarou;Moisseev Serguei;Gaimage Laknath;Chandhaket Sarawouth;Muraoka Hidekazu;Nakaoka Mutsuo
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2003년도 춘계전력전자학술대회 논문집(2)
    • /
    • pp.491-494
    • /
    • 2003
  • This paper presents a new conceptual electromagnetic induction eddy current-based stainless steel plate spiral type heater for heat exchanger or Dual Packs Heater in hot water producer, boiler steamer and super heated steamer, which is more suitable and acceptable for new generation consumer power applications. In addition, all active clamped edge resonant PWM high frequency inverter using trench gate IGBTs power module can operate under a principle oi zero voltage soft communication with PWM is developed and demonstrated for a high efficient Induction heated hot water producer and boiler in the consumer power applications. This consumer induction heater power appliance using active clamp soft switching PWM high frequency inverter is evaluated and discussed on the basis of the simulation and experimental results.

  • PDF

가압기 전열기 슬리브 및 J-Groove 용접부의 자동 초음파검사 (Automatic Ultrasonic Inspection on Heater Sleeves and J-Groove Welds of Pressurizer)

  • 류승우;장희준;김선제;이상덕;성종환
    • 한국압력기기공학회 논문집
    • /
    • 제6권2호
    • /
    • pp.20-27
    • /
    • 2010
  • In order to prevent the corrosion of component contacted primary water designed alloy 600 material in the nuclear power plant. But the primary water stress corrosion cracking(PWSCC) of alloy 600 and weld area occurs continuously due to the residual stress. The leakage accident resulted from PWSCC in the drain nozzle of the steam generator of domestic power plants. Heater sleeves of the pressurizer are welded with alloy 600 weld material and therefore exposed to the primary water environment. PWSCC occurred in heater sleeve material and weld area of many foreign power plants. The current issue of domestic nuclear power plants are consequently concentrated to PWSCC of similar material. In order to improve the detection and the sizing of the PWSCC in the welding sleeve of the pressurizer, the automatic UT system and multi-directions probe sets have been developed. The experimental studies have been performed using the mock-up block containing artificial reflectors(ID connected EDM notch) and semi-artificial cracks made from thermal fatigue. The automatic UT System is applied in the detection and the length sizing of the ID/OD on the tube and the J-groove weld area of the artificial reflectors and results of the detection and the sizing are compared respectively. Also, the developed automatic UT system is successfully accomplished to inspect the heater sleeve and the J-groove weld area on the pressurizer for the detection of PWSCC.

  • PDF

수중 발열을 위한 Glass/Mo/ZnO/Glass 구조의 박막형 발열체 연구 (A Study on Glass/Mo/ZnO/Glass Thin-film-heaters for Water Heating)

  • 김지우;최두호
    • 마이크로전자및패키징학회지
    • /
    • 제29권1호
    • /
    • pp.43-47
    • /
    • 2022
  • 본 연구에서는 보일러 등에 적용을 하기 위하여 물속에 담군 채 가열할 수 있는 친환경 박막형 히터에 대한 결과를 보고한다. 장수명을 확보하기 위하여 소재 안정성이 높은 Mo 박막(40 nm)을 마그네트론 스퍼터법을 이용하여 Glass 기판상에 증착하였으며 후속 공정 진행 시 Mo 박막의 부식을 방지하기 위하여 상부에 ZnO 박막 (60 nm)을 형성하였다. 이후 투명 접착성을 가지는 PVB (Polyvinyl Butyral)를 이용하여 ZnO 박막 상부에 또 다른 Glass기판을 올려두고 열풍건조기 내에서 150℃의 온도에서 2시간동안 PVB를 경화시키며 접착시켜 Glass/Mo/ZnO/Glass 구조의 수중 히터를 완성하였다. 이렇게 제작한 발열체를 수중에 담근 후 발열 시 물의 온도가 2분 내 50℃까지 상승되는 것을 확인하였으며 미미한 수준의 저항증가가 발생하며 구조적 안정성 또한 확보되었다. 인가 전압의 세기에 따라 발열체의 온도가 제어되기 때문에 보일러에 적용할 때 사용자가 설정하는 온도를 용이하게 제어할 수 있을 것이라 기대된다. 마지막으로, 본 연구에서 제작한 박막형 히터는 반투명의 특성을 가져 심미성을 부여할 수 있어 제품의 부가가치를 더욱 높일 수 있을 것으로 기대된다.

증발부에 편심 가열부를 사용한 버블젯 루프 히트파이프의 열성능 (Thermal Performance of the Bubble Jet Loop Heat Pipe Using Eccentric Heater in Evaporating Section)

  • 김종수;김성복
    • 설비공학논문집
    • /
    • 제27권12호
    • /
    • pp.652-658
    • /
    • 2015
  • The Bubble Jet Loop Heat Pipe (BJLHP) is designed to operate in the horizontal orientation. The motion of the bubble generated by boiling working fluid on a heater surface in the evaporating section of the BJLHP helps the working fluid transfer heat to the condensing portion. In this study, we changed the position of the heater in the evaporating section from concentric to eccentric. The concentric heater is located at the center of the tube in the evaporating part, and the eccentric heater is located at the bottom of the inner surface of the same tube. We used R-134a as the working fluid, and the charging ratio was 50%vol. We measured the temperatures of the evaporating and condensing sections by changing the input electric power from 50 W to 200 W, measuring every 50 W. The results of the experiment show that the effective thermal conductivity of BJLHP using an eccentric heater is four times higher than the BJLHP obtained using a concentric heater. Additionally, we conducted a visualization experiment on the evaporating portion of BJLHP to determine why the effective thermal conductivity was higher. The working fluid was water, and we took pictures of the flow visualization for BJLHP. Nucleate boiling with the eccentric heater was more intense and generated more bubbles. Therefore, the eccentric heater was more saturated by the liquefied working fluid.

기포를 이용한 마이크로 액츄에이터 개발 (The Micro-Actuator Development of using the Bubble)

  • 최종필;반준호;전병희;장인배;김헌영;김병희
    • 한국소성가공학회:학술대회논문집
    • /
    • 한국소성가공학회 2003년도 추계학술대회논문집
    • /
    • pp.381-385
    • /
    • 2003
  • This paper presents the fabrication possibility of the micro actuator which uses a micro-thermal bubble, generated by a micro-heater under pulse heating. The micro-actuator is consist of three plate. The lower plate includes the channel and chamber are fabricated on high processability silicon wafer by the DRIE(Deep Reactive ion Etching) process. The middle plate includes the chamber and diaphragm, and the upper plate is the micro-heater. The micro-heater designed non-uniform width and results in periodic generation of stable single bubbles in D.I water. The single bubble appears precisely on the narrow part of the micro-heater and control is recorded.

  • PDF

태양열 공기-물 가열기의 공기 가열 성능 평가 및 열적 성능 개선을 위한 실험적 연구 (Experimental Study for Estimation of Air Heating Performance and Improvement of Thermal Performance of Hybrid Solar Air-water Heater)

  • 최휘웅;김영복;윤정인;손창효;최광환
    • 한국태양에너지학회 논문집
    • /
    • 제37권1호
    • /
    • pp.47-57
    • /
    • 2017
  • Solar energy is one of the important renewable energy resources. It can be used for air heating, hot water supply, heat source of desiccant cooling system and so on. And many researches for enhancing efficiency have been conducted because of these various uses of solar thermal energy. This study was performed to investigate the air heating performance of hybrid solar air-water heater that can heat air and liquid respectively or simultaneously and finding method for improving thermal performance of this collector. This collector has both liquid pipe and air channel different with the traditional solar water and air heater. Fins were installed in the air channel for enhancing the air heating performance of collector. Also air inlet & outlet temperature, ambient temperature and solar collector's inner part temperature were confirmed with different air velocity on similar solar irradiance. As a result, temperature of heated air was shown about $43^{\circ}C$ to $60^{\circ}C$ on the $30^{\circ}C$ of ambient temperature and thermal efficiency of solar collector was shown 28% to 73% with respect to air velocity. Also, possibility of improvement of thermal performance of this collector could be ascertained from the heat transfer coefficient calculated from this experiment. Thus, it is considered that the research for finding optimal structure of hybrid solar air-water heater for enhancing thermal performance might be needed to conduct as further study based on the method for improving air heating performance confirmed in this study.

전기히터식 및 지열원 히트펌프식 농산물 열풍건조기의 에너지 성능 비교 (Energy Performance Comparison of Electric Heater and Geothermal Source Heat Pump type Agricultural Hot Air Dryers)

  • 양원석;김영일;박승태
    • 한국지열·수열에너지학회논문집
    • /
    • 제14권4호
    • /
    • pp.7-12
    • /
    • 2018
  • Energy performance of electric heater and geothermal source heat pump type hot air dryers are compared in this study. For set temperatures of $30^{\circ}C$, $35^{\circ}C$ and $40^{\circ}C$, radish is dried from initial mass 60 kg until it gets 5 kg, where the difference equals the amount of water removed. As set temperature is increased, drying time is shortened for both electric heater and heat pump types, however energy efficiency is decreased due to increasing electricity consumption. Moisture extraction rate(MER) of electric heater is 2.58~2.84 kg/h, and for heat pump type 2.56~2.71 kg/h, showing little difference between the two types. Specific moisture extraction rate (SMER) of electric heater is 0.94~0.96 kg/kWh, and for heat pump type 1.72~2.21 kg/kWh. SMER of heat pump type is greater by 0.78~1.25 kg/kWh than the electric heater hot air dryer, which is 1.8~2.3 times better in terms of energy efficiency.

Experimental study of bubble behaviors and CHF on printed circuit board (PCB) in saturated pool water at various inclination angles

  • Tanjung, Elvira F.;Alunda, Bernard O.;Lee, Yong Joong;Jo, Daeseong
    • Nuclear Engineering and Technology
    • /
    • 제50권7호
    • /
    • pp.1068-1078
    • /
    • 2018
  • Experiments were performed to investigate bubble behaviors and pool boiling Critical Heat Flux (CHF) on a thin flat rectangular copper heater fabricated on Printed Circuit Board (PCB), at various inclination angles. The surface inclination angles were $0^{\circ}$, $45^{\circ}$, $90^{\circ}$, $135^{\circ}$, and $180^{\circ}$. Results showed the Onset of Nucleate Boiling (ONB) heat flux increased with increasing heater orientation from $0^{\circ}$ to $90^{\circ}$, while early ONB occurred when the heater faced downwards ($135^{\circ}$ and $180^{\circ}$). The nucleate boiling was observed to be unstable at low heat flux (1-21% of CHF) and changed into typical boiling when the heat flux was above 21% of CHF. The result shows the CHF decreased with increasing heater orientation from $0^{\circ}$ to $180^{\circ}$. In addition, the bubble departure diameter at the heater facing upwards ($0^{\circ}$, $45^{\circ}$, and $90^{\circ}$) was more prominent compared to that of the heater facing downward ($135^{\circ}$). The nucleation site density also observed increased with increasing heat flux. Moreover, the departed bubbles with larger size were observed to require a longer time to re-heat and activate new nucleation sites. These results proved that the ONB, CHF, and bubble dynamics were strongly dependent on the heater surface orientation.