• 제목/요약/키워드: Water curing

검색결과 936건 처리시간 0.034초

콘크리트의 염소이온 확산특성에 미치는 양생조건의 영향 (Effect of Curing Conditions on the Characteristics of Chloride Ion Diffusion in Concrete)

  • 임병탁;배수호;정영수;심은철;하재담
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2003년도 봄 학술발표회 논문집
    • /
    • pp.715-720
    • /
    • 2003
  • The chief factors for the penetration and diffusion of chloride ions in concrete are water-cement ratio(W/C), aging, curing conditions, chloride ions concentration of given environment., wet and dry conditions and etc. In this study, of these factors effect of curing conditions such as standard and outdoor curing on the characteristics of chloride ions diffusion in concrete were researched when environmental factors for the penetration and diffusion of chloride ions were constant. For this purpose, the voltages passing through the diffusion cell were measured by using accelerated test method using potential difference, and then diffusion coefficients of chloride ions by using Andrade's method were estimated for 44%, 49.5% and 60% of w/c, respectively. As a result., according to curing conditions correlation among diffusion coefficients of chloride ions, W/C and aging were concluded through multiple regression model.

  • PDF

양생온도가 플라이애시를 사용한 콘크리트의 초기강도발현에 미치는 영향 (Effect of Curing Temperature on Early Age Strength Development of the Concrete Using Fly Ash)

  • 한민철;신병철
    • 한국환경과학회지
    • /
    • 제19권1호
    • /
    • pp.105-114
    • /
    • 2010
  • The objective of the paper is to experimentally investigate the compressive strength of the concrete incorporating fly ash. Ordinary Portland cement(OPC). Water to binder ratio(W/B) ranging from 30% to 60% and curing temperature ranging from $-10^{\circ}{\sim}65^{\circ}C$ were also adopted for experimental parameters. Fly ash was replaced by 30% of cement contents. According to the results, strength development of concrete contained with fly ash is lower than that of plain concrete in low temperature at early age and maturity. In high curing temperature, the concrete with fly ash has higher strength development than that of low temperature regardless of the elapse of age and maturity. Fly ash can have much effect on the strength development of concrete at the condition of mass concrete, hot weather concreting and the concrete products for the steam curing.

양생요인 및 PP 섬유 혼입율 변화에 따른 고강도 콘크리트의 폭렬특성 (An Experimental Study on the Curing Method and PP Fiber Mixing Ratio on Spalling Resistance of High Strength Concrete)

  • 한천구;김원기
    • 한국건축시공학회지
    • /
    • 제9권6호
    • /
    • pp.113-119
    • /
    • 2009
  • 본 연구는 양생요인 및 PP 섬유 혼입율 변화에 따른 고강도 콘크리트의 기초적 특성 및 내화특성을 분석하였는데, 그 결과를 요약하면 다음과 같다. 콘크리트의 기초적 특성으로 유동성은 PP 섬유 혼입율이 증가 할수록 감소하는 경향을 나타내었고, 압축강도는 PP 섬유 혼입율 증가에 따라 약간 감소하였으나 재령 7일에서 모두 60 MPa 이상 재령 28일에서 90 MPa이상으로 고강도 범위를 나타내었다. 함수율 변화에 따른 폭렬성상으로 함수율 3.0 %에서 PP 섬유를 혼입하지 않은 플레인을 제외한 모든 배합에서 폭렬이 방지되는 것으로 나타났다. 이때 폭렬이 방지된 경우 잔존압축강도율은 22~41%, 질량감소율 5~7 %로 비교적 양호한 것으로 분석되었다. 양생방법 변화에 따른 폭렬성상으로 표준양생의 경우 PP 섬유 혼입율 0.05 % 이상, 증기 양생 및 오토클레이브의 경우 PP 섬유 혼입율 0.10 %에서 폭렬이 방지되는 것으로 나타났다. 이때 폭렬이 방지된 경우 잔존압축강도율은 23~42 %, 질량감소율은 7~11 % 전후로 나타났다. 이상을 종합하여 볼때 고강도 콘크리트는 함수율이 작을수록 폭렬방지가 용이하고, 양생방법에 따라서는 표준양생이 PP섬유 0.05 % 이상, 증기양생 및 오토클레이브의 경우 PP 섬유 혼입율 0.1 %이상을 혼입해 주어야 폭렬이 방지됨을 알수 있었다.

한중콘크리트의 현장 표면단열 양생공법 시공사례 연구 (Field Application of Surface Insulation Curing Method to Cold Weather Concreting)

  • 김종백;임춘근;한민철;김성수;한천구
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2005년도 추계 학술논문 발표대회
    • /
    • pp.25-28
    • /
    • 2005
  • This study investigates the field application of surface insulation curing method, which combined double layer bubble sheet(DBS) and thick-curing-material(TCM) for cold weather concreting. According to the test, deck slab, curing only upper section with DBS and TCM, does not make big different temperature history with that, curing both upper and bottom section during daily average temperature 6.5t. It is concluded that combination of DBS and TCM in only upper section can be safely cured in early period of time during cold water concreting. The field test was carried out with this favourable data. The upper deck slab was insulated by combination of DBS and TCM, and the construction was surrounded by tent. in order to protect from outside wind. The test result shows that the lowest temperature of deck slab indicated 6$ ^{circ}C $. It demonstrated that this curing method can resist early frost and save construction cost in the side of management and saving labor cost, compared with previous method. In addition, the column specimen, combined both form and bubble board, exhibited favorable temperature history, due to internal hydration heat insulation effect.

  • PDF

광중합기의 광도와 시간에 따른 글래스 아이오노머의 치수내 온도변화 (INTRAPULPAL TEMPERATURE CHANGE OF GLASS IONOMER ACCORDING TO LIGHT CURING INTENSITY AND CURING TIME)

  • 김희량;이형일;이광원;이세준
    • Restorative Dentistry and Endodontics
    • /
    • 제26권5호
    • /
    • pp.387-392
    • /
    • 2001
  • When cavity floor is near the pulp, polymerization of light-activated restorations results in temperature increase. This temperature increase cause by both the exothermic reaction process and the energy absorbed during irradiation. Therefore instating base is required. Most frequently used insulating base is glass ionmer. The purpose of this study was to evaluate intrapulpal temperature changes of glass ionomer according to various curing intensity and curing time. Caries and restoration-free mandibular molars extracted within three months were prepared Class I cavity of 3$\times$6mm with high speed handpiece. 1mm depth of dentin was evaluated with micrometer in mesial and distal pulp horns. Pulp chambers were filled with 37.0$\pm$0.1$^{\circ}C$ water to CEJ. Chromium-alumina thermocouple was placed in pulp horn for evaluating of temperature changes. glass ionomer material was placed in 2mm. total curing time was 40s: continuous 40s, intermittent 20s, intermittent 10s. Glass ionomer material was cured with 300mW/$\textrm{cm}^2$, 550mW/$\textrm{cm}^2$ light curing unit. The results were as follows : 1. Temperature in pulp increased as curing unit power is increased. 2. Temperature in pulp more increased continuous emission than intermittent emission.

  • PDF

양생 조건이 알칼리 활성 슬래그 기반 섬유보강 복합재료의 압축강도와 인장거동에 미치는 영향 (Effects of Curing Conditions on Compressive Strength and Tensile Behavior of Alkali-Active Slag-Based Fiber Reinforced Composites)

  • 박세언;최정일;이방연
    • 한국건설순환자원학회논문집
    • /
    • 제9권3호
    • /
    • pp.260-267
    • /
    • 2021
  • 이 연구의 목적은 양생조건이 물-결합재비가 15%인 알칼리 활성 슬래그 기반 복합재료의 압축 및 인장거동에 미치는 영향을 실험적으로 조사하는 것이다. 이를 위하여 양생 조건을 다르게 하여 실험체를 제작한 후 압축강도와 인장실험을 수행하였다. 실험 결과 고온 양생과 기중 양생을 적용함에 따라 매트릭스의 압축강도와 균열강도는 감소한 반면 인장변형성능은 증가하는 것으로 나타났다. 또한 고온 양생과 기중 양생을 통해 복합재료의 균열 간격과 균열폭이 감소하는 것으로 나타났다.

BTCA를 이용한 PVA 필름의 가교에 대한 연구 (Crosslinking of PVA Films with BTCA)

  • 윤성종;허용찬;장진호
    • 한국염색가공학회:학술대회논문집
    • /
    • 한국염색가공학회 2008년도 제38차 학술발표대회
    • /
    • pp.135-137
    • /
    • 2008
  • PVA films with 1,2,3,4-Butanetetracarboxylic acid(BTCA) and sodium hypophosphite monohydrate(SHM) were crosslinked via thermal curing. Different parameters affecting on the crosslinking were investigated including BTCA and SHM concentration, curing temperature and time. The cured films was extracted with boiling water and gel fraction was calculated from weight change of the PVA films. Moisture regain of the gelled films was also measured. While the gel fraction of PVA films increased with increasing curing temperature and time, moisture regain decreased. Water resistance of the crosslinked PVA films improved by the BTCA crosslinking treatment.

  • PDF

생황토와 플라이 애시를 혼입한 시멘트 모르타르의 공학적 특성 (Engineering Properties of Cement Mortar with Hwangtoh and Fly Ash)

  • 임성수;성찬용
    • 한국농공학회:학술대회논문집
    • /
    • 한국농공학회 2003년도 학술발표논문집
    • /
    • pp.395-398
    • /
    • 2003
  • This study is performed to evaluate the engineering properties of cement mortar with hwangtoh and fly ash The absorption ratio is in the range of $5.22{\sim}13.16%\;and\;8.53{\sim}13.29%$ at the curing age 14 and 28 days, respectively. The compressive strength is in the range of $92{\sim}458kgf/cm^2\;and\;88{\sim}316kgf/cm^2$ in water and dry cruing at the curing age 28days, respectively. The bending strength and dynamic modulus of elasticity are shown in similar tendency in water and dry curing.

  • PDF

규암 골재를 사용한 콘크리트 구조물의 재령에 따른 비파괴강도 추정식 (Prediction Formulas for Nondestructive Strength of Quartzite Aggregate Concrete)

  • 오병환;김동욱;이승석
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제5권2호
    • /
    • pp.137-146
    • /
    • 2001
  • The non-destructive tests are widely used to predict the strength of existing structures. The purpose of the present study is to propose the prediction equations for strength evaluation of concrete structures. The present study focuses on the rebound method and ultrasonic pulse velocity method for quartzite aggregate concrete. The major test variables include the water-cement ratio and curing methods. The water-cement ratio are 0.4, 0.5, 0.6, 0.7, respectively and the curing method covers ail-dry condition and standard curing condition. The prediction equations for strength of concrete are proposed from the present test data.

  • PDF

준설매립된 해성점성토에서 시멘트계 고화재를 이용한 표층개량 (The Improvement of Surface Layer Using Cement-hardening Agents in Dredged and Reclaimed Marine Clay)

  • 남정만;윤중만
    • 한국해양공학회지
    • /
    • 제18권4호
    • /
    • pp.46-51
    • /
    • 2004
  • The surface layer in dredged and reclaimed marine clay is improved by mixing of shallow soils and hardening agents, which is made of cement, containing some other special admixtures. Tests in both laboratory and field settings are performed to investigate the improvement effect and strength properties of cement-stabilized soils. The test results show that the hardening agent sufficiently improves the soil properties of the surface layer, while increasing the load-carrying capacity. The strength of cement-stabilized soils depends, primarily, on water-to-cement ratio and curing temperature. That is, the higher curing temperature and the longer curing time, the higher the strength in cement-stabilized soils. The high ratio of water-ta-cement results in a lower strength.