• Title/Summary/Keyword: Water control

검색결과 12,015건 처리시간 0.051초

WQV 기반 비점오염저감시설의 강우유출수 처리비 경험공식의 개선 (The Improvement on the Empirical Formula of Stormwater Captured Ratio for Water Quality Volume Based Non-Point Pollutants Water Quality Control Basins)

  • 최대규;박무종;박배경;김상단
    • 한국물환경학회지
    • /
    • 제30권1호
    • /
    • pp.87-94
    • /
    • 2014
  • According to the technical guideline of water pollutant load management, the rainfall captured ratio which can be estimated by the empirical formula is an important element to estimate reduction loads of non-point pollutants water quality control basin. In this study, the rainfall captured ratio is altered to stormwater captured ratio considering its meaning in the technical guideline of water pollutant load management, and the new empircal formula of stormwater captured ratio is suggested. In order to do this, we calculate stormwater captured ratio by using the hourly rainfall data of seven urban weather stations (Busan, Daegu, Daejeon, Gangreung, Seoul, Gwangju, and Jeju) for 43 years. The regression coefficients of the existed empirical formula cannot reflect the catchment properties at all, because they are fixed values regardless of regions. However the empirical formula of stormwater captured ratio has flexible regression coefficients by runoff coefficient(C), so it is allowed to consider the characteristics of runoff in catchment. It is expected that reduction loads of storage based water quality control basin can be more reasonably estimated than before.

심지형 저면관수시스템의 심지의 물리적 성질에 따른 수분흡수 특성 (Water Absorption Characteristics of Substrate with Physical Properties of wick in Subirrigation System Using wick)

  • Dong Ho Jung;Jung Eek Son
    • 한국생물환경조절학회:학술대회논문집
    • /
    • 한국생물환경조절학회 2001년도 봄 학술발표논문집
    • /
    • pp.41-42
    • /
    • 2001
  • The objectives of this study were to investigate the effect of the physical properties of wick on the water absorption of substrate. Physical properties of wick in this study were cotton composition, width and length. The water Infiltration rate through the wick was 0.24 ㎝/s at 90 -95% cotton content, which was faster than at 80-85% (0.13 cm/s) and 70-75% (0.08 cm/s). As the cotton content increased, the water absorption of substrate became greater : the amount of absorbed water was about 5-7g higher at 90-95% than at 80-85% and 70-75% at a wick width of 1 ㎝, the velocity of water absorption through the wick was fastest with 0.25 ㎝ㆍs/sup -1/. The amount of absorbed water was higher at 3 ㎝ than at 1 and 2 ㎝. However, the water absorption rate through the cross - sectional area of wick (g H₂O /㎠/hr) was higher at a wick width of 2 ㎝ than at those of 1 and 3 ㎝. The amount of absorbed water in the substrate was higher at 2 : 1 than at 1 : 1 (length in substrate : length out of substrate). Absorbed water amount was larger at 30-40% initial moisture content than any other treatment.

  • PDF

조력발전용 수차발전기의 기동·정지시스템에 관한 연구 (A Study on Start·Stop System at Water Turbine-Generator for Tidal Power Plant)

  • 오민환;박철원
    • 전기학회논문지P
    • /
    • 제63권2호
    • /
    • pp.113-118
    • /
    • 2014
  • Tidal power is one of new and renewable energy sources. Tidal power is generated by using the gap in the water level between the water outside and inside the embankment. All tidal power plant in Korea were being operated by import of turn-key from abroad. The know-how and technology which are the most important to build predictive control system has become increasingly difficult to obtain from advanced countries because most of them avoid to transfer, which the domestic development of the control system is needed. In this paper, a study on start stop system at water turbine-generator for tidal power plant at the beginning of development was presented. For improvement the efficiency and develope of core technology of the start stop system, the technique and characteristics of tidal power, modeling, maximum generation calculation method, and optimal control of joint control system in Sihwa tidal power plant were studied.

소수력 발전소의 무인화 구축 설계 (The Remote Control System Design of Small Hydropower Plants)

  • 이경배;김영태;백두현;이은웅
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 B
    • /
    • pp.950-952
    • /
    • 2004
  • The developments of small hydropower plants in korea have been delayed by rising construction cost/low feasibility, local people's disagreement even though the capacity of water resources are enough. However, the recent raising of electricity purchasing price, the government's enlarging plan of small hydropower plants caused the newly development to be accelerated. In this paper, the design of remote control of small hydropower plants are proposed for better economy and easy control. The operation and monitoring of power plants are planned based on One(1)-man control from the central control room of regional area water works/ operating station and engineering station multipurpose dam offices with the equipments of OS, RTU(PLC), KT leased lines, WMPS, CSU and etc.

  • PDF

퍼지추론을 이용한 수차 속도제어기 동조기법에 관한 연구 (A Study on Tuning Method of Turbine Speed Controller Using Fuzzy Inference)

  • 이정환;김운해;백두현;성기민;신강욱
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1993년도 하계학술대회 논문집 A
    • /
    • pp.316-318
    • /
    • 1993
  • In order to estimation the optimum PID parameter of the turbine speed controller, the response cure of the object plant was compared with the reference pattern and then the magnitude peak value error and peak time error was calculated. With the calculated errors as input into the Fuzzy inference Method was introduced to propose the tuning method for each parameter. And the computer simulation was performed with the above Fuzzy inference method in which the Chunju hydro power plant turbine governor system was used as a model. This Study also aims to develop the exclusive tuner for govenor using industrial computer.

  • PDF

베이지안 네트워크를 적용한 홍수 위험도 분석 (Application of Bayesian Networks for Flood Risk Analysis)

  • 선우우연;이길성;정은성
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 2012년도 학술발표회
    • /
    • pp.467-467
    • /
    • 2012
  • As the features of recent flood are spatially concentrated, loss of life and property increase by the impact of climate change. In addition to this the public interest in water control information is increased and socially reasonable justification of water control policy is needed. It is necessary to estimate the flood risk in order to let people know the status of flood control and establish flood control policy. For accurate flood risk analysis, we should consider inter-relation between causal factors of flood damage. Hence, flood risk analysis should be applied to interdependence of the factors selected. The Bayesian networks are ideally suited to assist decision-making in situations where there is uncertainty in the data and where the variables are highly interlinked. In this research, to provide more proper water control information the flood risk analysis is performed using the Bayesian networks to handle uncertainty and dependency among 13 specific proxy variables.

  • PDF

공동주택 세대별 난방 성능 개선 연구 (A Study on Improved Heating Performance of an Apartment Housing Unit)

  • 서정아;신영기;김용기;이태원
    • 설비공학논문집
    • /
    • 제28권2호
    • /
    • pp.69-74
    • /
    • 2016
  • Most hot water heating valves for apartments are constant-flow types, which limit the flow rate through an individual household for even distribution of heating water to other households. The constant-flow type is implemented by an on-off control. As a result, heating water is supplied intermittently and hence, indoor air temperature also fluctuates. Returning water temperature is also high, which reduces energy efficiency. To implement continuous feedback control, the indoor temperature dynamics was simulated to fit a measured temperature history by a state-of-the-art physical model. From the model, it was found that the most important disturbance is outdoor temperature and its effect on indoor temperature lasts about an hour. To cope with the slow response and the significant disturbance, a prediction control with proportional feedback is proposed. The control was found to be successful in implementing continuous heating water flow and improved indoor temperature control.

Control and Development of LonWorks Intelligent Control Module for Water Treatment Facility Based Networked control System

  • Hong, Won-Pyo;Kim, Dong-Hwa
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2003년도 ICCAS
    • /
    • pp.1757-1762
    • /
    • 2003
  • With distribution industrial control system, the use of low cost to achieve a highly reliable and safe system in real time distributed embedded application is proposed. This developed intelligent node is based on two microcontrollers, one for the execution of the application code, also as master controller for ensuring the real time control & the logic operation with PLD and other for communication task and the easy control execution, i.e., I/O digital input, digital output and interrupting. This paper also presents where the case NCS (Networked control system) with LonTalk protocol is applied for the filtration process control system of a small water treatment plant.

  • PDF

Investigation of present hygienic condition of rural area drinking water in Kunming 2004

  • Zhang, Liang;Wang, Xin;Liu, Xinhai
    • 한국환경보건학회:학술대회논문집
    • /
    • 한국환경보건학회 2004년도 International Conference Current Challenges and Advances in Environmental Health
    • /
    • pp.8-11
    • /
    • 2004
  • Objective To know about hygienic condition of drinking water in rural area of Kunming. Methods Selected 4 counties with different economy to investigate. In every county, according to the proportion, 10 drinking water spots were selected by randomization of lift drinking water'. Results In 4 areas, surface water for drinking is 82.41%, under water is 17.59%. And concentrated supply is 83.02% by populated proportion, others are 16.98%. 40 specimens qualification rate is 47.50%, and in it concentrated supply is 87.50%, others are 19.05%. Conclusion Unhealthy drinking water exist in most testing counties. Mainly microorganism isn't qualified. Concentrated management in drinking water is batter than other ways.

  • PDF

건설사업장의 수질관리 기술 적용사례 비교분석 (Comparative Analysis of Wastewater Management Technologies for Construction Sites)

  • 이종찬;구자건
    • KIEAE Journal
    • /
    • 제13권2호
    • /
    • pp.157-162
    • /
    • 2013
  • To deal with the water pollution arising from the construction site, this study raises the issues of management and laws and it suggest the efficient way to reduce water pollution by through the case studies. In order to study, seven cases were selected from "Construction Environmental Management Best Practice Competition" co - sponsored by Construction Association of Korea and Construction Environment Association. As a study result, there are problems that depending on the characteristic of the construction site environment simple alone settling facilities can not handle muddy and dirty water generated by the construction site. However, when the construction site applied improved water pollution control facilities with reflecting the characteristic of muddy and dirty water. The problem can be solved moreover it can achieve exceeded emission standard. Therefore new regulations and management with water pollution control facilities considering characteristic of environment is needed to cope with water pollution arising from the construction site.