• 제목/요약/키워드: Water contamination

검색결과 1,534건 처리시간 0.029초

Effects of Formic Acid Administration in the Drinking Water on Performance, Intestinal Microflora and Carcass Contamination in Male Broilers under High Ambient Temperature

  • Aclkgoz, Z.;Bayraktar, H.;Altan, O.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • 제24권1호
    • /
    • pp.96-102
    • /
    • 2011
  • In this study, we examined the effects of formic acid administration to the drinking water on performance, intestinal microflora and carcass contamination in male broilers. A total of 312 day-old male broiler chicks were allocated to two groups with three replicates. The first group (control) received normal drinking water (pH 7.4) during the experiment. The second group consumed acidified drinking water (pH 4.5) after 5 d of age. At 43 d of age, twelve birds were randomly selected from the control group to determine the effect of acidified drinking water on carcass contamination. These birds were only given normal or acidified (pH 3) drinking water for 8 h prior to slaughter. The reduction of water pH from 7.4 to 4.5 significantly decreased body weights of male broilers at 21 and 42 d of age. However, no differences were observed between male broilers given normal and acidified drinking water in terms of feed intake, feed conversion ratio and mortality. The pH value of the gizzard contents was not significantly affected by acid water treatment. There were no significant differences in the intestinal population of E. coli, total organism and Salmonella between the groups. The total organism and E. coli counts of the carcass slightly decreased in the acidified group. No Salmonella was identified in carcass samples of any of the treatment groups. The results showed that drinking water acidification did not provide beneficial effects on performance, intestinal microflora and carcass contamination in male broilers.

방사능 수치 오염 지도 작성을 위한 방사선 계측 시스템 연구 (Study of Radiation Mapping System for Water Contamination in Water System)

  • 나원경;김한수;연제원;이레나;하장호
    • 방사선산업학회지
    • /
    • 제5권2호
    • /
    • pp.185-189
    • /
    • 2011
  • As nuclear industry has been developed, a various types of radiological contamination has occurred. After 9.11 terror in U.S.A., it has been concerned that terrorists' active area has been enlarged to use nuclear or radioactive substance. Recently, the most powerful earth-quake stroke, which triggered a massive tsunami in Japan and then Fukushima nuclear power plant reactor has suffered from a serious accident in history. The Fukushima reactor accident has occurred an anxiety of radiation leaks and about 170,000 people have been evacuated from the accidental area near the nuclear power plant. For these reasons, a social chaos can be occurred if radiological contamination occurs to the supply system for the drinking water. As such, the establishment of the radiation monitoring system for the city main water system is compelling for the national security. In this study, a feasibility test of radiation monitoring system which consists of unified hybrid-type radiation detectors was experimented for multi detection system by using gamma-ray imaging. The hybrid-type radiation sensors were fabricated with CsI(Tl) scintillators and photodiodes. A preamplifier and amplifier was also fabricated and assembled with the sensor in the shielding case. For the preliminary test of detection of radiological contamination in the river, multi CsI(Tl)-PIN photodiode radiation detectors and $^{137}Cs$ gamma-ray source were used. The DAQ was done by Linux based ROOT program and NI DAQ system with Labview program. The simulated contamination was assumed to be occurred at Gapcheon river in Daejeon city. Multi CsI(Tl)-PIN photodiode radiation detectors were positioned at the Gapcheon river side. Assuming that the radiological contaminations flows in the river the $^{137}Cs$ gamma-ray source has been moved and then, the contamination region was reconstructed.

오봉댐 유역의 폐탄광에 의한 오염특성과 감소방안 연구 (Investigation on the Contamination of the Vicinity of Abandoned Coal Mines Located Near the Obong Darn and Preventive Measures)

  • 박선환;장윤영;정정호;손정호;박석효
    • 환경영향평가
    • /
    • 제16권2호
    • /
    • pp.143-156
    • /
    • 2007
  • This study has researched the management status and the pollution level of water, soil, stream sediments of 11 abandoned coal mines out of a total of 12 within Obong-Dam area except Bukyung mine, which was submerged when constructing Obong-Dam, and selected areas which are in needs to have pollution control facilities in the first place. From the results of examination on the runoff at the waste rock pile and mineheads, the runoff from Sueun mine (pH, Fe, Al), Samwon mine (pH, Al), Wangdo mine (pH, Al), Mose mine (pH, Fe, Al) and Daeryeong mine (pH) exceeded the permissible discharge standards of the water quality, but the water at merging point with Obong-Dam after joined with Doma branch satisfied both Water Quality Standards and Drinking Water Quality Standards. In regard to groundwater contamination, it is found that areas where exceeded the Drinking Water Quality Standards are Wangdo mine (pH), Jangjae mine (pH, Zn), Daeryeong mine (pH) whereas all areas satisfied Soil Contamination Warning Standards of Soil Environmental Conservation Law. When comparing a research result on underwater sediments of branches of abandoned mines to the EPA Guidelines for classification of great lakes harbor sediments, Dongguk Gaerim (Fe), Jungwon mine (Fe), Daebo mine (Mn), Samwon mine (Mn) and Daeryeong mine (Mn) showed mid-level of contamination, whereas Sueun (Fe, Mn), Daebo mine (Fe), Woosung mine (Fe, Mn), Wangdo mine (Fe, Mn), Mose mine (Fe) and Daeryeong mine (Fe) showed high-level of contamination. In addition, contamination levels of underwater sediments in Wangsan and Doma branch where abandoned mine's branches merge together, Wangsan branch showed no contamination at all whereas Doma branch shows mid-level of contamination which reflect the Doma branch is affected by waste rock pile and minehead runoff of the abandoned mines in the Doma branch area. It is concluded that Mose mine and Sueun mine required treatment of acid mine drainage. and Wangdo, Jungwon, and Samwon mines were in need of mine tailing and erosion control work. The Samwon mine additionally required a control system for closed minehead runoff. Although the Samwon mine reached a high concentration of Al, Mn $Ca^{2+}$, $SO{_4}^{2-}$ in the runoff, the levels decreased after it was combined with a tributary. It has been concluded that after further monitoring of the cause of pollution, a preventive measure system may be needed to be built.

대청호 상류유역 매립지의 침출수 분석 및 평가 (Assessment of Leachate from Solid Waste Landfills in Daechong Lake Upper Drainage Basin)

  • 홍상표
    • 환경영향평가
    • /
    • 제12권3호
    • /
    • pp.161-170
    • /
    • 2003
  • To investigate the characteristics of 17 solid waste landfills in the upper drainage basin of Lake Daechong, the landfill sites were surveyed, the leachate of these landfills were analyzed, and the analysis results were assessed from standpoint of water contamination. Sanitary landfills which are now being operated are relatively well equipped with facilities such as leachate collection, daily soil cover and landfill gas treatment devices. But a few of open-dumping landfills were leaking leachate apparently and were supervised improperly and neglectfully by local governments. Some of sanitary landfills exceeded the COD permission criteria of leachate effluent, and some of open-dumping landfills exceeded SS, T-P, Pb, As, Fe, Mn permission criteria of leachate effluent. To improve the water quality of Lake Daechong which is utilized for supplying drinking water, agricultural water, and industrial water to the great part of Chungchong area, the adequate and prompt measures for preventing Daechong Lake water contamination from landfills leachate is necessary.

우리나라의 환경문제 우선순위 도출 - 환경전문가를 중심으로 - (The Priority of Environmental Problems in Korea)

  • 신동천;임영욱;박종연;장은아;김진용;박성은;조성준
    • Environmental Analysis Health and Toxicology
    • /
    • 제14권4호
    • /
    • pp.165-174
    • /
    • 1999
  • This study was conducted to analyze the priority of environmental problems in Korea by investigating the environmental professionals' perception. The delphi technique was applied to identify their risk perception towards some specific items related with pollution. A standardized questionnaire on environmental problems and their priorities was used to 74 subjects. In the questionnaire, the environmental problems were divided into the general ones,9 items, and the specific ones,30 items. Also, the perception was associated with two points of view which were the risk on general human health or ecosystem, and on the present situation in Korea. The priority of risk from general environmental problems on human health or ecosystem was analyzed in the order of 'water pollution', 'air pollution', 'soil contamination', 'waste', 'toxic chemical pollutants', 'food contamination', 'ocean contamination', 'odor pollution', and 'noise pollution'. The priority of risk on the present situation in Korea was analyzed in the order of 'water pollution','air pollution','waste','toxic chemical pollutants','food contamination','soil contamination','ocean contamination','odor pollution', and 'noise pollution'. And these priorities were significantly related with the characteristics of respondents such as sex, age, and major concerned area. However, for the first five priorities of risk from the specific environmental problems on human health or ecosystem, the environmental professionals agreed with 'automotive vehicle exhaust', 'domestic and industrial source pollutants to surface water', '$CO_2$nd g1oba1 warming effect','toxic air pollutant' and 'industrial source air pollution'. The priorities of risk on the present situation in Korea were similar to these results.

  • PDF

도재소부전장금관용 합금과 용액의 오염이 기포발생에 미치는 영향에 관한 실험적 연구 (AN EXPERIMENTAL STUDY ON THE PORCELAIN POROCITY EXERTED BY THE CONTAMINATION OF THE CERAMO-METAL ALLOY AND LIQUID)

  • 전영찬;이호용
    • 대한치과보철학회지
    • /
    • 제20권1호
    • /
    • pp.33-49
    • /
    • 1982
  • This study was undertaken to observe the porcelain porosity exerted by the contamination of the alloy and liquid. The alloy used in this study was Jelstar; liquids were Ceramco Sta-Wet liquid, distilled water and tap water; and Ceramco vacuum porcelain powder was used. The measurements with photomicroscope (x200, Olympus) were made on the porosity, the diameter (mm) of the pores and the numbers of the pores ($No/mm^2$) The results of this study were obtained as follows: 1. In the porosity, the opaque layer contained over 70% of the total porosity, and the porosity was increased about twice in every porcelain layer by the tap water. 2. The contamination of the alloy and liquid caused porosity to increase markedly at the interface of the metal-porcelain. 3. The diameter of the pores were increased about 1.5 times larger by the contaimination of the liquid, and only a slight increase in the opaque layer due to the contamination of the alloy. 4. In the numbers of the pores, there were significant differences according to the contamination of the alloy and the porcelain layer. And the contamination of the liquid caused significant differences only in the opaque layer.

  • PDF

한국의 상황과 비교한 네팔의 수질 관련 현재의 문제 및 향후 과제 (Current Issues and Challenges Related to Water Quality of Nepal in Comparison with Korean Situation)

  • 프러티바 반다리;김동수
    • 한국물환경학회지
    • /
    • 제27권1호
    • /
    • pp.1-8
    • /
    • 2011
  • 네팔의 천연 수자원은 풍부한 편이나 모든 인구가 안전하고 깨끗한 식수를 공급받고 있지는 못한 상황이다. 또한, 폐수 처리에 대한 상황 역시 매우 열악한 상태라고 할 수 있다. 최근, 도시로의 인구 유입이 증가함에 따라 안전한 물의 공급 및 공중 위생에 대한 관심이 증대되고 있으나, 수인성 질환의 발병률은 여전히 높은 상황이다. 본 논문에서는 네팔의 수질 오염, 식수에서의 비소 오염, 폐수 처리, 그리고 대중의 건강에 대한 수질 오염의 영향 등에 대해 검토하였다. 또한, 폐수 처리와 연관된 규제와 관련하여 한국의 상황과 비교하여 양국의 상황을 비교 고찰하였다. 이러한 내용들에 의거하여 대중의 건강 증진을 위한 현존 문제점들의 해결 방안들을 제시하였다.

통계적 기법을 이용한 광주지역 민방위비상급수용 지하수 수질 오염도 분석 및 시각화 연구 (Visualization and contamination analysis for groundwater quality of CDEWSF in Gwangju area using statistical method)

  • 장서은;이대행;김종민;김하람;정숙경;배석진;조영관
    • 분석과학
    • /
    • 제31권3호
    • /
    • pp.122-133
    • /
    • 2018
  • 본 연구에서는 광주지역 민방위비상급수시설 101 개소를 대상으로 2006년부터 2016년까지 11년 동안 측정한 지하수 수질자료를 통계적으로 분석하였으며, 각 시설별로 먹는물 수질기준 초과횟수와 평균농도 분석 및 경향성 분석을 실시하고, 그 분석결과를 이용하여 4 개의 오염등급으로 구분하였다. 또한 이를 바탕으로 토지이용 현황별로 각 항목의 지하수 오염도를 평가하였다. 통계적으로 유의한 민방위 비상급수 15 개 항목에 대한 수질기준초과횟수, 평균농도분석, 경향성분석의 세가지 오염지시인자를 분석하여 합산한 결과 Turbidity (51.5 %) > Color (32.7 %) > Nitrate nitrogen (28.7 %) > Hardness (25.7 %) 순으로 오염 지시율이 상대적으로 높게 평가되었다. 오염등급 분석결과 안전(0)부터 오염심각(3)까지 오염등급이 다양하게 분포한 Turbidity, Color, Nitrate nitrogen의 3 개 항목을 제외하면 12 개 항목의 수질 오염등급은 전체의 25 %는 '오염가능한 등급(1)'으로, 75%는 '안전한 등급(0)'으로 평가되었다. QGIS를 이용하여 오염 지시율이 높게 평가된 4 개 항목(Turbidity, Color, Nitrate nitrogen, Hardness)은 오염지도에 작성하여 오염등급을 시각화하였다.

고분자 전해질막 수전해 막전극접합체의 양이온 오염에 따른 성능 저하 (Performance Degradation of Mea with Cation Contamination in Polymer Electrolyte Membrane Water Electrolysis)

  • 정혜영;최낙헌;임수현;윤대진;문상봉
    • 한국수소및신에너지학회논문집
    • /
    • 제28권4호
    • /
    • pp.331-337
    • /
    • 2017
  • Proton Exchange Membrane Water Electrolysis (PEMWE) is one of the most popular and widely used methods for hydrogen production. PEMWE contributes to eco-friendly system via its energy storage system application, hence making it environmentally friendly to use. However, its main drawback is contamination of proton exchange membrane during water electrolysis. Existing cation such as magnesium, calcium and the likes are the cause for membrane contamination. As a result, the cation contamination give rise to degradation of performance of electrolysis and the reverse electrolysis is effective method to remove cation.

금정광산 주변 토양의 중금속 오염현황 및 그 처리 방안

  • 이기철;이승길;한인호;최광호;정덕영
    • 한국지하수토양환경학회:학술대회논문집
    • /
    • 한국지하수토양환경학회 1998년도 공동 심포지엄 및 추계학술발표회
    • /
    • pp.189-194
    • /
    • 1998
  • Geochemical study was carried out to find out the distribution of metals and cyanide in soil in the vicinity of the abandoned Keum-Jung mine. Chemical analysis showed that content of As in soil around tailings exceeded 15mg/kg, Korean standard of soil contamination in the farm land. That means the contamination of soil by As is due to input of tailings. According to total decomposition of tailings, As was highly concentrated in tailings. However the water in tailings impoundment was changed to acidic and contaminated by metal and sulfate because the tailings in the top of the tailings impoundment had been oxidized. Acid mine drainage contaminated the water course in the vicinity of the paddy soils. The proper measures are required to prevent contamination of the soil and water in the vicinity of the Keum-Jung mine.

  • PDF