• Title/Summary/Keyword: Water and wastewater treatment facilities

Search Result 181, Processing Time 0.031 seconds

Treatment of residues of excavated carcasses burials (가축매몰지 소멸시 잔존물 처리방안)

  • Kim, Geonha
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.32 no.3
    • /
    • pp.269-277
    • /
    • 2018
  • Burials for the rapid disposal of carcasses have diverse and profound effects on the rural living condition, natural environment, and local economy throughout construction, management and final destruction of burials. In this study, possible residue excavated from standard burials, storage using FRP (Fiberglass Reinforced Plastic) tanks, and microbial-treated burials are characterized as carcasses, contaminated soil by leachate, and wasted plastic film. Treatment technologies for volume reduction of the residue including composting, rendering, and thermal hydrolysis were investigated. If the solid and liquid residues generated during volume reduction treatment are directly transferred to the environmental facilities, it may cause disorder due to high concentrations of organics, antibiotics, and lipid. Benefits and drawbacks of composting as a volume reduction techniques are extensively investigated. We also discussed that proper treatment of excavated soils and the reusing the treated soil as agricultural purpose. For the protection of public health and worker's hygiene, treatment criteria including produced residue qualities, and quality standards for the treated soil as agricultural use are required. In addition, Scientific manual for the proper treatment of residues is required. It is necessary to consider the establishment of a pretreatment facility to the occurrence of large-scale residue treatment.

Quality Assessment of the Nationwide Water Pollution Source Survey Results on the Prioritized Toxic Water Pollutants from Industrial Sources in the Geum-River Basin by Exploratory Data Analysis (금강유역 산업계 특정수질유해물질 배출현황에 대한 탐색적 데이터 분석을 통한 전국오염원조사 결과 적합성 평가)

  • Kim, Eun-Ah;Kim, Yeon-Suk;Kim, Yong Seok;Rhew, Doug Hee;Jung, Je Ho
    • Journal of Korean Society on Water Environment
    • /
    • v.30 no.6
    • /
    • pp.585-595
    • /
    • 2014
  • The temporal trends of the prioritized toxic water pollutants generated and discharged from the industrial facilities in the Geum-River basin, Korea were analyzed with the results of the nationwide Water Pollution Source Survey conducted in 2001 - 2012. The statistical results indicated rapid increase in the volume of raw toxic wastewaters whereas the amount of each toxic pollutant kept fluctuating for 12 years. Serious discrepancies in the survey data of the same type of industries demonstrated a low reliability of the survey result, which stemmed from several error factors. A unit-load for each type of industrial facility was devised to estimate the amount of prioritized toxic water pollutant based on the total volume of industrial wastewater generated from the same type of industrial facilities. The supplementary measures with an effective permit issuance policy and adding survey parameters of terminal wastewater treatment plants to use them as references to the Water Pollution Source Survey were suggested as means to minimize the errors associated with the false reports from the industries.

Acute Toxicity Test for Wastewater from Several Drainage Canals and Discharges Using Daphnia Magna (생태독성도를 이용한 공단배수 및 공장배출수의 독성도 조사)

  • Park, Dong-Gyu;Bae, Hun-Kyun
    • Journal of Environmental Science International
    • /
    • v.20 no.7
    • /
    • pp.811-818
    • /
    • 2011
  • Daphnia Magna Stratus has been widely accepted as useful species for estimating the toxicity of chemicals to aquatic invertebrate and recommended as species for the testing chemicals from the international guideline as well as Korean guideline. The study was performed for the acute toxicity test by using water flea(D. Magna) for effluents from several wastewater treatment plants and drainage canals in GyeongBuk area. Five heavy metals, 1,4-Dioxane and Perchlorate were tested. Most Toxicity Units(TU) of Industrial wastewater effluents were less than 1 which means effluent was not toxic to D. Magna. However, effluents containing 1,4-Dioxane and Perchlorate were significantly toxic to D. Magna. Therefore, facilities should reduce the 1,4-dioxane since new regulations will force them after the year of 2011.

Elution characteristics of lime-based granular alkaline material and applicability of phosphorus crystallization processes (석회계 입상알칼리재의 용출특성과 이를 이용한 인 결정화공정의 적용성)

  • Chang, Hyang-Youn;Park, Na-Ri;Jang, Yeo-Ju;Ahn, Kwang-Ho;Lim, Hyun-Man;Kim, Weon-Jae
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.31 no.6
    • /
    • pp.577-586
    • /
    • 2017
  • One of the major sources causing eutrophication and algal blooms of lakes or streams is phosphorus which comes from point and nonpoint pollution sources. HAP (hydroxyapatite) crystallization using granular alkaline materials can achieve the decrease of phosphorus load from wastewater treatment plants and nonpoint pollution control facilities. In order to induce HAP crystal formation, continuous supply of calcium and hydroxyl ions is required. In this research, considering HAP crystallization, several types of lime-based granular alkaline materials were prepared, and the elution characteristics of calcium and hydroxyl ions of each were analyzed. Also, column tests were performed to verify phosphorus removal efficiencies of granular alkaline materials. Material_1 (gypsum+cement mixed material) achieved the highest pH values in the column tests consistently, also, Material_2 (gypsum+slag mixed material) and Material_3 (calcined limestone material) achieved over pH 9.0 for 240 hours (10 days) and proved the efficiencies of long-term ion supplier for HAP crystallization. In the column tests using Material_3, considerable pH increase and phosphorus removal were carried out according to each linear velocity and filtration depth. T-P removal efficiencies were 87.0, 84.0, 68.0% and those of PO4-P 100.0, 97.0, 80.0% for linear velocity of 1.0, 2.5, 5.0 m/hr respectively. Based on the column test results, the applicability of phosphorus removal processes for small-scale wastewater treatment plants and nonpoint pollution control facilities was found out.

The Development and Application of the Performance Indicator for Sewage System Service in Korea (하수도서비스 평가지표 개발 및 적용에 관한 연구)

  • Ahn, Young Mi;Kim, Duk-Jin;Yoon, Hyun Shik;Kim, Young Jo;Yoo, Man Sik
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.21 no.4
    • /
    • pp.453-465
    • /
    • 2007
  • With rapid expansion of the water market and growth of water companies, the recent trends in international water industry show that standardization of service activities concerning management of water and wastewater system (ISO/TC 224, to be issued in the second half year of 2007) is expected to have a large influence on the global water market including liberalization of water service market. In the Draft International Standard(DIS) of ISO/TC224, Performance Indicators(PIs) are suggested to estimate the service activities relating to water and wastewater treatment facilities. PIs have been developed in many countries including some international organization(World Bank, IWA and etc.) for service benchmarking. To evaluate public service level and establish plans to improve service level of wastewater utilities, we developed PIs for 120 items and applied them to 10 sewage utilities in the consideration of their scales, circumstances and conditions. In this study, we verified the applicability of the developed performance indicators(PIs). So, we concluded that PIs developed for the purpose of this study can be a useful tool applicable to objective evaluation of the service level of sewage utilities. Using the evaluation tool of PIs developed, it can also be used as a benchmarking tool in this industry as well as for enhancing the efficiency of operation and management of the sewage system. It will also contribute to the water resource management through determination of investment priorities based on the evaluation results and to raising international competitiveness of the domestic sewage utilities to meet the future opening of the water market.

Effect Analysis on Self-supporting Energy of Newtown Sewage Treatment Facility for Low-carbon Green City (저탄소 녹색도시 조성을 위한 신도시 하수처리시설의 에너지 자립 효과 분석)

  • Ahn, Soo-Jeung;Hyun, Kyoung-Hak;Kim, Jong-Yeob;Choung, Youn-Kyoo
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.24 no.6
    • /
    • pp.683-690
    • /
    • 2010
  • Renewable and unutilized energy (biogas power generation, wind power, solar, small hydro-power, sewage heat source, etc.) seems to be suitable to install for the sewage treatment facilities. There are 357 sewage treatment plants in 2007. 17 plants among these have been operating for self-supporting energy by using solar power, small hydro-power and biogas in 2008. Newly built sewage treatment plant of 96,000 $m^3$/day for a newtown is expected to get up to energy consumption of 10 GWh/yr. If solar energy, small hydro-power and biogas-equipments were applied to the new treatment plant, self-supporting energy of the new sewage treatment plant will get up to 56.1%. As a results, about 2,379ton $CO_2$/yr $CO_2$ emission reduction can be expected by using renewable energy. These efforts for self-supporting energy will lead sewage treatment plant to new energy recycle center.

Study on the characterization of dissolved organic matters by XAD resin fractionation (XAD 수지분획에 의한 용존유기물질 특성 연구)

  • Park, Jeong-Min;Heo, Seong-Nam;Im, Tae-Hyo;Shin, Chan-Ki
    • Journal of environmental and Sanitary engineering
    • /
    • v.22 no.4
    • /
    • pp.23-32
    • /
    • 2007
  • Changes in the characteristics of dissolved organic matter was studied at selected stations in the Nakdong river basin using physical and chemical methods. Characteristics of dissolved organic matters were analysed and assessed. Production of disinfection byproducts were also investigated. Distribution of the organic compounds according to the Molecular weight(MW) indicate that MWs higher than 100K were highest with cattle excrement wastewater and MW between 100-10K were highest with waters from forest streams. Low MW compounds (Jess than 1K) were highest with the effluents from environmental facilities. Results of resin fractionation study show that acidic hydrophobic substances(AHS) were dominant in many stations. The values were higher in the samples from mainstreams and sidestreams where the influence of organic matter is higher than the water from environmental facilities. Hydrophilic neutral substances(HoN) such as hydrocarbon, pesticides and detergents were higher in the wastewater treatment facilities. HoN values of water from the forest streams were 4.7% indicating there is no synthetic pollutant.

A Treatment Efficiency of Wastewater by using Sym-Bio Process and Dissolved Ozone flotation Process for Water Reuse (하수처리수 재이용을 위하여 Sym-bio공정과 용존 오존 부상공정을 이용한 하수처리의 효율 분석)

  • Park, Changyu;Park, Jaehan;Lee, Kyunghee;Ahn, Yoonhee;Ko, Kwangbaik;Jung, Hyuncheol
    • Journal of Korean Society on Water Environment
    • /
    • v.24 no.1
    • /
    • pp.86-90
    • /
    • 2008
  • Water reuse of effluent is limited, due to bacteria and chromaticity or turbidity which may result in low perception of water quality. Consequently, this study showed a method in the reuse of treated wastewater by a diversified treatment method, with separation of centralized reformation of aeration tank into pre-treatment with minimum installation of facilities, and post-treatment, applying advanced oxidation treatment. A pilot plant experiment was performed using Sym-Bio process adopting an NADH Sensor without modification of the exiting aeration tank. The Dissolved Ozone Flotation process, which is an advanced oxidation process, to treat the remaining organics, nutrients, chromaticity, turbidity and bacteria. As a result in the Sym-Bio process, the biological treatment, even on the condition of single stage reaction tank, the treatment efficiencies of BOD, $COD_{Mn}$, $COD_{Cr}$, SS and T-N were 96.6%, 84.6%, 88.25%, 95.1% and 71.0%, respectively, while that for T-P was 25.0%, which required further treatment. In the Dissolved Ozone Flotation process, the advanced oxidation treatment, the treatment efficiencies of BOD, $COD_{Mn}$, $COD_{Cr}$, SS, T-N, T-P, chromaticity, turbidity, bacteria, coliforms were 78.9%, 34.6%, 28.7%, 48.0%, 70.4%, 82.4%, 84.0%, 74.5%, 99.8% and 99.4%, respectively.

Operating Conditions for Minimization of DBPs (Disinfection by-Products) in Drinking Water Supply System (소독부산물 최소화를 위한 운영조건 연구)

  • Shin, Hyung-Soon;Choi, Phil-Kweon;Kim, Jong-Su;Choi, Ill-Woo;Kim, Sang-Hoon;Kim, Tae-Hyun;Lee, Kyung-Hee;Lee, Soo-Moon;Jang, Eun-Ah;Jung, Yeon-Hoon;Kim, Jung-Yeol
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.19 no.3
    • /
    • pp.330-337
    • /
    • 2005
  • This study was carried out to propose the managemental improvement of the purification plants and the distribution facilities which can minimize the formation of disinfection by-products in drinking water distribution system. The disinfection by-products were highly created in the water treatment plant that the organic matters were high and the chlorine dosage was excessive. The concentration of DSPs was shown the highest value in August and the lowest value in December, because of temperature and pre-chlorine dosage effect. From the result of tracer test, the travel time from the treatment plant to the end of pipeline was around 3-4 days in summer, 5-6 days in winter, respectively, and the DSPs concentration of the reservoir(end of pipe) was 2-3 times higher than that of the beginning point. The improvement of the chlorination process and structural reformation of distribution facility was demanded to minimize the DSPs increase from purification plant to the end of pipe.

Determination of the Optimal Location for Water Treatment Plants in the Decentralized Water Supply System (분산형 용수공급시스템 구축을 위한 정수처리시설 최적 위치 결정)

  • Chang, Dong-Eil;Ha, Keum-Ryul;Jun, Hwan-Don;Kim, Jeong-Hyun;Kang, Ki-Hoon
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.27 no.1
    • /
    • pp.1-10
    • /
    • 2013
  • Major issues in water supply service have changed from expansion of service area to improvement of service quality, i.e., water quality and safety, and early response to emergency situation. This change in the service concept triggers the perceptions of limitation with the current centralized water supply system and of necessities of decentralized (distributed) water supply system (DWSS), which can make up the limitations. DWSS can reduce the possibility of water supply outage by establishing multiple barriers such as emergency water supply system, and secure better water quality by locating treatment facilities neighboring consumers. On the other hand, fluctuation of water demand will be increased due to the reduced supply area, which makes difficult to promptly respond the fluctuating demand. In order to supplement this, hybrid water supply system was proposed, which combined DWSS with conventional water supply system using distributing reservoir to secure the stability of water supply. The Optimal connection point of DWSS to existing water supply network in urban area was determined by simulating a supply network using EPANET. Optimal location of decentralized water treatment plant (or connection point) is a nodal point where changes in pressure at other nodal points can be minimized. At the same time, the optimal point should be selected to minimize hydraulic retention time in supply network (water age) to secure proper water quality. In order to locate the point where these two criteria are satisfied optimally, Distance measure method, one of multi-criteria decision making was employed to integrate the two results having different dimensions. This methodology can be used as an efficient decision-support criterion for the location of treatment plant in decentralized water supply system.