• Title/Summary/Keyword: Water and Heat Transport

Search Result 185, Processing Time 0.026 seconds

The Seasonal Variation of the Heat Budget in Deukryang Bay (득량만의 열수지 계절 변동)

  • 주용환;조규대
    • Journal of Environmental Science International
    • /
    • v.7 no.1
    • /
    • pp.67-73
    • /
    • 1998
  • Surface heat budget of the Deukryang Bay from July 1, 1992 to September 12, 1993 is analyzed by us- ing the meteorological data (by Changhung Observatory and Mokpo Meteorological Station) and oceanogaphical data (by Research Center for Ocean Industrial Development. Pukyong National University). Each flux element at the sea surface which has annual variation Is derived with application of an aerodynamical bulk method and empirical formulae. The solar radiation Is the maximum In spring and sensible heat are the maximum in autumn and water. and minimum in summer The heat .storage rate is calclilated by using the rate of water temperature variation according to the depth. The oceanic transport heat is estimated as a residual. The net heat flux, the heat storage rate are positive In spring and summer, while they are negative in autumn and winter. The oceanic transport heat Is convergence In winter and divergence In the rest of seasons.

  • PDF

Daily Variation of Heat Budget Balance in the Gangjeong-Goryung Reservoir for Summertime - Concerning around the Rate of Heat Storage - (낙동강 강정고령보의 여름철 열수지 일변화 - 열 저장량 변동을 중심으로 -)

  • Kim, Seong-Rak;Cho, Chang-Bum;Kim, Hae-Dong
    • Journal of Environmental Science International
    • /
    • v.24 no.6
    • /
    • pp.721-729
    • /
    • 2015
  • Surface heat balance of the Gangjeong-Goryung Reservoir is analyzed for 12-17 August 2013. Each flux elements at the water surface is derived from the special field observations with application of an aerodynamical bulk method for the turbulent heat fluxes and empirical formulae for the radiation heat fluxes. The rate of heat storage in the reservoir is estimated by using estimated by surface heating rate and the vertical water temperature data. The flux divergence of heat transport is estimated as a residual. The features of the surface heat balance are almost decided by the latent heat flux and the solar radiation flux. On average for 12-17 August 2014 in the Gangjeong- Goryung Reservoir, if one defines the insolation at the water surface as 100 %, 94 % is absorbed in the reservoir; thereafter the reservoir loses about 30~50% by sensible heat, latent heat and net long-wave radiation. The residue of 50~80 % raises the water temperature in the reservoir or transported away by the river flow during the daytime.

Development of a Multi-Physics Model of Polymer Electrolyte Membrane Fuel Cell Using Aspen Custom Modeler (Aspen Custom Modeler를 이용한 고분자전해질 연료전지 다중 물리 모델 개발)

  • SON, HYEYOUNG;HAN, JAESU;YU, SANGSEOK
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.32 no.6
    • /
    • pp.489-496
    • /
    • 2021
  • The performandce of polymer electrolyte membrane fuel cell depends on the effective management of heat and product water by the electrochemical reaction. This study is designed to investigate the parametric change of heat management along the channel of polymer electrolyte membrane. The model was developed by an aspen custom modeler that it can solve differential equation with distretization model. The model can simulate water transport through the membrane electrolyte that is coupled with heat generation. In order to verify the model, it is compared with the experimental data. The water transport behavior is then evaluated with the simulation model.

Establishment of calculation methodology and thermal analysis for the development of a water calorimeter

  • Kang, M.Y.;Kim, Junhyuck;Choi, H.D.
    • Nuclear Engineering and Technology
    • /
    • v.52 no.11
    • /
    • pp.2620-2629
    • /
    • 2020
  • As an early stage in the development of a water calorimeter, this study established a computer simulation methodology for analyzing the thermal behavior of a water calorimeter based on radiation transport and energy deposition. As a result, this study developed a method wherein the energy deposition distribution, which is obtained by applying Monte Carlo methods in water calorimeters, is directly used as a heat source for the thermal analysis model. Based on the proposed method, heat transfer in a water vessel and the effect of thermistor self-heating were analyzed. Through an analysis of the water velocities with and without a water vessel, it was found that a water vessel can serve as a convection barrier. Furthermore, it was confirmed that when considering thermistor self-heating, the water temperature change at the thermistor location is 0.219 mK higher compared to that when the thermistor was not considered. Therefore, thermistor self-heating must be considered to analyze the thermal behavior of a water calorimeter more accurately.

VALIDATION OF A DESIGN CODE FOR SODIUM-TO-SODIUM HEAT EXCHANGERS BY UTILIZING COMPUTATIONAL FLUID DYNAMICS (전산유체역학을 이용한 소듐-소듐 열교환기 설계코드의 검증)

  • Kim, D.;Eoh, J.H.;Lee, T.H.
    • Journal of computational fluids engineering
    • /
    • v.21 no.1
    • /
    • pp.19-29
    • /
    • 2016
  • A Prototype Gen-IV Sodium-cooled Fast Reactor which is one of the $4^{th}$ generation nuclear reactors is in development by Korea Atomic Energy Research Institute. The reactor is composed of four main fluid systems which are categorized by its functions, i.e., Primary Heat Transport System, Intermediate Heat Transport System, Decay Heat Removal System and Sodium-Water Reaction Pressure Relief System. The coolant of the reactor is liquid sodium and sodium-to-sodium heat exchangers are installed at the interfaces between two fluid systems, Intermediate Heat Exchangers between the Primary Heat Transport System and the Intermediate Heat Transport System and Decay Heat Exchangers between the Primary Heat Transport System and the Decay Heat Removal System. For the design and performance analysis of the Intermediate Heat Exchanger and the Decay Heat Exchanger, a computer code was written during previous step of research. In this work, the computer code named "SHXSA" has been validated preliminarily by computational fluid dynamics simulations.

Theoretical Analysis of Heat Transport Limitation in a Screen Mesh Wick Heat Pipe

  • Lee, Ki-Woo;Park, Ki-Ho;Lee, Wook-Hyun;Rhi, Seok-Ho
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.12 no.1
    • /
    • pp.1-9
    • /
    • 2004
  • The purpose of the present study is to examine the heat transport limitations in a screen mesh heat pipe for electronic cooling by theoretical analysis. Diameter of pipe was 6mm, and mesh numbers were 50, 100, 150, 200 and 250, and water was investigated as working fluid. According to the change of mesh number, wick layer, inclination and saturation temperature, the maximum heat transport limitations by capillary, entraintment, sonic and boiling were analyzed by a theoretical design method of heat pipe, including capillary pressure, pumping pressure, liquid friction coefficient in wick, vapor friction coefficient, etc. Based on the results, the capillary limitation in a small diameter of heat pipe is largely affected by mesh number and wick layer. Mesh number of 250 is desirable not to be used in pipe diameter of 6 mm, because capillary heat transport limitation decreases by the abrupt increase of liquid friction pressure due to the small liquid flow area. For the heat transport of 15 watt in 6mm diameter pipe, mesh number of 100 and one layer is an optimum wick condition, which thermal resistance is the smallest.

Performance Analysis of Mechanical Face Seal Used for Primary Heat Transport Pump in Heavy Water Reactor (중수로 냉각재 펌프용 미케니컬 페이스 실의 성능 해석)

  • Kim, Jeong-Hun;Kim, Dong-Wook;Kim, Kyung-Woong
    • Tribology and Lubricants
    • /
    • v.27 no.5
    • /
    • pp.240-248
    • /
    • 2011
  • Mechanical face seal installed in primary heat transport pump used for heavy water reactor prevents leakage of working fluid using thin working fluid film between primary seal ring and mating ring. If the leakage of working fluid exceeds the allowable volume, serious accident can be happened by the trouble of primary heat transport pump. The thinner fluid film exists between primary seal ring and mating ring, the less working fluid leaks out. On the other hand, if the thickness of fluid film is not enough, the life of mechanical face seal will be reduced by friction and wear. Therefore appropriate design is necessary to maximize the performance and life of mechanical face seal. In this study, numerical analysis using finite volume method was conducted to investigate the performance of mechanical face seals which have same deep straight groove and 11 different net coning values. As results, equilibrium clearance between primary seal ring and mating ring, leakage volume of working fluid, friction torque on sealing surface and stiffness of working fluid film were obtained. With increasing net coning value, equilibrium clearance and leakage volume increase, and friction torque and stiffness of fluid film decrease.

An experimental study on the effects of an inserted coil on flow patterns and heat transport performances for a horizontal rotating heat pipe (수평 회전 히트파이프에서 내부 삽입 코일이 유동 형태 및 열전달 성능에 미치는 영향에 대한 실험 연구)

  • 이진성;김철주;김선주;문석환
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.10 no.6
    • /
    • pp.763-772
    • /
    • 1998
  • The effects of an inserted coil on flow patterns and heat transport performance for a horizontal rotating heat pipe have been studied experimentally. Especially, the present study is to see an internally inserted helical coil inside a RHP would lead to the same kind of results as internal fins. Visualization test conducted for an acryl tube, charged water with at a volumetric rate of 20%. When the flow kept pool regime at a low RPM(less than 1,000 RPM), the movement of coil forced the water to flow in axial direction. But this pumping effect of coil disappeared, when the pool regime changed to annular one which could be created by increasing RPM. The pumping effects for RHP with an inserted coil resulted enhancement both in condensation heat transfer coefficient and heat transport limitation, as obtained in case of using internal fins. But all these effects became negligible in the range of higher RPM(above 1,000∼1,200) with the transition of flow regime to annular flow.

  • PDF

Comparison of the Heat transport Limitations for Screen Mesh Wick and Sintered Metal Wick Heat Pipes by Theoretical Analysis (이론적 해석에 의한 스크린 메쉬윅과 소결윅 히트파이프의 열수송 한계 비교)

  • Kim Keun-Bae;Kim Yoo
    • Journal of Energy Engineering
    • /
    • v.13 no.4
    • /
    • pp.267-274
    • /
    • 2004
  • Theoretical analysis for predicting the heat transport limitations of screen mesh wick and sintered wick heat pipes was performed. The heat pipe diameter was 8mm and water was used for working fluid. For the 250 mesh, each capillary pressures and heat transport limitations, thermal resistances were analyzed according to the operating temperatures, wick thicknesses and inclination angles, based on the effective capillary radius (r$\_$c/), porosity ($\varepsilon$) and permeability (K). The wick capillary limitation was increased as the operating temperature and the wick thickness were increased, and generally the sintered wick showed higher heat transport limitations than that of the screen wick. The thermal resistance of the screen wick was higher than that of the sintered wick and both thermal resistances were linearly increased as the wick thickness was increased.

Characteristics of High Water Temperature Occurrence in Coastal and Inland Bays of Korea during the Summers of 2018-2021 (2018년~2021년 여름철 우리나라 연안 고수온 현상)

  • Lee, Joon-Soo;Kwon, Mi-Ok;Ahn, Ji-Suk;Park, Myung-Hee;Song, Ji-Yeong;Han, In-Seong;Jung, Rae Hong
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.28 no.5
    • /
    • pp.753-763
    • /
    • 2022
  • In coastal and inland bays, where most of Korea's aquaculture is located, massive aquaculture damage occurs every year due to frequent anomalous high water temperatures. The interannual fluctuations of water temperature in July over the past four years (2018-2021) were the second largest since 1990 (after the period of 1994-1997) due to anomalous high temperatures, rainy seasons, and typhoons. Through analysis of heat flux and heat balance in areas of concern for high water temperatures (i.e., Cheonsu Bay, Gamak Bay, Guryongpo), the occurrence of high water temperatures in Cheonsu Bay and Gamak Bay in the summer seasons was confirmed to derive mainly from heat inflow through the sea surface from the air. Based on estimations of the average ocean heat transport rate in July for the four-year period of 2018-2021, Cheonsu Bay and Gamak Bay accounted for 13.5% and 62.3% outflow of the net heat flux, respectively. However, the ocean heat transport rate in Guryongpo Hajeong differed significantly from -174.5% to 132.5% of the net heat flux by year depending on the occurrence of cold water mass.