• Title/Summary/Keyword: Water Use Charge

Search Result 75, Processing Time 0.03 seconds

The Analysis of Stakeholders' Conflict Surrounding Water use Charges: Targeting the Han River region (한강수계 물이용부담금을 둘러싼 이해당사자 간 갈등분석)

  • Lee, Youngkyeong;Choi, Ye Seul;Kim, Chanyong;Lim, up
    • Journal of the Korean Regional Science Association
    • /
    • v.37 no.1
    • /
    • pp.45-61
    • /
    • 2021
  • This research purposes to design a methodological framework to suggest the optimal method to resolve the conflicts of stakeholders surrounding the water use charge of the Han River region, and to use the analysis results to provide the direction of policy. For this, it was preceded that the process of understanding the mechanisms of the multifaceted conflict between decision makers taking different positions over water use charge of the Han River region, and an optimal method to resolve the conflict of water use charge of the Han River region was derived by using a graph model for conflict resolution(GMCR). According to the analysis results, the optimal state to find a solution to the water use charge of the Han River is that the Seoul-Incheon-Gyeonggi region pays the charge according to the original rate while Seoul-Incheon requesting discount the water use rate. In addition, the Han River management committee should establish policies desired by Seoul-Incheon-Gyeonggi region including rationalization of the decision-making structure to determine the rate of water use charge, making the basis to support the Han River management fund system for the Seoul-Incheon region, and transparent management of the Han River management fund system considering the characteristics of beneficiary regions and residents. This study is expected to provide objective decision-making information in establishing environmental policy directions related to conflict resolution in the water use charge of the Han River region and to offer a methodological basis for similar follow-up studies related to conflicts derived from sharing nature environment.

The Effect of Industrial Waste Water Effluent Charge Reform (수질배출부과금제도 개선 방안 연구)

  • Min, DongKi
    • Environmental and Resource Economics Review
    • /
    • v.18 no.4
    • /
    • pp.767-785
    • /
    • 2009
  • This paper studies the effect of industrial waste water effluent charge reform. The goal of the present effluent charge system is to use environmental resources in an efficient way by charging the cost for removing emitted water pollutants. However, the present system is a type of regulation instead of providing economic incentives to the industry. That is, if a firm emits pollutants greater than the limit, it has to pay an amount greater than the cost of cleaning them taking into account the amount of waste water discharged, region, the number of violation and the level of density of pollutants. However, the excessive fees have resulted in the lowest ratio of revenue-to-effluent charge among all environmental charges. The paper estimates the effect of the change in effluent fee and revenue when the present effluent charge system is converted to one that offers economic incentives. The results show that the amount of waste water effluent charge is about four times larger than the estimated environmental cleaning cost. In addition, the results show that by modifying the effluent charge system, the ratio of revenue to effluent charge can be raised.

  • PDF

Evaluation of Streaming Current Detector (SCD) and Charge Analyzing System (CAS) for automation of coagulant dosage determination (낙동강 하류 원수의 응집제 주입 자동화를 위한 Streaming Current Detector (SCD)와 Charge Analyzing System (CAS)의 평가)

  • Kim, Sang-Goo;Son, Hee-Jong;Lee, Jeong-Kyu;Yeom, Hoon-Sik;Yoo, Pyung-Jong
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.39 no.4
    • /
    • pp.201-207
    • /
    • 2017
  • This study was conducted to investigate the characteristics of the stream current detector (SCD) and charge analyzing system (CAS), which are well known as the automatic coagulant dosage determination instruments. When the SCD system was used, the current charge value set at pH 9.3 could not be used as the coagulant dosage when the pH of the raw water decreased to 5.7, and the current charge value corresponding to pH 5.7 was required to be reset. In case of CAS system, polydadmac is stable as a cationic titrant when the pH of the raw water ranged 9.3 to 6.0. And it was effective to use polydadmac as a cationic titrant for high turbidity water. The current charge of polydadmac was almost constant between pH 5 and 11, however, the difference in charge of alum is six times in this pH range. Therefore, when the pH of the raw water was changed, it seems that the coagulant used in the actual water treatment plant was as a good cationic titrant.

The Determination of TRC using an Electrochemical Method (II: Pt electrode) (전기화학적 방법의 TRC(Total residual chlorine) 측정 연구(II: Pt전극 이용))

  • Lee, JunCheol;Pak, DaeWon
    • Journal of Korean Society on Water Environment
    • /
    • v.30 no.3
    • /
    • pp.304-310
    • /
    • 2014
  • The conventional methods for total residual chlorine such as iodometry and DPD colorimetric can cause secondary pollution due to additional agents, also have a wide error range. As for alternative, electrochemical method can measure TRC(Total residual chlorine), and is not required as additional agents, also very suitable for using the fields of ballast water because test time is relatively fast. Therefore, this study was investigated for changing charge by agitation, salt concentration, and temperature change. Charge showed differences based on changes of reduction peak with or without agitation. In contrast, TRC and charge were well correlated in constant agitation speed. As TRC and charge were analyzed with high correlations in constant salinity and temperature of ocean, thereby conductivity was firstly measured, and charge had high correlation for TRC in spite of changing salinity and temperature Pt electrode revealed high reliability ($r^2=0.960$) because it was rarely effected by TRC, On the other hand, Au electrode appeared inadequate ($r^2=0.767$) to use sensor in less than 1.0 ppm of TRC. For high accuracy and detection of TRC, Pt and Au electrodes for test time were, respectively, 14 and 22 seconds. As a result, Pt electrode was more valuable than Au electrode in terms of response time.

Design and Implementation of Fully Automated Solar Powered Irrigation System

  • Mohammad Fawzi Al Ajlouni;Essam Ali Al-Nuaimy;Salman Abdul-Rassak Sultan;Ali Hammod AbdulHussein Twaij;Al Smadi Takialddin
    • International Journal of Computer Science & Network Security
    • /
    • v.24 no.4
    • /
    • pp.197-205
    • /
    • 2024
  • This paper presents a fully automated stand-alone irrigation system with GSM (Global System for Mobile Communication) module. Solar energy is utilized to power the system and it is aimed to conserve water by reducing water losses. The system is based on a DC water pump that draws energy from solar panels along with automated water flow control using a moisture sensor. It is also fitted with alert and protection system that consists of an ultrasonic sensor and GSM messages sender that transmits signals showing the levels of the water in the reservoir and the battery charge. The control system is designed to stop the water pump from pumping water either when the battery level drops to equal or less than 10% of its full charge, or when the water level becomes less than 10 cm high in the reservoir. The experimental results revealed that the system is appropriate to use in remote areas with water scarcity and away from the national grid.

The Effects of Changing of Hydraulic Retention Time and Charging Media on the Removal of Nitrogen and Phosphorus in the Up-flow Anaerobic/Anoxic Reactor and Water-mill for Sewage Treatment (상향류식 혐기성조, 무산소조 및 수차호기조를 이용한 하수처리시 수리학적 체류시간의 변화와 메디아 충진이 질소 및 인 제거에 미치는 영향)

  • Shin, Myoung-Chul;Lee, Young-Shin
    • Journal of Environmental Health Sciences
    • /
    • v.35 no.1
    • /
    • pp.64-70
    • /
    • 2009
  • The aims of this study is to examine the effects of the changes in HRT(Hydraulic Retention Time) and media charge in a water-mill, among other operation factors, on the nitrogen and phosphorus removal in order to use up-flow anaerobic reactors, anoxic reactors and water-mill aerobic reactors for sewage treatment. The extension of HRT improved the nitrogen removal efficiency, however the removal pattern was constant regardless of HRT. The removal of phosphorus was constant (80%-90%) regardless of the change in HRT. The removal rate with change in influx load varied such that at the OLR (Organic Load Rate) of 1-3 kg/d, the T-N removal efficiency was 80.7%-88.9% and the T-P removal efficiency was 82.9%-89.3% while at the NLR (Nitrogen Loading Rate) of 0.108-0.156 kg/d the removal efficiencies were 80.7-88.9% (T-N) and 82.9-89.3% (T-P). The analyses of the nitrogen and phosphorous removal characteristics with the C/N and C/P ratio showed that the mean T-N removal rate was 88% at the C/N ratio of 1.2-2.6, and that the mean T-P removal rate was 86% at the C/P ratio of 7.2-14.1. Also, the analysis of nitrogen and phosphorous removal characteristics were analyzed in relation to media charge. The comparison between with and without media charge in the water-mill showed that while the nitrogen removal efficiencies were 86-94% and 85-89% respectively, the difference of phosphorous removal efficiencies were between the two conditions was not significant, thus it suggested that the media charge has less effect on the removal efficiency of phosphorous compared to that of nitrogen.

The Reaction Efficiency and Surface Characteristics for Metallic Ions in Air Flotation Process (부상공정에서 금속이온의 기포 표면 전위 특성 및 반응효율)

  • Han, Moo-Young;Dockko, Seok;Kim, Young-Hwan
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.18 no.2
    • /
    • pp.222-227
    • /
    • 2004
  • Flotation processes involve the use of very small bubbles (micro-bubbles) to separate particles from water. The process has become a good alternative to sedimentation, especially where the particles are small or of low density. Although the flotation process commences with a collision between particles and bubbles, most research has been focused only on the characteristics of the particles. In this paper, recent theoretical and experimental research on the characteristics of bubbles is summarized. The effect on the collision efficiency of the size and charge of bubbles is calculated through trajectory analysis. The size and charge of bubbles are measured under different conditions and the ramifications of the results are discussed. The results may lead to a better understanding and optimization of the existing process. In particular, we discuss an idea that a new advanced flotation process might be possible by the modification of the characteristics of the bubble alone or of both bubble and particle.

Survey of Farmers' Perception and Behavior for Agricultural Water Saving - Applying to Irrigation Facility Monitors in Pohang and Yeongdeok Areas - (농업용수 물절약에 대한 농업인 의식 및 행동 조사 - 포항·영덕지역 수리시설감시원을 대상으로 -)

  • Lee, Seul-Gi;Choi, Kyung-Sook
    • Journal of Korean Society of Rural Planning
    • /
    • v.26 no.3
    • /
    • pp.39-47
    • /
    • 2020
  • While agricultural water has been declared free in Korea to ensure access to these limited resource since the year 2000, farmers have however developed lackadaisical behavior towards water saving leading to its scarcity. To overcome this problem, a variety of experience-oriented education model was developed for farmers to promote the adoption of water conservation, and preventive measure against the drought impacts. In this study, farmers' awareness and their attitudinal behavior of agricultural water savings were investigated. The monitoring of water supply structure and the repair facilities in Pohang and Yeongdeok areas were conducted. The field visits and behavioral surveys showed a high degree of over-use and illegal water withdrawals by the farmers due to poor water-saving and management practices. We found that most of the KRC employees strongly admitted the necessity of water-saving education. On the other hand, the farmers showed good interest in the implementation of water-saving awareness through education. Besides this, most farmers agreed to adopt water-saving practices in the fields. Farmers also acknowledged the recklessness of water use was due to the aging of waterways, poor water management, and illegal water consumption. The majority of the farmers responded against imposing the water-use tariffs. However, there was a low response to paying the water-use charge. Aging agricultural facilities and the lack of institutional penalties or incentives were the major obstacles in achieving efficient water-saving. Considering the current drought frequency, urgent water-saving education of farmers was deemed necessary to prepare the farming community against the water shortages. Based on the results of this study, we have to identify the irrigation practices of farmers and provide water-saving education to enforce more efficient use and management of agricultural water.

Flocculation and Retention Phenomena of Microparticle Retention Systems Based on Cationic Guar Gums and Colloidal Silicas (양이온성 구아 검과 콜로이달 실리카를 이용한 보류시스템의 응집 및 보류 현상)

  • 함충현;이학래
    • Journal of Korea Technical Association of The Pulp and Paper Industry
    • /
    • v.33 no.4
    • /
    • pp.1-6
    • /
    • 2001
  • Today's paper industry tries to use greater amount of high yield pulp and recycled fiber and to close mill water system, which results in higher fines content and buildup of organic and inorganic contaminants in white water system. Researches are being focused to develop chemical additives that provide good retention and drainage in a closed papermaking system. A microparticle retention system consisted of cationic guar gum and anionic colloidal silica so has been developed to meet the requirements for improving machine speed and product quality. The objective of this investigation was to determine the effects of the degree of cationic guar gums, charge density and structure of anionic colloidal silica sols, and the degree of system closure on the performances of this microparticle retention system. Cationic guar gums and anionic colloidal silica sols with higher charge densities showed better retention performance. Particularly, wider maximum in retention was obtained when structure colloidal silica was used suggesting as mechanism of microparticle bridging is functioning in this system.

  • PDF

A Case Study of Underwater Blasting (수중발파 사례 연구)

  • 정민수;박종호;송영석
    • Explosives and Blasting
    • /
    • v.22 no.3
    • /
    • pp.57-64
    • /
    • 2004
  • There are two major types of underwater blasting at Korea, bridges and harbor construction work. Pier blasting for lay the foundation bridges construction is used dry excavation working (drilling and charging) after pump out water and then fire pump in water that is same as bench blasting. In contrast, underwater blasting for harbor construction and increase of harbor load depth is used to barge with digging equipment that is in oder to drilling on the surface and blasting work(charge, hook-up) under water. Thus, there are need to special concern such as charge method and hook-up method different from tunnel blasting work and bench blasting work. If do not use special concern breaks out dead pressure and mis fire because of there are so many difficult condition such as water pressure, obstruct field of vision. In this study underwater blasting at Busan Harbor Construction have consider with special concern that is plastic pipe charge method used to MegaMITE I and specialized buoy hook- up method make far initial system detonate on the surface used to TLD. The results is designed blast pattern charge per delay effect an inspection of verify between predict velocity and measure velocity. minimized break out mis fire consideration charge method, hook up method. According to result best underwater blasting design is 105mm drilling dia, MeGAMITE II, HiNLL Plus(non electric detonator).