• 제목/요약/키워드: Water Tightness

검색결과 66건 처리시간 0.032초

Z형 강널말뚝의 오염물질 차단효과 (The permeability charateristic of Z-type sheet pile joints under water sealing conditions)

  • 홍승서;이용수;정하익
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2009년도 세계 도시지반공학 심포지엄
    • /
    • pp.1283-1288
    • /
    • 2009
  • In general steel sheet piles are used in the containment system, which are vertical barrier systems for waste disposal and landfill purposes, and roads in excavation for temporary structure. This paper presents case study of the use of an interlocking sheet pile for water and containment. Cut-off Z-type sheet pile joints are investigated to determine their permeability from the field test. Four different joint sealing materials are used in field test. The results showed joint permeability is significant time-dependent and joint-dependent. These are explored and conclusions on permeability characteristics of different sealants are noted. A case study gives a design example as well as suggestion on permeability and water tightness can be implemented in using the sheet pile barrier in civil and environment works. From the test results, the effective sealing programs of sheet pile interlocks are suggested.

  • PDF

Research of Novel Water Cooling Jacket for Explosion-proof Motor

  • Wang, Yu;He, Huiming;Bai, Baodong
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • 제3권1호
    • /
    • pp.67-71
    • /
    • 2014
  • The well tightness of the coal mining water-cooling explosion-proof motor results in difficult heat dissipation, high hydraulic pressure is needed to increase the cooling effect. However, high hydraulic pressure may lead motor shell to deform, which makes it difficult to change the motor and maintain the motor unit. The method of adding keyhole caulk weld spots on the outer cooling water jacket was proposed to solve the problem. Based on the elasticity mechanics equations and the principle of finite element method the stresses and the deformations of the traditional and novel outer cooling water jacket were calculated separately. A hydraulic pressure experiment of the both cooling water jackets was constructed. Obviously, the stress and the deformation of the novel cooling water jacket are lower. The experimental result is consistent with the simulation results. It is effective to reduce the stress and the deformation of the cooling water jacket by adding the keyhole caulk weld spots.

Corrosion and Sliding Properties of the Nickel-Based Alloys for the Valve Seats Application

  • Honda, Tadashi
    • Corrosion Science and Technology
    • /
    • 제7권2호
    • /
    • pp.92-98
    • /
    • 2008
  • This paper describes the experiments of the corrosion and the sliding tests of the nickel-based alloys for the gate valve seating materials used at high pressure and temperature. The general corrosion rates and IGC susceptibility are tested in pressurized water at 533 K and 575 K and in Strauss test solution. The sliding tests have been done in pressurized water at 293 k, 473 K and 573 k. The alloys containing above 10% chromium may have the anti-corrosion properties that could be applied to the valve seats for the power plants. The good sliding performance and the good pressure tightness are obtained when the disc specimens that have hardness 500 to 600 Hv combined with the seat specimens that have hardness 250 to 410 Hv containing about 40 percent of iron. The large size gate valves sliding tests have certified the test results. The anti-wear properties of the seat alloy and the anti-IGC susceptibility of the disc alloy could be improved by the addition of silicon and niobium, respectively.

폴리에틸렌 하수관 연결용 전기발포융착 이음관에 관한 연구 (A Study of Electro-foaming Fusion Wrap for Polyethylene Sewer Pipe)

  • 계형산;주경훈
    • 상하수도학회지
    • /
    • 제26권3호
    • /
    • pp.343-354
    • /
    • 2012
  • A electro-foaming fusion wrap fitting for polyethylene sewer pipe was built and foaming mechanism has been studied. A foaming sheet, supporting sheet and clamping band is assembled into a all-in-one structured electro-foaming fusion wrap fitting. To specify foaming and fusion of electro-foaming fusion wrap for PE sewer pipe, series of fusion tests were performed in various conditions. A parallel plate compression test up to 50 % of inner diameter deflection has been performed to check integrity of fusion quality and it was found that there were no visible signs of crack in wrapped area of fitting. Also air tightness test based on KS M 3511-2 has been performed to evaluate perfectness of wrap fusion quality and we found there were no pressure drop up to 10 times higher value than KS standard regulation.

한국철도공사 작업복에 관한 연구 (제2보) - 동복 하의를 중심으로 - (A Study on Work Clothes for Korea Railroad (Part II) - Focused on Winter Pants -)

  • 김지원;류현숙
    • 한국의류학회지
    • /
    • 제33권3호
    • /
    • pp.410-419
    • /
    • 2009
  • The purpose of this study was to develop the functionally improved winter work clothing for the Korean railroad workers. Based on the questionnaires, sample clothing for the Korean railroad workers was produced. The design, materials, and patterns were modified to increase mobility and comfort for workers. Water-repellent treatment was added to the material in order to decrease the dirt and stains while working. Also, reflective strips were added to side seams and hems of the trousers in order to increase the visibility and safety of the workers. In terms of the design and pattern, a circumference of 4.5cm was added to the crotch area in order to minimize tightness on the hip and crotch areas, but no additional circumference was added to the hip area. And a 1cm width dart was inserted between the side seams and yoke in order to add activity. Also three 1.4cm width tucks were used at 2.5cm space on the knees to alleviate tightness at the knees. The prototype was evaluated objectively and subjectively to compare with the existing working uniform. The assessment group consisted of 5 subject groups and 11 expert groups to evaluate external appearance and adaptability of the movements. Subject and panels were asked to evaluate the prototype that followed an ergonomic design and pattern. According to the results, the prototype was evaluated better than the existing working uniform in appearance and adaptability. A field test was conducted to compare the prototype and the existing working uniform. The field tests were performed by 6 workers in the Korean railroad. According to the results, the prototype advanced in terms of adaptability and comfort.

지하 원유 저장공동에서의 누수량 산정에 대한 연구 (Estimation of Water Leak Rate in the Underground Oil Storage Cavern)

  • 심현진;박태준;정우철;김호영;최영태
    • 터널과지하공간
    • /
    • 제20권4호
    • /
    • pp.233-240
    • /
    • 2010
  • 지하 원유 저장공동에서 두 공동간의 혼유 방지를 위해 설치되는 더블 플러그는 구조물 시공 후 더블 플러그 내부를 물로 채운 후에 충수의 누수 정도를 파악함으로써 플러그 기밀성을 평가한다. 만약 예상 누수량이 과소하게 산정되면 시공비용이 증대되고, 과다하게 산정될 경우에는 운영비용이 증가될 수 있으므로 최적의 예상 누수량을 산정할 필요가 있다. 본 연구에서는 더블 플러그(double plug) 주변의 투수특성을 보다 정확하게 반영할 수 있도록 수리 안정성 해석을 수행하였으며, 수리 안정성 해석 및 기존 사례 분석 과정을 통해 플러그 주변의 누수 가능성이 있는 모든 경로에 대한 예상 누수량을 산정하였다. 또한 누수 경로에 대한 누수량을 실측 하여 예상 누수량 산정 결과의 신뢰성을 확인하였다.

철도차량 기후환경시험을 위한 국제 규격(UIC, EN, IEC) 및 국내 규격(시험방법) 분석 및 고찰 (Analysis and Investigation of International(UIC, EN, IEC) and Domestic Standards(Test Methods) for Climatic Wind Tunnel Test of Rolling Stock)

  • 장용준;정종덕;이재천
    • 한국산학기술학회논문지
    • /
    • 제21권12호
    • /
    • pp.782-789
    • /
    • 2020
  • 국내에서 제작되는 철도차량의 해외 시장 개척을 위하여 다양한 기후환경에서도 최고의 성능을 유지하기 위한 철도차량의 기술개발이 시급하다. 본 연구에서는 혹독한 기후환경시험 모사 시스템 구축에 필수적으로 적용되어야 할 국제·국내 규격을 조사 및 비교 분석하였으며, 국내 규격의 향상 방안을 고찰하였다. 기후환경시험 풍동내에서 풍속 및 온도 규정은 UIC, EN 및 IEC 규격에 규정되어 있으며, EN 50125-1에서 가장 큰 풍속인 180km/h까지 시험하도록 되어있다. 극저온 시험은 UIC 및 EN 규격에서 가장 낮은 온도 -45℃를 제시하고 있으며, IEC 62498-1에서 55℃까지의 고온시험을 규정하고 있다. 태양광 복사 시험은 UIC, EN, IEC 규격에서 최대 1200W/m2 복사 강도까지 규정되어 있다. 강우시험은 IEC, EN 및 KS R 9145 규격에서 규정하고 있으며 살수량, 살수 압력 및 살수방법 등에서 차이점이 있다. 강설시험의 경우는 국내외적으로 상세히 규정되어 있지 않다. 여압 시험은 KRTS-VE-Part31 국내 기준에서 규정되어 있다. 고속 철도차량 기밀시험은 UIC 660 및 779-11에서 객실내 압력 변화율 규정이 있으며 차량 기밀도가 규정되어 있다. 국내 규격에서는 풍속에 대한 규정은 매우 미비하며, 태양광 복사 시험 및 강설 시험 규격은 존재하지 않는다. 철저한 기후환경 시험을 위하여 국내 철도 완성차 관련 기술기준 및 시험 규격을 국제수준으로 향상시킬 필요가 있는 것으로 판단된다.

초지연제를 이용한 매스콘크리트의 수화열 조정에 관한 연구 (A Study on the Control of Hydration Heat of Mass Control Using Super Retarding Agent)

  • 유동수;심보길;윤치환;한민철;한천구
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2001년도 봄 학술발표회 논문집
    • /
    • pp.469-474
    • /
    • 2001
  • Mass concrete is placed considering placing lifts in order to reduce thermal cracks by hydration heat. But they results in cold joint between placing lifts, which bring about the loss of strength, water tightness and undesirable appearance. Therefore, in this paper, mechanical and hydration heat of mass concrete using super retarding agent developed through previous study are investigated in order to reduce the hydration heat and place it without place lift. According to test results, placing lifts combined with normal concrete and concrete containing super retarding agent have positive effects on reducing hydration heat. Especially, the crack index by thermal stress of the concrete containing super retarding agent less than a quarter, compared to that of plain concrete without placing lifts, and less than a half, compared to that of plain concrete with placing lifts.

  • PDF

초지연제를 이용한 매스콘크리트의 수화열 조정에 관한 연구 (A Study on the Control of Hydration Heat of Mass Concrete Using Super Retarding Agent)

  • 유동수;심보길;윤치환;한민철;한천구
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2001년도 봄 학술발표회 논문집
    • /
    • pp.515-520
    • /
    • 2001
  • Mass concrete is placed considering placing lifts in order to reduce thermal cracks by hydration heat. But they results in cold joint between placing lifts, which bring about the loss of strength, water tightness and undesirable appearance. Therefore, in this paper, mechanical and hydration heat of mass concrete using super retarding agent developed through previous study are investigated in order to reduce the hydration heat and place it without place lift. According to test results, placing lifts combined with normal concrete and concrete containing super retarding agent have positive effects on reducing hydration heat. Especially, the crack index by thermal stress of the concrete containing super retarding agent less than a quarter, compared to that of plain concrete without placing lifts, and less than a half, compared to that of plain concrete with placing lifts.

  • PDF

응결시간차를 활용한 매스콘크리트의 수화열 조정에 관한 기초적 연구 (A Fundamental Study on the Control of Hydration Heat of Mass Concrete Using Setting Time Difference)

  • 배정렬;윤치환;김기철;한민철;오선교;한천구
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2002년도 학술논문발표회
    • /
    • pp.41-45
    • /
    • 2002
  • Placing lift is applied to place mass concrete in order to reduce thermal cracks by hydration heat. But they results in cold joint between placing lifts, which bring about the loss of strength, water tightness and undesirable appearance. Therefore, in this paper, mechanical and hydration heat of mass concrete using super retarding agent developed through previous study are investigated in order to reduce the hydration heat and place it without place lift. According to test results, placing lifts combined with normal concrete and concrete containing super retarding agent have positive effects on reducing hydration heat. Especially, the crack index by thermal stress of the concrete containing super retarding agent less than a quarter, compared to that of plain concrete without placing lifts, and less than a half, compared to that of plain concrete with placing lifts.

  • PDF