• Title/Summary/Keyword: Water Tank

Search Result 2,116, Processing Time 0.032 seconds

Comparison study of dermal cell toxicity and zebrafish brain toxicity by humidifier sterilizer chemicals (PHMG, PGH, CMIT/MIT) (가습기 살균제 성분(PHMG, PGH, CMIT/MIT)의 사람 피부세포 독성 및 제브라피쉬 뇌신경 독성 비교 연구)

  • Cho, Kyung-Hyun;Kim, Jae-Ryong
    • Korean Journal of Environmental Biology
    • /
    • v.38 no.2
    • /
    • pp.271-277
    • /
    • 2020
  • Toxicities to many organs caused by humidifier disinfectants have been reported. Recently, humidifier disinfectants have been reported to cause cardiovascular, embryonic, and hepatic toxicities. This study was designed to investigate the toxic mechanism of humidifier disinfectants and compare toxicity in a cellular model and a zebrafish animal model. Because brain toxicity and skin toxicity have been less studied than other organs, we evaluated toxicity in a human dermal cell line and zebrafish under various concentrations of humidifier disinfectants that included polyhexamethyleneguanidine phosphate (PHMG), oligo-[2-(2-ethoxy)-ethoxyethyl-guanidinium-chloride] (PGH) and methylchloroisothiazolinone/methylisothiazolinone (CMIT/MIT). A human dermal fibroblast cell line was treated with disinfectants (0, 2, 4, 6, 8, and 16 mg L-1) to compare their cytotoxicity. The fewest PHMG-treated cells survived (up to 33%), while 49% and 40% of the PGH- and CMIT/MIT-treated cells, respectively, survived. The quantification of oxidized species in the media revealed that the PHMG-treated cells had the highest MDA content of around 28 nM, while the PGH- and CMIT/MIT-treated cells had 13 and 21 nM MDA, respectively. As for brain toxicity, treatment of the zebrafish tank water with CMIT/MIT (final 40 mg L-1) for 30 min resulted in a 17-fold higher production of reactive oxygen species (ROS) than in the control. Treatment with PGH or PHMG (final 40 mg L-1) resulted in 15- and 11-fold higher production, respectively. The humidifier disinfectants (PHMG, PGH, and CMIT/MIT) showed severe dermal cell toxicity and brain toxicity. These toxicities may be relevant factors in understanding why some children have language disorders, motor delays, and developmental delays from exposure to humidifier disinfectants.

The Fabricating and Utilizing of the Transmission Scan Tool for I-131 Whole Body Scan (I-131 전신 스캔을 위한 Transmission Scan Tool 제작과 활용)

  • Shin, Chae-Ho;Pyo, Sung-Jai;Kim, Bong-Su;Cho, Yong-Gyi;Jo, Jin-Woo;Kim, Chang-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.13 no.1
    • /
    • pp.40-46
    • /
    • 2009
  • Purpose: A whole body scan using a radioactive iodine (I-131) for the patients with differentiated thyroid cancer is generally an useful method to detect the remnant thyroid tissue, recurred lesion or metastasis lesion after a surgery. The high dose treatment using the radioactive iodine recently tends to increase, and a hospitalization wait for the treatment has been delayed for several months. In this hospital, the treatable patients per week were increased in number through expanding a water-purifier tank and the examination time also increased as the I-131 whole body scan patients increased. Improvement for this problem, this research reduce the existing examination time and classifying the lesion's exact position intended to by fabricating and utilizing the transmission scan tool and an excellent resolution for whole body imaging. Materials and Methods: After conducting the whole body scan for patients who visited the department from February to July 2008 and received the I-131 whole body scan using the ORBITER Gamma Camera. A rail was installed in the examination table for the transmission scan for show a contour of surface area and then the transmission image was obtained and fused to the whole body scan through fabricating the tool to put a flood phantom of diluted 2 mCi $^{99m}Tc$-pertechnetate. Results: Fused image of I-131 whole body scan and the transmission scan had the excellent resolution to discriminate an oral cavity or salivary gland region, neck region's lesion, and metastasis region's position through a simple marking, and could reduce the examination time of 8~28 minutes because without the additional local image. Conclusions: In I-131 whole body scan, the transmission scan can accurately show a contour of surface area through the attenuation of radioactivity, and is useful to indicate the remnant thyroid tissue or metastasis lesion's position by improving the resolution through the fusion image with alreadyexecuted I-131 whole body scan. Also, because the additional local image is not necessary, it can reduce the time required for the examination. It will extensively apply to other clinical examinations to be helpful for identifying an anatomical position because it shows the contour of surface area.

  • PDF

A Study on the Fouling of Ultrafiltration Membranes Used in the Treatment of an Acidic Solution in a Circular Cross-flow Filtration Bench (순환식 막 모듈 여과장치를 이용한 산성용액의 수처리 공정 시 발생하는 한외여과막 오염에 관한 연구)

  • Kim, Nam-Joon;Choi, Chang-Min;Choi, Yong-Hun;Lee, Jun-Ho;Kim, Hwan-Jin;Park, Byung-Jae;Joo, Young-Kil;Kang, Jin-Seok;Paik, Youn-Kee
    • Membrane Journal
    • /
    • v.19 no.3
    • /
    • pp.252-260
    • /
    • 2009
  • The effects of the treatment of an acidic solution at pH 2 on polyacrylonitrile ultrafiltration (UF) membranes were investigated using a circular cross-flow filtration bench with a membrane module. A substantial reduction in the membrane permeability was observed after 80 hours' treatment of the acidic solution. In addition, the analyses of the sample solutions by ultraviolet/visible absorption spectroscopy and gas chromatography/mass spectrometry (GC/MS), which were taken from the feed tank as a function of the treatment time, showed that a new organic compound was produced in the course of the treatment. From a thorough search of the mass spectral library we presumed the new compound to be 1,6-dioxacyclododecane-7,12-dione (DCD), one of the well-known additives for polyurethane. Based on further experimental results, including the scanning electron microscope (SEM) images and the solid-state NMR spectra of the membranes used for the treatment of the acidic solution, we suggested that the decrease of the permeate flux resulted not from the deformation of the membranes, but from the fouling by DCD eluted from the polyurethane tubes in the filtration bench during the treatment. Those results imply that the reactivity to an acidic solution of the parts comprising the filtration bench is as important as that of the membranes themselves for effective treatments of acidic solutions, for efficient chemical cleaning by strong acids, and also in determining the pH limit of the solutions that can be treated by the membranes.

Quality Properties of Appenzeller Cheese Containing Sasam(Codonopsis lanceolate) Wine (사삼주를 이용한 아펜젤러 치즈의 품질 특성)

  • Choi, Hee-Young;Park, En-Ha;Yang, Chul-Ju;Choi, Kap-Sung;Kim, Hoi-Gyung;Bae, In-Hyu
    • The Korean Journal of Food And Nutrition
    • /
    • v.23 no.3
    • /
    • pp.352-360
    • /
    • 2010
  • This study was performed to develop a Korean natural cheese with traditional medical wine, making it different from foreign natural cheese. The effects of cheese with Sasam(Codonopsis lanceolate) wine(CLW) on the quality properties during the ripening period of natural cheese were investigated. The properties investigated were growth of lactic acid bacteria, characteristics of ripening, and sensory characteristics. Four vats of cheese were made on the same day from the same tank of fresh milk. Cheese samples were prepared with CLW at 2.0%, 4.0% and 6.0% of raw milk. Changes in gross composition, viable cell counts, pH, water soluble nitrogen(WSN), non casein nitrogen(NCN), non protein nitrogen(NPN), and proteolysis during maturation were measured. Polyacrylamide gel electrophoresis(PAGE) patterns were determined with control cheese. Viable cell counts of control and CLW cheese were not significantly different. The pH of CLW cheese increased gradually during maturation, and saponin levels and levels of NPN, NCN, and WSN were higher in CLW cheeses than control cheese. For most compositional data, the 4.0% CLW cheese was most similar to the control cheese. The PAGE pattern of cheese caseins indicated that the CLW cheeses degraded more rapidly than the control cheese. Control and 2.0% CLW cheese had good sensory scores, while scores for 4.0% and 6.0% CLW cheese were lower. However, sensory data depreciated with added levels of CLW, especially at a level of 4.0% or more. Further studies on levels of CLW and processing methods are required to improve sensory quality.

Alpha-glucosidase Inhibition Activity of Methanol Extracts Obtained from Nine Pteridophyte Species Native to Korea (자생 양치식물 9종의 성엽 및 근경 추출물의 α-glucosidase 억제 활성)

  • Kim, Na Rae;Chi, Lai Won;Lee, Cheol Hee
    • Korean Journal of Plant Resources
    • /
    • v.26 no.4
    • /
    • pp.411-416
    • /
    • 2013
  • This study was conducted not only to analyze ${\alpha}$-glucosidase inhibition activity with fronds and rhizomes of nine Pteridophyte species, but also to select the plant materials suitable for natural ${\alpha}$-glucosidase inhibitor. Harvested rhizomes and fronds were washed, freeze-dried and grinded. After conducting ultrasonification extraction for 30 minutes in ultrasonic water tank with 100% methanol solvent, and vacuum filtration, ${\alpha}$-glucosidase inhibition activity was measured. Acarbose was used as the positive control. After mixing $100{\mu}L$ of 0.7 unit ${\alpha}$-glucosidase enzyme solution into $50{\mu}L$ of extract and reacting them at $37^{\circ}C$ for 10 minutes, $50{\mu}L$ of 1.5 mM ${\rho}$-NPG solution was taken and reacted at $37^{\circ}C$ for 20 minutes. The reaction was stopped with 1 mL of 1 M $Na_2CO_3$ and absorbance was measured in 405 nm. With the regression analysis, the content of solubility solids (the value of $IC_{50}$) which can inhibit 50% of 0.7 unit ${\alpha}$-glucosidase solution's activity was investigated. The frond ($IC_{50}=14.00{\sim}913.33{\mu}g{\cdot}mL^{-1}$) and rhizome extracts ($IC_{50}=12.93{\sim}205.84{\mu}g{\cdot}mL^{-1}$) of nine Pteridophyte species showed higher ${\alpha}$-glucosidase inhibition activity in comparison with acarbose ($IC_{50}=1413.70{\mu}g{\cdot}mL^{-1}$). The extracts of fronds and rhizomes showed higher value than acarbose by 1.55~100.98 and 6.87~109.33 times each. Especially, ${\alpha}$-glucosidase inhibition activities of Pyrrosia lingua in fronds and Osmunda cinnamomea var. fokiensis in rhizomes were the highest. The necessary biomass of fronds and rhizomes for inhibiting 50% of ${\alpha}$-glucosidase activity showed the lowest value, 0.35, 0.27 mg each, in O. cinnamomea var. fokiensis. $IC_{50}$ value of P. lingua was the highest among fronds of nine Pteridophyte species, but content of soluble solids was 2.4 times less than O. cinnamomea var. fokiensis. So frond of O. cinnamomea var. fokiensis is more economic in comparison with P. lingua. As the result of this study, O. cinnamomea var. fokiensis showed high ${\alpha}$-glucosidase inhibition activity even with small biomass. Therefore it was considered to be high-valued economic material as natural ${\alpha}$-glucosidase inhibitor.

Recent Progress in Air Conditioning and Refrigeration Research - A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2004 and 2005 - (공기조화, 냉동 분야의 최근 연구 동향 -2004년 및 2005년 학회지 논문에 대한 종합적 고찰-)

  • Choi, Yong-Don;Kang, Yong-Tae;Kim, Nae-Hyun;Kim, Man-Hoe;Park, Kyoung-Kuhn;Park, Byung-Yoon;Park, Jin-Chul;Hong, Hi-Ki
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.19 no.1
    • /
    • pp.94-131
    • /
    • 2007
  • A review on the papers published in the Korean Journal of Air-Conditioning and Refrigerating Engineering in 2004 and 2005 has been done. Focus has been put on current status of research in the aspect of heating, cooling, air-conditioning, ventilation, sanitation and building environment. The conclusions are as follows. (1) Most of fundamental studies on fluid flow were related with heat transportation of facilities. Drop formation and rivulet flow on solid surfaces were interesting topics related with condensation augmentation. Research on micro environment considering flow, heat, humidity was also interesting for comfortable living environment. It can be extended considering biological aspects. Development of fans and blowers of high performance and low noise were continuing topics. Well developed CFD and flow visualization(PIV, PTV and LDV methods) technologies were widely applied for developing facilities and their systems. (2) The research trends of the previous two yews are surveyed as groups of natural convection, forced convection, electronic cooling, heat transfer enhancement, frosting and defrosting, thermal properties, etc. New research topics introduced include natural convection heat transfer enhancement using nanofluid, supercritical cooling performance or oil miscibility of $CO_2$, enthalpy heat exchanger for heat recovery, heat transfer enhancement in a plate heat exchanger using fluid resonance. (3) The literature for the last two years($2004{\sim}2005$) is reviewed in the areas of heat pump, ice and water storage, cycle analysis and reused energy including geothermal, solar and unused energy). The research on cycle analysis and experiments for $CO_2$ was extensively carried out to replace the Ozone depleting and global warming refrigerants such as HFC and HCFC refrigerants. From the year of 2005, the Gas Engine Heat Pump(GHP) has been paid attention from the viewpoint of the gas cooling application. The heat pipe was focused on the performance improvement by the parametric analysis and the heat recovery applications. The storage systems were studied on the performance enhancement of the storage tank and cost analysis for heating and cooling applications. In the area of unused energy, the hybrid systems were extensively introduced and the life cycle cost analysis(LCCA) for the unused energy systems was also intensively carried out. (4) Recent studies of various refrigeration and air-conditioning systems have focused on the system performance and efficiency enhancement. Heat transfer characteristics during evaporation and condensation are investigated for several tube shapes and of alternative refrigerants including carbon dioxide. Efficiency of various compressors and expansion devices are also dealt with for better modeling and, in particular, performance improvement. Thermoelectric module and cooling systems are analyzed theoretically and experimentally. (5) According to the review of recent studies on ventilation systems, an appropriate ventilation systems including machenical and natural are required to satisfied the level of IAQ. Also, an recent studies on air-conditioning and absorption refrigeration systems, it has mainly focused on distribution and dehumidification of indoor air to improve the performance were carried out. (6) Based on a review of recent studies on indoor environment and building service systems, it is noticed that research issues have mainly focused on optimal thermal comfort, improvement of indoor air Quality and many innovative systems such as air-barrier type perimeter-less system with UFAC, radiant floor heating and cooling system and etc. New approaches are highlighted for improving indoor environmental condition as well as minimizing energy consumption, various activities of building control and operation strategy and energy performance analysis for economic evaluation.

Influence of Glycerol Concentration, Freezing Rate and Thawing Rate on Survival of Canine Spermatozoa Frozen (개 정자의 동결보존에 있어서 Glycerol 농도, 동결 및 융해 속도가 정자의 생존율 및 운동성에 미치는 영향)

  • Lee, Je-Hyub;Park, Hyang;Park, Heum-Dae;Kim, Jae-Myung
    • Journal of Embryo Transfer
    • /
    • v.18 no.3
    • /
    • pp.195-201
    • /
    • 2003
  • This study was carried out to establish most suitable freezing condition, to evaluate the different condition of freezing and thawing rates on the viability and motility of frozen canine spermatozoa. The ejaculated semen was added to obtained 200∼400 ${\times}$ 10$^{6}$ /$m\ell$ with extender I and was cooled to 4$^{\circ}C$ over 30, 60 and 120 minutes. And then, semen was diluted with extender II containing 4, 6 and 8%(v/v) glycerol for 60 min, respectively and packaged in 0.5$m\ell$ straw, equilibrated far 30, 60 and 120 min at 4$^{\circ}C$ and cryopreserved in liquid nitrogen vapor at different distance(3, 5, 7 and 9 cm, respectively), plunged into nitrogen tank. Samples were thawed by placing straws into 27, 37, 47, 57$^{\circ}C$ water bath for 120, 20 and 12 sec, respectively. The results were as follows; 1. The survival and motility rate immediately post-thawing was significantly higher in samples frozen in 4% glycerol than 6 or 8% glycerol(P< 0.05). 2. According to equilibration time at 4$^{\circ}C$, the survival and motility rate immediately post-thawing was significantly higher in samples frozen after 60 min equilibration than 30 or 120 min equilibration(P<0.05). 3. Freezing in distance of 5 cm from liquid nitrogen yield better survival and motility rate than the others(3, 7 or 9 cm)(P<0.05). 4. The effect of thawing rate on sperm survival were higher when the thawing was done at 37$^{\circ}C$ for 120 sec(P<0.05).

The Design of Broadband Ultrasonic Transducers for Fish Species Identification - Dual Resonance Design of a Ultrasonic Transducer Using a Single Acoustic Matching Layer - (어종식별을 위한 광대역 초음파 변환기의 설계 II - 단일음향정합층을 이용한 이중공진형 변환기의 설계 -)

  • 이대재
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.34 no.1
    • /
    • pp.74-84
    • /
    • 1998
  • A doubly resonant ultrasonic transducer has been designed as an attempt to increase the bandwidth of underwater transducers. The dual resonance conditions were accomplished by attaching a single acoustic matching layer on the front face of a Tonpilz transducer consisted of an aluminum head, a piezoelectric ring, a brass tail and a prestress bolt. A modified Mason's model was used for the performance analysis and the design of transducers, and the constructed transducers were tested experimentally and numerically by changing the impedances and thicknesses of the head, tail and matching layers in the water tank. Two distinct resonance peaks in the transmitting voltage response(TVR) of a developed transducer were observed at 34.3 and 40.4 kHz, respectively, with the difference frequency of 6.1kHz and the center frequency of 37.2kHz. The values of TVR at these frequencies were 136.5 dB re $1\;\muPa/V$ at 34.3 kHz and 136.8 dB re $1\;\muPa/V$ at 40.4 kHz, respectively. Reasonable agreement between the experimental results and the numerical results was achieved. From this result, it is expected that the generation of the distinct resonances at any two desired frequencies can be achieved through the proper choice of the matching layer to provide the impedance transformation between the transducer and the medium.

  • PDF

The Design of Broadband Ultrasonic Transducers for Fish Species Identification - Bandwidth Enhancement of a Ultrasonic Transducer Using Double Acoustic Matching Layers- (어종식별을 위한 광대역 초음파 변환기의 설계 ( III ) - 이중음향정합층을 이용한 초음파 변환기의 대역폭 확장 -)

  • 이대재
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.34 no.1
    • /
    • pp.85-95
    • /
    • 1998
  • The broadband ultrasonic transducers have been designed to use in obtaining the broadband echo signals from fish schools in relation to the identification of fish species. The broadening of bandwidth was achieved by attaching double acoustic matching layers on the front face of a Tonpilz transducer consisted of an aluminum head, a piezoelectric ring, a brass tail and to evaluate the performance characteristics, such as the transmitting voltage response(TVR) of transducers. The constructed transducers were tested experimentally and numerically by changing the parameters such as impedances and thicknesses of the head, tail and matching layers, in the water tank. Also, the developed transducer was excited by a chirp signal and the received chirp waveforms were analyzed. According to the measured TVR results, the available 3 dB bandwidth of the transducer with double matching layers of an $Al_O_3/epoxy$ composite of 7 mm thick and a polyurethane window of 18 mm thick was 7.3 kHz with a center frequency of 38.8 kHz, and the maximum and the minimum values of the TVR in this frequency region were 135.7 dB and 132.7 dB re $1\;{\mu}Pa/V$ at 1 m, respectively. Also, the available 3 dB bandwidth of the transducer with double matching layers of an $Al_O_3/epoxy$ composite of 11 mm thick and a polyurethane window of 15 mm thick was 6.2 kHz with a center frequency of 38.6 kHz, and the maximum TVR value in the frequency region was 136.3 dB re $1\;{\mu}Pa/V$ at 1 m. Reasonable agreement between the experimental results and the numerical results for the TVR of the developed transducers was achieved. The frequency dependant characteristics of experimentally observed chirp signals closely matched to the measured TVR results. These results suggest that there is potential for increasing the bandwidth by varying other parameters in the transducer design and the material of the acoustic matching layers.

  • PDF

Effects of Gadolinium Contrast agent on Bone Mineral Density Measurement using Dual Energy X-ray Absorptiometry (가돌리늄조영제가 이중에너지 X-선 흡수법을 이용한 골밀도검사에 미치는 영향)

  • Lee, Keun-Ohk;Lee, Min-Su
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.1
    • /
    • pp.63-70
    • /
    • 2021
  • Radiographic contrast agents are used for diagnostic purposes and are one of the factors affecting measured values in bone density tests. They are absorbed into tissues and have an effect of increasing the measured values of bone density, so they are avoided as much as possible before performing a bone density test. MRI contrast agents, which have different physical properties and mechanisms of action than radiographic contrast agents, are based on gadolinium, a metal element. They have radiopacity characteristics, so MRI are generally performed prior to examination using radiation. The purpose of this study was to investigate the effects of MRI contrast agents on bone mineral density examination using dual energy X-ray absorption. Two types of gadolinium based MRI contrast agents were injected into an acrylic water tank for each volume, and the humanoid spine phantom was inserted and the BMD and T-score from (L1-L4) were analyzed by scanning a total of 30 times, 5 times for each injection type. The average value of the measured total (L1-L4) bone density for each of the two contrast agents was 0.952±0.052, 0.957±0.050, and 0.956±0.05g/㎠, respectively, for the Gadoterate Meglumine component 0mL, 7.5mL and 15mL, when the gadobutrol components were 0mL, 5mL, and 10mL, there was no statistically significant difference at all sites at 0.953±0.001, 0.954±0.001, and 0.945±0.001g/㎠, respectively(p>0.05). The average value of total T-score was -0.46±0.05, -0.4±0, -0.42±0.04 when the Gadoterate Meglumine component was 0mL, 7.5mL and 15mL, respectively. When the Gadobutrol ingredients were 0mL, 5mL and 10mL, there was no statistically significant difference in all areas, with -0.46±0.05, -0.46±0.05, and 0.5±0.00, respectively. In this experiment, the MRI contrast agent was found to have no effect on bone density tests, using the dual-energy X-ray absorption method. There is a limitation in that physical conditions such as kidney and health conditions etc. were not taken into consideration, so further clinical research is expected to be conducted in the future.