• 제목/요약/키워드: Water Supply Equipment System

검색결과 74건 처리시간 0.028초

수도사업장 고조파 측정, 분석을 통한 관리기준 만족여부 조사 (To examine of management standard by the harmonics measured and analyzed in water supply field)

  • 홍성택;이은춘;신강욱;임재일
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 A
    • /
    • pp.296-298
    • /
    • 2003
  • At the water supply field, high voltage induction motor is main facility of a load equipment. The motor is often out of order and its noise, generated heat, loss etc occured occasionally. especially, transmission motor for flux control generates an amount of the harmonics then have a bad influence upon the electric power system. In this study, to analyze the total harmonics distortion of the water supply field receiving high voltage, the harmonics measured and analyzed using the PQA(Power Quality Analyzer) according to the electric power system and electrical load and the reduction method presented.

  • PDF

효과적인 소방활동을 위한 지하주차장 스프링클러설비 송수배관 연결방식의 개선에 관한 연구 (A Study on Improvement of Connection Method of Underground Parking Lot SP Equipment Water Supply Pipe for Effective Fire Activities)

  • 손개성;최지훈;최돈묵
    • 대한안전경영과학회지
    • /
    • 제17권4호
    • /
    • pp.161-169
    • /
    • 2015
  • A fire sprinkler system is very important to extinguish fire in the building. The sprinkler system initiates sprinkler discharge if the detection system identifies a developing fire and opens the pre-action valve. However, pre-action fire sprinkler systems mainly installed in the underground parking lot at the apartment complex do not properly operate at fire if the connection type of fire sprinkler systems does not properly installed and operated. This study identified the relationship between fire dispersion & damage and the connection type of water supply in the sprinkler system from many fire cases at the apartment complex in South Korea. In addition, this study also identified the water supply differences and characteristics between South Korea and foreign countries. The main purpose of this study is also to improve the water connection types in the sprinkler system that can reduce the potential failures of pre-action valve operation through electrical signal system. The study also suggests the improvement plan for water connection types in pre-action fire sprinkler system that can minimize potential failure of pre-action fire sprinkler system. The suggestions for revising the fire safe standard in South Korea includes letting the water supply pipe of sprinkler system water inlet connect to the second side of pre-action valve and the water flow device that can minimize potential failure of sprinkler system.

댐 및 수도 사무소 감시제어시스템의 체계적 기술평가 방안 (The Systematic Evaluation of the SCADA System Proposals for Multi-purpose Dam and Water Supply Office)

  • 백두현;이은웅;김성헌
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 A
    • /
    • pp.217-219
    • /
    • 1998
  • Korea Water Resources Corporation (KOWACO) annually supplies about 2 billion Kwh and 7.3 billion $m^3$ with its 10 multi purpose dams and 20 water supply offices. For the proper control and management of the above utilities, sequential control equipment and SCADA/DCS have been operated and maintained. In this paper, 8 control system evaluations for hydropower dam, water supply, electric power and subway projects during 1984-1997 were reviewed and analyzed. The systematic evaluation method has been established in the points of the purpose, method, procedure, evaluation team, evaluation criteria, total evaluation table and the contents of final recommendation report. With keeping in mind the essential points, it is expected for the more effective and fair evaluation of bids.

  • PDF

석유화학공장의 소화설비에 관한 연구 (A Study on the Firefighting Equipment in Petrochemical Plants)

  • 김봉훈;최재욱;임우섭
    • 한국화재소방학회논문지
    • /
    • 제28권5호
    • /
    • pp.14-22
    • /
    • 2014
  • 석유화학공장에서 화재 폭발사고는 매년 반복되고 있으나 화재 방호시스템에 관한 국내 법규는 최악의 화재 시나리오에 대응하기에는 미흡한 실정이다. 이에 본 연구에서는 석유화학공장에서 국내외 화재 방호시스템의 기준을 비교 분석하고 울산국가산업단지 석유화학공장 32개소의 소화설비 현황을 조사하였다. 결론적으로 석유화학공장에서 소화용수는 최악의 화재 시나리오를 기반으로 하여 설계하고 고정식 물분무 설비, 고가 모니터 노즐, 워터커튼 설비, 대용량 포모니터 설비와 같은 소화설비가 최악의 화재 시나리오에 대비하여 설치되어야 할 것으로 나타났다.

감압밸브의 설계 및 유동해석 (Design and Computational Fluid Dynamics of Pressure Reducing Valve)

  • 이종선
    • 한국산학기술학회논문지
    • /
    • 제13권7호
    • /
    • pp.2853-2857
    • /
    • 2012
  • 본 논문은 급수 설비시스템의 적정수압을 유지하는 장치로 사용되는 감압밸브(Pressure Reducing Valve)의 구조와 특성을 알아보기 위해 3차원 자동 설계프로그램인 Solidworks를 활용하여 설계하였으며 현장에서 감압밸브의 제작을 위해 2차원 도면을 작성하였다. 또한 감압밸브내의 물의 흐름을 해석하기 위하여 3차원 유한요소해석 코드인 ANSYS를 사용하여 유동해석을 실시하였다.

22.9kV 수용가 전력계통별 고조파 발생실태 및 관리기준 조사분석 (to examine of management standard by the harmonics measured and analyzed in 22.9kV Power lines)

  • 이은춘;신강욱;홍성택;홍영재;박영춘;임재일
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 A
    • /
    • pp.270-272
    • /
    • 2004
  • At the water supply field, high voltage induction motor is main facility of a load equipment. The motor is often out of order and its noise, generated heat, loss etc occurred occasionally. especially, transmission motor for flux control generates an amount of the harmonics then have a bad influence upon the electric power system. In this study, to analyze the total harmonics distortion of the water supply field receiving high voltage, the harmonics measured and analyzed using the PQA(Power quality Analyzer) according to the electric power system and electrical load and the reduction method presented.

  • PDF

냉방시스템의 운전조건에 따른 에너지 소비특성 연구 (The Characteristics of Energy Consumption with Operational Conditions for the Central Cooling System)

  • 박기태;안병천
    • 한국지열·수열에너지학회논문집
    • /
    • 제15권4호
    • /
    • pp.39-45
    • /
    • 2019
  • The operational conditions such as cooling tower water pump flow rate, cooling tower fan flow rate, and chiller capacity in heat source equipment, and supply air temperature and chilled water temperature in air conditioner are considered to study the effects on energy consumption for central cooling system by using TRNSYS program. As a result, the optimal values of supply air temperature and chilled water temperature for minimal total energy consumption are 12℃ and 8℃. And if maximum values of cooling tower water pump and fan flow rate is decreased from 100% to 40%, energy consumptions are increased 170MJ/day and 63.2MJ/day, respectively.

탈이온수의 압력과 정제된 $N_2$가스가 ILD-CMP 공정에 미치는 영향 (Influence of DI Water Pressure and Purified $N_2$Gas on the Inter Level Dielectric-Chemical Mechanical Polishing Process)

  • 김상용;이우선;서용진;김창일;장의구
    • 한국전기전자재료학회논문지
    • /
    • 제13권10호
    • /
    • pp.812-816
    • /
    • 2000
  • It is very important to understand the correlation of between inter dielectric(ILD) CMP process and various facility factors supplied to equipment to equipment system. In this paper, the correlation between the various facility factors supplied to CMP equipment system and ILD-CMP process was studied. To prevent the partial over-polishing(edge hot-spot) generated in the wafer edge area during polishing, we analyze various facilities supplied at supply system. With facility shortage of D.I water(DIW) pressure, we introduced an adding purified $N_2$(P$N_2$)gas in polishing head cleaning station for increasing a cleaning effect. DIW pressure and P$N_2$gas factors were not related with removal rate, but edge hot-spot of patterned wafer had a serious relation. We estimated two factors (DIW pressure and P$N_2$gas) for the improvement of CMP process. Especially, we obtained a uniform planarity in patterned wafer and prohibited more than 90% wafer edge over-polishing. In this study, we acknowledged that facility factors supplied to equipment system played an important role in ILD-CMP process.

  • PDF

유입식 변압기의 상태진단을 통한 노후도 평가 방법 (A Study on Deterioration Evaluation Method by Condition Monitoring and Diagnosis for Aging Oil-immersed Power Transformers)

  • 장정호;이성훈;이흥호
    • 전기학회논문지
    • /
    • 제63권2호
    • /
    • pp.297-305
    • /
    • 2014
  • Nowadays new water supply projects have been on the decline as the water-power constructions have saturated, which means that the existing power equipment have slowly aged and they require more efforts to maintain the system performance. An effective asset management method of power equipment has become a great necessity from both economical and technical aspects. To be balanced, the asset management should look into all three parts: management, engineering, and information. The purpose of this paper is to study a Risk-Based Maintenance (RBM) matrix method through the deterioration evaluation algorithm for an efficient reliability assessment of oil-immersed power transformers by considering both asset management and technical evaluation. Make use of this result, the equipment will be decided to be replace or repair otherwise on service.

콤팩트형 태양열/지열히트펌프 하이브리드 냉난방 및 급탕 시스템 개발 및 성능분석 (The Development and Performance Analysis of Compact Type Solar Thermal/Ground Coupled Heat Pump Hybrid System for Heating, Cooling and Hot water)

  • 백남춘;정선영;윤응상;이경호
    • 한국태양에너지학회 논문집
    • /
    • 제32권5호
    • /
    • pp.59-67
    • /
    • 2012
  • In this study,the compact type solar thermal and ground coupled heat pump hybrid system for space heating/cooling and hot water supply has been developed. This hybrid system was installed in Zero Energy Solar House(ZeSH) in KIER for the demonstration. The thermal performance and operational characteristics of this hybrid system were analysed especially. The results are as follows. (1) This hybrid system was designed in order to address the existing disadvantages of solar thermal/ground coupled heat pump system. For this design, all parts except solar collector and ground coupled heat pump were integrated into a single product in a factory. The compact type unit includes two buffer tanks, an expansion tank, pumps, valves, a controller, etc. This system has an advantage of easy installation with simple plumbing work even in narrow space. (2) The thermal charging and discharging time of the buffer tanks and its characteristics by ground coupled heat pump, and heat pump COP according to geo-source temperature and buffer storage temperature have been studied. This system was found to meet well to the heat load without any other auxiliary heating equipment. (3) The operating hours of the ground coupled heat pump as a backup device of solar thermal can be reduced significantly by using solar heat. It was also found that the minimum heating water supply setting temperature and maximum cooling water supply setting temperature make an influence on the heat pump COP. The lower heating water and the higher cooling water temperature, the higher COP. In this respect, the hybrid system's performance can be improved in ZeSH than conventional house.