• Title/Summary/Keyword: Water Saving Effect

검색결과 132건 처리시간 0.022초

공동주택 건물의 상수도 절감량에 따른 CO2 배출량 저감효과에 관한 연구 (A Study on the CO2 Emission Reduction Effect relating to the Water Usage Reduction in Multi-family Residential Building)

  • 조수현;강혜진;이언구
    • 한국태양에너지학회 논문집
    • /
    • 제31권5호
    • /
    • pp.126-133
    • /
    • 2011
  • The current world wide interest in environmental issues has moved from energy conservation to $CO_2$emission reduction. Recently, according to the increase in demand for water resources, insufficient potable water circumstance is supposed, unless there are corresponding in crease in water conservation and water recycling. This study has attempted to analyze $CO_2$emission reduction by water saving strategies like installation water saving devices, rain water harvesting and grey water system. To do this, this research investigates applicable water conservative strategies by literature review and calculated total water saving. The results show that (1) firstly, the water usage and $CO_2$ emission could be reduced up to 44%, (2) $CO_2$ emission reduction by water saving devices and rainwater harvesting system is about 47.7%, and (3) water usage and $CO_2$ emission reduction by grey water system is about 66%. In the future, this paper will be utilized for water management from the early design stage to maintenance stage of water glutton building.

실내수영장의 에너지 소비요소별 에너지 절약효과에 관한 연구 (A Study on the Energy Conservation Effect of Each Energy Consumption Component In Indoor Swimming Pools)

  • 김영돈;권규동;여명석;김광우
    • 설비공학논문집
    • /
    • 제14권12호
    • /
    • pp.1092-1101
    • /
    • 2002
  • The objective of this study is to develop energy saving strategies for indoor swimming pools and to estimate the effect of each energy saving strategy. For this purpose, field measurements regarding pool water heating energy, domestic hot water heating energy are conducted and a base energy consumption model is implemented using the DOE-2.1E program. The results of the study reveal that 25% of the total pool water heating energy may be saved by using night time pool covers, 27% of the total domestic hot water heating energy may be saved by using a waste water heat recovery system (effic. 60%), and of the total ventilation energy may be saved using an exhaust air heat recovery system (effic. 60%).

수조식 양식장의 태양광발전시스템 리모델링 교체 효과: 시뮬레이션을 통한 에너지절감효과 분석 (The Effect of Remodeling Replacement of Photovoltaic Power Generation System in Fish Farm : Analysis of Energy Saving Effect through Simulation)

  • 최현석;나종혁;이현영;노재엽
    • Current Photovoltaic Research
    • /
    • 제9권1호
    • /
    • pp.11-16
    • /
    • 2021
  • In the past, marine pollution caused by radioactivity and wastewater discharge caused mass destruction. As an alternative, the land farming system became common and operational. In recent years, safety and environmental problems caused by declining population due to aging of fishermen and underdeveloped facilities have always been lurking, so improvement is urgently needed. As part of the new renewable energy 3020 plan announced by the government in 2017, a new model was proposed to improve the environment as well as save energy when the roof of a water tank farm was remodeled into a solar power system. Study, when the existing roof was remodeled and replaced with a water tank farm in Busan as an empirical model, the energy saving rate was analyzed by comparing the actual electricity consumption and power generation.

해수 열원 히트펌프와 태양광 발전을 이용한 순환여과식 양식장의 에너지 절감 효과 분석 (Analysis of energy-saving effects of recirculation aquaculture system using seawater source heat pumps and solar power generation)

  • 류종혁;정현석;정석권
    • 수산해양기술연구
    • /
    • 제60권2호
    • /
    • pp.194-206
    • /
    • 2024
  • This study focuses on analyzing the energy-saving effects of the recirculation aquaculture system using seawater source heat pumps and solar power generation. Based on the thermal load analysis conducted using the transient system simulation tool, the annual energy consumption of the recirculation aquaculture system was analyzed and the energy-saving effects of utilizing the photovoltaic system was evaluated. When analyzing the heat load, the sea areas where the fish farms are located, the type of breeding tank, and the circulation rate of breeding water were taken into consideration. In addition, a method for determining the appropriate capacity for each operation time was examined when applying the energy storage system instead of the existing diesel generator as an emergency power, which is required to maintain the water temperature of breeding water during power outage. The results suggest that, among the four seas considered, Jeju should be estimated to achieve the highest energy-saving performance using the solar power generation, with approximately 45% energy savings.

In-Situ Diagnosis of Vapor-Compressed Chiller Performance for Energy Saving

  • Shin Younggy;Kim Youngil;Moon Guee-Won;Choi Seok-Weon
    • Journal of Mechanical Science and Technology
    • /
    • 제19권8호
    • /
    • pp.1670-1681
    • /
    • 2005
  • In-situ diagnosis of chiller performance is an essential step for energy saving business. The main purpose of the in-situ diagnosis is to predict the performance of a target chiller. Many models based on thermodynamics have been proposed for the purpose. However, they have to be modified from chiller to chiller and require profound knowledge of thermodynamics and heat transfer. This study focuses on developing an easy-to-use diagnostic technique that is based on adaptive neuro-fuzzy inference system (ANFIS). The effect of sample data distribution on training the ANFIS is investigated. It is found that the data sampling over 10 days during summer results in a reliable ANFIS whose performance prediction error is within measurement errors. The reliable ANFIS makes it possible to prepare an energy audit and suggest an energy saving plan based on the diagnosed chilled water supply system.

정수압방식 동력회수장치의 구동동력 절감량 해석 (An analysis on power regeneration of hydrostatic pressure exchanger)

  • 함영복;최준혁;정헌술;박상진;박중호;윤소남
    • 유공압시스템학회논문집
    • /
    • 제4권3호
    • /
    • pp.7-12
    • /
    • 2007
  • This paper presents an energy saving hydrostatic pressure exchanger for sea water desalination equipment. In a reverse osmosis(RO) system for desalinating sea water, more than 70 percent of the supplied sea water, brines which were impassable through RO membrane are bypassed, resulting in high energy losses. In this paper, a hydrostatic pressure exchanger consisting of an embedded water hydraulic piston motor and a water hydraulic piston pump was proposed and investigated in order to recover the energy of the bypassed brines. The pressurized brines are supplied to the embedded water hydraulic piston motor as power sources and the water hydraulic piston pump is driven by the output torque of the embedded water hydraulic piston motor as well as electric motor. Consequently, the energy of the bypassed brines can be recovered. To examine the electric energy saving characteristics of the hydrostatic pressure exchanger, a simulation model was constructed using commercial software and experiments were conducted. Through the results of simulation and experiment, the feasibility of the electric energy saving effect of the proposed hydrostatic pressure exchanger was investigated.

  • PDF

전기적 열제어 시스템을 사용한 에너지 소비량 감소에 관한 연구 (A study on the saving of energy consumption load using electrical heat control system)

  • 한규일
    • 수산해양기술연구
    • /
    • 제49권1호
    • /
    • pp.58-66
    • /
    • 2013
  • Most of steam power plant in Korea are heating the feed water system to prevent freezing water flowing in the pipe in winter time. The heating system is operated whenever the ambient temperature around the power plant area below 5 degree Centigrade. But this kind of heat supplying system cause a lot of energy consuming. If we think about the method that the temperature of the each pipe is controled by attaching the temperature measuring sensor like RTD sensor and heat is supplied only when the outer surface temperature of the pipe is under 5 degree Centigrade, then we can save a plenty of energy. In this study, the computer program package for simulation is used to compare the energy consumption load of both systems. Energy saving rate is calculated for the location of Youngweol area using the data of weather station in winter season, especially the January' severe weather data is analyzed for comparison. Various convection heat transfer coefficients for the ambient air and the flowing water inside the pipe was used for the accurate calculation. And also the various initial flowing water temperature was used for the system. Steady state analysis is done previously to approximate the result before the simulation. The result shows that the temperature control system using RTD sensor represents the high energy saving effect which is more than 90% of energy saving rate. Even in the severe January weather condition, the energy saving rate is almost 60%.

물 재이용에 대한 인식이 물 재이용 실천의도에 미치는 영향 (A Study on the Effect of the Perception of Water Reuse on Water Reuse Practice Intention)

  • 임상호;한무영
    • 산업진흥연구
    • /
    • 제1권1호
    • /
    • pp.137-142
    • /
    • 2016
  • 물 재이용에 대한 인식이 물 재이용 실천의도에 미치는 영향을 검증하였다. 연구결과 물 재이용 절수제품 구매의도에 유의한 영향을 미치는 요인은 물 재이용 실천 필요성 인식, 세면수 재활용 양변기 효과 인지도(p<.01), 공공기관 절수제품 의무설치 인식, 절수제품 의무설치 대상 확대 찬성도, 물 재이용 법률 인지도(p<.05)로 나타났다. 또한 월평균 가구소득이 150만원 이하인 경우, 직업이 전문가 및 관련 종사자와 판매 및 기능 종사자인 경우, 월평균 수도요금이 4만원대 이상인 경우 물 재이용 절수제품 구매의도가 상대적으로 높은 집단 간 차이가 나타났다. 본 연구는 물 재이용에 대한 인식이 물 재이용 실천의도에 미치는 영향을 분석함으로써 물 재이용 실천율을 높이기 위한 물 재이용 정책 추진방향에 시사점을 제공한 데 그 의의가 있다.

중앙냉난방시스템의 EMS 복합제어 효과 분석에 관한 시뮬레이션 연구 (A Simulation Study on Effect Analysis of EMS Combined Control of Central Cooling and Heating System )

  • 송재엽;안병천
    • 한국지열·수열에너지학회논문집
    • /
    • 제18권4호
    • /
    • pp.33-44
    • /
    • 2022
  • In this study, we analyze the existing heating and cooling operation method for an office-type complex building with a central heating and cooling system, and examine the effects of applying various EMS that can be applied according to the load size to save energy in the building. For this purpose, simulation analysis was performed. As a control method, reset control of chilled water, hot water, cooling water and supply air temperatures, optimal start/stop of heat source, and number of heat source control were applied according to the load size, and energy consumption was analyzed accordingly. In addition, when all of these control methods were applied, the overlapping energy saving effect was finally confirmed. As a result, it was possible to confirm the energy saving effect when EMS for reset control and heat source control were applied compared to the existing control method of the heating and cooling system, and the effect for the case of using all these control methods in combination was also confirmed.

A Water-saving Irrigation Decision-making Model for Greenhouse Tomatoes based on Genetic Optimization T-S Fuzzy Neural Network

  • Chen, Zhili;Zhao, Chunjiang;Wu, Huarui;Miao, Yisheng
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • 제13권6호
    • /
    • pp.2925-2948
    • /
    • 2019
  • In order to improve the utilization of irrigation water resources of greenhouse tomatoes, a water-saving irrigation decision-making model based on genetic optimization T-S fuzzy neural network is proposed in this paper. The main work are as follows: Firstly, the traditional genetic algorithm is optimized by introducing the constraint operator and update operator of the Krill herd (KH) algorithm. Secondly, the weights and thresholds of T-S fuzzy neural network are optimized by using the improved genetic algorithm. Finally, on the basis of the real data set, the genetic optimization T-S fuzzy neural network is used to simulate and predict the irrigation volume for greenhouse tomatoes. The performance of the genetic algorithm improved T-S fuzzy neural network (GA-TSFNN), the traditional T-S fuzzy neural network algorithm (TSFNN), BP neural network algorithm(BPNN) and the genetic algorithm improved BP neural network algorithm (GA-BPNN) is compared by simulation. The simulation experiment results show that compared with the TSFNN, BPNN and the GA-BPNN, the error of the GA-TSFNN between the predicted value and the actual value of the irrigation volume is smaller, and the proposed method has a better prediction effect. This paper provides new ideas for the water-saving irrigation decision in greenhouse tomatoes.