• 제목/요약/키워드: Water Quality Measurement

검색결과 533건 처리시간 0.032초

Mapping Water Quality of Yongdam Reservoir Using Landsat ETM Imagery

  • Kim, Tae-Keun;Cho, Gi-Sung;Kim, Kwang-Eun
    • 대한원격탐사학회지
    • /
    • 제18권3호
    • /
    • pp.141-146
    • /
    • 2002
  • Chlorophyll-a concentration maps of Yongdam reservoir in September and October, 2001 were produced using Landsat ETM imagery and the in-situ water quality measurement data. In-situ water samples were collected on 16th September and 18th October during the satellite overpass. The correlations between the DN values of the imagery and the values of chlorophyll-a concentration were analyzed. The visible bands(band 1, 2, 3) and the near infrared band(band 4) data of September image showed the correlation coefficient values higher than 0.9. The October image showed correlation coefficient values of about 0.7 due to the low variations of chlorophyll-a concentration. Regression models between the DN values of the Landsat ETM image and the chlorophyll-a concentration have been developed for each image. The developed regression models were then applied to each image, and finally the chlorophyll-a distribution maps of Yongdam reservoir were produced. The produced maps showed the spatial distribution of the chlorophyll-a in Yongdam reservoir in a synoptic way so that the tropic state could be easily monitored and analysed in the spatial domain.

Modified Gas Tracer Method를 이용한 하천의 재폭기계수 (Field Measurement Methods of Stream Reaeration Coefficient - Modified Gas Tracer Method -)

  • 조영준;권순국
    • 한국농공학회:학술대회논문집
    • /
    • 한국농공학회 1998년도 학술발표회 발표논문집
    • /
    • pp.547-551
    • /
    • 1998
  • Reaeration coefficient is the physical absorption of oxygen from the atmosphere by water. It is the most important natural means by which a stream replaces the oxygen consumed in the biodegradation of organic wastes, and the rate constant describing this process is the reaeration coefficient, It. Reaeration coefficient is the dominant parameter affecting the use of water quality model. Therefore accurate estimation of the reaeration coefficient is essential for optimum water quality management. There is several method to estimate stream reaeration coefficient. In this study, it would be concluded that SI-peak method is of practical use when applied to small stream, and CRI method is adequate to large stream.

  • PDF

배전계통에 연계된 풍력발전기 운영특성 분석 (Power Quality Analysis of Wind Power System interconnected with Distribution Networks)

  • 김현한;김광호;전정표;옥연호;곽희진;장진승
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2011년도 제42회 하계학술대회
    • /
    • pp.1338-1339
    • /
    • 2011
  • Recently the wind turbine generating systems are increasing world widely. This type of systems will change the nation's energy environment which largely depends on the fossil fuels. It will also bring new problems to the power industry and the customers. The expected problem is the voltage and frequency stability of the power distribution network, when a wind turbine generating system is connected to the line. It becomes necessary and important to evaluate their impact on the electrical network stability. This paper shows the electrical data measurement and analysis of a inductive wind turbine generator affecting the power quality problem of the distribution line.

  • PDF

보령담수호 유역의 유출 오염부하량 추정 (Estimation of Runoff Pollutant Loadings in Boryung Reservoir Watershed)

  • 최진규;손재권;구자웅;조재영;김영주
    • 한국농공학회:학술대회논문집
    • /
    • 한국농공학회 2001년도 학술발표회 발표논문집
    • /
    • pp.30-33
    • /
    • 2001
  • This study was carried out to estimate the runoff pollutant loadings for water quality management in Boryung freshwater reservoir watershed. The hydrological monitoring system were operated for water level measurement during $1999{\sim}2000$ and temporal variation of water quality constituents such as pH, EC, total nitrogen, total phosphorus were analysed, periodically. Monthly runoff volumes by TANK model and potential pollutant loadings calculated by unit method were compared with measured values.

  • PDF

갈수기 소하천에서 희석유량법을 이용한 유량측정의 적용성 검토 (Investigation for Streamflow Measurement of Small Stream using Dilution Discharge Method during Low Flow Season)

  • 김기형;김정곤;이상욱
    • 한국습지학회지
    • /
    • 제8권4호
    • /
    • pp.59-67
    • /
    • 2006
  • 본 연구에서는 갈수기 소하천에서 하천의 수질농도를 이용하여 하천의 유량을 측정할 수 있는 희석법을 적용하고 유속계를 이용한 유량측정법과 비교하였다. 본 연구에서 희석법에 의한 유량산정방법을 충북 보은의 내속하수처리장을 중심으로 갈수기에 조류 발생 하천인 달천에 대해 적용한 결과 유속단면적법에 의해 측정된 유량과 평균 $0.004m^3/sec$의 차이를 보였다. 본 연구에서 적용된 희석법에 의한 유량측정방법은 향후 다양한 상황에서 검증을 거쳐, 갈수기 소하천에서 조류 발생 등의 원인 규명을 위해 신속하게 유량을 측정할 필요가 있는 경우에 적용될 수 있을 것이다. 특히, 위어 등의 측정설비가 없거나 유속계를 사용할 수 없을 정도로 수심이 작은 경우, 그리고 유속계 등의 장비가 없는 경우, 또는 하천의 단면을 확실히 알지 못하는 경우 등 유량측정이 용이하지 않은 경우에 효과적으로 활용될 수 있을 것이다.

  • PDF

Development of a smart rain gauge system for continuous and accurate observations of light and heavy rainfall

  • Han, Byungjoo;Oh, Yeontaek;Nguyen, Hoang Hai;Jung, Woosung;Shin, Daeyun
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 2022년도 학술발표회
    • /
    • pp.334-334
    • /
    • 2022
  • Improvement of old-fashioned rain gauge systems for automatic, timely, continuous, and accurate precipitation observation is highly essential for weather/climate prediction and natural hazards early warning, since the occurrence frequency and intensity of heavy and extreme precipitation events (especially floods) are recently getting more increase and severe worldwide due to climate change. Although rain gauge accuracy of 0.1 mm is recommended by the World Meteorological Organization (WMO), the traditional rain gauges in both weighting and tipping bucket types are often unable to meet that demand due to several existing technical limitations together with higher production and maintenance costs. Therefore, we aim to introduce a newly developed and cost-effective hybrid rain gauge system at 0.1 mm accuracy that combines advantages of weighting and tipping bucket types for continuous, automatic, and accurate precipitation observation, where the errors from long-term load cells and external environmental sources (e.g., winds) can be removed via an automatic drainage system and artificial intelligence-based data quality control procedure. Our rain gauge system consists of an instrument unit for measuring precipitation, a communication unit for transmitting and receiving measured precipitation signals, and a database unit for storing, processing, and analyzing precipitation data. This newly developed rain gauge was designed according to the weather instrument criteria, where precipitation amounts filled into the tipping bucket are measured considering the receiver's diameter, the maximum measurement of precipitation, drainage time, and the conductivity marking. Moreover, it is also designed to transmit the measured precipitation data stored in the PCB through RS232, RS485, and TCP/IP, together with connecting to the data logger to enable data collection and analysis based on user needs. Preliminary results from a comparison with an existing 1.0-mm tipping bucket rain gauge indicated that our developed rain gauge has an excellent performance in continuous precipitation observation with higher measurement accuracy, more correct precipitation days observed (120 days), and a lower error of roughly 27 mm occurred during the measurement period.

  • PDF

고기능성 투습방수 소재의 저온굴곡 시험방법 개선 연구 (A Study on Improvement of the low temperature flex resistance test method about high waterproof materials)

  • 이민희;문선정;고혜지;홍성돈
    • 품질경영학회지
    • /
    • 제46권3호
    • /
    • pp.425-440
    • /
    • 2018
  • Purpose: This study is aimed at developing of the flex resistance testing process at low temperature with the waterproof fabric to suit the military environment, and is designed to fit for the purpose of the waterproof materials in order to optimize the test method by finding out matters to improve from existing the test method and through previous studies. Methods: The test method, which has been applied to flex resistance of existing water-repellent materials, was improved and consequently, differentiated test results could be obtained according to the test temperature, sample size, and flexing method. Results: The testing of the total of 8 samples revealed that performance of the military requirement could hardly be met just by presenting the materials or 2~3 layers when the quality criteria for high functional water repellent fabrics were applied. PTFE(Polytetrafluoroethylene) is preferred to PU(Polyurethane) to be used in the extremely low-temperature environment, but durability under the low-temperature environment may be varied depending on film thickness or laminating technique even if the materials of waterproof films are identical. Therefore, in addition to the material or texture, the test method capable of reflecting durability under the low-temperature environment shall be suggested, and the newly designed test method proposed in this study was shown to suggest differentiated quality criteria by the material. Conclusion: The water resistance measurement and the test method following flex resistance with expanded range of flex will enable the differentiable test of the samples according to the number of repetition. This study is meaningful in that it suggests a differentiable test method capable of establishing a basis of deciding suitable material when selecting military goods made of water repellent material by properly improving the test method.

내륙 수온과 MODIS 지표 온도 데이터의 비교 평가 (Comparison of MODIS Land Surface Temperature and Inland Water Temperature)

  • 나유경;김주원;임은하;박우정;김민준;최진무
    • 한국지역지리학회지
    • /
    • 제19권2호
    • /
    • pp.352-361
    • /
    • 2013
  • 기상 현상을 예측하는 수치예보모델의 주요한 기초 입력 데이터로 토지이용, 지형, 식생, 지표 온도 등이 있다. 이 중 지표 온도의 일부인 내륙 수면 온도에 대한 지상 관측 데이터는 강이나 호수의 일부 지역에만 존재한다. 따라서 본 연구는 수치예보모델의 입력 데이터인 내륙 수면 온도로 활용할 수 있는 MODIS 위성영상의 지표 온도 데이터의 오차정도를 확인하기 위해 국내 내륙 수온 지상 관측 데이터와 비교 분석하였다. 이를 위해 2011년 7월부터 2012년 6월까지 약 1년의 MODIS Land Surface Temperature(LST) 데이터와 수질자동측정망의 수온 데이터를 비교하였다. MODIS 데이터는 주간 및 야간 데이터로 구성되는 데, 각각의 월 평균 오차는 $2^{\circ}{\sim}8^{\circ}C$, $3^{\circ}{\sim}12^{\circ}C$로 주간 데이터의 오차가 작았다. 특히, 주간 데이터의 오차는 가을에 $2^{\circ}C$로 다른 계절에 비해 작았고, 야간 데이터는 여름에 $3^{\circ}C$로 다른 계절에 비해 작았다. 또한 지역적으로는 한강, 낙동강, 금강, 영산강의 4대강을 비교한 결과 가장 남쪽에 있는 영산강 유역에서 가장 오차가 작았다. 본 연구를 통해 수치예보모델의 입력 데이터로 활용함에 있어 MODIS 지표 온도 데이터의 오차 정도를 확인할 수 있었다. 연구 결과는 아시아 지역에 대해 수치예보모델을 운용할 때 북한 및 해외 지역에 대해 MODIS 지표 온도 데이터를 활용함에 있어 그 오차 정도의 기준이 될 수 있을 것이다.

  • PDF

자동측정망 데이터를 활용한 국내 호소 실시간 수질지수 평가 (RTWQI(Real Time Water Quality Index) evaluation of domestic lakes using automatic measurement network data)

  • 김선웅;홍은미
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 2022년도 학술발표회
    • /
    • pp.174-174
    • /
    • 2022
  • 수질지수는 여러 수질 데이터 값을 수학적으로 결합하고 다 변수 특성을 줄여 수치 및 등급으로 나타낸 지표이다. 수질지수를 통해 수질을 평가하고 서로 다른 위치와 시간의 수역을 종합적으로 비교할 수 있으며 수자원관리에 있어 정책입안자, 의사결정자, 국민이 수질에 대해 일반적이고 쉽게 이해할 수 있다. 현재 환경부에서는 국내수질자동측정망 최근 12시간 데이터 값을 근거로 실시간수질지수 RTWQI(Real-Time Water Quality)값을 제공한다. 국내 호소에 설치된 수질 자동측정망은 총 8개소이며 매 시간 공통 항목인 수온, pH, DO, 전기전도도, TOC 5개, 선택항목인 탁도, Chl-a, TN, TP, 중금속, 생물감시항목 등 27개를 측정한다. RTWQI는 캐나다에서 2001년에 개발된 CCME WQI(Canadian Council of Ministers of the Environment Water Quality Index) 산출식을 기초하였으며 F1(기준치를 위반하는 수질항목의 개수/ 총 수질항목 개수), F2(기준치를 위반한 샘플들의 총 횟수/총 샘플횟수) F3(기준치를 위반한 정도) 3가지의 요소로 계산된다. 그러나RTWQI 산출식의 기초인 CCME WQI는 개발 이후 여러 문제점들은 개선되었으나 F1이 다른 F2, F3 보다 CCME WQI 점수의 기여도가 2배 이상 높은 문제점은 개선하지 못하였다. 본 연구에서는 수질자동측정망이 설치된 2012년 7월부터 2021년 12월 동안 매 시간 별 수질 데이터를 이용하였다. 또한 CCME WQI 문제점을 개선한 MWQI(Modification of Canadian water qaulity index)를 기초하여 실시간 수질지수를 재 산정하였다. 추가적으로 Pearson 상관관계 분석 및 추가 통계분석을 통해 환경부에서 제공하는 기존의 RTWQI, 개선된 실시간수질지수, 한국형 호소수질평가지수 LQI(Lake Water Quality Index)를 비교 및 평가하였다. 이러한 연구를 통해 정확성 높은 수질지수를 찾고 수자원 관리 정책 수립에 적극 활용 될 수 있을 것으로 사료된다.

  • PDF

Landsat 8 이미지영상을 이용한 영양염류농도 추정; 금강을 대상으로 (Estimation of Water Quality using Landsat 8 Images for Geum-river, Korea)

  • 임지상;백종진;김형록;최민하
    • 한국수자원학회논문집
    • /
    • 제48권2호
    • /
    • pp.79-90
    • /
    • 2015
  • 2013년 3월에 발사된 Landsat 8 인공위성의 이미지데이터를 이용하여 금강유역을 대상으로 수질인자에 대한 평가를 수행하였다. 본 연구의 목적은 다양한 수질인자 중 녹조에 직접적인 영향을 미치는 총질소와 총인의 농도를 추정함으로써 궁극적으로 수생태계에 악영향을 미치는 녹조의 발생을 모니터링 하는 것이다. 현장실측데이터와 인공위성 데이터간의 상관관계를 규명하기 위하여 Pearson' 상관계수를 이용하여 그 관계를 파악하였다. Landsat 8이 촬영되는 시기를 포함하는 총 20개의 현장실측 데이터가 수집되었으며 Landsat 8의 11개의 밴드중, 밴드2, 3, 4의 반사도 값이 총인과 총질소를 탐지하는데 있어서 가장 상관성 높은 것으로 나타났다. 총질소는 유의수준 0.05에서 밴드2(0.48), 3(0.62), 4(0.57)과 높은 양의 상관관계를 보였으며, 총인의 경우, 유의수준 0.01에서 밴드2(0.59), 3(0.59), 4(0.58)로 높은 양의 상관관계를 나타냈다. 5번 밴드는 유의수준을 벗어남으로써 두 수질인자를 탐지하는데 상관성이 떨어지는 것으로 나타났다. 상관성이 높았던 밴드간의 조합을 통해서 총질소와 총인에 대한 각각의 최적 회귀식이 다중 회귀식을 근거로 구축되었다. 유도된 회귀식으로 계산된 총질소와 총인의 농도값은 통계기법인 Bias와RMSE를 이용하여 현장실측데이터들과 비교 검증되었다. 최종적으로, 2014년 4월 21과 2013년 11월 12일에 대한 맵핑을 수행함으로써 총질소와 총인의 공간적인 분포를 시각적으로 확인할 수 있었다.