• Title/Summary/Keyword: Water Leakage Prevention

Search Result 42, Processing Time 0.043 seconds

Preventing disaster system of the subaqueous tunnel under the Han river in the Bundang railway (분당선 한강 하저터널의 방재시스템)

  • Kim Yong-Il;Hwang Nak-Yeon;Yoon Young-Hoon;Jie Hong-Keun;Jang Sung-Wook;Kim Dong-Hyun
    • Proceedings of the KSR Conference
    • /
    • 2004.10a
    • /
    • pp.308-327
    • /
    • 2004
  • As use of tunnels and subways increase there also are accidents proportionate to it. Daegu Subway Station fire, Hongjimoon tunnel fire led people to be conscious of disaster protection and as a result, there is a trend to adopt standards for fire protection. Accordingly, this thesis is focused on investigating various fire and water protection related issues for subaqueous tunnel under Ran river. The thesis developed evacuation and disaster prevention plan as fire level increases and have identified the suitability of disaster prevention through evacuation and fire simulation, countermeasure of a water leakage during construction and operation considering the subaqueous tunnel. And we selected EPB shield TBM equipment considering the ground condition and effect of boring hole, and accomplished reasonable water protection design through setting goals using event-tree method, as well as examining model test of boring hole and flooding in heavy rain. Also included structured total system consist of water leakage sensing system, water protection gate, pumping system and fire protection system to respond systematically in emergency.

  • PDF

해안매립지에서의 추적자시험 및 수위변화특성 연구

  • 이진용;황대규;이명재;최예권;김정우;이강근
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2002.04a
    • /
    • pp.221-224
    • /
    • 2002
  • To demonstrate prevention of the leachate leakage out of the landfill with creating inward hydraulic gradient, a tracer test and continuous waterlevel monitoring at the Inside and outside of the barrier wall of a costal landfill were peformed. When the tracers were injected into the well outside of the vertical wall system with high water level, then they were detected at the well inside of the system with low water level. Furthermore the lowered water level at the inside of the landfill than that at the outside prevented leachate leakage out of the landfill. This study reports results of the tracer test and waterlevel monitoring.

  • PDF

Leakage Situation and Main Leakage Areas of Domestic Residential Building Underground Parking Lots (국내 공동주택 지하주차장의 누수 실태 및 주요 누수 부위 조사)

  • Lee, Jung-Hun;Song, Je-Young;Oh, Sang-Keun
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.4 no.4
    • /
    • pp.496-503
    • /
    • 2016
  • This paper studies the leakage situation of domestic residential building underground parking lots and main leakage areas. 18 complexes were studied and the results showed that 80% of buildings with exterior waterproofing had no leakage, but all buildings with interior waterproofing had leakage. According to a survey among professionals, water leakage problems are considered to be severe in underground parking lots and a preventative measure is required by the government. By comparing the survey and the actual situation at hand, the results showed that the lowest floor slab, wall construction joints, and floor expansion joints were the most prone to leakage. Based on the results, further study to develop a design manual for the appropriate prevention of leakage is deemed necessary.

Physical Model Experiment on the Seepage Characteristics through a Dam by using FDR Sensor (FDR 센서를 활용한 제체 누수특성의 실내 모형 실험 연구)

  • Kim, Gyoo-Bum;Im, Eunsang;Ryu, Ho-Cheol;Hwang, Chan-ik;Kim, Hyeong-Jong
    • The Journal of Engineering Geology
    • /
    • v.28 no.4
    • /
    • pp.715-726
    • /
    • 2018
  • Various methods, such as geophysical exploration, temperature measurement, and fiber optics, have been developed for detecting the seepage at a dam. In this study, in order to investigate the possibility of leakage detection using dielectric constant of FDR sensor, a physical model consisting of weak and no-weak zones is fabricated and the sensors for dielectric constant, temperature and pore water pressure measurements are installed. As a leakage happens, the dielectric constant changes more rapidly through a weak zone than no-weak zone. In addition, comparing three factors (dielectric constant, temperature, and pore water pressure), the response of dielectric constant to seepage is fast and it is easily recognized even at the end measurement point. Considering these features, it is concluded that it could be possible to cope with the leakage detection quickly and efficiently if the dielectric constant is measured at the downstream slope of a dam.

Improvement of Cooling Water Quality by Corrosion and Scale Inhibitor (부식 및 스케일 억제제에 의한 냉각수 수질향상)

  • Jo, Kwan-Hyung;Woo, Dal-Sik;Hwang, Byung-Gi
    • Journal of Environmental Science International
    • /
    • v.18 no.2
    • /
    • pp.187-195
    • /
    • 2009
  • This study was investigated to control the corrosion and scale at the cooling water system in steel works. Laboratory and field tests were performed for the indirect cooling water system of plate mill. Throughout the experiment, various factors such as leakage of pipes, heating rate and capacity, and the reaction between existing and substitute inhibitors were carefully monitored. The results showed that the harmful effect of high temperature could be minimized, and satisfactory corrosion/scale controls were effectively achieved using inhibitor, even at the increased temperature of $80^{\circ}C$. The batch and field tests in the gas scrubbing cooling water system of blast furnace and cooling water system of corex plant indicated that the new inhibitor was more effective for the prevention of corrosion and scale than the existing one.

The Remote Wireless Corrosion Monitoring System for Water Pipeline (상수도 배관용 무선 원격 부식모니터링 시스템)

  • Ha, Tae-Hyeon;Bae, Jeong-Hyo;Lee, Hyeon-Gu;Ha, Yun-Cheol;Kim, Dae-Gyeong
    • Proceedings of the KIEE Conference
    • /
    • 2003.11c
    • /
    • pp.637-640
    • /
    • 2003
  • The owner of water pipeline has a burden of responsibility for the protection of corrosion and the prevention against leakage of water. So, they have been installed a CP(Cathodic Protection) System in oder to protect corrosion. And they also have been measured and analyzed the data about P/S(Pipe to Soil) potential of water pipeline. The P/S potential is basic data of evaluation for water pipeline corrosion. In this paper, results of development about remote wireless corrosion monitoring system for water pipe line are presented briefly.

  • PDF

The TRS Terminal for Wireless Remote Corrosion Monitoring System (무선 원격 부식모니터링용 TRS 단말기)

  • Ha, Tae-Hyeon;Bae, Jeong-Hyo;Lee, Hyeon-Gu;Ha, Yun-Cheol;Kim, Dae-Gyeong
    • Proceedings of the KIEE Conference
    • /
    • 2003.11c
    • /
    • pp.544-547
    • /
    • 2003
  • The owner of water pipeline has a burden of responsibility for the protection of corrosion and the prevention against leakage of water. So, they have been installed a CP(Cathodic Protection) System in odor to protect corrosion. And they also have been measured and analyzed the data about P/S(Pipe to Soil) potential of water pipeline. The P/S potential is basic data of evaluation for water pipeline corrosion. They need remote automatic corrosion monitoring system for easy maintenance. In this paper, The communication method was studied mainly. And the specifications of proposed TRS (Truncked Radio System ) terminal for corrosion monitoring are introduced briefly.

  • PDF

A Study on the lighting Installation Regulations in Waterpark, Public Bath and Similar Places for the Prevention of Electrical Shock (감전사고 방지를 위한 물놀이.입욕시설의 조명설비 시설규정 연구)

  • Kim, Chong-Min;Kim, Han-Sang;Kim, Gi-Hyun;Hwang, Kwang-Su
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2005.11a
    • /
    • pp.339-344
    • /
    • 2005
  • A person's body resistance in the waterpark, public bath and similar places is lower than any other places due to effect of water. So low voltage may create a shock hazard for the human body in case of leakage or fault currents from lighting unit etc. We researched the related regulations these are internal standards, NEC, IEC and investigated the actual conditions for the prevention of electrical shock due to lighting units in the waterpark, public bath and similar places. So we could present actual facilities's problems and solutions

  • PDF

Watertightness Property Evaluation of Rain-Block System (개폐식 대공간 구조물에서 지붕 맞댐부 우수차단 시스템의 수밀성 평가에 관한 연구)

  • Kim, Yun-Ho;Baek, Ki-Youl;Kim, Jong-Su;Lee, Sun-Gyu;Oh, Sang-Keun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2010.05a
    • /
    • pp.13-16
    • /
    • 2010
  • This study is an Investigation on the Watertightness Properties of Rain-Block System on the Sliding-Roof Joint of Large-Span Membrane Structures. In this experimental, we test the watertightness performance of joint part of sliding door in roof of large span membrane structure(for pilot project) under environment of rain and wind. A shape of rain water blocking systems of joint part in sliding door verifies the defects and effects of water leakage prevention in precipitation with the wind conditions. For obtaining watertightness of large span membrane structures, it is necessary quality of joints and performance, and quality of membrane material of a retractable roof as well as a closed roof. Also, for obtaining quality in joints, it is essential to make a watertightness guideline for design of large-span membrane.

  • PDF

A Study on the Improvement Directions and Case Analysis of Rural Tourism Development in Fiji (피지(Fiji)의 농촌관광개발 사례분석 및 개선방안 연구)

  • Hwang, Hancheol
    • Journal of Korean Society of Rural Planning
    • /
    • v.22 no.4
    • /
    • pp.13-24
    • /
    • 2016
  • Tourism is often considered as one of the main industries to promote development and modernization in small South Pacific islands countries. In Fiji, this was recognized in the 1960s, and resulted in large-scale resort based tourism development in coastal areas. While tourism has obvious advantages to the economy, a lot of problems such as exclusive foreign control of the main hotels and resorts, considerable overseas leakage of earnings, the limited participation by indigenous resource owners, and localized environmental damages to reefs and mangroves are emerging. For sustainable tourism development, it is needed to set growth objectives and targets for tourism in terms of benefits to Fiji, and to concentrate support on 'Rural Tourism' such as community-based tourism that have lower leakage and put more into local economies. Through case study in this paper, to develop rural tourism at the local level, several recommendations are as follows: 1) to introduce various rural tourism programs such as experiencing Fiji's traditional culture, participating in activities, picking fruits and harvesting agro-products, 2) to enhance aggressive promotion and marketing strategies, 3) to build the capacity of local communities for improving the quality of tourism services, and 4) to provide the infrastructure for tourism business such as road accessing, water supply and disaster prevention.