• 제목/요약/키워드: Water Hammer Pump

검색결과 27건 처리시간 0.025초

Effects of the Lift Valve Opening Area on Water Hammer Pump Performance and Flow Behavior in the Valve Chamber

  • Saito, Sumio;Dejima, Keita;Takahashi, Masaaki;Hijikata, Gaku;Iwamura, Takuya
    • International Journal of Fluid Machinery and Systems
    • /
    • 제5권3호
    • /
    • pp.109-116
    • /
    • 2012
  • Water hammer pumps can effectively use the water hammer phenomenon for water pumping. They are capable of providing an effective fluid transport method in regions without a well-developed social infrastructure. The results of experiments examining the effect of the geometric form of water hammer pumps by considering their major dimensions have been reported. However, these conventional studies have not fully evaluated pump performance in terms of pump head and flow rate, common measures of pump performance. The authors have focused on the effects on the pump performance of various geometric form factors in water hammer pumps. The previous study examined how the hydrodynamic characteristics was affected by the inner diameter ratio of the drive and lift pipes and the angle of the drive pipe, basic form factors of water hammer pumps. The previous papers also showed that the behavior of water hammer pump operation could be divided into four characteristic phases. The behavior of temporal changes in valve chamber and air chamber pressures according to the air volume in the air chamber located downstream of the lift valve was also clarified in connection with changes in water hammer pump performance. In addition, the effects on water hammer pump performance of the length of the spring attached to the drain valve and the drain pipe angle, form factors around the drain valve, were examined experimentally. This study focuses on the form of the lift valve, a major component of water hammer pumps, and examines the effects of the size of the lift valve opening area on water hammer pump performance. It also clarifies the behavior of flow in the valve chamber during water hammer pump operation.

Effects of the Air Volume in the Air Chamber on the Performance of Water Hammer Pump System

  • Saito, Sumio;Takahashi, Masaaki;Nagata, Yoshimi
    • International Journal of Fluid Machinery and Systems
    • /
    • 제4권2호
    • /
    • pp.255-261
    • /
    • 2011
  • Recently, as global-scale problems, such as global warming and energy depletion, have attracted attention, the importance of future environmental preservation has been emphasized worldwide, and various measures have been proposed and implemented. This study focuses on water hammer pumps that can effectively use the water hammer phenomenon and allow fluid transport without drive sources, such as electric motors. An understanding of operating conditions of water hammer pumps and an evaluation of their basic hydrodynamic characteristics are significant for determining whether they can be widely used as an energy-saving device in the future. However, conventional studies have not described the pump performance in terms of pump head and flow rate, common measures indicating the performance of pumps. As a first stage for the understanding of water hammer pump performance in comparison to the characteristics of typical turbo pumps, the previous study focused on understanding the basic hydrodynamic characteristics of water hammer pumps and experimentally examined how the hydrodynamic characteristics were affected by the inner diameters of the drive and lift pipes and the angle of the drive pipe. This paper suggests the effect of the air volume in the air chamber that affects the hydrodynamic characteristics and operating conditions of the water hammer pump.

Effects of the Geometry of Components Attached to the Drain Valve on the Performance of Water Hammer Pumps

  • Saito, Sumio;Takahashi, Masaaki;Nagata, Yoshimi;Dejima, Keita
    • International Journal of Fluid Machinery and Systems
    • /
    • 제4권4호
    • /
    • pp.367-374
    • /
    • 2011
  • Water hammer pumps can effectively use the water hammer phenomenon in long-distance pipeline networks that include pumps and allow fluid transport without drive sources, such as electric motors. The results of experiments that examined the effect of the geometric form of water hammer pumps by considering their major dimensions have been reported. In addition, a paper has also been published analyzing the water hammer phenomenon numerically by using the characteristic curve method for comparison with experimental results. However, these conventional studies have not fully evaluated the pump performance in terms of pump head and flow rate, common measures indicating the performance of pumps. Therefore, as a first stage for the understanding of water hammer pump performance in comparison with the characteristics of typical turbo pumps, the previous paper experimentally examined how the hydrodynamic characteristics were affected by the inner diameter ratio of the drive and lifting pipes, the form of the air chamber, and the angle of the drive pipe. To understand the behavior of the components attached to the valve chamber and the air chamber that affects the performance of water hammer pumps, the previous study also determined the relationship between the water hammer pump performance and temporal changes in valve chamber and air chamber pressures according to the air chamber capacity. For the geometry of components attached to the drain valve, which is another major component of water hammer pumps, this study experimentally examines how the water hammer pump performance is affected by the length of the spring and the angle of the drain pipe.

펌프 기동 및 정지에 따른 배관 압력상승과 수격작용 영향 고찰 (Consideration of Pressure-Rise and Water Hammer for Pipe System in Relation to Start-Up and Sudden Stop of the Pump)

  • 허민웅;민지호
    • 한국압력기기공학회 논문집
    • /
    • 제13권1호
    • /
    • pp.69-74
    • /
    • 2017
  • In the fire protection system or fire fighting water supply system, the jockey pump is generally installed for the prevention of the pressure decrease of pipes, the frequent driving of the fire pump and protection the pipes from the water hammer. In this paper, the pressure-rise in fire fighting water distribution pipes in condition of pipe pressurization by the surge tank at the start-up and the sudden-stop of the fire pump without additional installation of jockey pump is considered by using simple formula calculations and the evaluation of water hammer occurrence in condition of pipe pressurization by the surge tank is included. As a result, the pressure-rise of pipes is less than the pipe design pressure at the condition of pump's start-up and sudden stop, and the possibility of water hammer occurrence is remarkably low due to pressurization of the pipes by the surge tank.

펌프관로계의 수격현상 해석 (An analysis of water hammer in pipeline systems with pump)

  • 이명호
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제22권1호
    • /
    • pp.92-99
    • /
    • 1998
  • Unsteady flow problems created by hydraulic transients in pipeline systems with pump are of significant importance because they can cause excessive pressure, cavitation, vibration and noise. In this paper, an analysis of transient flow for the pump pipelines is developed by means of the characteristic method. The calculated results of the program to simulate water hammer due to sudden valve closure in a simple pipeline are compared with those of the analytical method. Expecially the water hammer due to power failure in pump pipeline system with surge tank was simulated. As the results, both the upsurge and the downsurge along the pipeline are reduced.

  • PDF

에어챔버 설치에 따른 펌프관로계의 수격현상 (Water-hammer in the Pump Pipeline System with and without an Air-Chamber)

  • 이선곤;양철수
    • 한국안전학회지
    • /
    • 제26권1호
    • /
    • pp.1-7
    • /
    • 2011
  • When the pumps stopped in the operation by the power failure, the hydraulic transients take place in the sudden change of a velocity of pipe line. Each and every water hammer problem shows the critical stage to be greatly affected the facts of safety and reliability in case of power failure. The field tests of the water hammer executed at Cheong-Yang booster pump station having an air chamber. The effects were studied by both the practical experiments and the CFD(Computational Fluid Dynamics : Surge 2008). The result states that the system with water hammering protection equipment was much safer when power failure happens. The following data by a computational fluid dynamic analysis are to be shown below, securing the system stability and integrity. (1) With water hammering protection equipment. (1) Change of pressure : Up to $15.5\;kg/cm^2$ in contrary to estimating $16.88\;kg/cm^2$. (2) Change rate of water level : 52~33% in contrary to estimating 55~27%. (3) Note that the operational pressure of pump runs approx. 145 m, lowering 155 m of the regularity head of pump. (4) Note that the cycle of water hammering delays from 80 second to 100 second, together with easing the function of air value at the pneumatic lines. (2) Change of pressure without water hammering protection equipment : Approximate $22.86\;kg/cm^2$. The comprehensive result says that the computational fluid dynamics analysis would match well with the practical field-test. It was able to predict Max. or Min. water hammering time in a piping system. This study aims effectively to alleviate water hammering in a pipe line to be installed with air chamber at the pumping station and results in making the stability of pump system in the end.

관로계통 및 가압펌프장 수격에 따른 최적 안정성 확보방안 (Application & Examination of the Plan for Optimum Stability through Water-hammer in Pipe Line and Booster Pump Station)

  • 라병필;박종호
    • 한국유체기계학회 논문집
    • /
    • 제12권5호
    • /
    • pp.19-24
    • /
    • 2009
  • This paper is performed to find out the stability of water-hammer in pipe line and pump station that is happened when additional water needs demanded. At first, the water supply construction project is planned to supply $6,000\;m^3/day$ through 17.9 km pipe line. But additional demand ($1,200\;m^3/day$) happened from Cheong-ra water reservoir. In this situation, air-chamber($4\;m^3$) and vacuum breaker valve(${\varphi}100\;mm$) are needed to prevent water-hammer. When the additional water is supplied, the existing facilities (air-chamber, vacuum breaker valve) are sufficient to alleviate shock not changing capacity alteration, judging from the airspace change and rise. Therefore, there is no problem for water-hammer by installing air-chamber($4\;m^3$) and vacuum breaker valve(${\varphi}100\;mm$) at the top of Yeo-ju hill.

에어챔버가 설치된 가압펌프 계통에서의 수격현상 (Water Hammer in the Pump Pipeline System with an Air Chamber)

  • 김상균;이계복
    • 에너지공학
    • /
    • 제16권4호
    • /
    • pp.187-193
    • /
    • 2007
  • 갑작스런 펌프 정지로 야기되는 수격현상은 과압이나 부압을 일으킬 수 있다. 과압을 줄이거나 부압을 방지하는 것은 계통설비의 피로를 피하고 작동효율을 향상시키기 위해 필요하다. 에어챔버가 설치된 펌프 관로 계에서 수격현상에 대한 현장시험을 수행하였다 또한 특성 곡선법을 사용하여 과도현상에 대한 수치해석을 수행하였다. 계통에 대한 헌장시험과 수치해석 결과를 비교하여 수치해석코드에 사용되는 주요 입력변수인 폴리트로픽 지수, 유량계수, 압력파의 속도에 대한 보정값 검증과 민감도 분석을 수행하였다. 수격현상을 최소화할 수 있는 에어챔버의 크기와 관련 변수의 영향이 현장시험과 수치해석을 통해 연구되었다.

수격현상에 대한 수치적 고찰 (A Computational Analysis of Water-Hammer)

  • 전광민
    • 대한설비공학회지:설비저널
    • /
    • 제11권1호
    • /
    • pp.1-10
    • /
    • 1982
  • The water-hammer phenomena caused by pump power failure are analysed by digital computer. Asan cool ins water pipe system has been chosen as a model. It is Shown that after power failure the pressure at the pump outlet drops sharply, and to prevent reverse flow, either butterfly valve or check valve can be used. After the valve closure, pressure oscillates behind the valve. To weaken the pressure wave, it is recommended to install a servo-operated valve in a bypass Line around the pamp and the check valve.

  • PDF

급수배관시스템의 수충격 진동제어를 위한 실험적 연구 (An Experimental Study on Vibration Control of Water Hammering in Water Pipe System)

  • 이장현;이효행;권병하;오진우
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 하계학술발표대회 논문집
    • /
    • pp.453-458
    • /
    • 2008
  • Pump of high lift use to development of a technological level according as a building grow big. Water-Hammer to increase by valve of fast to closing agreeably to pipe laying to accept electronic valve, because by a damage of piping-system and the devil knows injury of vibration. Water-Hammer take a low effect to various method for solve. A New type manufacture develop and testing of pipe line to same to axis use to accumulator for water-Hammer to low effect and liner control of pressure. Impact-pressure of absorption ability and confirmation to decrease of vibration level through to preexistence manufactures and comparative test. Water-hammer and pipe vibration make low of piping system.

  • PDF