• Title/Summary/Keyword: Water Concentration

Search Result 11,845, Processing Time 0.041 seconds

Effect of Low Concentration Liquid Manure application on Soil Water and Groundwater Quality in Bio-Circulation Experimental Forest (바이오순환림의 저농도액비 시용에 따른 토양수 및 지하수 수질 영향 분석)

  • Hong, Eun-Mi;Choi, Jin-Yong;Yoo, Seung-Hwan;Nam, Won-Ho;Yeo, Jin-Kie;Choi, In-Gyu
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.52 no.5
    • /
    • pp.37-45
    • /
    • 2010
  • Manure recycling as fertilizer is one of solutions for the environmental problem related with livestock manure treatment as well as the ocean dumping ban act prohibiting manure disposal to the ocean. For the manure disposal, forest area can be a candidate place because the area has a wide range of applicable sites. However, the manure application to the forest has a possibility of causing environmental impacts including water quality problems due to nutrient loading. Therefore it is necessary to investigate water quality impact from manure disposal to the forestry plantation. In this study, ground and soil water quality had been monitored in the bio-circulation experimental forest where low concentration liquid manure (LCLM) was applied. Soil and groundwater samples were collected and analyzed weekly from April to October in 2008 and 2009. The mean and variation of NO3-N concentration in soil water of LCLM treatment places showed higher concentration than the reference places declining during growing season. In the case of groundwater from monitoring well in the downstream of disposal site, the $NO_3$-N concentration was 3.59 mg/L in 2008 and 3.26 mg/L in 2009 in average showing higher concentration than the reference well although the concentration was not exceed the national drinking water standard. To investigate the source of nitrate, $\delta^{15}N$ isotope analysis was also implemented. Its result showed that the LCLM application could be the nitrate source requiring further long-term monitoring soil and water quality.

Coating formation of water supply pipes by inhibitor and water quality improvement effect (부식억제제에 의한 상수도관의 피막 형성 및 수질개선 효과)

  • Lim, Jae-Cheol;Kim, Jin-Keun;Koo, Ja-Yong
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.26 no.1
    • /
    • pp.97-106
    • /
    • 2012
  • To investigate the application of corrosion inhibitor on water supply pipes, turbidity, magnitude of corrosion, composition of scale and concentration of metals from an old steel pipe were analysed under inhibitor addition. The concentration of turbidity, iron and copper from the pipes under inhibitor application was 12 ~ 14% of the case which no inhibitor was applied, which suggests the application of inhibitor was very effective for internal corrosion control. In addition, SEM, EDX, XRD and XRF test results showed that application of inhibitor was effective for the decrease of iron concentration and increase of oxygen, phosphorus and calcium concentration, which suggested the existence of protective layer. Therefore, the occurrence of red water will be significantly decreased when inhibitor was applied to the old steel pipes.

Pathophysiology and management of disorders in water metabolism (수분 대사 장애 질환의 병태 생리와 치료)

  • Kim, Dong Un
    • Clinical and Experimental Pediatrics
    • /
    • v.50 no.5
    • /
    • pp.430-435
    • /
    • 2007
  • Even though we drink and excrete water without recognition, the amount and the composition of body fluid remain constant everyday. Maintenance of a normal osmolality is under the control of water balance which is regulated by vasopressin despite sodium concentration is the dominant determinant of plasma osmolality. The increased plasma osmolality (hypernatremia) can be normalized by the concentration of urine, which is the other way of gaining free water than drinking water, while the low plasma osmolality (hyponatremia) can be normalized by the dilution of urine which is the only regulated way of free water excretion. On the other hand, volume status depends on the control of sodium balance which is regulated mainly by renin-angiotensin-aldosterone system, through which volume depletion can be restored by enhancing sodium retention and concomitant water reabsorption. This review focuses on the urine concentration and dilution mechanism mediated by vasopressin and the associated disorders; diabetes insipidus and syndrome of inappropriate antidiuretic hormone secretion.

Microorganism Contamination from Diffuse Sources and Its Impacts on Water Quality in the Geum River Basin (금강유역 비점원에서 발생하는 미생물 오염 및 수질에 대한 영향)

  • Kim, Geonha
    • Journal of Korean Society on Water Environment
    • /
    • v.22 no.3
    • /
    • pp.504-512
    • /
    • 2006
  • In order to estimate microbial contaminant discharge from diffuse sources, rainfall runoff was monitored at forestry, agriculture and urban watersheds. Total coliform and E. coli were monitored at the study watersheds as they are regulated by the environmental laws. Concentration and EMC (Event Mean Concentration) of coliform of rainfall runoff at the urban watershed were the highest followed by those from agricultural and forestry watersheds. By monitoring coliform concentrations of overlying water and sediment at five monitoring points in the downstream of the Geum River, average concentration from spring to summer was higher than those values from fall to spring. Coliform concentrations in the pore water were higher compared to those of overlying water and closely related with flow rate of the river.

A Experimental Study on Waste Water Concentration by Separating Method of Freezing (동결분리방법을 이용한 폐수농축에 관한 실험적 연구)

  • Kim, Jung-Sik
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2006.06a
    • /
    • pp.51-52
    • /
    • 2006
  • This study was progressed on the freezing behavior of waste water in relation to freeze concentration method useful to waste water treatment system of small and middle size and which can re-use purified water. The object of this experiment is comparing a pollutant contain of the frozen layer and of an aqueous solution by cooling wall temperature, a flow field effect and a initial thickness of frozen layer.

  • PDF

Desalination of geothermal water by membrane distillation

  • Gryta, M.;Palczynski, M.
    • Membrane and Water Treatment
    • /
    • v.2 no.3
    • /
    • pp.147-158
    • /
    • 2011
  • Membrane distillation process was used for desalination of hot (333 K) geothermal water, which was applied in the plant producing heating water. The investigated water contained 120 g salts/$dm^3$, mainly NaCl. The mineral composition was studied using an ion chromatography method. The obtained rejection of solutes was closed to 100%, but the small amounts of $NH_3$ also diffused through the membrane together with water vapour. However, the composition of obtained distillate allowed to use it as a makeup water in the heating water system. The geothermal water under study was concentrated from 120 to 286 g NaCl/$dm^3$. This increase in the solution concentration caused the permeate flux decline by a 10-20%. The geothermal water contained sulphates, which was subjected to two-fold concentration to achieve the concentration 2.4-2.6 g $SO{_4}{^{2-}}/dm^3$ and the sulphates then crystallized in the form of calcium sulphate. As a results, an intensive membranes scaling and the permeate flux decline was observed. The XRD analysis indicated that beside the gypsum also the NaCl crystallites were deposited on the membrane surfaces. The fresh geothermal water dissolved the mixed $CaSO_4$ and NaCl deposit from the membrane surface. This property can be utilized for self-cleaning of MD modules. Using a batch feeding of MD installation, the concentration of geothermal water was carried out over 800 h, without significant performance losses.

Simulation for Chlorine Residuals and Effect of Rechlorination in Drinking Water Distribution Systems of Suwon City (수원시 상수관망에서 잔류염소와 재염소주입의 효과 예측)

  • Kim, Kyung-Rok;Lee, Byong-Hi;Yoo, Ho Sik
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.14 no.1
    • /
    • pp.108-116
    • /
    • 2000
  • Chlorine is widely used as a disinfectant in drinking-water systems throughout the world. Chlorine residual was used as an indicator for prediction of water quality in water distribution systems. The variation of chlorine residual in drinking water distribution systems of Suwon city was simulated using EPANET. EPANET is a computerized simulation model which predicts the dynamic hydraulic and water quality behavior within a water distribution system operating over an extended time period. Sampling and analysis were performed to calibrated the computer model in 1999 (Aug. Summer). Water quality variables used in simulations are temperature, roughness coefficient, pipe diameter, pipe length, water demand, velocity and so on. Extended water residence time affected water quality due to the extended reaction time in some areas. All area showed the higher concentration of chlorine residual than 0.2mg/l(standard). So it can be concluded that any area in Suwon city is not in biological regrowth problem. Rechlorination turned out to be an useful method for uniform concentration of free chlorine residual in distribution system. The cost of disinfectant could be saved remarkably by cutting down the initial chlorine concentration to the level which guarantees minimum concentration (0.2mg/l) throughout the distribution system.

  • PDF

A Survey of Water Quality and Improvement Measure of Imjin-River (임진강수계의 수질조사 및 개선방안)

  • 김형진;백영석;이준석
    • Journal of environmental and Sanitary engineering
    • /
    • v.10 no.1
    • /
    • pp.66-75
    • /
    • 1995
  • This survey is executed about the water quality and improvement measure of Imjin- river. The results are summarized as follows; 1 ) Ammonia nitrogen concentration in tap water was two times higher than drinking water standard. 2) The concentration of BOD in textile wastewater was 235ppm which is higher than wastewater distribution standard and leather wastewater showed high nitrogen concentration. 3) Water quality of the Imjin- river upstream was not in problem but that of Shin- stream showed somewhat high concentration in BOD, COD, and ammonia nitrogen. Especially the detected Cynide compound on the lower of Shin- stream implied seriously polluted condition. 4) The heavy metal in soil of the river bed was not detected but iron, zinc was detected to high concentration. 5) It Is urgently suggested to build more municipal sewage and sanitary treatment plants, and run dredging and river bed rearrangement project. 6) The Construction of the wastewater treatment complexes of relevant industries shall be propelled as soon as possible.

  • PDF

Prediction of Chlorine Concentration in a Pilot-Scaled Plant Distribution System (Pilot 규모의 모의 관망에서의 염소 농도 예측)

  • Kim, Hyun Jun;Kim, Sang Hyun
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.26 no.6
    • /
    • pp.861-869
    • /
    • 2012
  • The chlorine's residual concentration prevents the regrowth of microorganism in water transport along the pipeline system. Precise prediction of chlorine concentration is important in determining disinfectant injection for the water distribution system. In this study, a pilot scale water distribution system was designed and fabricated to measure the temporal variation of chlorine concentration for three flow conditions (V = 0.88, 1.33, 1.95 m/s). Various kinetic models were applied to identify the relationship between hydraulic condition and chlorine decay. Genetic Algorithm (GA) was integrated into five kinetic models and time series of chlorine were used to calibrate parameters. Model fitness was compared by Root Mean Square Error (RMSE) between measurement and prediction. Limited first order model and Parallel first order showed good fitness for prediction of chlorine concentration.

The Effect of Turbidity and Alkalinity on the Regidual Aluminum Concentration (탁도(濁度) 및 알카리도(度)가 잔류(殘留)알루미늄 농도(濃度)에 미치는 영향(影響))

  • Choi, Suingil;Lee, Changsook
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.9 no.3
    • /
    • pp.88-98
    • /
    • 1995
  • Several kinds of coagulants such as aluminum sulfate, PAC, PASS are being used to treat drinking water resulting in residual aluminum ions in the water. Recently, it has been reported that high intake of aluminum ion may cause neurological dieseases such as Alzheimer's diesease and presenile dementia. Because of the possible adverse effect, WHO and EEC recommand to regulate residual aluminum. The autorities in Korea also has plan of regulating residual alunimum from 1995. But there is not enough information about the range of residual aluminum ion concentration when the aluminum sulfate, PAC or PASS has been used as a coagulant. Therefore the study has been conducted to find out the range of residual aluminum ion concentration after using aluminum sulfate, PAC, and PASS. Furthermore the effect of turbidity and alkalinity have been investigated. The experimental results are summarized as; 1. Most of the residual aluminum ion concentrations were within $10^{-6}$ and $10^{-5}mole/l$. Three coagulants have not showed any considerable difference in the residual aluminum concentration up to 50 NTU. However PAC has showed the least residual aluminum in high turbidity water over 100 NTU. 2. The low alkalinity water having 25mg/l as $CaCO_3$ has showed less residual aluminum than the water having 50mg/l alkalinity. However, the difference was not significcant. 3. Even the lowest residual aluminum concentration was over 0.05mg/l. Therefore the process to reduce residual aluminum would be necessary in water treatment plants.

  • PDF