• 제목/요약/키워드: Water Column

검색결과 2,046건 처리시간 0.041초

증류탑 제어에 있어서 로바스트 다변수 제어 응용에 관한 연구 (On the Application af Robust Multivariable Controller to Distillation Column)

  • 고재욱;이원규
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1986년도 한국자동제어학술회의논문집; 한국과학기술대학, 충남; 17-18 Oct. 1986
    • /
    • pp.238-243
    • /
    • 1986
  • Distillation columns are widely used in almost every chemical plant. The use of multivariable control for such units is attractive because of the strong interactions exhibited between outputs and inputs and the desire to control simultaneously both top and bottom products. In this research design of a robust multivariable controller for distillation column was considered; output feedback controller with proportional and integral modes was designed using pole assignment. The transfer function matrix was obtained by fitting the step response realtions between single input double output pairs of variables. This matrix was then converted to linear time invariant state space model by multivariable realization technique. With the proposed multivariable proportional and integral controller applied to the process, the result of the digital computer simulation showed a good performance of asymtotic tracking. The limited experimental performance of this multivariable control was compared with the result from simulation. It was found that the proposed controller performed satisfactorily for the distillation column which separated binary mixture of methanol and water.

  • PDF

1차원 현장 soil column 실험을 통한 SAT 반응 모델 검증

  • 김정우;;차우석;최희철
    • 한국지하수토양환경학회:학술대회논문집
    • /
    • 한국지하수토양환경학회 2003년도 추계학술발표회
    • /
    • pp.83-86
    • /
    • 2003
  • Soil Aquifer Treatment (SAT) is a technique in which secondary- or tertiary-treated wastewater is infiltrated through unsaturated soil and stored in the saturated zone. In SAT, contaminants are removed by physical and biochemical reactions taking place in soils. In this study, a numerical model was developed to predict changes in water quality during SAT operations. The contaminant species considered in the model were ammonium, nitrate, dissolved organic carbon, and dissolved oxygen. The model was calibrated against experimental data obtained from one dimensional soil column tests conducted for 84 days. The calibrated model will be used to find out optimum conditions for the pilot- and regional-scale SAT operations to be scheduled for the next phase of this project.

  • PDF

증류탑의 실시간 최적화 (On-line optimization of a distillation column)

  • 최용진;노균;윤인섭
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1990년도 한국자동제어학술회의논문집(국내학술편); KOEX, Seoul; 26-27 Oct. 1990
    • /
    • pp.229-233
    • /
    • 1990
  • A new on-line optimization technique of a distillation column is presented. The equation decoupling method and the simultaneous solution method are combined to simulate the distillation process. The storage requirement is small enough to run on a PC. A improved successive quadratic programming is used to find the optimum operating conditions. The optimizer is intensively tested by using the dynamic simulator, SPEEDUP. After this, the technique is applied to a binary distillation column that treats methanol and water.

  • PDF

파력발전용 가변수주진동장치의 운동해석 (Motion analysis of a VLCO for wave power generation)

  • 이승철;구자삼
    • 동력기계공학회지
    • /
    • 제18권3호
    • /
    • pp.36-41
    • /
    • 2014
  • The structure of a variable liquid column oscillator(a VLCO) is analogous to that of the tuned liquid column damper used to suppress oscillatory motion in large structures like tall buildings and cargo ships. The VLCO is a system absorbing high kinetic energy of accelerated motions of the multiple floating bodies in the effect of air springs occurred by installation of inner air chambers. Thus, VLCO can improve the efficiency of energy than wave energy converters of the activating object type made in Pelamis Company. In this research, the experiment was performed in two models of same draft. The one is that weights were filled, and the other is that water was filled. The numerical results were estimated by assuming that do not exist internal flow, and the results were compared with the results of experiments.

기.고 크로마토그래피법에 의한 이산화질소 측정 (Determination of Nitrogen Dioxide by Gas-Solid Chromatography)

  • 임굉
    • 공학논문집
    • /
    • 제2권1호
    • /
    • pp.147-149
    • /
    • 1997
  • 이산화질소는 Linde Molecular Sieve 칼럼에 흡수된 물에 의해 일산화질소로 급속히 전환된다. 합성된 파형은 칼럼에 도입된 순수 일산화질소의 것과 구별할 수 없는 것이다. 따라서 저비점 일산화질소로 전환함으로써 유기분배액의 산화의 복잡성은 미연에 방지된다.

  • PDF

분리벽형 증류탑을 적용한 필름공정의 폐용매 회수공정 최적설계 (Optimal Design of Solvent Recovery Process with Dividing Wall Column for Film Making Process)

  • 이승현;조문신;이문용
    • 제어로봇시스템학회논문지
    • /
    • 제12권12호
    • /
    • pp.1209-1214
    • /
    • 2006
  • This paper presents an application of Dividing Wall Column(DWC) to the recovery of the waste solvent from the film making processes. The waste solvent feed contains MEK(Methyl-Ethyl-Ketone), Toluene, Cyclohexanone, and water. The commercial software $HYSYS^{TM}$ was used for rigorous simulation and analysis. Sensitivity analysis for several major design variables were carried out to achieve the optimal design of the process. Distribution of the internal vapor and liquid flows to the prefractionator and main sections is shown to be the most dominant design factor for energy saving efficiency in the DWC process. The simulation results also show that the solvent recovery process using the DWC significantly improves both the energy efficiency and the compactness of the solvent recovery process.

The Vibration Performance Experiment of Tuned Liquid Damper and Tuned Liquid Column Damper

  • Kim Young-Moon;You Ki-Pyo;Cho Ji-Eun;Hong Dong-Pyo
    • Journal of Mechanical Science and Technology
    • /
    • 제20권6호
    • /
    • pp.795-805
    • /
    • 2006
  • Tuned Liquid damper and Tuned Liquid Column are kind of passive mechanical damper which relies on the sloshing of liquid in a rigid tank for suppressing structural vibrations. TLD and TLCD are attributable to several potential advantages - low costs ; easy to install in existing structures : effective even for small-amplitude vibrations. In this paper, the shaking table experiments were conducted to investigate the characteristics of water sloshing motion in TLD (rectangular, circular) and TLCD. The parameter obtained from the experiments were wave height, base shear force and energy dissipation. The shaking table experiments show that the liquid sloshing relies on amplitude of shaking table and frequency of tank. The TLCD was more effective control vibration than TLD.

다목적 여과저류지를 이용한 하천수의 조류와 인 제거방안 제안 (A Proposition for the Removal of Algae and Phosphorus from River Water Using Multi-Purpose filtration pond)

  • 최홍규;정일화;배가람;박재영;이종진;김용운;정관수;김승현
    • 대한환경공학회지
    • /
    • 제35권7호
    • /
    • pp.525-531
    • /
    • 2013
  • 대하천의 조류문제에 대한 해결책을 찾기 위해 다목적 여과저류지를 활용하는 방안을 연구하였다. 문헌조사를 통해 용존 인의 흡착제거에 우리나라에서는 굴패각이 적합함을 알 수 있었고, 이를 흡착제로 활용한 등온흡착실험과 칼럼실험을 수행하였다. 등온흡착실험결과 흡착에 의해 하천수의 용존 인을 모두 제거하여 대하천에서의 조류발생을 방지하는 것은 어렵다는 것을 알 수 있었고, 칼럼실험결과 제한적인 조건에서는 굴패각을 흡착여재로 활용하는 방안이 가능함을 알 수 있었다. 실험결과를 근거로 이미 발생한 조류를 여과저류지를 이용하여 제거하는 방안을 제시하였으며, 인공하천의 하상표층에 형성된 슬러지 케익을 기계적으로 제거하여 하류의 농축부에 모아 최종제거하고 또한 농축부에서 흡착재로 굴패각을 사용함으로써 농축부의 사멸조류에 의한 인의 재방출을 억제하는 것이다.

해수중 콘크리트 기둥의 열화 및 보강성능해석 (Deterioration of Concrete Columns under Sea-Water and Strengthening Analysis)

  • 김규엽;송하원;변근주
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2001년도 가을 학술발표회 논문집
    • /
    • pp.1169-1174
    • /
    • 2001
  • In this study, the behavior of deteriorated concrete columns under sea-water before and after strengthening with glass fiber composite and the change of behavior by the deterioration of strengthening material are analyzed. In the analysis, the characteristics of concrete deteriorated in sea-water, preloading effect, and corrosion of steel are considered. The result of analysis is verified by the comparison with the experimental data. Using constitutive equations of the concrete and corroded steel, load-moment interaction curves of both deteriorated and strengthened concrete column are derived.

  • PDF

Cacao Bean Husk 추출물의 Glucosyltransferase 저해효과 (Inhibitory Effect of Cacao Bean Husk Extract on Glucosyltransferase from Streptococus mutans B13)

  • 권익부;이용우안봉전이신영
    • KSBB Journal
    • /
    • 제8권1호
    • /
    • pp.75-82
    • /
    • 1993
  • The inhibitory effect of cacao bean husk (CBH) extract on glucosyltransferase(GTasc) from Streptococcus mutans B13 was investigated. Water solube extract from CBH showeda sarong inhibitory effect (88-89%) on GTase from Streptococcus mutans Bl3. GTase inhibitors from sequential extraction by hot water or water-methanol had the strongest inhibition. Sources, fermentation, and types of solvents and fumigation processes did not influence the effect. These active compounds proved to be polyphones through acid hydrolytic analysis of the precipitates by ammonium sulfate or ethanol and proteinase K. It was also confirmed by additional column chromatography of Sephadex G-50, Sephadex LH-20 and DEAE-Sephdex A-50.

  • PDF