• Title/Summary/Keyword: Water Column

Search Result 2,046, Processing Time 0.032 seconds

Anaerobic Treatment of Nitrate in Landfill Leachate (쓰레기 매립장 침출수 중 질소저감방안)

  • Kwon, Young Ho;Kim, Ho Ju
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.12 no.4
    • /
    • pp.70-77
    • /
    • 1998
  • On this study, removal ability of nitrate was researched in the anaerobic zone arounding collection pipes in landfill. Stability state time of column was after 20 days and 20~90ml/day in flux. In this time, removal rate of phosphate was about 80%. Removal ability and average removal rate of CODCr is $36g/m^3{\cdot}d$, 25.3%, respectively. It was that reactor is able to remove more nitrate. Maximum nitrate removal ability was $4.83g/m^3{\cdot}d$.

  • PDF

Hydrophobic Catalyst Mixture for the Isotopic Exchange Reaction between Hydrogen and Water

  • Paek S.;Ahn D.H.;Choi H.J.;Kim K.R.;LEE M.;YIM S.P.;CHUNG H.
    • Proceedings of the Korean Radioactive Waste Society Conference
    • /
    • 2005.11b
    • /
    • pp.141-148
    • /
    • 2005
  • Pt/SDBC catalyst, which is used for the hydrogen-water isotopic exchange reaction, was prepared. The various properties of the catalyst, such as the thermal stability, pore structure and the platinum dispersion, were investigated. A hydrophobic Pt/SDBC catalyst which has been developed for the LPCE column of the WTRF (Wolsong Tritium Removal Facility) was tested in a trickle bed reactor. An experimental apparatus was built for the test of the catalyst at various temperatures and gas velocities.

  • PDF

Dynamics of Organic Matter and Inorganic Nutrients in a Over-enriched Mountain Stream due to Anthropogenic Loading (생활하수가 유입된 산지하천(대천천)의 유기물 및 무기영양염의 동태)

  • Park, Jung-Im;Kim, Young-Kyun;Chung, Mi-Hee;Song, Mi-Young;Lee, Sang-Ho;Chon, Tae-Soo;Lee, Kun-Seop
    • Korean Journal of Environmental Biology
    • /
    • v.24 no.3
    • /
    • pp.230-239
    • /
    • 2006
  • Nutrient over-enrichment as a consequence of anthropogenic loading leads to eutrophication, which has the detrimental effects on river and stream ecosystems. To examine dynamics of factors causing cultural eutrophication in a over-licked mountain stream due to anthropogenic loading, physicochemical parameters were measured from 5 stations in the upper Daecheon stream, Busan, from January 2002 to May 2003. The five study sites were located along the stream gradient. DC1 is upper most clean site, and DC5 is located at the lowest area. Wastewater was released into the stream from just upstream of DC2 site. Water column ammonium and phosphate concentrations were higher during winter than other seasons, while water column nitrate +nitrite concentration did not show clear seasonal variation. Water column ammonium, nitrate+nitrite and phosphate concentrations were lowest at DC1 and highest at DC2 in which waste water loading occurred. TOC and DOC, conductivity, turbidity, and BOD in the water column were also increased drastically at DC2, and then decreased at DC5. Sediment pore water phosphate concentrations during winter and spring were higher than those in summer and fall, while sediment pore water ammonium and nitrate +nitrite concentrations showed no seasonal trend. Sediment pore water ammonium and phosphate concentration were also increased at DC2 and slightly decreased at DC5, while sediment pore water nitrate+nitrite concentration was highest at DC5. Organic matter and inorganic nutrients at up-stream of Daechon stream significantly increased as a result of wastewater discharge, and the nutrient concentrations decreased at low-stream suggesting self-purification ability of the stream.

Wind-and Rain-induced Variations of Water Column Structures and Dispersal Pattern of Suspended Particulate Matter (SPM) in Marian Cove, the South Shetland Islands, West Antarctica during the Austral Summer 2000 (서남극 남 쉐틀랜드 군도 마리안 소만에서 바람 및 강수에 의한 여름철 수층 구조의 변화와 부유물질 분산)

  • 유규철;윤호일;오재경;강천윤;김예동;배성호
    • The Sea:JOURNAL OF THE KOREAN SOCIETY OF OCEANOGRAPHY
    • /
    • v.8 no.4
    • /
    • pp.357-368
    • /
    • 2003
  • Time-series CTDT (Conductivity/Temperature/Depth/Transmissivity) were obtained at one point near tidewater glacier of Marian Cove (King George Islands, Antarctica) to present water column properties and SPM (suspended particulate matter) dispersal pattern in relation with tide, current, meteorological data, and SPM concentration. Four layers were divided from the water column characteristics measured in the interval of an hour for about 2 days: 1) cold, fresh, and turbid surface mixed layer between 0-20 m in water depth, 2) warm, saline, and relatively clean Maxwell Bay inflow between 20-40 m in water depth, 3) turbid/cold tongue of subglacial discharges compared with the ambient waters between 40-70 m in water depth, and 4) cold, saline, and clean bottom water beneath 70 m in water depth. Surface plume, turbid freshwater at coastal/cliff area in late summer (early February), had the characteristic temperature and SPM concentration according to morphology, glacial condition, and composition of sediments. The restrict dispersion only over the input source of meltwater discharges was due to calm wether condition. Due to strong wind-induced surface turbulence, fresh and turbid surface plume, englacial upwelling cold water, glacier-contact meltwater, and Maxwell Bay inflow was mixing at ice-proximal zone and the consequent mixed layer deepened at the surface. Large amount of precipitation, the major controlling factor for increasing short-term glacial discharges, was accompanied by the apparent development of subglacial discharge that resulted in the rapid drop of salinity below the mid depth. Although amount of subglacial discharge and englacial upwelling may be large, however, their low SPM concentration would have small influence on bottom deposition of terrigenous sediments.

On Vortex Reduction Characteristics of Pump Sump Circulating Water Intake Basin of Power Plant Using Hydraulic Experiment (수리실험을 이용한 발전소의 순환수 취수부 흡입수조의 와류저감에 관한 연구)

  • Eom, Junghyun;Lee, Du Han;Kim, Hung Soo
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.42 no.6
    • /
    • pp.815-824
    • /
    • 2022
  • Among the main facilities of the power plant, the circulating water used for cooling the power generation system is supplied through the Circulation Water Intake Basin (CWIB). The vortexes of various types generated in the Pump Sump (PS) of CWIB adversely affect the Circulation Water Pump (CWP) and pipelines. In particular, the free surface vortex accompanied by air intake brings about vibration, noise, cavitation etc. and these are the causes of degradation of CWP performance, damage to pipelines. Then power generation is interrupted by the causes. Therefore, it is necessary to investigate the hydraulic characteristics of CWIB through the hydraulic model experiment and apply an appropriate Anti Vortex Device (AVD) that can control the vortex to enable smooth operation of the power plant. In general, free surface vortex is controlled by Curtain Wall (CW) and the submerged vortex is by the anti vortex device of the curtain wall. The detailed specifications are described in the American National Standard for Pump Intake Design. In this study, the circulating water intake part of the Tripoli West 4×350 MW power plant in Libya was targeted, the actual operating conditions were applied, and the vortex reduction effect of the anti vortex device generated in the suction tank among the circulating water intake part was analyzed through a hydraulic model experiment. In addition, a floor splitter was basically applied to control the submerged vortex, and a new type of column curtain wall was additionally applied to control the vortex generated on the free surface to confirm the effect. As a result of analyzing the hydraulic characteristics by additionally applying the newly developed Column Curtain Wall (CCW) to the existing curtain wall, we have found that the vortex was controlled by forming a uniform flow. In addition, the vortex angle generated in the circulating water pump pipeline was 5° or less, which is the design standard of ANSI/HI 9.8, confirming the stability of the flow.

A study on the algal growth-related water quality of the Dongbok laka

  • Kim, Jong-Min;Kim, Hyun-Ku;Huh, Yu-Jeong;Jeong, Jong-Bum
    • Proceedings of the Korea Society of Environmental Biology Conference
    • /
    • 2004.05a
    • /
    • pp.25-25
    • /
    • 2004
  • We studied algal growth-related water quality of the Dongbok lake which is the drinking water reservoir for the Gwangju municipality. Peridinium cinctum and several diatomic algal species frequently caused water bloom throughout the lake from early spring to late autumn. With the heaviest predominance of Peridinium cintum in May 2003, COD was 13.7 mg/I in the surface layer. Highly turbid surface water with 46.8 mg/I of SS was also caused by Perdinium bloom. Peridinium bloom decisively eliminated cyanobacterial growth in the lake, otherwise cyanobacterial bloom resulted. Dense algal layer was confined in the upper several meters of the water column above the thermocline, which gives relatively algae-free water in deeper layer suitable for drinking source water supply. Upon collapse of thermocline, water quality of the surface layer was improved while deeper layer was deteriorated in terms of water quality. This paper deals with some details of water quality changes with algal growth in the Dongbok lake past two years.

  • PDF

Analytical Methods for the Isolation of Dehydrotomatine and ${\alpha}$-Tomatine in Tomato Fruits by Use of Alumina Column Chromatography and High-Performance Liquid Chromatography (Alumina Column Chromatography와 HPLC에 의한 토마토의 Dehydrotomatine 및 ${\alpha}$-Tomatine 단리방법 연구)

  • Choi, Suk-Hyun;Kim, Hyen-Ryung;Lee, Jin-Shik
    • The Korean Journal of Food And Nutrition
    • /
    • v.23 no.4
    • /
    • pp.556-561
    • /
    • 2010
  • Tomato fruits(Lycoperisicon esculentum) synthesize the glycoalkaloids dehydrotomatine and ${\alpha}$-tomatine, possibly as defense against bacteria, fungi and insects. We developed a new effective method to prepare and purify dehydrotomatine and ${\alpha}$-tomatine that exists in tomato fruits using alumina column chromatography and high performance liquid chromatography (HPLC). The tomato glycoalkaloids(TGA) in tomato was extracted with 2% acetic acid, and then precipitated with ammonium hydroxide(pH=10.5). The dry precipitate substance was applied on alumina column, and then fractionated with water saturated n-butylalcohol. The TGA(Fr. No. 26~36) were collected and dried under reduced pressure. The TGA was performed on a reverse phase HPLC(Inertsil ODS-2, $5\;{\mu}m$), eluted with acetonitrile/20mM $KH_2PO_4$(24:76, v/v) at 208 nm. Two peaks were detected on HPLC, and individual peak was collected by repeating HPLC. Furthermore, to confirm the identity dehydrotomatine and ${\alpha}$-tomatine, each peak isolated was hydrolyzed with 1N HCl into sugar and aglycone tomatidine. The sugars were converted to trimethylsilyl ester derivatives. The nature and molar ratios of sugars were identified by gas-liquid chromatography(GLC) and the aglycone by high-performance liquid chromatography(HPLC). The first peak (Rt=17.5 min) eluted from HPLC was identified as dehydrotomatine, and second peak(Rt=21.0 min) was as ${\alpha}$-tomatine. This technique has been used effectively to prepare and isolate dehydrotomatine and ${\alpha}$-tomatine from tomato fruits.

Undrained Characteristics of Geogrid-Encased Stone Column under Cyclic Load Using Reduced-Scale Model Tests (축소모형실험에 의한 반복하중 작용시 지오그리드 감쌈 쇄석말뚝의 비배수 거동 특성)

  • Choi, Jin-Wook;Lee, Dae-Young;Yoo, Chung-Sik
    • Journal of the Korean Geotechnical Society
    • /
    • v.29 no.1
    • /
    • pp.109-120
    • /
    • 2013
  • This paper presents the results of a laboratory investigation into a study on undrained characteristics of a geogrid-encased stone column (GESC) installed in soft clay under cyclic load. In order to analyze behavior of settlement, pore water pressure, stress concentration ratio and strain of the GESC compared to a stone column, a series of reduced-scale laboratory tests were performed. The model tests show that GESC provides a simple and effective method of deformation resistance and settlement restraint when a short-term cyclic load is applied. The maximum strain of geogrid occurred at 1.2D and 1.5D from the top of the column. This paper highlights the importance of considering overlay effect and replacement ratio on cyclic load supporting GESC.

Development of Schiff Base Column and Glow Discharge Detector for HPLC : Preliminary Study I (HPLC용 Schiff Base 컬럼과 Glow Discharge 검출기의 개발에 관한 기초연구 I)

  • Kang, Mi-Ra;Kim, Eun-Soo;Shin, Jung-Sook;Park, Hyun-Kook;Yang, Jung-Sung;Lee, Sang C.
    • Analytical Science and Technology
    • /
    • v.8 no.3
    • /
    • pp.265-272
    • /
    • 1995
  • Schiff base ligand columns and glow discharge detector have been developed for the trace analysis of metal ions desolved in water. Various types of hydrazide Schiff base ligands have been used and, additionally, they were examined as a filling material of a HPLC column. The hydrazide Schiff base ligands used were N, N'-oxalybis(salicylaldehydrazone) (OBSH), N, N'-malonylbis(salicylaldehydrazone) (MBSH), and N, N'-succinylbis(salicylaldehydrazone) (SBSH). A mixture of Schiff base ligand and poly(styrene divinylbenzene) was examined and it showed a smooth flow of solution. The OBSH-polymer column demonstrated different effluent factors for different metal ions. Metal ions in eluates were detected by Hollow Cathode Glow Discharge-Atomic Emission Spectrometry(HCGD-AES). HCGD-AES showed good sensitivity and selectivity. This is only the preliminary results of new OBSH-polymer column and glow discharge detector.

  • PDF

A Study on High Strength Concrete of Concrete Filled Steel Tube Column (CFT 기둥용 초고강도 충전콘크리트에 관한 연구)

  • Jung, Keun-Ho;Lim, Nam-Gi;Lee, Young-Do
    • Journal of the Korea Institute of Building Construction
    • /
    • v.4 no.1
    • /
    • pp.127-132
    • /
    • 2004
  • CFT(Concrete Filled Steel Tube) is a structure of circular or squared of steel column filled with concrete. The steel tube holds the concrete inside and that makes this structure to perform superior features on stiffness, proof stress, transformation, fire resistance and construction itself. In this study, by over the 800kgf/$\textrm{cm}^2$ of high strength concrete for CFT column, research has been done on the basic property of matter such as fluidity, resistance on segregation, compressive strength, setting icons of the concrete filled in the steel tube under conditions of standard weather. Physical properties of concrete for CFT that Concrete with silica fume, fly ash of air entraining and high-range water reducing agent, that used to CFT column research purpose to find the most ideal composition, which is achieved by the investigation in the concrete's property of matter like ability of Slump, Slump Flow, Air content, Bleeding, and Settlement. For this study, experiments which are bused on obtained the result through physical test are practiced, with all of the experiment, specimens only for control are produced in each method of curing and analyzed to relations with core strength in mock-up test. In mock-up test, the research is studied compactability of concrete filled in tube and degree of hydration hysteresis, as a basic reference for applying to field of CFT column which is used over 800kgf/$\textrm{cm}^2$ high strength concrete.