• 제목/요약/키워드: Water Absorption Diagnosis

검색결과 11건 처리시간 0.032초

발전기 고정자 권선의 정전용량 측정을 통한 흡습 진단 방법에 관한 연구 (A Study on the Water Absorption Diagnosis Method through Capacitance Measurement for Generator Stator Windings)

  • 김희수;배용채;기창두
    • 한국정밀공학회지
    • /
    • 제23권11호
    • /
    • pp.50-57
    • /
    • 2006
  • The water leak in water-cooled generator stator windings can generate the serious accidents such as insulation breakdown and it brings a generator to the unexpected sudden outage. Accordingly, it is important to diagnose the water absorption of them for the effective operation of power plant. Especially, the capacitance value which is measured for diagnosis is very small so the special diagnosis methods like stochastic theory are needed. KEPRI developed the water absorption test equipment and diagnosis technology for them. The developed diagnosis technology is applied to the real system and the results of water absorption test for stator windings are agreed to them of water leak test.

발전기 고정자 권선의 흡습 진단 (A Study on the Diagnosis for Water Absorption of Generator Stator Windings)

  • 배용채;김희수;이두영
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2006년도 춘계학술대회 논문집
    • /
    • pp.297-298
    • /
    • 2006
  • Water leak for the water-cooled generator stator windings affects seriously the availability and the reliability of power plants. Generally, water absorption test is conducted in the power plant during outage in order to confirm if leak part is in the bars or not. In this paper, it is described that the capacitance of winding bars is measured by using the developed water absorption instrument system and the water absorption of winding bars is evaluated by using the stochastic methods. The good results by proposed diagnosis technique can be got. It is expected that the reliability of diagnosis for water absorption is increased if the proposed methods are applied to evaluate the water absorption of stator winding bars.

  • PDF

여러 가지 확률분포를 이용한 발전기 고정자 권선의 흡습 시험에 관한 연구 (A Study on the Water Absorption Test of Generator Stator Windings Using Probability Distributions)

  • 김희수;배용채;김희정;나명환
    • 응용통계연구
    • /
    • 제22권5호
    • /
    • pp.961-969
    • /
    • 2009
  • 발전기 고정자 권선의 냉각수 누수는 발전기 운전 중 절연 파괴를 발생시켜 발전소 불시정지를 발생시킬 뿐만 아니라 권선 손상에 따른 정비 기간 및 비용이 매우 많이 소요된다. 따라서 발전기 고정자 권선의 냉각수 누수가 발생하였을 때 재앙이 일어나기 전에 고정자 권선 절연물의 흡습 상태를 진단하는 것은 예방 정비 측면에서 매우 효과적인 정비 방안이라고 할 수 있겠다. 본 논문에서는 발전기 고정자 권선에 흡습여부를 알아보기 위하여 여러 가지 확률분포를 이용하여 판정기준값을 유도하였다. 또한, 유도된 판정기준값을 바탕으로 실제 관측된 자료를 이용하여 흡습여부를 판단하였다.

흡수식 냉동시스템의 고장현상 분석과 진단 (Fault Symptom Analysis and Diagnosis for a Single-Effect Absorption Chiller)

  • 한동원;장영수;김용찬
    • 설비공학논문집
    • /
    • 제27권11호
    • /
    • pp.587-595
    • /
    • 2015
  • In this study, fault symptoms were simulated and analyzed for a single-effect absorption chiller. The fault patterns of fault detection parameters were tabulated using the fault symptom simulation results. Fault detection and diagnosis by a process history-based method were performed for the in-situ experiment of a single-effect absorption chiller. Simulated fault modes for the in-situ experimental study are the decreases in cooling water and chilled water mass flow rates. Five no-fault reference models for fault detection of a single-effect absorption chiller were developed using fault-free steady-state data. A sensitivity analysis of fault detection using the normalized distance method was carried out with respect to fault progress. When mass flow rates of the cooling and chilled water decrease by more than 19.3% and 17.8%, respectively, the fault can be detected using the normalized distance method, and COP reductions are 6.8% and 4.7%, respectively, compared with normal operation performance. The pattern recognition method for fault diagnosis of a single-effect absorption chiller was found to indicate each failure mode accurately.

Study on Reliability of Water Absorption Diagnosis through Precise Water Absorption Test

  • Kim, Hee-Soo;Bae, Yong-Chae;Kim, Hee-Dong
    • Journal of Electrical Engineering and Technology
    • /
    • 제7권5호
    • /
    • pp.772-777
    • /
    • 2012
  • Accidents caused by water absorption in water-cooled generator stator windings often occur all over the world. The absorption into the insulator of the coolant, which is used to cool down the heat generated by stator windings during operation, leads to the deterioration of dielectric strength, and insulation breakdown. An insulation breakdown may cause not only an enormous economic loss but also a very serious grid accident that would compromise stable supply of electric power. More than 50 % of domestic generators have been in operation for more than 15 years, and water absorption tests performed on 50 water-cooled generator stator windings during a five-year planned preventive maintenance period beginning in 2006 identified water absorption problems in 10 of them, all of which required repair. Because the existing water absorption test detects this problem by utilizing stochastic methods after measuring the capacitances at the final positions of insulation breakdown, its accuracy is limited. This study demonstrates that water absorption can be more accurately diagnosed by utilizing method along with a more precise one.

수냉각 발전기 고정자 권선의 건조 과정 분석을 통한 누설 및 흡습 예측 진단에 관한 실험적 연구 (Experimental Study on Prediction and Diagnosis of Leakage and Water Absorption in Water-Cooled Generator Stator Windings by Drying Process Analysis)

  • 김희수;배용채;이욱륜;이두영
    • 대한기계학회논문집B
    • /
    • 제34권9호
    • /
    • pp.867-873
    • /
    • 2010
  • 수냉각 발전기 고정자 권선에서의 냉각수 누수 및 흡습에 의한 절연파괴 손상사례가 국내 및 국외에서 자주 발생되고 있다. 이러한 사고는 막대한 경제적 피해뿐만 아니라 전력의 안정적 공급 측면에서 매우 심각한 계통 사고로 연결될 수 있다. 특히 국내 발전기는 15년 이상 운전되어 열화가 진행된 발전기가 50% 이상이며, 계획예방정비 기간 중에 권선에서의 누설 및 흡습 권선이 종종 발견되고 있다. 기존에는 누수 시험 전 과정인 권선 건조 과정을 무시한 채 누수 시험 결과만으로 권선 누설 여부를 진단하였으나 본 논문에서는 누수 시험을 위한 준비 단계인 진공 건조 시의 권선 내부의 진공도 패턴 분석을 통해 권선 누설 및 흡습 여부를 예측진단할 수 있는 방법을 실험적으로 증명하였다.

딜의 수경재배에 적합한 배양액 개발 (Development of Optimum Nutrient Solution for Dill (Anethum graveolens L.) in Hydroponics)

  • 여경환;이용범
    • 생물환경조절학회지
    • /
    • 제6권4호
    • /
    • pp.299-309
    • /
    • 1997
  • 본 실험은 수경재배에서 딜의 양수분 흡수 패턴을 밝히고 생육과 환경특성에 적합한 배양액을 개발하여 실제 재배에 응용하고자 수행하였다. 이를 위해 딜의 양분 홉수율에 의한 배양액을 조성하였으며 그 적합성을 검정하기 위해 기존배양액과 비교실험을 실시하였다. 딜의 NFT재배에 적합한 배양액을 개발하기 위해서 일본야채시험장 표준액을 1/4배액, 1/2배액 및 1배액으로 조성하여 재배한 결과, 1/2배액에서 생육과 수량이 가장 높았으며 근권내 pH와 EC의 변화도 안정되었고, 식물체내 무기이온 합량도 적정치로 나타나 딜의 양분흡수특성에 적합할 것으로 판단되었다. 따라서 일본야채시험장 1/2 배액의 양수분 흡수율(n/w)을 기준으로 새로운 배양액을 조성하였으며, 이온의 조성은 NO$_3$―N 8.85, NH$_4$―N 0.55, P 2.1, K 6.2, Ca 2.8, Mg 1.7 me.L$^{-1}$였다. 딜의 순환식 NFT 재배용으로 개발한 배양액의 적합성 검정실험 결과, 근권내 pH와 EC는 저농도인 SCU 1/2배액을 제외하고는 변화폭이 크게 나타나지 않았다. 본 실험에서 개발된 SCU 1배액은 기존에 허브 배양액으로 사용된 일본 야채 시험장 배양액과 비교할 때 생육과 수량면에서 우수하였으며, 엽내 무기성분 함량도 적정수준을 나타내었다. 따라서, 본 실험에서 개발된 SCU 배양액은 딜의 NFT재배에 적합한 배양액이라 할 수 있다.

  • PDF

자체 제작한 자궁모형팬텀을 이용한 Convex probe 주사시간에 따른 자궁내부온도 평가 (Assessment of Uterine Internal Temperature according to the Time of Convex Probe Injection using a Self-made Uterine Model Phantom)

  • 이현경;허영철
    • 한국방사선학회논문지
    • /
    • 제13권6호
    • /
    • pp.895-900
    • /
    • 2019
  • 초음파는 인체에 무해하다고 알려져 산부인과에서 태아의 진단 및 발육상태 확인을 위해 널리 이용되고 있다. 진단 초음파의 장시간 사용은 체온 변화를 야기할 수 있지만 초음파로 인한 임신부의 자궁온도 변화에 대한 연구가 부족한 실정이다. 이에 본 연구에서는 자체 제작한 자궁모형팬텀을 이용하여 초음파 주사시간에 따른 온도 변화를 알아보고자 하였다. 조직등가 물질인 아크릴과 돼지 자궁을 이용하여 인체 자궁과 유사한 자궁모형팬텀을 자체 제작하였으며 초음파 장비와 4MHz convex probe를 사용하였다. 아크릴 수조 내부, 자궁내부, 대기온도 측정을 위해 3개의 탐침형 온도계를 설치하였고 측정대상의 온도를 분단위로 6시간, 총 361회 측정 한 결과 자궁모형팬텀의 온도가 상승되었음을 확인하였다. 본 연구를 통해 초음파로 인한 인체 체온 상승의 가능성을 확인 할 수 있었고 본 연구가 초음파 열 흡수효과 연구의 기초자료로 활용 될 것이라 사료된다.