• 제목/요약/키워드: Waste heat of fuel cell

검색결과 41건 처리시간 0.03초

대형 Community 건물의 연료전지 구동 복합열원 하이브리드 히트펌프 시스템 성능에 관한 해석적 연구 (Study on the Performance of Fuel Cell Driven Compound Source Heat Pump System to a Large Community Building)

  • 정동화;변재기;최영돈;조성환
    • 신재생에너지
    • /
    • 제4권3호
    • /
    • pp.23-35
    • /
    • 2008
  • In the present study, performances of fuel cell driven compound source hybrid heat pump system applied to a large community building are simulated. Among several renewable energy sources, ground, river, sea, and waste water sources are chosen as available alternative energies. The performance and energy cost are varied with the hybrid heat pump sources. The system design and operation process appropriate for the surrounding circumstance guarantee the high benefit of the heat pump system applied to a large community building. Th system is driven by fuel cell system instead of the late-night electricity due to the advantages of the low energy cost and waste heat with high temperature.

  • PDF

배열 이용형 흡수식 사이클 특성평가 (Characteristics Evaluation of Absorption Cycles using the Waste Heat)

  • 윤정인;권오경;문춘근
    • 태양에너지
    • /
    • 제18권4호
    • /
    • pp.23-32
    • /
    • 1998
  • Fuel cells supply electric power and heat at work, and their exhaust gas is comparatively clear. So they are in the limelight as one of the co-generation systems which behave friendly with the environment. Fuel cells discharge both steam and hot water. Accordingly, if we combine absorption heat pump driven by waste heat with fuel cells, we can construct an advanced energy conserving system. The purpose of this study is the objective for evaluating the possibilities of effectively utilizing waste heat of fuel cells as a heat source for the single and double effect absorption systems. Simulation studies on single and double effect absorption have been performed for water/lithium-bromide pair. The effectiveness of introducing a waste heat source of fuel cells is demonstrated. The result of this study showed that total efficiency was about 85% at rated operation and about 75% at 75% load operation. Absorption cycle moved to more strong concentration when fuel cell operated at 75% load.

  • PDF

스택 폐열을 이용한 연료전지 자동차용 열펌프 시스템의 성능 특성에 관한 연구 (A Study on the Performance Characteristics of a Heat Pump System using Stack Wast Heat in Fuel Cell Vehicles)

  • 전병용;고원빈;박윤철
    • 설비공학논문집
    • /
    • 제28권8호
    • /
    • pp.325-330
    • /
    • 2016
  • This study was conducted to develop a heating system for a fuel cell-driven electric vehicle. The system consists of a compressor, an expansion device and three heat exchangers. A conventional air source heat exchanger is used as primary heat exchanger of the system, and an additional water source heat exchanger is used as a pre-heater to supply heat to the upstream air of the primary heat exchanger. On the other hand, the third heat exchanger consists of a water-to-refrigerant heat exchanger. The heat source of the pre-heater and the water-refrigerant heat exchanger is the waste heat from the fuel cell's stack. In the experiment, the indoor and the outdoor air temperature were fixed, and the compressor speed, EEV opening and waste heat temperature were varied. The results indicate that the $COP_h$ of the proposed system is 3.01 when the system is operating at a 1,200 rpm compressor speed, 50% EEV opening, and $50^{\circ}C$ waste heat source temperature in air pre-heater operation. However, when the system uses a water-refrigerant heat exchanger, the $COP_h$ increases to up to 9.42 at the same compressor speed and waste heat source temperature with 75% EEV openings.

Thermal Analyses of Deep Geological Disposal Cell With Heterogeneous Modeling of PLUS7 Spent Nuclear Fuel

  • Hyungju Yun;Min-Seok Kim;Manho Han;Seo-Yeon Cho
    • 방사성폐기물학회지
    • /
    • 제21권4호
    • /
    • pp.517-529
    • /
    • 2023
  • The objectives of this paper are: (1) to conduct the thermal analyses of the disposal cell using COMSOL Multiphysics; (2) to determine whether the design of the disposal cell satisfies the thermal design requirement; and (3) to evaluate the effect of design modifications on the temperature of the disposal cell. Specifically, the analysis incorporated a heterogeneous model of 236 fuel rod heat sources of spent nuclear fuel (SNF) to improve the reality of the modeling. In the reference case, the design, featuring 8 m between deposition holes and 30 m between deposition tunnels for 40 years of the SNF cooling time, did not meet the design requirement. For the first modified case, the designs with 9 m and 10 m between the deposition holes for the cooling time of 40 years and five spacings for 50 and 60 years were found to meet the requirement. For the second modified case, the designs with 35 m and 40 m between the deposition tunnels for 40 years, 25 m to 40 m for 50 years and five spacings for 60 years also met the requirement. This study contributes to the advancement of the thermal analysis technique of a disposal cell.

대형 Community 건물의 연료전지 구동 지열원 히트펌프 냉.난방 시스템 성능에 관한 해석적 연구 (Analytical Study on the Performance of Fuel Cell Driven Ground Source Heat Pump Heating and Cooling System of a Large Community Building)

  • 변재기;정동화;최영돈;조성환
    • 설비공학논문집
    • /
    • 제21권6호
    • /
    • pp.355-366
    • /
    • 2009
  • In the present study, fuel cell driven ground source heat pump system is applied to a large community building and performance of the heat pump system is computationally analyzed. Conduction heat transfer between brine pipe and ground is analyzed by TEACH code to predict the performance of heat pump system. Predicted COP of the heat pump system and the energy cost were compared with variation of the location of the objective building the water saturation rate of soil and the driven powers of heat pump system. Significant reduction of energy cost can be accomplished by employing the fuel cell driven heat pump system in comparison with the late-night electricity driven system. It is due to the low electricity production cost of fuel cell system and the application of recovered waste heat generated during electricity production process to the heating of large community building.

Enhancement of the energy efficiency of hydrogen SOFC system by integrated cold energy utilization and waste heat recovery method

  • Nguyen Quoc Huy;Duong Phan Anh;Ryu Bo Rim;Lee Jin Uk;Kang Ho Keun
    • 한국항해항만학회:학술대회논문집
    • /
    • 한국항해항만학회 2022년도 추계학술대회
    • /
    • pp.160-161
    • /
    • 2022
  • Hydrogen is bridge fuel with high energy content and environmentally friendly to satisfy the stringent IMO regulation relating to greenhouse gas (GHG) emissions. There is growing interest in hydrogen in numerous nations and regions illustrated by an extensive range of research and development in technology. Regarding maritime applications, researchers have recognized the utilization of hydrogen as a fuel for fuel cells, a device that converts the chemical energy of the fuel to electrical energy. Solid oxide fuel cell (SOFC), with high working temperature, is easy to combine with the waste heat recovery cycles/devices to increase output power and thermodynamic performances as well. Furthermore, the cold energy from liquid hydrogen supplied to SOFC can also be used to generate more power. In this study, we proposed a SOFC integrated system with the idea of combining the waste heat recovery from the SOFC exhaust stream and cold energy utilization from LH2. The designation is aimed to target small-scale vessel which uses electric propulsion for short distances voyage.

  • PDF

선박 배기가스 활용에 따른 SOFC 시스템 공급가스의 온도특성에 관한 연구 (A study on temperature characteristic of the gases supplied to SOFC system by utilizing the ship exhaust gas)

  • 박상균
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제37권8호
    • /
    • pp.822-828
    • /
    • 2013
  • 고체산화물형 연료전지는 운전온도가 고온이기 때문에 연료전지 시스템으로 공급되는 가스의 열관리 문제가 중요하다. 본 연구에서는 선박 배기가스의 폐열을 선박 전원용 500kW급 SOFC 시스템으로 공급되는 연료, 가스 및 물을 가열하는 열원으로 활용한 경우에 연료전지 애노드 및 캐소드로 공급되는 가스의 온도특성에 관하여 검토하였다. 본 연구에서 제안한 연료전지 시스템에서는 선박의 배기가스를 활용하지 않고 연료전지에서 배출되는 배기가스만으로 연료전지 시스템으로 공급되는 가스의 가열원으로 활용한 경우의 애노드 및 캐소드로 공급되는 가스의 온도가 963K로 가장 높음을 알 수 있었다. 또한 엔진의 출력(배기가스의 유량)은 연료전지 스택으로 공급되는 가스의 온도에 큰 영향을 미치지 않음을 알 수 있었다.

배열을 이용한 연료전지 발전시스템 설계 (Design of Fuel Cell Power Generation System Using a Waste Heat)

  • 최영재;전재호;전중환
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2009년도 추계학술대회 논문집
    • /
    • pp.133-133
    • /
    • 2009
  • 연료전지는 연료의 화학적 에너지를 전기화학 반응을 통하여 직접 전기로 변환하기 때문에 에너지 전환효율이 높고 공해물질을 배출하지 않는 환경친화적인 고효율 발전방식으로, 특히 용융탄산염 연료전지(MCFC) 및 고체산화물 연료전지(SOFC)같은 고온형 연료전지의 경우 분산전원이나 중앙집중발전 같은 발전용에 적합한 연료전지로 평가받고 있다. 현재 MCFC 및 SOFC등의 발전용 연료전지 시스템의 효율은 약 50% 정도이며, 시스템의 발전효율을 높이기 위한 여러 연구가 진행되고 있다. 그 중에서 고온의 배열을 이용하여 연료전지 발전시스템의 효율을 향상시키기 위해 FuelCell Energy, Ansaldo Fuel Cells 및 Simens Westinghouse 등에서 수백 kW급의 fuel cell - gas turbine hybrid system에 대한 상용화 수준의 실증연구가 진행되었다. 본 연구에서는 발전용 연료전지 시스템의 발전효율을 높이기 위한 방안 중 하나로 배열을 이용하여 steam을 발생시켜 air amplifier에 사용함으로써 연료전지 시스템의 MBOP(Mechanical Balance of Plant)중 전력을 소비하는 air blower를 대체하여, 시스템 효율을 향상시키고 시스템의 가용성을 높일 수 있는 설계안에 대하여 논하고자 한다.

  • PDF

고온 고분자 연료전지를 이용한 데이터 센터용 CCHP 시스템의 에너지 절감 효과 (Energy Saving Effect of CCHP System Using High Temperature Polymer Electrolyte Fuel Cell for Data Centers)

  • 함성현;강태성;이원용;김민진
    • 한국수소및신에너지학회논문집
    • /
    • 제34권2호
    • /
    • pp.187-195
    • /
    • 2023
  • Data centers not only consume significant electricity to operate IT equipment, but also use a lot of electricity to cool the heat generated by IT equipment. The waste heat of a high-temperature polymer electrolyte fuel cell (HT-PEFC) is capable of producing cooling , so it can be effectively applied to data centers that require cooling throughout the year. The energy-saving effects of the proposed combined cooling, heat and power (CCHP) system using HT-PEFC. That was analyzed based on the annual energy consumption data of a specific data center. When the system was running at 100% of the year, It was shown that the installation of 1 MW of the proposed system can save 3,407 MWh of electrical energy per year. In addition, compared to the existing system, the annual power usage effectiveness can be improved from 2.0 to 1.57 and 6,293 MWh of extra heat energy per year can be produced to sell. Furthermore, sensitivity analysis was performed on the fuel cell operating temperature and current density to guide the appropriate installation capacity of the proposed system.

연료 재순환 이젝터를 이용한 연료전지-폐기물 기반 가역 고체 산화물 연료전지의 최적 설계 (Optimal Design of RSOFC System Coupled with Waste Steam Using Ejector for Fuel Recirculation)

  • 잡반티엔;이영덕;김영상;쿠엔;안국영
    • 한국수소및신에너지학회논문집
    • /
    • 제30권4호
    • /
    • pp.303-311
    • /
    • 2019
  • Reversible solid oxide fuel cell (RSOFC) has become a prospective device for energy storage and hydrogen production. Many studies have been conducted around the world focusing on system efficiency improvement and realization. The system should have not only high efficiency but also a certain level of simplicity for stable operation. External waste steam utilization was proved to remarkably increase the efficiency at solid oxide electrolysis system. In this study, RSOFC system coupled with waste steam was proposed and optimized in term of simplicity and efficiency. Ejector for fuel recirculation is selected due to its simple design and high stability. Three system configurations using ejector for fuel recirculation were investigated for performance of design condition. In parametric study, the system efficiencies at different current density were analyzed. The system configurations were simulated using validated lumped model in EBSILON(R) program. The system components, balance of plants, were designed to work in both electrolysis and fuel cell modes, and their off-design characteristics were taken into account. The base case calculation shows that, the system with suction pump results in slightly lower efficiency but stack can be operated more stable with same inlet pressure of fuel and air electrode.