• Title/Summary/Keyword: Waste Activated Sludge

Search Result 149, Processing Time 0.036 seconds

Biodeodorization of Trimethylamine by Biofilter Packed with Waste Tire-Chips (폐타이어칩 충진형 바이오 필터에 의한 Trimethylamine 제거)

  • Park, Hun-Ju;Kim, Chang-Gyun
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.30 no.8
    • /
    • pp.789-797
    • /
    • 2008
  • This study was conducted to investigate removal characteristics of gaseous trimethylamine(TMA) through biofilter packed with waste tire-chips. The sludge in this experiment was collected from an activated sludge operated in a wastewater treatment facility treating malodorous pollutants. The nominal amount of collected sludge was inoculated through packing materials in the filter. The removal efficiencies for varying concentrations and SVs(Space velocity) were assessed based on TMA, COD$_{Cr}$, NO$_3{^-}$-N, NO$_2{^-}$-N, NH$_4{^+}$-N and EPS(Extracellular Polymeric Substances) in leachate, since biofilter had been steady-stately operated. The influent concentration of 10 ppm of TMA was removed to approximately 95% regardless of changing SV at 120 and 180 hr$^{-1}$, but it was lowered to 80 to 90% at SV 240 hr$^{-1}$. As influent concentration was gradually increased from 5 to 55 ppm, the removal efficiencies of TMA were initially high for 95% in the range of 5 to 10 ppm, but lowered to 80% for 10 to 30 ppm. As a part of kinetic study for TMA decomposition, V$_m$(maximum substrate removal rate) and $K_s$(substrate infinity coefficient) were 14.3 g$\cdot$m$^{-3}$$\cdot$h$^{-1}$ and 0.043 g$\cdot$m$^{-3}$, respectively while adapted period was shown in the range of 100 to 150 hr. Also, the EPS concentration was consistently observed from the leachate showing 100 to 200 ppm, which indicates that biofilm has been continuously formed and sustained throughout tire-chips packed reactor.

A Study on the Water Reuse Systems (중수도개발연구(中水道開發研究))

  • Park, Chung Hyun;Lee, Seong Key;Chung, Jae Chul
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.4 no.4
    • /
    • pp.113-125
    • /
    • 1984
  • Water supply has been mainly dependent on the construction of the dams in Korea. It is difficult, however, to continue to construct dams for many reasons, such as the decrease of construction sites, the increase of construction costs, the compensation of residents in flooded areas, and the environmental effects. Water demands have increased and are expected to continue increasing due to the concentration of people in the cities, the rise of the living standard, and rapid industrial growth. It is acutely important to find countermeasures such as development of ground water, desalination, and recycling of waste water to cope with increasing water demands. Recycling waste water includes all means of supplying non-potable water for their respective usages with proper water quality which is not the same quality as potable water. The usages of the recycled water include toilet flushing, air conditioning, car washing, yard watering, road cleaning, park sprinkling, and fire fighting, etc. Raw water for recycling is obtained from drainage water from buildings, toilets, and cooling towers, treated waste water, polluted rivers, ground water, reinfall, etc. The water quantity must be considered as well as its quality in selecting raw water for the recycling. The types of recycling may be classified roughly into closed recycle systems and open recycle systems, which can be further subdivided into individual recycle systems, regional recycle systems and large scale recycle system. The treatment methods of wastewater combine biochemical and physiochemical methods. The former includes activated sludge treatment, bio-disc treatment, and contact aeration treatment, and the latter contains sedimentation, sand filtration, activated carbon adsorption, ozone treatment, chlorination, and membrane filter. The recycling patterns in other countries were investigated and the effects of the recycling were divided into direct and indirect effects. The problems of water reuse in recycle patterns were also studied. The problems include technological, sanitary, and operational problems as well as cost and legislative ones. The duties of installation and administrative organization, structural standards for reuse of water, maintenance and financial disposal were also studied.

  • PDF

Biodegradation of Phenol by Comamonas testosteroni DWB-1-8 Isolated from the Activated Sludge of Textile Wastewater (섬유 폐수 활성 슬러지에서 분리한 Comamonas testosteroni의 생물학적 페놀 분해)

  • Kwon, Hae Jun;Choi, Doo Ho;Kim, Mi Gyeong;Kim, Dong-Hyun;Kim, Young Guk;Yoon, Hyeokjun;Kim, Jong-Guk
    • Journal of Life Science
    • /
    • v.30 no.2
    • /
    • pp.156-161
    • /
    • 2020
  • Since industrialization, the production and utilization of various chemicals has contributed to improving the quality of our lives, but the subsequent discharge of massive waste is inevitable, and environmental pollution is becoming more serious every day. Exposure to chemicals as a result of environmental pollution is having a negative effect on human health and the ecosystem, and cleaning up the polluted environment that can affect our lives is a very important issue. Toxic aromatic compounds have been detected frequently in soil, groundwater, and wastewater because of the extensive use of oil products, and phenol, which is used to produce synthetic resins, textiles, and dyes, is one of the major pollutants, along with insecticides and preservatives. Phenol can cause dyspnea, headache, vomiting, mutation, and carcinogenesis. Phenol-degrading bacterium DWB-1-8 was isolated from the activated sludge of textile wastewater; this strain was identified as Comamonas testosteroni by 16S rRNA gene sequencing. The optimal culture conditions for the cell growth and degradation of phenol were 0.7% K2HPO4, 0.6% NaH2PO4, 0.1% NH4NO3, 0.015% MgSO4·7H2O, 0.001% FeSO4·7H2O, an initial pH of 7, and a temperature of 30℃. The strain was also able to grow by using other toxic compounds, such as benzene, toluene, or xylene (BTX), as the sole source of carbon.

Treatment of Malodorous Waste Air Containing Ammonia Using Biofilter System (바이오필터시스템을 이용한 암모니아 함유 악취폐가스 처리)

  • Lee, Eun Ju;Park, Sang Won;Nam, Dao Vinh;Chung, Chan Hong;Lim, Kwang-Hee
    • Korean Chemical Engineering Research
    • /
    • v.48 no.3
    • /
    • pp.391-396
    • /
    • 2010
  • In this research the characteristics of ammonia removal from malodorous waste-air were investigated under various operating condition of biofiilter packed with equal volume of rubber media and compost for the efficient removal of ammonia, representative source of malodor frequently generated at compost manufacturing factory and publicly owned facilities. Then the optimum conditions were constructed to treat waste-air containing ammonia with biofilter. Biofilter was run for 30 days(experimental frequency of 2 times/day makes 60 experimental times.) with the ammonia loading from $2.18g-N/m^3/h$ to $70g-N/m^3/h$ at $30^{\circ}C$. The ammonia removal efficiency reached almost 100% for I through IV stage of run to degrade up to the ammonia loading of $17g-N/m^3/h$. However the removal efficiency dropped to 80% when ammonia loading increased to $35g-N/m^3/h$, which makes the elimination capacity of ammonia $28g-N/m^3/h$ for V stage of run. However, the removal efficiency remained 80% and the maximum elimination capacity reached $55g-N/m^3/h$ when ammonia loading was doubled $70g-N/m^3/h$ for VI stage of run. Thus the maximum elimination capacity exceeded $1,200g-N/m^3/day$(i.e., $50g-N/m^3/h$) of the experiment of biofilter packed with rock wool inoculated with night soil sludge by Kim et al.. However, the critical loading did not exceed $810g-N/m^3/day$ (i.e., $33.75g-N/m^3/h$) of the biofilter experiment by Kim et al.. The reason to exceed the maximum elimination capacity of Kim et al. may be attributed to that the rubber media used as biofilter packing material provide the better environment for the fixation of nitrifying and denitrification bacteria to its surface coated with coconut based-activated carbon powder and well-developed inner-pores, respectively.

A Study on Removal of Organism and Nitrogen, Phosphorus in Wastewater Treatment Process Using Nitrifier Activated Reactor (질산화균 활성화조를 이용한 하수처리 공정에서의 유기물 및 질소, 인 제거에 관한 연구)

  • Dong, Young-tak;Seo, Dong-whan;Bae, Yu-jin;Park, Ju-seok
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.21 no.6
    • /
    • pp.727-735
    • /
    • 2007
  • The use of water by cities is increasing owing to industrialization, the concentration of population, and the enhancement of the standard of living. Accordingly, the amount of waste water is also increasing, and the degree of pollution of the water system is rising. In order to solve this problem, it is necessary to remove organisms and suspended particles as well as the products of eutrophication such as nitrates and phosphates. This study developed a high-end treatment engineering solution with maximum efficiency and lower costs by researching and developing a advanced treatment engineering solution with the use of Biosorption. As a result, the study conducted a test with a $50m^3/day$ Pilot Scale Plant by developing treatment engineering so that only the secondary treatment satisfies the standard of water quality and which provided optimal treatment efficiency along with convenient maintenance and management. The removal of organisms, which has to be pursued first for realizing nitrification during the test period, was made in such a way that there would be no oxidation by microorganisms in the reactor while preparing oxygen as an inhibitor for the growth of microorganism in the course of moving toward the primary settling pond. The study introduced microorganisms in the endogeneous respiration stage to perform adhesion, absorption, and filtering by bringing them into contact with the inflowing water with the use of a sludge returning from the secondary settling pond. Also a test was conducted to determine how effective the microorganisms are as an inner source of carbon. The HRT(Hydraulic Retention Time) in the nitrification tank (aerobic tank) could be reduced to two hours or below, and the stable treatment efficiency of the process using the organisms absorbed in the NAR reactor as a source of carbon could be proven. Also, given that the anaerobic condition of the pre-treatment tank becomes basic in the area of phosphate discharge, it was found that there was excellent efficiency for the removal of phosphate when the pre-treatment tank induced the discharge of phosphate and the polishing reactor induced the uptake of phosphate. The removal efficiency was shown to be about 94.4% for $BOD_5$. 90.7% for $COD_{Cr}$ 84.3% for $COD_{Mn}$, 96.0% for SS, 77.3% for TN, and 96.0% for TP.

Empirical Study on Applicability of Phosphorus Recovery Process in Wastewater Treatment Plant (하수처리시설에서 인 회수공정의 도입 가능성에 대한 실증적 검토)

  • Park, Na-ri;Chang, Hyang-Youn;Lim, Hyun-Man;Ahn, Kwang-Ho;Kim, Weon-Jae
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.39 no.1
    • /
    • pp.40-49
    • /
    • 2017
  • In this study, we have made the annual total phosphorus (TP) mass balance diagrams for I wastewater treatment plant by utilizing the data of flow rate and TP of each process and tried to choose the optimum unit process empirically for phosphorus recovery. For the applicability evaluation, we have suggested several quantitative indices of flow rate, TP concentration, TP load and SS. Based on the analyses of TP mass balance, it became clear for reducing TP load of the wastewater treatment plant that it is efficient to recover phosphorus from the side stream in which the amount of flow rate is just 1/16, but TP concentration and load are 78 and 4.8 times larger than those of the influent of the plant. After the detailed applicability evaluation for the side stream, it could be concluded that the unit process of waste activated sludge thickener supernatant or dehydration filtrate are appropriate. Meanwhile, we did fundamental experiments utilizing the dewatering filtrate with TP concentration of 141.5 mg/L. After adjusting pH 10 and $Ca^{2+}$ concentration 250, 500, 1000 mg/L, it was stirred slowly. As a result, the $PO_4-P$ and TP removal efficiencies were above 95 percent; the results of the experiment imply the applicability of phosphorus recovery process in a wastewater treatment plant strongly.

On-site Output Survey and Feed Value Evaluation on Agro- industrial By-products (농산업부산물들에 대한 배출 현장 조사 및 사료적 가치 평가)

  • Kwak, W. S.;Yoon, J. S.
    • Journal of Animal Science and Technology
    • /
    • v.45 no.2
    • /
    • pp.251-264
    • /
    • 2003
  • This study was conducted to make on-site survey on the output pattern and utilization situation of 19 by-products selected, to evaluate their nutritional characteristics, to find out a reliable index with which digestion of by-products can be predicted on the basis of chemical compositions analyzed and to diagnose the risk of using book values in the absence of the actual values analyzed for diet formulation. Production and utilization situations of by-products were quite various. Nutritionally, fruit processing by-products such as apple pomace (AP), pear pomace (PP), grape pomace (GP), and persimmon peel (PSP), and bakery by-products (BB) were classified as energy feeds. Soybean curd meal (SCM), animal by- products such as blood (BD), feather meal (FM) and poultry by-products (PB), and activated milk processing sludge (AMS) were classified as protein feeds. Soy hulls (SH), spent mushroom compost (SMC), barley malt hulls (BMH), waste paper (WP) and broiler litter (BL) were classified as roughage. Rumen contents (RC) and restaurant food waste (FW) were nutritionally analogous to complete diets for cattle and swine, respectively. Compared to soybean meal (SBM), BD and FM contained high (P<0.05) levels of amino acids and barley malt sprouts (BMS), AMS and FW contained low (P<0.05) levels of amino acids. Enzymatic (pepsin) digestibilities of proteinaceous feeds ranged between 99 and 66%. In vitro DM digestibility was high (P<0.05) in the order of FW, BB, AP, SH, PP, PSP, BMH, BMS, SCM, GP, RC, PB, BL, WP, SMC, AMS, FM and BD. In vitro DM digestibility had the highest correlation (r=0.68) with nonfibrous carbohydrate among chemical components. Differences between analyzed values of chemical components and book values were considerable. Caution is required in using book values when large amount of by-products are used in diets.

Treatment and Attachment Characteristics of Biofilm of Phanerochaete chrysosporium PSBL-1 in Wastewater (Phanerochaete chrysosporium PSBL-1 생물막을 이용한 오.폐수 처리 및 부착특성)

  • Lee, Soon-Young;Kang, Ki-Cheol;Won, Chan-Hee
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.30 no.3
    • /
    • pp.271-277
    • /
    • 2008
  • The biofilm of white-rot fungi fully exposed in atmosphere are that operation is easy, management cost and energy waste is low. To develop biofilm of white-rot fungi fully exposed in atmosphere, basic test are as follows. To select most effective microoganism species, investigated treatment characteristics of wastewater containing non-biodegradable material for three species of white-rot fungi(Phanerochaete chrysosporium PSBL-1, Phanerochaete chrysosporium KCTC 6147, Trametes sp. KFCC 10941) and activated sludge. And then investigated attached and detached biomass of selected white-rot fungi species on HBC ring surface. Among the three strains tested, P. chrysosporium PSBL-1 and P. chrysosporium KCTC 6147 showed higher efficiency for organics removal than Trametes sp. KFCC 10941, and P. chrysosporium PSBL-1 showed higher efficiency for nitrogen removal than P. chrysosporium KCTC 6147 and Trametes sp. KFCC 10941. Respectively, 51$\sim$59.8%, 57.5$\sim$60.3% of NBDCOD was removed for P. chrysosporium PSBL-1 and P. chrysosporium 6147 in pH 3.5$\sim$5.5. TN removal efficiency showed 39.3$\sim$85.3%, 3.4$\sim$7.6% for P. chrysosporium PSBL-1 and P. chrysosporium 6147 in pH 4.5$\sim$11.5 respectively. Considered that white-rot fungi remove organism and nitrogen simultaneously, the microorganism selected white-rot fungi P. chrysosporium PSBL-1. White-rot fungi P. chrysosporium PSBL-1 attached on HBC ring surface 4,538 mg/L, 4,546 mg/L, 4,531 mg/L after 5 minutes, 4,575 mg/L, 4,573 mg/L, 4,568 mg/L after 10 minutes from initial MLSS 4,600 mg/L in pH 4, 7 and 10 respectively. Also detached biomass is negligible from right after attachment to 10 day in pH 4, 7 and 10.

Evaluating the Removal Efficiency of Organic Compounds and Nitrogen Depending on Loading Rate in Wastewater Treatment from Fisheries Processing Plant Using an Entrapped Mixed Microbial Cell Technique (미생물 강제포획기술을 이용한 수산물 가공공장 폐수처리에서 부하율에 따른 유기물 및 질소의 제거 효율성 평가)

  • Jeong Byung-Cheol;Chang Soo-Hyun;Jeong Byung-Gon
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.9 no.1
    • /
    • pp.14-20
    • /
    • 2006
  • In this study, the feasibility of simultaneous removal of organic materials and nitrogen in the waste-water from fisheries processing plant was evaluated using entrapped mixed microbial cell technique(EMMC) process. The experiment was performed using activated sludge from municipal sewage treatment plant which was immobilized with gel matrix by cellulose triacetate. It was found that the stable operation at the treatment system which is composed of anoxic and oxic tank, was possible when the organic and nitrogen loading rates were increased stepwise. The organic and nitrogen loading rates were applied from 0.65 to $1.72kgCOD/m^3/d$ and from 0.119 to $0.317kgT-N/m^3$ with four steps, respectively. The maximum nitrogen loading rate which could satisfy the regulated effluent standard of nitrogen concentration, was $0.3kgT-N/m^3/d$. The removal efficiency of total nitrogen was decreased apparently as increasing nitrogen loading rates, whereas the removal efficiency of ammonium nitrogen was effective at the all tested nitrogen loading rates. Therefore, it was concluded that nitrification was efficient at the system. Nitrate removal efficiency ranged from 98.62% to 99.51%, whereas the nitrification efficiency at the oxic tank ranged 94.0% to 96.9% at the tested loading rates. The removal efficiencies of chemical oxygen demand(COD) and those of total nitrogen at the entire system ranged from 94.2% to 96.6% and 73.4% to 83.4%, respectively.

  • PDF