• Title/Summary/Keyword: Washer power

Search Result 10, Processing Time 0.023 seconds

A Study on the Power Transmission Design of a High Speed Automatic Washer (고속 세탁시스템의 구동 설계)

  • 이장무;윤구영
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1996.11a
    • /
    • pp.872-876
    • /
    • 1996
  • Most studies of rotary machinery design have been performed to establsih a new mechanism or a dramatic combination of machine elements for the power transmission. Although the rotary machine is worked very efficiently, that still has a major work to better performance which is the optimization of the selected mechanism for the mechanical efficiency, low vibration and noise, or customer interest. This work presents a practical approach used for washer's efficiency and machinery vibration and noise reduction along with a systematic procedure. Also for the confirming the study, a computer simulation program and a real working mock-up are developed and used to show very good agreement with the analytical result.

  • PDF

A Study on Energy Reduction in an Outdoor Air Conditioning System for Semiconductor Manufacturing Cleanrooms Using Water Spray Humidification (반도체 클린룸용 외기공조시스템의 수분무 가습을 이용한 에너지절감에 관한 연구)

  • Song, Won-Il;Kim, Ki-Cheol;Yoo, Kyung-Hoon;Shin, Dae-Kun;Tae, Kyung-Eung;Kim, Yong-Sik;Park, Dug-Jun
    • Particle and aerosol research
    • /
    • v.13 no.2
    • /
    • pp.65-77
    • /
    • 2017
  • In recent large-scale semiconductor manufacturing cleanrooms, the energy consumption in outdoor air conditioning (OAC) systems to heat, humidify, cool and dehumidify outdoor air(OA) represents about 40~50 % of the total cleanroom power consumption required to maintain cleanroom environment. Therefore, the assessment of energy consumption in outdoor air conditioning systems is essential for reducing the outdoor air conditioning load for a cleanroom. In the present study, an experiment with an outdoor air flow rate of $1,000m^3/h$ was conducted to compare the energy consumption in steam humidification, simple air washer, exhaust air heat recovery type air washer and dry cooling coil(DCC) return water heat recovery type air washer OAC systems. Besides, a numerical analysis was carried out to evaluate the annual energy consumption of the aforementioned four OAC systems. It was shown that the simple air washer, exhaust air heat recovery type air washer and DCC return water heat recovery type air washer OAC systems using water spray humidification were more energy-efficient than the steam humidification OAC system. Furthermore the DCC return water heat recovery type air washer OAC system was the most energy-efficient.

Comparison of detergency effectiveness by the type of household washer, detergent and soil - Focused on detergency, rinsing, fabric damage and tanglement - (가정용 세탁기, 세제 및 오염의 종류별 세탁 성능 비교 - 세탁성, 헹굼성, 섬유손상도, 엉킴도를 중심으로 -)

  • Piao, Shujing;Park, Myung-Ja
    • The Research Journal of the Costume Culture
    • /
    • v.21 no.6
    • /
    • pp.950-960
    • /
    • 2013
  • The purpose of this research is to provide accurate information of household washers and detergents for consumers, so that help the producers who make washing machine and detergent to get basic material and also help consumers to choose washing machine. Experiment was proceed with two type of washers to compare energy consumption, washing performance, rinsing effectiveness further, damage caused by entanglement of laundry and fabric was assessed. Detergent P and T were used to compare the performance related to differences of ingredients of detergent. Soiled fabrics of EMPA 108 set were used to evaluate performance of washing by different types of contamination. A summary of experimental results are : First, for the consumption of water, drum-type washer consumed 53% less than pulsator-type washer. On the other hand, the washing time was almost similar for both these machines, but pulsator-type washer showed shorter progress, implying that power saving was more efficient in this case. Second, the drum-type washer showed better performance for contamination with all types of detergent, but the pulsator-type washer showed better rinsing performance. Third, the drum-type washer performed less data of tangle level and fabric damage. Fourth, detergent "P" exhibited better washing performance than did detergent "T", regardless of the type of soil. And with no limit of detergent variety, water-soluble protein soil showed high removal rate, liposoluble soil especially pigment was hardly removed.

An Experimental Study on Energy Consumption of Air Washer Outdoor Air Conditioning Systems for Semiconductor Manufacturing Clean Rooms (반도체 클린룸용 에어와셔 외기공조시스템의 에너지소비량에 관한 실험적 연구)

  • Kim, Ki-Cheol;Kim, Hyung-Tae;Song, Gen-Soo;Yoo, Kyung-Hoon;Son, Seung-Woo;Shin, Dae-Kun;Park, Dug-Jun
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.24 no.4
    • /
    • pp.297-305
    • /
    • 2012
  • In recent large-scale semiconductor manufacturing clean rooms, the energy consumption of outdoor air conditioning systems to heat, humidify, cool and dehumidify incoming outdoor air represents about 45% of the total air conditioning load required to maintain a clean room environment. Therefore, the energy performance evaluation and analysis of outdoor air conditioning systems is useful for reducing the outdoor air conditioning load for a clean room. In the present study, an experiment was conducted to compare the energy consumption of outdoor air conditioning systems with a simple air washer, an exhaust air heat recovery type air washer and a DCC return water heat recovery type air washer. It was shown from the present lab-scale experiment with an outdoor air flow of 1,000 $m^3/h$ that the exhaust air heat recovery type and DCC return water heat recovery type air washer outdoor air conditioning systems were more energy-efficient for the summer and winter operations than the simple air washer outdoor air conditioning system and furthermore, the DCC return water heat recovery type one was the most energy-efficient in the winter operation.

Construction and Testing of a radiation-beam powered TA (ThermoAcoustic) washer for grease removal

  • Chen, Kuan;DaCosta, David H.;Kim, Yeongmin;Oh, Seung Jin;Chun, Wongee
    • Journal of the Korean Solar Energy Society
    • /
    • v.35 no.1
    • /
    • pp.21-28
    • /
    • 2015
  • A small washer powered directly and solely by thermal radiation was constructed and tested to explore the feasibility of using solar energy or other types of thermal radiation for washing and cleaning. In principle, TA (ThermoAcoustic) washers have the benefits of simpler design and operation and fewer energy conversion processes, thus should be more energy efficient and cost less than electric washing/cleaning systems. The prototype TA converter we constructed could sustain itself with consistent fluid oscillations for more than 20 minutes when powered by either concentrated solar radiation or an IR (infrared) heater. The frequencies of water oscillations in the wash chamber ranged from 2.6 to 3.6 Hz. The overall conversion efficiency was lower than the typical efficiencies of TA engines. Change in water temperature had little effect on the oscillatory flow in the TA washer due to its low efficiency. On the other hand higher water temperatures enhanced grease removal considerably in our tests. Methods for measuring the overall conversion efficiency, frictional loss, and grease removal of the TA washing system we designed were developed and discussed.

Unbalance Detection Algorithm of Washer Using Band-Pass Filter (대역통과 필터를 이용한 세탁기의 언밸런스 감지 알고리즘)

  • Kim, Hack Jun;Cho, Kwan Yuhl;Kim, Hag Wone;Nam, Myung Joon
    • Proceedings of the KIPE Conference
    • /
    • 2015.07a
    • /
    • pp.215-216
    • /
    • 2015
  • 세탁기의 탈수 행정 시, 터브 내 세탁포가 고르게 분포되어 있지 않으면 세탁포가 한쪽방향으로 쏠려 터브가 크게 흔들리는 언밸런스 현상이 발생하게 된다. 이런 언밸런스 현상은 전동기 및 세탁기에 기구적인 손상을 발생시키기 때문에 즉시 감지하여 탈수 행정을 중지시키도록 해야 한다. 본 논문에서는, 세탁기의 언밸런스 현상이 발생 시 나타나는 전동기의 기계적인 주파수를 갖는 전류 리플을 가변 밴드패스 필터를 이용하여 측정한다. 측정된 전류 리플을 바탕으로 언밸런스 현상을 감지하는 알고리즘을 제안한다.

  • PDF

An Assessment of Energy Consumption in Steam-Humidification- and Water-Spray-Humidification-Type Outdoor Air Conditioning Systems for Semiconductor Manufacturing Clean Rooms (반도체 클린룸용 증기가습 및 수분무가습 외기공조시스템의 에너지소비량 평가)

  • Kim, Ki-Cheol;Song, Gen-Soo;Kim, Hyung-Tae;Yoo, Kyung-Hoon;Shin, Dae-Kun;Park, Dug-Jun
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.25 no.2
    • /
    • pp.55-63
    • /
    • 2013
  • For a large-scale semiconductor manufacturing clean room, the energy consumed in an outdoor air conditioning system to heat, humidify, cool and dehumidify incoming outdoor air is very large. In particular, the energy requirement to humidify outdoor air in the winter season is generally known to be high. Recently, in order to overcome the high energy consumption nature of a steam generator in a conventional steam humidification type outdoor air conditioning system, an air washer is often introduced instead of the steam generator in the outdoor air conditioning system, which can be called a water spray humidification type outdoor air conditioning system. Therefore, the assessment and comparison of the annual energy consumed in the steam humidification type and the water spray humidification type outdoor air conditioning systems deserves to be examined in order to reduce the outdoor air conditioning load of a clean room. In the present study, a numerical analysis was conducted to obtain the annual electric power consumption of the two outdoor air conditioning systems. It was shown from the comparison of the numerical results that the water spray humidification type outdoor air conditioning system can reduce about 30% of annual electric power consumption of the steam humidification type outdoor air conditioning system.

Preliminary System Design of STEP Cube Lab. for Verification of Fundamental Space Technology (우주기반기술 검증용 극초소형 위성 STEP Cube Lab.의 시스템 개념설계)

  • Kwon, Sung-Cheol;Jung, Hyun-Mo;Ha, Heon-Woo;Han, Sung-Hyun;Lee, Myung-Jae;Jeon, Su-Hyeon;Park, Tae-Young;Kang, Su-Jin;Chae, Bong-Gun;Jang, Su-Eun;Oh, Hyun-Ung;Han, Sang-Hyuk;Choi, Gi-Hyuk
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.42 no.5
    • /
    • pp.430-436
    • /
    • 2014
  • The mission objective of STEP Cube Lab. (Cube Laboratory for Space Technology Experimental Project) classified as a pico-class satellite is to verify the technical effectiveness of payloads such as variable emittance radiator, SMA washer, oscillating heat pipe and MEMS based solid propellant thruster researched at domestic universities. In addition, the MEMS concentrating photovoltaic power system and the non-explosive holding and separation mechanism with the advantages of high constraint force and low shock level will be developed as the primary payloads for on-orbit verification. In this study, the feasibility of the mission actualization has been confirmed by the preliminary system design.

Comparative Study on Energy Consumption in Steam-Humidification- and Water-Spray-Humidification-Type Outdoor Air-Conditioning Systems for Semiconductor Manufacturing Clean Rooms (반도체 클린룸용 증기가습 및 수분무가습 외기공조시스템의 에너지소비량 비교연구)

  • Kim, Hyung-Tae;Song, Gen-Soo;Kim, Ki-Cheol;Yoo, Kyung-Hoon;Son, Seung-Woo;Shin, Dae-Kun;Park, Dug-Jun;Kwon, Oh-Myung
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.35 no.12
    • /
    • pp.1249-1255
    • /
    • 2011
  • In modern large-scale semiconductor manufacturing clean rooms, the energy consumed by the outdoor air-conditioning system during heating, humidification, cooling, and dehumidification of the incoming outdoor air represents about 45% of the total air-conditioning load required to maintain a clean-room environment. In particular, the energy required for humidification of the outdoor air in winter is very high. Therefore, evaluation and comparison of the energy consumption in key humidification systems, viz., steam-humidification and water-spray-humidification systems, used in outdoor air-conditioning systems would be useful to reduce the outdoor air-conditioning load in clean rooms. In the present study, an experiment with an outdoor air flow of 1000 $m^3$/h was conducted to compare the air-conditioning process and energy consumption in outdoor air-conditioning systems with electrodeboiler steam humidifiers and air-washer water spray humidification systems. The experimental results showed that the water-spray-humidification-type outdoor air-conditioning system consumed less electrical power than did the steam-humidification-type system and was more energy efficient during winter.

Effect of Drying Time and Additives regarding the Physical Properties of Vegetable Fatty Acid Soap (식물성 지방산 비누의 물리적 특성에 대한 건조시간과 첨가물의 효과)

  • Lee, Sung-Hee;Lee, Ki-Young
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.6
    • /
    • pp.4032-4038
    • /
    • 2014
  • Vegetable fatty acid solid soap requires a drying process for moisture evaporation and hardness after being manufactured through saponification. Although the soap is manufactured by mixing additives mainly from natural ingredients, existing studies have focused primarily on the usability of vegetable solid soap. Consequently, research into the physical properties of vegetable fatty acid solid soap mixed with natural ingredients has been unsatisfactory. Therefore, this study attempted to compare and observe the changes in the physical properties (pH, surface tension, critical micelle concentration, and cleansing power) of solid soap in accordance with the drying period and additives (tea tree E.O and $TiO_2$) using pH paper, the Du Nouy measurement method, sedimentation method, and ultrasound washer. Regardless of the mixture with additives, vegetable fatty acid solid soap showed the same pH, and there was no change in the pH while maintaining pH 8 beginning from the $2^{nd}$ weeks to $12^{th}$ weeks of drying. In addition, as a result of measuring the surface tension and CMC, regardless of the drying period, only the soap added with $TiO_2$ showed an even value of 62.5mg/L, whereas the other soap specimens showed a decline in CMC to 25mg/L on the fourth week of drying. As a result of measuring the detergency, the removal efficiency of vegetable fatty acid solid soap mixed with tea tree E.O and $TiO_2$ and dried for four weeks was 4.50~4.65%, which was higher than that of the vegetable fatty acid solid soap without additives (3.62~3.92%).