• Title/Summary/Keyword: Warm climate season

Search Result 46, Processing Time 0.028 seconds

Rectal Temperature of Lactating Sows in a Tropical Humid Climate according to Breed, Parity and Season

  • Gourdine, J.L.;Bidanel, J.P.;Noblet, J.;Renaudeau, D.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.20 no.6
    • /
    • pp.832-841
    • /
    • 2007
  • Rectal Temperature;Thermoregulation;Sows;Breed;The effects of season (hot vs. warm) in a tropical humid climate, parity (primiparous vs. multiparous) and breed (Creole: CR, Large White: LW) on rectal temperature (RT) were studied for a total of 222 lactations obtained in 85 sows (43 CR and 42 LW; 56 primiparous and 166 multiparous) over a 28-d lactation, between June 2002 and April 2005. Mean daily ambient temperature was higher during the hot season than during the warm season (26.0 vs. $24.1^{\circ}C$) and relative humidity was high and similar in both seasons (89% on average). At farrowing, BW was lower (172 vs. 233 kg) and backfat thickness was higher (37 vs. 21 mm) in CR than in LW sows (p<0.01). During the hot season, the reduction of average daily feed intake (ADFI) was more pronounced in LW than in CR sows (-920 vs. -480 g/d, p<0.05). Rectal temperature was higher at 1200 than at 0700hr, which coincides with the maximum and the minimum values of daily ambient temperature. The daily RT increased ($+0.9^{\circ}C$; p<0.01) between d -3 and d 7 (d 0: farrowing day), remained constant between d 7 and d 25 and decreased (p<0.01) thereafter (i.e. $-0.6^{\circ}C$ between d 25 and d 32). The average daily RT was significantly higher during the hot than during the warm season (38.9 vs. $38.6^{\circ}C$; p<0.01). It was not affected by breed, but the difference in RT between the hot and warm seasons was more pronounced in LW than in CR sows (+0.4 vs. $+0.2^{\circ}C$; p<0.05). Parity influenced the RT response; it was greater in primiparous than in multiparous sows (38.9 vs. $38.7^{\circ}C$; p<0.01). This study suggests that thermoregulatory responses to heat stress can differ between breeds and between parities.

Seasonal Variation of the Surface Heat Budget in the Gumi Reservoir of Nakdong River (낙동강 구미 보의 수면 열수지 계절 변화)

  • Kim, Hak-Yun;Seo, Kwang-Su;Cho, Chang-Bum;Kim, Hae-Dong
    • Journal of Environmental Science International
    • /
    • v.25 no.8
    • /
    • pp.1057-1063
    • /
    • 2016
  • The heat budget is investigated in the Gumi Reservoir of the Nakdong river. In warm climate season, solar radiation effects play a important role in the change of water temperature. The features of the surface heat balance are almost derived by the latent heat flux and the solar radiation flux. On the other hand, in cold climate season, change of heat stored in the water is mainly dominated by latent and sensible heat transfer between water and air, since flux of solar radiation and loss of outgoing long wave radiation balance approximately. For the annual averages, net flux of radiation, evaporation(latent heat) loss are dominant in the Gumi reservoir. The evaporation losses are dominant from spring to early winter. This means that the Gumi reservoir rolls like a lake of thermal medium or deep depth.

Evaluation of Mitigation Effect of Upo-Swamp on the Air temperature Variation with Nighttime Cooling Rate (야간 냉각율을 이용한 우포늪의 기온변화 완화효과 평가)

  • Park, Myung-Hee;Kim, Hae-Dong
    • Journal of Environmental Science International
    • /
    • v.20 no.3
    • /
    • pp.309-319
    • /
    • 2011
  • In this study, we investigated the effects of Upo-swamp upon local thermal environment with nighttime cooling rate. To do this, we set up the AWS(Automatic Weather observation System) over the central part of Upo-swamp on the early October 2007. We conducted the study by comparing the AWS data with another weather data observed by several meteorological observations of the Korea Meteorological Administration located at the vicinity of Upo-swamp for one year. The air temperature of Upo-swamp was higher than that of the surrounding in cold-climate season. But it was opposite in warm-climate season. We confirmed that Upo-swamp roles to mitigate the daily and annual air temperature ranges. And the daily air temperature variation of Upo-swamp lagged behind the land one. This phenomenon represent that the heat reservoir capacity of Upo-swamp is much larger than that of the ground.

Experimental Study on Developing of Double Facade System dealing with the various climatic Conditions (다양한 기후조건에 대응하는 이중외피시스템 개발에 관한 실험적 연구)

  • Lee, Keon-ho;Kim, Hyeon-soo;Jang, Dae-hee;Moon, Soo-young
    • KIEAE Journal
    • /
    • v.5 no.2
    • /
    • pp.19-26
    • /
    • 2005
  • Every site has a different given geometrical and climatic condition, which influenced not only the lifestyle of the humanbeings but also the regional architecture. For example, on a cold region, the reduction of the energy loss is necessary, like an igloo, which has a littlest energy loss at hemisphere. Or on a warm region, the house must be protected thermally from the overheating at the sunshining. like a huge shading. An architectural interpretation in the (extreme) moderate climate, like Korea, has always tried to satisfy the both opposite demands simultaneously. A facade, which divides out- and inside, has an ideal position to lead the regulated regional climatic conditions into the room. The Double Facade System(DFS) is well known as an innovative solution in the european countries, like Germany. It provides an reasonable alternative, which can achieve these goals at the same time. A Double Facade System provides an effective sunshade, which means a cooling energy reduction at the warm season. In addition, it enables a natural ventilation at the cold season with the preheating at the system as well as spring and autumn. An ordinary Single Facade System with a inside or outside sun blind provides a solution just for a specified season, like a summer or winter. But the Double Facade System can deal with the various climatic conditions in the moderate climate.

Oceanography in the Waters Adjacent to Kamchatka and Kurile islands in the Northwestern Pacific - II (북서태평양 명태 어장의 해황 - 2 . 기후의 특성 -)

  • Han, Young-Ho
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.13 no.1
    • /
    • pp.17-25
    • /
    • 1977
  • For four calender years (1971-1974), daily observations of weather conditions (air temperature, humidity, wind speed, wind direction, cloud amount, fog, precipitation etc.) at six stations in the north western Pacific Ocean are used to calculate mean monthly values and to check extra-conditions. At Petropavlosk and Miko'skoe, where indicate the characteristics of modified continental climate, the temperature and humidity are high in summer, and Iow in winter. At A Dak and She Mya, where indicate the characteristics of warm current type maritime climate, humidity is high in all season and annual range of air temperature is nearly negligible. At Simusir and Vasi!' eva, where indicate the characteristics of cold current type maritime climate, humidity is high in all season and annual range of air temperature is $15^{\circ}C.$ As dry cooling power is relatively high in winter, working condition on deck is bad. Most of fogs are advection fog in the area of cold current type climate in summer.

  • PDF

Monitoring Nutritional Status of Dairy Cows in Taiwan Using Milk Protein and Milk Urea Nitrogen

  • Hwang, Sen-Yuan;Lee, Mei-Ju;Chiou, Peter Wen-Shyg
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.13 no.12
    • /
    • pp.1667-1673
    • /
    • 2000
  • The climate and marketing system of raw milk in Taiwan create problems in balance feeding of protein and energy in lactating cows in Taiwan. Level of urea nitrogen both in bulk milk and serum reflects ruminal protein degradation and post-ruminal protein provision, whereas milk protein concentration responds to dietary energy intake and bacterial protein production in the rumen. Establishment of a range of reference standards in milk protein and urea nitrogen levels can be applied as a noninvasive economical feeding guide to monitor the balance of protein and energy intake. Standard reference levels of 3.0% milk protein and 11-17 mg/dL milk urea nitrogen (MUN) were established. Level of milk protein below 3.0% is regarded as indicating inadequate dietary energy whereas MUN below or above the range is regarded as a deficiency or surplus in dietary protein. Results from analysis of bulk a milk samples collected from 174 dairy herds over Taiwan showed that only one quarter (25.29%) of the herds received a balanced intake of protein and energy, 33.33% adequate protein with energy inadequate, 22.99% herds in protein surplus with energy inadequate, 10.35% herds in protein surplus with energy adequate, 4.6% protein deficiency with energy adequate, and 3.45% herds with both protein and energy inadequate. Energy inadequate herds accounted for 60% of the total dairy herds in Taiwan with 56% adequate, 38% surplus and 6% inadequate in protein. In comparing milk sampled from bulk milk on different seasons from Lee-Kang area in the southern Taiwan, the concentrations of milk fat and milk protein were significantly higher in the cool season (February) than in the warm season (August) (p<0.05), whereas the urea nitrogen in the milk was significantly lower in the cool season than in the warm season (p<0.05). This indicated that lactating cows had excess protein and/or inadequate energy intake in the warm season in this area. It appears that the major problem feeding in lactating cows is energy intake shortage, especially during the warm season in Taiwan.

Evaluation on Mechanical Properties of Polymer-Modified Warm-Mix Asphalt Mixtures for Monsoon Climate Regions (몬순기후형 중온 개질 아스팔트 혼합물의 역학적 물성 평가 연구)

  • Lee, Kanghun
    • International Journal of Highway Engineering
    • /
    • v.19 no.5
    • /
    • pp.131-141
    • /
    • 2017
  • PURPOSES : The main distress of asphalt pavements in monsoon climate regions are caused by water damage and plastic deformation due to repeated rain season and increased heavy vehicle traffic volume. In this study, the mechanical properties of polymer-modified warm mix asphalt (PWMA) materials are evaluated to use in monsoon climate regions such as Indonesia. METHODS : Comprehensive laboratory tests are conducted to evaluate moisture resistance and permanent deformation resistance for three different asphalt mixtures such as the Indonesian conventional hot-mix asphalt (HMA) mixture, the polymer-modified asphalt mixture, and the polymer-modified warm mix asphalt (PWMA) mixture. Dynamic immersion test and indirect tensile strength ratio test are performed to evaluate moisture resistance. The wheel tracking test is performed to evaluate rutting resistance. Additionally, the Hamburg wheel tracking test is performed to evaluate rutting and moisture resistances simultaneously. RESULTS :The dynamic immersion test results indicate that the PWMA mixture shows the highest resistance to moisture. The indirect tensile strength ratio test indicates that TSR values of PWMA mixture, Indonesian PMA mixture, and Indonesian HMA mixture show 87.2%, 84.1%, and 67.9%, respectively. The wheel tracking test results indicate that the PWMA mixture is found to be more resistant to plastic deformation than the Indonesian PMA. The dynamic stability values are 2,739 times/mm and 3,150 times/mm, respectively. Moreover, the Hamburg wheel tracking test results indicate that PWMA mixture is more resistant to plastic deformation than Indonesian PMA and HMA mixtures. CONCLUSIONS :Based on limited laboratory test results, it is concluded that rutting resistance and moisture susceptibility of the PWMA mixture is superior to Indonesian HMA and Indonesian PMA mixtures. It is postulated that PWMA mixture would be suitable for climate and traffic conditions in Indonesia.

The Effects of Atmospheric River Landfalls on Precipitation and Temperature in Korea (Atmospheric River 상륙이 한반도 강수와 기온에 미치는 영향 연구)

  • Moon, Hyejin;Kim, Jinwon;Guan, Bin;Waliser, Duane E.;Choi, Juntae;Goo, Tae-Young;Kim, Youngmi;Byun, Young-Hwa
    • Atmosphere
    • /
    • v.29 no.4
    • /
    • pp.343-353
    • /
    • 2019
  • The seasonal climatology of atmospheric rivers (ARs) and their effects on the seasonal precipitation and temperature in Korea are examined using the AR chronology obtained by a methodology based on the vertically integrated water vapor transport (IVT) in conjunction with a fine-scale gridded analysis of station precipitation and temperature. ARs are found to affect Korea most heavily in the warm season with minimal impacts in winter. This contrasts the AR effects in the western North America and the Western Europe that are affected most in winters. Significant portions of precipitation in Korea are associated with AR landfalls for all seasons; over 35% (25%) of the summer (winter) rainfall in the southern part of the Korean peninsula. The percentage of AR precipitation over Korea decreases rapidly towards the north. AR landfalls are also associated with heavier-than-normal precipitation events for all seasons. AR landfalls are associated with above-normal temperatures in Korea; the warm anomalies increase towards the north. The warm anomalies during AR landfalls are primarily related to the reduction in cold episodes as the AR landfalls in Korea are accompanied by anomalous southerlies/southwesterlies.

A Study on Experiments the Environmental Conditions and the Adaptation of the Human Body in the Vinyl House (Vinyl House 내의 환경조건과 인체적응에 관한 실험연구)

  • Shim, Bu-Ja
    • Journal of Preventive Medicine and Public Health
    • /
    • v.27 no.1 s.45
    • /
    • pp.59-73
    • /
    • 1994
  • The purpose of this study is to experiments the environmental conditions and the adaption of the human body in the vinyl house. The study was done in spring and winter and experimental clothes were used working clothes in the vinyl house. The results are as follows. 1. Environmental Conditions In the spring season, the indoor air temperature was $27.4{\pm}3.7^{\circ}C$ and the outdoor air temperature was $14.4{\pm}2.7^{\circ}C$. In the winter season, the indoor air temperature was $18.3{\pm}4.8^{\circ}C$ and the outdoor air temperature was $7.6{\pm}2.5^{\circ}C$ on the average. 2. Skin Temperature In the spring season, the mean skin temperatures indoor and outdoor were $33.81{\pm}0.7^{\circ}C\;and\;31.57{\pm}0.8^{\circ}C$ respectively, a difference of $2.24^{\circ}C$. In the winter season, they were $31.95{\pm}1.93^{\circ}C\;and\;29.86{\pm}0.55^{\circ}C$ respectively, a difference of $2.09^{\circ}C$. 3. Clothing Climate In the spring season, the temperature and humidity in the inner layer of clothing were $34.77{\pm}0.80^{\circ}C\;and\;70.75{\pm}1.65%$ indoor, $31.9{\pm}0.52^{\circ}C\;and\;51.9{\pm}3.70%$ outdoor respectively. In the winter season, those were $32.52{\pm}1.04^{\circ}C\;and\;64.65{\pm}3.68%$ indoor, $30.27{\pm}0.96^{\circ}C\;and\;45.07{\pm}2.68%$ outdoor respectively. 4. Physiological Factors Body temperature increased slightly and the pulse rate also rises, but blood pressure decreased a little with the rise of environmental temperature both in the spring and winter seasons. 5. Psychological Factors Thermal sensation in the spring season was expressed as 'slightly warm' or 'warm' indoor and as 'neutral' in the open air, while in the winter it was expressed as 'neutral' or 'slightly warm' outdoor the house and as 'cold' in the open air. Comfort sensation was characterized as 'uncomfortable' or 'slightly uncomfortable' indoor both in the spring and winter seasons, but in the open air it was characterized as 'comfortable' in the spring and as 'slightly uncomfortable' in the winter.

  • PDF

Estimation of Energy Use in Residential and Commercial Sectors Attributable to Future Climate Change (미래 기후변화에 따른 가정 및 상업 부문 에너지수요 변화 추정)

  • Jeong, Jee-Hoon;Kim, Joo-Hong;Kim, Baek-Min;Kim, Jae-Jin;Yoo, Jin-Ho;Oh, Jong-Ryul
    • Atmosphere
    • /
    • v.24 no.4
    • /
    • pp.515-522
    • /
    • 2014
  • In this study it is attempted to estimate the possible change in energy use for residential and commercial sector in Korea under a future climate change senario. Based on the national energy use and observed temperature data during the period 1991~2010, the optimal base temperature for determining heating and cooling degree days (HDD and CDD) is calculated. Then, net changes in fossil fuel and electricity uses that are statistically linked with a temperature variation are quantified through regression analyses of HDD and CDD against the energy use. Finally, the future projection of energy use is estimated by applying the regression model and future temperature projections by the CMIP5 results under the RCP8.5 scenario. The results indicate that, overall, the net annual energy use will decrease mostly due to a large decrease in the fossil fuel use for heating. However, a clear seasonal contrast in energy use is anticipated in the electricity use; there will be an increase in a warm-season demand for cooling but a decrease in a cold-season demand for heating.