• Title/Summary/Keyword: Walls

Search Result 4,321, Processing Time 0.027 seconds

Seismic response of geosynthetic reinforced retaining walls

  • Jesmani, Mehrab;Kamalzare, Mehrad;Sarbandi, Babak Bahrami
    • Geomechanics and Engineering
    • /
    • v.10 no.5
    • /
    • pp.635-655
    • /
    • 2016
  • The effects of reinforcement on the horizontal and vertical deformations of geosynthetic reinforced retaining walls are investigated under a well-known seismic load (San Jose earthquake, 1955). Retaining walls are designed with internal and external stability (with appropriate factor of safety) and deformation is chosen as the main parameter for describing the wall behavior under seismic load. Retaining walls with various heights (6, 8, 10, 12 and 14 meter) are optimized for geosynthetics arrangement, and modeled with a finite element method. The stress-strain behavior of the walls under a well-known loading type, which has been used by many previous researchers, is investigated. A comparison is made between the reinforced and non-reinforced systems to evaluate the effect of reinforcement on decreasing the deformation of the retaining walls. The results show that the reinforcement system significantly controls the deformation of the top and middle of the retaining walls, which are the critical points under dynamic loading. It is shown that the optimized reinforcement system in retaining walls under the studied seismic loading could decrease horizontal and vertical deformation up to 90% and 40% respectively.

A Study on the Wall Plants for the Improvement of the Urban Environment -With Special References to Seoul- (도시의 벽면녹화를 위한 벽면식생 조사연구 -서울시를 중심으로-)

  • 이숙미;심우경
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.22 no.1
    • /
    • pp.121-134
    • /
    • 1994
  • This study was surveyed the vegetation on the 2∼3 walls at 22 districts in Seoul to get basic data for wall planting in urban environment. The results were as follows: 1. 45 families, 90 genera and 113 species were grown on the walls in Seoul and woody wall plants were 30 species(26.5%) and herbaceous plants were 83 species(73.5%). 2. Of 30 woody species, evergreen species were 7(23.3%) and deciduous species were 23(76.7%). 3. Of 83 herbaceous species, annuals were 43(51.8%), biennials 12(14.5%), and perennials 28(33.7%). 4. Climbing wall plants were 28 species(24.8%). 5. 35 species(31.0%) were planted artificially and 78 species(69.0%) were self-grown plants. 6. Of 138 planted walls, 46 walls were covered with Parthenocissus tricuspidata(33.3%), 11 walls Forsythia koreana(8.0%), 9 walls Pharbitis nil(6.5%), 9 walls Wisteria floribunda(6.5%), and 8 walls Rosa multiflora var. platyphlla(5.8%). 7. In the comparison of native and exotic plants on the walls in Seoul, native species were 84(74.3%) and exotic were 29(25.7%).

  • PDF

Retrofitting of squat masonry walls by FRP grids bonded by cement-based mortar

  • Popa, Viorel;Pascu, Radu;Papurcu, Andrei;Albota, Emil
    • Earthquakes and Structures
    • /
    • v.10 no.1
    • /
    • pp.125-139
    • /
    • 2016
  • For seismic retrofitting of masonry walls, the use of fibre reinforced cement-based mortar for bonding the fibre grids can eliminate some of the shortcomings related to the use of resin as bonding material. The results of an experimental testing program on masonry walls retrofitted with fibre reinforced mortar and fibre grids are presented in this paper. Seven squat masonry walls were tested under unidirectional lateral displacement reversals and constant axial load. Steel anchors were used to increase the effectiveness of the bond between the fibre grids and the masonry walls. Application of fibre grids on both lateral faces of the walls effectively improved the hysteretic behaviour and specimens could be loaded until slip occurred in the horizontal joint between the masonry and the bottom concrete stub. Application of the fibre grids on a single face did not effectively improve the hysteretic behaviour. Retrofitting with fibre reinforced mortar only prevented the early damage but did not effectively increase deformation capacity. When the boundaries of the cross sections were not properly confined, midplane splitting of the masonry walls occurred. Steel anchors embedded in the walls in the corners area effectively prevented this type of failure.

Influence of strong ground motion duration on reinforced concrete walls

  • Flores, Camilo;Bazaez, Ramiro;Lopez, Alvaro
    • Earthquakes and Structures
    • /
    • v.21 no.5
    • /
    • pp.477-487
    • /
    • 2021
  • This study focuses on the influence of strong ground motion duration on the response and collapse probability of reinforced concrete walls with a predominant response in flexure. Walls with different height and mass were used to account for a broad spectrum of configurations and fundamental periods. The walls were designed following the specifications of the Chilean design code. Non-linear models of the reinforced concrete walls using a distributed plasticity approach were performed in OpenSees and calibrated with experimental data. Special attention was put on modeling strength and stiffness degradation. The effect of duration was isolated using spectrally equivalent ground motions of long and short duration. In order to assess the behavior of the RC shear walls, incremental dynamic analyses (IDA) were performed, and fragility curves were obtained using cumulative and non-cumulative engineering demand parameters. The spectral acceleration at the fundamental period of the wall was used as the intensity measure (IM) for the IDAs. The results show that the long duration ground motion set decreases the average collapse capacity in walls of medium and long periods compared to the results using the short duration set. Also, it was found that a lower median intensity is required to achieve moderate damage states in the same medium and long period wall models. Finally, strength and stiffness degradation are important modelling parameters and if they are not included, the damage in reinforced concrete walls may be greatly underestimated.

The effect of mortar type and joint thickness on mechanical properties of conventional masonry walls

  • Zengin, Basak;Toydemir, Burak;Ulukaya, Serhan;Oktay, Didem;Yuzer, Nabi;Kocak, Ali
    • Structural Engineering and Mechanics
    • /
    • v.67 no.6
    • /
    • pp.579-585
    • /
    • 2018
  • Masonry walls are of a complex (anisotropic) structure in terms of their mechanical properties. The mechanical properties of the walls are affected by the properties of the materials used in wall construction, joint thickness and the type of masonry bond. The carried-out studies, particularly in the seismic zones, have revealed that the most of the conventional masonry walls were constructed without considering any engineering approach. Along with that, large-scale damages were detected on such structural elements after major earthquake(s), and such damages were commonly occurred at the brick-joint interfaces. The aim of this study was to investigate the effect of joint thickness and also type of mortar on the mechanical behavior of the masonry walls. For this aim, the brick masonry walls were constructed through examination of both the literature and the conventional masonry walls. In the construction process, a single-type of brick was combined with two different types of mortar: cement mortar and hydraulic lime mortar. Three different joint thicknesses were used for each mortar type; thus, a total of six masonry walls were constructed in the laboratory. The mechanical properties of brick and mortars, and also of the constructed walls were determined. As a conclusion, it can be stated that the failure mechanism of the brick masonry walls differed due to the mechanical properties of the mortars. The use of bed joint thickness not less than 20 mm is recommended in construction of conventional masonry walls in order to maintain the act of brick in conjunction with mortar under load.

Characteristics of Walls Supported by Prefabricated Strut (조립식 버팀보로 지지된 흙막이 구조물의 거동 특성에 관한 연구)

  • 김낙경;박종식
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2003.03a
    • /
    • pp.553-560
    • /
    • 2003
  • From the analytical standpoint, it is advantageous to consider the behavior of supported walls as plane strain condition. But supported walls constitute geotechnical problems which, in strut terms, are not plane strain cases. These represent differences between the measured and the predicted due to the stiffness and spacing of supported walls and the behavior of discontinuous walls such as solider beams with lagging. This study is to investigate simulations of a system behavior along a horizontal section of walls supported by prefabricated strut. Using a beam column method, relative effects associated with prefabricated strut stiffness and spacing in a systematic behavior were investigated.

  • PDF

Experimental study on cyclic behavior of reinforced concrete parallel redundancy walls

  • Lua, Yiqiu;Huang, Liang
    • Structural Engineering and Mechanics
    • /
    • v.52 no.6
    • /
    • pp.1177-1191
    • /
    • 2014
  • Reinforced concrete (RC) shear walls are one of the most commonly used lateral-load resisting systems in high-rise buildings. RC Parallel redundancy walls studied herein consist of two parts nested to each other. These two parts have different mechanical behaviors and energy dissipation mechanisms. In this paper, experimental studies of four 1/2-scale specimens representing this concept, which are subjected to in-plane cyclic loading, are presented and test results are discussed. Two specimens consist of a wall frame with barbell-shaped walls embedded in it, and the other two consist of a wall frame and braced walls nested each other. The research mainly focuses on the failure mechanism, strength, hysteresis loop, energy dissipation capacity and stiffness of these walls. Results show that the RC parallel redundancy wall is an efficient lateral load resisting component that acts as a "dual" system with good ductility and energy dissipation capacity. One main part absorbs a greater degree of the energy exerted by an earthquake and fails first, whereas the other part can still behave as an independent role in bearing loads after earthquakes.

Stochastic response analysis of visco-elastic slit shear walls

  • Kwan, A.K.H.;Tian, Q.L.;Cheung, Y.K.
    • Structural Engineering and Mechanics
    • /
    • v.6 no.4
    • /
    • pp.377-394
    • /
    • 1998
  • Slit shear walls an reinforced concrete shear wall structures with purposely built-in vertical slits. If the slits are inserted with visco-elastic damping materials, the shear walls will become viscoelastic sandwich beams. When adequately designed, this kind of structures can be quite effective in resisting earthquake loads. Herein, a simple analysis method is developed for the evaluation of the stochastic responses of visco-elastic slit shear walls. In the proposed method, the stiffness and mass matrices are derived by using Rayleigh-Ritz method, and the responses of the structures are calculated by means of complex modal analysis. Apart from slit shear walls, this analysis method is also applicable to coupled shear walls and cantilevered sandwich beams. Numerical examples are presented and the results clearly show that the seismic responses of shear wall structures can be substantially reduced by incorporating vertical slits into the walls and inserting visco-elastic damping materials into the slits.

A Study on Cooling Systems with Cold Water Panels in the Walls of Small Buildings (소형 건축 벽면의 냉수 패널에 의한 냉방시스템에 관한 연구)

  • Cho, Dong-Hyun;Jo, Myeong-Gi
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.18 no.10
    • /
    • pp.20-26
    • /
    • 2019
  • This study was conducted on cooling systems in which, for the first time at home and abroad, cold water panels are embedded in the walls of small buildings for radiant cooling by heat absorption with cold water. In summer, cold water is circulated through cold water (chiller) circulation tubes embedded in three walls (two side walls and one rear wall) of a building to implement radiant cooling by the coldness of the water. From the results of this study, the experimental and theoretical natural convection heat transfer coefficients were relatively well-matched over the entire experimental range, thereby verifying the reliability of the experimental results. The surface temperature reduction rate of the walls in which cold water panels are embedded was large whereas that of the walls where no cold water panels are embedded was very small.

A Study on Bang Walls in the Capital of Silla - With a focus on the Hwangnyongsa Temple and its surroundings - (신라왕경 방장(坊牆)에 관한 연구 - 황룡사 및 그 주변을 중심으로 -)

  • Hyun, Seung-Wook
    • Journal of architectural history
    • /
    • v.30 no.1
    • /
    • pp.7-17
    • /
    • 2021
  • Bang walls surround the four sides of Band in ancient capital cities of East Asia where the Bang system was in operation. There are ongoing research efforts for the structure of a capital city and Bang system around the capital of Silla, but there is a huge shortage of research on Bang walls. This study thus set out to examine Bang walls in the capital of Silla around the Hwangnyongsa Temple and its surroundings. The findings show that the Bang walls in the capital of Silla were built with a mix of earth and stone and with tiled roofs on top. The sizes of Bang walls were distinguished from the walls of individual structure groups inside Bang and closely related to the Bang size and the width of adjacent roads.