• 제목/요약/키워드: Wallis

검색결과 806건 처리시간 0.039초

접착제 도포후 오염된 표면의 처리방법에 따른 복합레진의 전단결합강도와 미세누출 (SHEAR BOND STRENGTH AND MICROLEAKAGE OF COMPOSITE RESIN ACCORDING TO TREATMENT METHODS OF CONTAMINATED SURFACE AFTER APPLYING A BONDING AGENT)

  • 박주식;이석종;문주훈;조영곤
    • Restorative Dentistry and Endodontics
    • /
    • 제24권4호
    • /
    • pp.647-656
    • /
    • 1999
  • The purpose of this study was to investigate the shear bond strength and marginal microleakage of composite to enamel and dentin according to different treatment methods when the applied bonding agent was contaminated by artificial saliva. For the shear bond strength test, the buccal and occlusal surfaces of one hundred twenty molar teeth were ground to expose enamel(n=60) and dentin surfaces(n=60). The specimens were randomly assigned into control and 5 experimental groups with 10 samples in each group. In control group, a bonding system(Scotchbond$^{TM}$ Multi-Purpose plus) and a composite resin(Z-100$^{TM}$) was bonded on the specimens according to manufacture's directions. Experimental groups were subdivided into 5 groups. After polymerization of an adhesive, they were contaminated with at artificial saliva on enamel and dentin surfaces: Experimental group 1 ; artificial saliva was dried with compressed air. Experimental group 2 ; artificial saliva was rinsed with air-water spray and dried. Experimental group 3 ; artificial saliva was rinsed, dried and applied an adhesive. Experimental group 4 ; artificial saliva was rinsed, dried, and then etched using phosphoric acid followed by an adhesive. Experimental group 5, artificial saliva was rinsed, dried, and then etched with phosphoric acid followed by consecutive application of both a primer and an adhesive. Composite resin(Z-100$^{TM}$) was bonded on saliva-treated enamel and dentin surfaces. The shear bond strengths were measured by universal testing machine(AGS-1000 4D, Shimaduzu Co. Japan) with a crosshead speed of 5mm/minute under 50kg load cell. Failure modes of fracture sites were examined under stereomicroscope. The data were analyzed by one-way ANOVA and Tukey's test. For the marginal microleakage test, Class V cavities were prepared on the buccal surfaces of sixty molars. The specimens were divided into control and experimental groups. Cavities in experimental group were contaminated with artificial saliva and those surfaces in each experimental groups received the same treatments as for the shear test. Cavities were filled with Z-100. Specimens were immersed in 0.5% basic fuchsin dye for 24 hours and embedded in transparent acrylic resin and sectioned buccolingually with diamond wheel saw. Four sections were obtained from the one specimen. Marginal microleakages of enamel and dentin were scored under streomicroscope and averaged from four sections. The data were analyzed by Kruskal-Wallis test and Fisher's LSD. The results of this study were as follows. 1. The shear bond strength to enamel showed lower value in experimental group 1(13.20${\pm}$2.94MPa) and experimental group 2(13.20${\pm}$2.94MPa) than in control(20.03${\pm}$4.47MPa), experimental group 4(20.96${\pm}$4.25MPa) and experimental group 5(21.25${\pm}$4.48MPa) (p<0.05). 2. The shear bond strength to dentin showed lower value in experimental group 1(9.35${\pm}$4.11MPa) and experimental group 2(9.83${\pm}$4.11MPa) than in control group(17.86${\pm}$4.03MPa), experimental group 4(15.04${\pm}$3.22MPa) and experimental group 5(14.33${\pm}$3.00MPa) (p<0.05). 3. Both on enamel and dentin surfaces, experimental group 1 and 2 showed many adhesive failures, but control and experimental group 3, 4 and 5 showed mixed and cohesive failures. 4. Enamel marginal microleakage was the highest in experimental group 1 and there was a significant difference in comparison with other groups (p<0.05). 5. Dentin marginal microleakages of experimental group 1 and 2 were higher than those of other groups (p<0.05). This result suggests that treatment methods, re-etching with 35% phosphoric acid followed by re-application of adhesive or repeating all adhesive procedures, will produce good effect on both shear bond strength and microleakage of composite to enamel and dentin if the polymerized bonding agent was contaminated by saliva.

  • PDF

유동성 복합 레진을 적용한 예방적 레진 수복물의 미세 누출 양상에 관한 비교 연구 (A COMPARATIVE STUDY ON THE MICROLEAKAGE OF PRVENTIVE RESIN RESTORATION USING FLOWABLE COMPOSITE RESIN)

  • 박헌정;김종수;김용기
    • 대한소아치과학회지
    • /
    • 제27권3호
    • /
    • pp.419-430
    • /
    • 2000
  • 성인에 비해 치료를 견별 수 있는 시간이 상대적으로 짧은 소아 환자에 있어 시술 시간은 치료 결과의 중요한 변수로 작용하게 된다. 최근 소개된 유동성 복합 레진을 예방적 레진 수복술에 사용하게 될 경우 전색재 도포 과정을 생략할 수 있어 시술 시간의 단축 편의성 등의 장점이 인정되나 미세누출 등에 관한 연구 결과는 미흡한 실정이다. 본 연구의 목적은 최근 소개된 유동성 복합 레진을 사용한 예방적 레진 수복물과 기존의 복합 레진과 전색재를 사용한 예방적 레진 수복물 간의 미세누출 및 기포발생 정도를 비교하고자 함이었다. 교합면이 건전한 상악 소구치 60개를 대상으로 고속용 1/2 round bur를 이용하여 교합면 열구를 따라 길이$3.0\times$$0.7\times$깊이2.0mm의 I급 와동을 형성하고 각 군 당 20개씩 무작위로 시편을 배분하고, 제조자의 지침에 따라 본딩재인 Scotchbond $Multipurpose^{TM}$(3M dental product, U.S.A.)를 적용하고 유동성 복합 레진 수복군인 I, II군에는 각각 $Revolution^{TM}$(Kerr, U.S.A.)과 Arabesk Flow(VOCO, Germany), 대조군인 III군(통상적 예방적 레진 수복군)에는 Restorative $Z-100^{TM}$(3M dental product, U.S.A.)과 $Concise^{TM}$(3M dental product, U.S.A.)를 제조자의 지시에 따라 충전, 적용하였다. 3,000회의 열 순환 및 색소 침투 후 시편을 절단하여 컴퓨터에 영상을 입력하고 색소의 침투 길이 및 침투 비율을 계산하고 미세누출 평가 기준을 이용하여 각 시편에 대한 미세누출 정도를 평가하였다. 또한, 각 군별로 특징적으로 나타난 기포의 발생 양상을 별도의 평가기준에 따라 평가하였다. 미세누출은 수복재와 법랑질의 계면부에 국한되어 관찰되었고, 와동 내부까지 침투된 경우는 없었으며, 유동성 복합레진 수복군(I, II군)이 기존의 예방적 레진 수복군(III군)에 비해 낮은 미세 누출 정도를 나타냈다(p<0.05). 미세누출 결과 외에, 대부분의 충전물 내에서 다양한 형태의 기포가 발견되었으며, I, II군 표본에서 III군에 비해 크기가 큰 기포가 더욱 많이 관찰되었다.

  • PDF

강릉시 노인의 임상지표를 이용한 OHIP 14 (Oral Health Impact Profile 14)의 타당도 연구 (The Study on the Validity of the OHIP 14 (Oral Health Impact Profile 14) Using Health Index on Elderly Population, Gangneung City)

  • 이지연
    • 치위생과학회지
    • /
    • 제9권4호
    • /
    • pp.475-483
    • /
    • 2009
  • 한국 노인을 대상으로 외국에서 비교적 높은 신뢰도와 타당도가 입증된 Oral Health Impact Profile 14(OHIP 14)를 한국의 문화적 특성이나 사고방식에 맞게 번역하여 강릉시에 거주하는 노인 만 65세 이상 668명을 대상으로 2005년 1월부터 2월까지 2개월간 OHIP 14 지표의 신뢰도와 타당도를 검증(Kappa index, Cronbach's alpha Correlation & Spearman ranked correlation coefficient)하고, OHIP 14와(구강)건강인식도, 구강건강상태, 전신건강 상태와의 차이를 검증(Kruskal Wallis test, Mann-Whitney U-test)함으로써, 향후 우리나라 노인 구강건강문제를 포괄적으로 파악하기 위한 지표로 활용할 수 있는 지를 검토하고자 하였다. 1. (구강)건강인식도와 OHIP 14는 전신건강인식도, 구강건강인식도, 치과치료필요도, 구강건강만족도, 통증에 대한 시각적 정도, 틀니만족도, 구강건강상태와 OHIP 14는 무치악 여부, 현존 자연치아의 개수, 치아치료필요, 전신건강상태와 OHIP 14는 질병의 개수, 치매, 눈, 귀, 호흡기, 심혈관, 소화기, 비뇨생식기, 근골격계, 신경계, 심리상태가 상관관계가 있는 것으로 나타났다. 2. (구강)건강인식도에 따른 OHIP 14는 전신건강인식도, 구강건강인식도, 치과치료필요도, 구강건강만족도, 통증에 대한 시각적 정도, 틀니만족도, 구강건강상태에 따른 OHIP 14는 무치악 여부, 치아치료필요, 현존 자연치아의 개수, 전신건강상태에 따른 OHIP 14는 치매, 귀, 호흡기, 심혈관, 소화기, 근골격계, 신경계, 심리상태에서 현저한 차이를 보였다. 본 연구는 일부 노인에서 임상지표를 이용한 OHIP 14에서 (구강)건강인식도, 구강건강상태, 전신건강상태가 OHIP 14와의 타당도와 연관성이 있다는 사실을 일부에서 확인할 수 있었다. 이상의 결과로 향후 한국노인의 구강건강문제를 포괄적으로 파악하는데 전통적인 구강건강 상태검사, 전신건강상태검사와 더불어 '구강건강 관련 삶의 질' 지표인 OHIP 14를 활용할 수 있을 것으로 사료된다.

  • PDF

골유착 재현 레진 모델에서 골 상태 및 임플란트 형태에 따른 임플란트 안정성에 관한 연구 (Implant stability evaluation according to the bone condition, fixture diameter and shape in the osseointegration simulated resin model)

  • 권택가;여인성;김성훈;한중석;이재봉;양재호
    • 대한치과보철학회지
    • /
    • 제49권2호
    • /
    • pp.128-137
    • /
    • 2011
  • 연구 목적: 자기공명주파수 분석, 페리오테스트, 풀림 토크는 임플란트의 안정성을 측정하기 위한 방법으로 알려져 있다. 이 방법들은 골 상태와 임플란트 형태에 영향을 받는다. 본 연구에서는 골유착이 재현된 아크릴 레진 실험 모델에서 임플란트가 결합된 골의 양을 변화하고 경부의 골 상실양이 증가하였을 경우, 자기공명주파수 분석, 페리오테스트, 풀림 토크 측정에 어떠한 영향을 주는지 알아보고 이들 상호간의 관계를 알아보고자 하였다. 연구 재료 및 방법: 골 유착을 재현하기 위하여 임플란트를 알루미늄 틀에 나사로 고정한 후 자가중합형 아크릴릭 레진의 가루와 용액을 틀 안에 부어서 중합을 시켰다. 임플란트와 결합된 레진의 두께를 조정하여 골 결합 두께를 각각 1, 3, 5, 10 mm인 경우로 재현하였다. 그 후 임플란트 주변 경부 골 상실 양이 1, 3, 5 mm인 경우를 재현하였다. 각각의 재현된 골 조건에서는 4 mm 직경의 직선형 임플란트, 같은 직경의 tapered 형 임플란트, 5 mm 직경의 tapered 형의 3가지 임플란트가 각각 5개씩 사용되었다. 모든 골 조건에서 자기공명주파수 분석과 페리오테스트 측정이 이루어졌으며 골 결합 두께 1, 3 mm 시편에서는 풀림 토크가 측정되었다. 결과: 골 결합 두께가 증가하거나 임플란트 직경이 증가할수록 통계적으로 유의하게 ISQ 값은 증가하였고, 페리오테스트 값은 감소하였다 (P<.001, P<.001). 임플란트 경부에 주위 골 상실 양이 커질수록 ISQ 값은 감소하였고, 페리오테스트 값은 증가하였다 (P<.001). ISQ 값과 페리오테스트 t값은 매우 강한 상관관계를 나타냈다 (r = -0.99, P<.001). ISQ값과 풀림토크는 약한 상관관계를 나타냈으며 (r = 0.52, P<.001), 페리오테스트 값과 풀림 토크도 약한 상관관계를 나타냈다 (r = -0.52, P<.001). 결론: 레진으로 재현한 골의 양이 증가할수록, 임플란트의 직경이 증가할수록, 경부의 골 상실양이 적을수록 임플란트 안정성이 증가함을 확인할 수 있었다. 또한 본 연구에서는 ISQ 값과 페리오테스트 값의 강한 상관관계를 밝힐 수 있었다.

모션 데이터를 이용한 3차원 아바타 얼굴 표정 제어 (Facial Expression Control of 3D Avatar using Motion Data)

  • 김성호;정문렬
    • 정보처리학회논문지A
    • /
    • 제11A권5호
    • /
    • pp.383-390
    • /
    • 2004
  • 본 논문은 사용자로 하여금 얼굴표정들의 공간으로부터 일련의 표정을 실시간 적으로 선택하게 함으로써 3차원 아바타의 얼굴 표정을 제어하는 기법을 제안하고, 해당 시스템을 구축한다. 본 시스템에서는 얼굴 모션 캡쳐 데이터로 구성된 2400여개의 표정 프레임을 이용하여 표정공간을 구성하였다. 본 기법에서는 한 표정을 표시하는 상태표현으로 얼굴특징 점들 간의 상호거리를 표시하는 거리행렬을 사용한다. 이 거리행렬의 집합을 표정공간으로 한다. 그러나 이 표정공간은 한 표정에서 다른 표정까지 이동할 때 두 표정간의 직선경로를 통해 이동할 수 있는 그런 공간이 아니다. 본 기법에서는 이 경로를 표정 데이터로부터 근사적으로 유추한다. 우선, 각 표정상태를 표현하는 거리행렬간의 거리가 일정 값 이하인 경우 두 표정을 인접해 있다고 간주한다. 임의의 두 표정 상태가 일련의 인접표정들의 집합으로 연결되어 있으면 두 표정간에 경로가 존재한다고 간주한다. 한 표정에서 다른 표정으로 변화할 때 두 표정간의 최단경로를 통해 이동한다고 가정한다. 두 표정간의 최단거리를 구하기 위해 다이내믹 프로그래밍 기법을 이용한다. 이 거리행렬의 집합인 표정공간은 다차원 공간이다. 3차원 아바타의 얼굴 표정은 사용자가 표정공간을 항해하면서 원하는 표정을 실시간 적으로 선택함으로써 제어한다. 이를 도와주기 위해 표정공간을 다차원 스케일링 기법을 이용하여 2차원 공간으로 가시화 했다. 본 시스템이 어떤 효과가 있는지를 알기 위해 사용자들로 하여금 본 시스템을 사용하여 3차원 아바타의 얼굴 표정을 제어하게 해본 결과, 3차원 아바타의 실시간 얼굴 표정 제어가 필요한 각 분야에서 매우 유용하게 사용될 것으로 판단되었다.24시간 경과시킨 후 치아의 장축에 따라 절단하여 침투된 색소의 정도를 광학현미경상에서 40배로 관찰하였다. 각각의 실험결과는 ANOVA/Tukey's test 및 Kruskal-Wallis non-parametric independent analysis와 Mann-Whitney U test에 의하여 통계 분석하여 다음과 같은 결론을 얻었다. 1. 대조군에 있어서 혼합형 복합레진의 미세인장 결합강도는 미세혼합형에 비하여 높았으며, 실험군 사이에는 유의차를 보이지 않았다. 2.모든 복합레진의 미세인장 결합강도는 와동의 C-factor증가에 따라 감소하는 경향을 나타내었고, 혼합형 복합레진의 실험군은 대조군에 비하여 낮게 나타났으며, 미세혼합형 복합레진에서는 유의차를 보이지 않았다. 3. 절단측 및 치은측 변연부의 미세누출정도는 혼합형 복합레진이 미세혼합형에 비하여 대체로 높게 나타났다. 4. 모든 실험군에서 미세누출은 C-factor증가에 따라 증가하였고 절단측에 비하여 치은측 변연이 높게 나타났으나 통계학적 유의차는 보이지 않았다. C-factor의 변화에 대하여 필러함량과 탄성계수가 높은 혼합형 복합레진이 미세혼합형에 비하여 더 민감한 결과를 보인다. 이는 복합레진 수복시 재료의 선택과 중합수축의 적절한 조절이 중요한 요소임을 시사한다.s에서는 1주, 2주에서 강한 염증반응을 보였으나 12주에서는 염증반응이 감소하였다. 4) 새로 개발된 봉함제 Adseal-1,2는 1주, 2주에서는 가장 약한 염증반응을 보이나 4주, 12주 후에는 AH Plus와 비슷한 수준의 염증 반응을 보였다. 5) Pulp Canal Sealer를 제외한 모든 군에서 인정할 만한 생체친화성을 보였다. 6)

접착강화제 도포후 인공타액에 오염된 표면의 처리방법에 따른 복합레진의 번연누출과 전단결합강도 (MARGINAL MICROLEAKAGE AND SHEAR BOND STRENGTH OF COMPOSITE RESIN ACCORDING TO TREATMENT METHODS OF ARTIFICIAL SALIVA-CONTAMINATED SURFACE AFTER PRIMING)

  • 조영곤;고기종;이석종
    • Restorative Dentistry and Endodontics
    • /
    • 제25권1호
    • /
    • pp.46-55
    • /
    • 2000
  • During bonding procedure of composite resin, the prepared cavity can be contaminated by saliva. In this study, marginal microleakage and shear bond strength of a composite resin to primed enamel and dentin treated with artificial saliva(Taliva$^{(R)}$) were evaluated. For the marginal microleakage test, Class V cavities were prepared in the buccal surfaces of fifty molars. The samples were randomly assigned into 5 groups with 10 samples in each group. Control group was applied with a bonding system (Scotchbond$^{TM}$ Multi-Purpose plus) according to manufacture's directions without saliva contamination. Experimental groups were divided into 4 groups and contaminated with artificial saliva for 30 seconds after priming: Experimental 1 group ; artificial saliva was dried with compressed air only, Experimental 2 group ; artificial saliva was rinsed and dried. Experimental 3 group ; cavities were etched with 35% phosphoric acid for 15 seconds after rinsing and drying artificial saliva. Experimental 4 group ; cavities were etched with 35% phosphoric acid for 15 seconds and primer was reapplied after rinsing and drying artificial saliva. All the cavities were applied a bonding agent and filled with a composite resin (Z-100$^{TM}$). Specimens were immersed in 0.5% basic fuschin dye for 24 hours and embedded in transparent acrylic resin and sectioned buccolingually with diamond wheel saw. Four sections were obtained from one specimen. Degree of marginal leakage was scored under stereomicroscope and their scores were averaged from four sections. The data were analyzed by Kruscal-Wallis test and Fisher's LSD. For the shear bond strength test, the buccal or occlusal surfaces of one hundred molar teeth were ground to expose enamel(n=50) or dentin(n=50) using diamond wheel saw and its surface was smoothed with Lapping and Polishing Machine(South Bay Technology Co., U.S.A.). Samples were divided into 5 groups. Treatment of saliva-contaminated enamel and dentin surfaces was same as the marginal microleakage test and composite resin was bonded via a gelatin capsule. All specimens were stored in distilled water for 48 hours. The shear bond strengths were measured by universal testing machine (AGS-1000 4D, Shimaduzu Co., Japan) with a crosshead speed of 5 mm/minute. Failure mode of fracture sites was examined under stereomicroscope. The data were analyzed by ANOVA and Tukey's studentized range test. The results of this study were as follows : 1. Enamel marginal microleakage showed no significant difference among groups. 2. Dentinal marginal microleakages of control, experimental 2 and 4 groups were lower than those of experimental 1 and 3 groups (p<0.05). 3. The shear bond strength to enamel was the highest value in control group (20.03${\pm}$4.47MPa) and the lowest value in experimental 1 group (13.28${\pm}$6.52MPa). There were significant differences between experimental 1 group and other groups (p<0.05). 4. The shear bond strength to dentin was higher in control group (17.87${\pm}$4.02MPa) and experimental 4 group (16.38${\pm}$3.23MPa) than in other groups, its value was low in experimental 1 group (3.95${\pm}$2.51 MPa) and experimental 2 group (6.72${\pm}$2.26MPa)(p<0.05). 5. Failure mode of fractured site on the enamel showed mostly adhesive failures in experimental 1 and 3 groups. 6. Failure mode of fractured site on the dentin did not show adhesive failures in control group, but showed mostly adhesive failure in experimental groups. As a summary of above results, if the primed tooth surface was contaminated with artificial saliva, primer should be reapplied after re-etching it.

  • PDF

국내 기초·분석과학 분야 내 중국산 연구시설·장비 구축 현황에 따른 국산화 정책 제언 (Proposal of Localization Policy Based on the Status of Chinese's Research Facilities and Equipment Construction in Korean Basic and Analytical Science Field)

  • 김창용;정태원;공재현;박찬수
    • 한국산학기술학회논문지
    • /
    • 제20권6호
    • /
    • pp.460-471
    • /
    • 2019
  • 본 연구의 목적은 과거 14년간 한국 정부가 투자한 연구시설 장비의 구축정보를 기반으로 기초 분석과학 분야에서 중국산 연구시설 장비가 국내연구장비 시장에서 차지하는 규모와 시장점유의 수준을 알아보기 위해 구축년도 장비표준분류 보유기관 유형별로 구축 수와 구축금액 차이를 비교 분석하였다. 또한 구축년도 장비표준분류 보유기관 유형 변수들 간에 상관성 유무도 분석하였다. 2019년 1월 1일을 기준으로 2005년부터 2018년까지 국내에 구축된 중국산 연구시설 장비를 대상으로 기초 분석과학 분야에 활용되는 연구시설 장비(구축금액이 3천만원 이상인 주장비 기준) 50점의 구축 수, 구축금액, 구축년도, 연구장비 보유기관, 그리고 장비표준분류를 분석 항목에 포함하였다. 구축년도 장비표준분류 보유기관 유형 내 중국산 연구시설 장비 구축 수 차이를 비교하기 위하여 단일표본 카이제곱검정 방법을, 구축년도 장비표준분류 보유기관 유형별 중국산 연구시설 장비 구축금액 차이를 비교하기 위하여 각각 맨-휘트니 U 검정과 크러스칼-왈리스 검정을 사용하였으며 구축년도 장비표준분류 보유기관 유형 간 상관성 유무는 교차분석을 통한 카이제곱검정을 이용하였다. 본 연구결과, 중국산 연구장비의 국내 구축 수와 금액은 구축년도 장비표준분류 보유기관 유형별로 통계학적으로 유의하게 증가(p<.05).하는 추세이며 2000년대에 비해 2010년대에 고가의 광학전자/영상장비가 사립대학 및 민간기업과 정부출연연구소에 구축되었다. 따라서 기초 분석과학 분야 내 중국산 연구시설 장비의 국내 구축현황은 국산보다는 그 수준이 아직 미비하지만 구축 수와 금액이 통계학적으로 유의하게 증가 추세이므로 중국산 연구시설 장비가 국내 연구산업시장을 잠식할 수 있다는 가능성을 인지함과 동시에 관련 대비책 마련이 정부 주도로 필요할 것이다.

임플란트 bar 어태치먼트에 사용하는 두 가지 부가적인 유지장 치의 유지력 특성 비교 (Comparison of the retentive characteristics of two additional attachment used with an implant bar attachment)

  • 최재원;채성기;허중보
    • 대한치과보철학회지
    • /
    • 제59권2호
    • /
    • pp.173-180
    • /
    • 2021
  • 목적: 본 연구는 반복적인 착탈에 따른 임플란트 bar 어태치먼트에 사용하는 두 가지 부가적인 유지장치의 유지력 특성을 평가해보고자 하였다. 재료 및 방법: 본 연구에서는 새롭게 개발된 유지장치(ADD-Lock; AL)와 기존의 상용화된 유지장치(Locator blue; LB)의 두 가지 유지장치를 평가하였다. 두 개의 고정체를 하부 구조물에 평행하게 위치시키고, 각 유지장치의 patrix를 고정체에 연결하였다. 각 유지장치의 matrix는 대합되는 상부 구조물에 위치시키고 고정하였다. Universal testing machine을 이용하여 초기, 100, 250, 500, 1000, 2000, 2500회의 반복적인 착탈 동안에 각 유지장치의 유지력을 측정하였다. 유지장치의 마모 및 변형 정도는 주사전자현미경으로 관찰하였다. Kruskal-Wallis test, Mann-Whitney U test (α = .05), 그리고 wilcoxon signed-rank test (α = .05)를 이용하여 통계분석 실시하였다. 결과: 초기 유지력과 2500회의 반복적인 착탈 후 유지력에서, AL군(15.24 ± 1.46 N, 9.74 ± 1.16 N)은 LB군(43.53 ± 12.39 N, 22.99 ± 4.77 N)보다 유의하게 작은 값을 보였다(P < .05). 또한, 유지력 소실량에 있어서도 AL군(5.50 ± 1.08 N, 36.08%)이 LB군(20.54 ± 11.89 N, 47.19%)에 비해 낮은 값을 보였다(P < .05). 주사전자현미경 분석 결과, AL군은 patrix에서, LB군은 matrix에서 눈에 띄는 마모 및 변형이 관찰되었다. 결론: Locator는 새롭게 개발된 유지장치보다 높은 초기 유지력을 보인 반면 높은 유지력 소실량을 보였다. 한편, 두 가지 부가적인 유지장치는 반복적인 착탈 후에도 충분한 유지력을 가지는 것으로 나타났다.

K 대학교 치위생학과 학생의 해외임상실습참여가 임상실습만족도, 전공만족도 및 해외취업의사에 미치는 영향 (Effect of K University Dental Hygiene Department students' participation in overseas clinical practice on satisfaction with practice, major, and intention to work abroad)

  • 이민선;최마이
    • 대한치위생과학회지
    • /
    • 제6권2호
    • /
    • pp.151-160
    • /
    • 2023
  • 연구배경: 강원도 K 대학교 치위생학과 학생의 해외임상실습참여에 따른 임상실습만족도 및 전공만족도, 해외취업의사의 차이를 분석하고자 시행하였다. 연구방법: 치위생학과 3,4학년 편의추출하여 총 215명에게 설문조사를 실시하였으며, 불성실 응답 1부를 제외하고 최종 214부를 분석하였다. 일반적인 특성은 성별, 학년, 치과 아르바이트 경험, 부모님 합산 월소득, 해외여행 경험, 토익 응시 여부, 학교 성적을 조사하였다. 학과 만족도와 학교 성적은 5점 Likert 척도로 측정하였다. 임상실습 관련 만족도는 임상실습 만족도, 해외실습 참여 의향, 해외취업 관심도를 조사하였다. 임상실습 만족도, 해외실습 참여도, 해외취업 관심도는 '만족(참여)한다', '보통이다', '만족(참여)하지 않는다'로 재구분하여 분석하였다. 연구결과: 해외임상실습에 참여자의 임상실습 만족도는 5점 만점의 4.00±1.00, 미참여자는 3.75±1.02, 전공만족도는 참여자 3.57±0.93, 미참여자 3.48±0.80로 차이가 있었으나 통계적으로 유의한 차이가 없었다(p=.239, z=-1.177)(p=.570, z=-.568) 추후 해외로의 임상실습 참여 에 대하여 해외실습 참여자는 66.7%가 참여 의향이 있고, 원하지 않는 참여자는 없었으며 미참여자 40.9%는 참여의향이 없었으며 유의한 차이가 있었다(p<0.05). 해외 취업에 대하여 참여자는 76.2%, 미참여자는 19.2%가 관심을 가지고 있으며 유의한 차이가 있었다(p<0.05). 결론: 학생들의 해외실습 참여를 통해 실습 및 전공 만족도가 높아졌으며, 향후 해외실습 및 해외인턴십 프로그램 참여에 대한 긍정적인 의향을 갖고 있음을 확인하였다.

중추성 성조숙증 및 조기 사춘기 여아에서 성선자극호르몬 방출호르몬작용제의 용량에 따른 사춘기 억제 효과 비교 (A comparative study of the puberty suppression effect of gonadotropin-releasing hormone agonist in precocious or early puberty girls)

  • 심계식;배종우;양유정
    • Clinical and Experimental Pediatrics
    • /
    • 제51권6호
    • /
    • pp.634-639
    • /
    • 2008
  • 목 적 : 중추성 성조숙증 또는 조기 사춘기 소아에서 사춘기 진행의 억제를 위하여 사용하는 GnRH agonist의 적절한 용량에 대하여 논란이 많다. 따라서 치료의 표준화가 힘들고 치료에 대한 반응도 다양할 수밖에 없다. 본 연구는 중추성 성조숙증 또는 조기 사춘기 여아에서 GnRH agonist의 용량에 따른 사춘기 억제 효과를 비교하여 적당한 용량을 추정해보고자 하였다. 방 법 : 2006년 6월부터 2007년 5월까지 경희대학교 동서신의학병원 소아청소년과에서 조기 사춘기 혹은 성조숙증으로 진단받고 GnRH agonist를 투여하기로 한 여아 22명을 임의로 3군으로 나눠서 1군은 leuprolide acetate $70{\mu}g/kg$, 2군은 $90{\mu}g/kg$, 3군은 $110{\mu}g/kg$을 투여하였다. 치료 전, 치료 후 6개월에 채혈하여 황체화 호르몬, 난포자극호르몬, 에스트라디올, 프로게스테론을 검사하였고, 신장, 체중, 골 연령, 성성숙도의 변화를 평가하여 modified puberty suppression score를 구하여 억제된 경우는 2점 이하인 경우로 하였다. 각각의 군에서 역연령과 골연령의 평균은 Kruskal-Wallis test로 차이의 유무를 검정하였고, 억제가 된 경우와 되지 않은 경우의 수를 비교하여 two-by-K 교차분석(카이제곱 검정)을 시행하였다. 결 과 : 1군, 2군, 3군의 치료 전 역연령은 각각 $8.7{\pm}0.9$, $8.8{\pm}1.0$, $8.7{\pm}0.8$세, 골 연령은 $11{\pm}0.8$, $11{\pm}0.9$, $11{\pm}0.8$세, 신장표준편차점수는 $1.1{\pm}0.9$, $1.1{\pm}0.9$, $1.2{\pm}0.9$, 예측 성인키의 신장표준편차점수는 $-1.4{\pm}0.8$, $-1.4{\pm}1.1$, $-1.4{\pm}0.6$으로 의미 있는 차이는 없었다. 1군, 2군, 3군의 치료 전 혈중 황체화 호르몬은 각각 $3.0{\pm}2.9$, $3.0{\pm}2.3$, $3.0{\pm}3.4IU/L$, 에스트라디올은 각각 $1.5{\pm}1.0$, $1.4{\pm}0.9$, $1.6{\pm}1.0ng/dL$로 의미 있는 차이는 없었으며, 난포자극호르몬은 각각 $4.1{\pm}2.6$, $6.3{\pm}0.3$, $3.1{\pm}2.5IU/L$, 프로게스테론은 $33.9{\pm}17.1$, $30.6{\pm}14.7$, $35.8{\pm}14.8mg/dL$로 의미 있는 차이가 있었다(P<0.05). 1군, 2군, 3군 각각의 6개월 치료 후 신장표준편차점수의 변화는 $0.3{\pm}0.4$, $0.2{\pm}0.3$, $0.1{\pm}0.1$로서 1군과 2군 간에는 의미 있는 차이가 없었으나 3군과는 의미 있는 차이가 있었다(P<0.05). 1군, 2군, 3군의 치료 후 각각의 황체화 호르몬은 $0.5{\pm}0.3$, $0.4{\pm}0.3$, $0.3{\pm}0.3IU/L$, 난포자극호르몬은 $2.4{\pm}1.8$, $1.9{\pm}1.6$, $1.3{\pm}0.9IU/L$, 에스트라디올은 $0.9{\pm}0.8$, $0.9{\pm}0.8$, $0.9{\pm}0.9ng/dL$, 프로게스테론은 $19.5{\pm}8.7$, $18.0{\pm}7.7$, $16.9{\pm}7.2ng/dL$ 로서 치료 전과 비교하여 세 군에서 모두 의미 있게 감소하였으며 특히 난포자극호르몬과 프로게스테론은 다른 군에 비하여 3군에서 더욱 의미 있게 감소하였다(P<0.05). 사춘기 억제가 된 경우는 1군 7명중 4명, 2군 7명중 5명, 3군 8명중 8명이었고, 억제가 안 된 경우는 1군과 2군에서 각각 2명씩으로 3군에서 의미 있게 억제되는 경우가 많았다(P<0.05). 3군의 2명에서 치료 초기 주사 부위의 경미한 동통 외에 특이한 부작용은 없었다. 결 론 : 조기 사춘기 여아에서 사춘기의 진행을 막기 위해서는 성선 자극 호르몬이 보다 억제 될 수 있도록 고용량의 GnRH agonist의 투여가 필요하며, 적절한 용량에 대한 보다 많은 수의 연구가 필요하다고 사료된다.