• Title/Summary/Keyword: Wall type apartment house

Search Result 20, Processing Time 0.027 seconds

The Success Factors of Scheduling Using the TACT Technique in Wall Type Apartment House Construction (벽식(壁式) 아파트의 택트공정(工程)계획의 성공요인 분석에 관(關)한 연구(硏究))

  • Kim Joon-Ho;Kim Gwang-Hee;Cho Hyung-Keun
    • Journal of the Korea Institute of Building Construction
    • /
    • v.6 no.1 s.19
    • /
    • pp.79-86
    • /
    • 2006
  • Recently, the construction companies show lots of interest in reducing the construction duration of apartment housing project in Korea. Therefore, the purpose of this study is to investigate the success factors of scheduling using the TACT technique in wall type apartment house construction for managing the construction schedule effectively. For appling the tact scheduling technique to wall type apartment house construction, the success factors can be summarized as follows : (1) zoning the horizontal and vortical work area properly, (2) preparing the flow chart of finishing works, (3) minimizing the undefined activity like chipping off the concrete wall, (4) reordering the construction activities for keeping up the continuity of works in winter season, (5) dividing the amount of work for minimizing the delay time of any activity, etc.

The Numerical Analysis of Heavy Weight Impact Noise for an Apartment House (공동주택 모델링을 통한 중량충격음 예측에 관한 연구)

  • Hwang, Jae-Seung;Moon, Dae-Ho;Park, Hong-Gun;Hong, Sung-Gul;Hong, Geon-Ho
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.19 no.2
    • /
    • pp.162-168
    • /
    • 2009
  • In this study, numerical analysis is performed to investigate the sound radiation characteristics of an apartment house according to the type of the slab system. In order to satisfy the boundary condition of the apartment house, the whole floor is modelled with FEM model for three different structural system: wall, RC, flat slab system. From the analytical results, it is shown that heavy weight floor impact noise of wall type slab is larger than that of the other slab systems and the noise radiated from the wall have great effect on the sound pressure level. The results also show that the vibration energy of RC or flat slab system is widely distributed over the whole slab, which is main reason that the noise induced by the slab systems is reduced in comparison with wall slab system.

Prediction of Heating Energy Saving Rate on the Window Type-Focus on the Apartment House (창호 구성 요소에 따른 난방에너지 절감율 예측에 관한 연구-공동주택을 중심으로)

  • Kim, Kyung-Ah;Moon, Hyeun-Jun;Yu, Ki-Hyung
    • Journal of the Korean Solar Energy Society
    • /
    • v.33 no.6
    • /
    • pp.54-61
    • /
    • 2013
  • This is study on the glazing performance of the apartment house to predict energy saving rate when the early design stage by calculating heating load. there are various factors of the window type in apartment building to save energy such as window's U-value, SC or SHGC, window wall ration, frame factor, sunshade coefficient and so on. In this study, we analyzed the heating load focused on the U-value, SC and window wall ration using variable heating degree days method for a small and middle size units $59m^2$, $84m^2$, respectively. Each cases were calculated heating load of the real models compared to standard model to predict energy saving rate. From those cases it was drew the conclusion that were window's U-value, SC and window wall ration for the small and middle size units to expect 10% energy saving rate at least.

The numerical analysis. of heavy weight impact noise for an apartment house (공동주택 모델링을 통한 중량충격음 예측에 관한 연구)

  • Hwang, Jae-Seung;Moon, Dae-Ho;Yoon, Young-Bae;Hong, Geon-Ho;Park, Hong-Gun;Hong, Sung-Gul
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2008.11a
    • /
    • pp.527-532
    • /
    • 2008
  • In this study, numerical analysis is performed to investigate the sound radiation characteristics of an apartment house according to the type of the slab system. In order to satisfy the boundary condition of the apartment house, the whole floor is modelled with FEM model for three different structural system: wall, RC, flat slab system. From the analytical results, it Is shown that heavy weight floor impact noise of wail type slab is larger than that of the other slab systems and the noise radiated from the wall have great effect on the sound pressure level. The results also show that the vibration energy of RC or flat slab system is widely distributed over the whole slab, which is main reason that the noise induced by the slab systems is reduced in comparison with wail slab system.

  • PDF

A Study on Indoor Thermal Environment in an Tower Type Apartment House at Tropical Nights (여름철 열대야 발생시 탑상형 아파트의 실내온열환경에 대한 연구)

  • Chang, Hyun-Jae;Kim, Hyung-Jin
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.22 no.1
    • /
    • pp.20-25
    • /
    • 2010
  • In this study, As a basic research for improving indoor thermal environment at tower type apartment houses, specifications of heat storage and heat emission in the structures of apartment houses were investigated, and the ratio of indoor and outdoor air velocity at tower type apartment house was examined, too. Indoor temperature at night time was higher than outdoor air temperature because heat emission from the structure of wall, ceiling and floor those are constructed by use of reinforced concrete which has large heat capacity. The ratio of indoor and outdoor air velocity was lower than 0.1 and this was caused by the plan of tower type apartment house. PMV was in the range of 0.3~1.9, and was about 1.0 (it means slightly warm) at 10 : 00 p.m.. To improve indoor thermal environment in summer season at tower type apartment houses, it needs more investigation on specifications of heat storage and heat emission in the structure including winter season, and on the improvement of the ratio of indoor and outdoor air velocity.

Post Evaluation on the Constructibility of the Lightweight Wall in Long Life Housing through Interview Survey (설문조사를 통한 장수명주택의 경량벽체 시공성 사후평가)

  • Lee, Hak-Ju
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2014.05a
    • /
    • pp.188-189
    • /
    • 2014
  • Recently, structural system of apartment building is changing from wall type to column type to accommodate various life styles of residents in Korea. Reinforced-concrete bearing wall structures have been mainly used in apartment construction since 1980's. It is impossible to remove the bearing wall in case of remodeling a house, so that the lightweight wall is needed to apply to the column type structure of the Long Life Housing. Therefore, the purpose of this study is to evaluate the construction performance of the wall. Constructibility reviews are performed throughout interview survey from builders who charge with managing the construction of the lightweight wall in field. This paper present that constructor prefer the bearing wall rather than the lightweight wall because of the schedule delay, difficulty of management, and lack of skilled labor. The results indicate what we should improve on the lightweight wall from now on.

  • PDF

Energy Consumption on Balcony Remodeling Type in an Apartment House (공동주택에서 발코니 확장형이 에너지소비에 미치는 영향)

  • Hyun, Jong-Hun;Choi, Moo-Hyuck;Kim, Ji-Yeon;Park, Hyo-Soon
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.1406-1411
    • /
    • 2008
  • The percentage of apartment houses in residential buildings has increased every year, and it result in higher energy consumption of residential buildings. After the house law could be amended to legalize the remodeling of the balcony, buyers and contractors prefer to choose the balcony remodeling type when they choose a house for installment sale. Many construction companies design an apartment house considering balcony remodeling. So, this paper compares the balcony remodeling type with the basic type(prior to remodeling balcony) by using the building energy rating system tool. The balcony remodeling type consumes heating energies more than the basic type, and is unable to receive high rating. If the balcony is remodeled, it is required to improve the performance of wall and window and reduce the area of remodeling balcony.

  • PDF

A Field Measurement Study on Heat Storage/Emission Characteristics of Tower Type Apartment Structures in Winter Season (겨울철 난방시 탑상형 아파트 구조체의 축·방열 특성에 대한 현장측정 연구)

  • Chang, Hyun-Jae;Cho, Keun-Je
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.24 no.2
    • /
    • pp.190-195
    • /
    • 2012
  • In this study, as a complementary study of the former study on indoor thermal environment in a tower type apartment house at tropical nights, a field measurement was conducted in winter season. Mainly, characteristics of heat storage and heat emission in apartment structures, in this study, were investigated. As results, indoor air temperature was changed in the range of $22.5^{\circ}C{\pm}1.0^{\circ}C$, and followed not the change of outdoor air temperature but the changed pattern of floor surface temperature. Wall surface temperature was unresponsive to the change of floor surface temperature compared with the change of indoor air temperature because wall structure was composed of concrete which has large heat capacity, and was changed in the range of $22.3^{\circ}C{\pm}0.6^{\circ}C$. Heat was stored continuously into the structures of wall and ceiling through the measurement term. and this means that a large heat capacity of the apartment structure acts as a disadvantage in winter season, too. As a total review of the study with the former study, a large heat capacity of the apartment structure acts against indoor thermal comfort in winter season as well as in summer season.

A Study on the User's Evaluation for the Visual Types of Virtual Model House (가상모델하우스의 유형에 따른 사용자 평가에 관한 연구)

  • Ha, Ji-Min;Park, Soo-Been
    • Korean Institute of Interior Design Journal
    • /
    • v.20 no.5
    • /
    • pp.160-169
    • /
    • 2011
  • In Korea, the construction company has provided houses through apartment sales system. Residents have obtained a variety of information about their future house by visiting a sample house called "the model house" before they purchase home. Advanced technology such as web-based VOD or Virtual Model in recent years has gradually replaced those built environment. In 2009, the Ministry of Land, Transport and Maritime Affairs announced the restraint to the construction of sample houses. Instead, they highly recommended a Virtual Model House as an alternative solution. This study aimed to propose how to design the user-oriented virtual model house through the experiment and survey research. The 3D virtual model house of 85m$^2$ apartment was built and presented by two types (Type A: Bird's Eye View, Type B: Walk through View) on the web page. The subjects evaluated presence, spatial perception and cognition, and usability of each type after exploring them. The results are as follows. (1) The subjects' evaluation of presence showed Type B has more negative effects than Type A such as feeling dizzy or tired even if their values were not so high. (2) The subjects perceived and cognized both types of virtual model house more realistic for the expression of volume of space, the size of opening, and the arrangement of furniture than that of wall finishes and materials. (3) The usability of Type A was significantly higher than that of Type B.

A Study on the Ventilation Performance and Fire Characteristics with Different Types of Openings in External Wall of One Side Corridor Type Apartment (편복도형 아파트의 복도 외벽체 개구부 형태에 따른 환기성능 및 화재특성에 관한 연구)

  • Ko, Myeong Jin;Choi, Do Sung;Do, Jin Seok
    • KIEAE Journal
    • /
    • v.10 no.5
    • /
    • pp.87-93
    • /
    • 2010
  • The objective of this study is to verify the safety in case of fire and change of residential environment for different wall construction approaches in a stairways apartment house. In order to confirm that case_1, which is current case that most of wall is opened and the case 2, which upper part of wall is limitedly opened are compared and analyzed based on simulations of fire, escape and natural ventilation performance. The analysis reveals that possible escape time for case 1 was more than 600 seconds and for case 2 was 195 seconds. Since the escape times for both cases were over 128 seconds, it would be reasonable to assume that every resident would escape. The simulation results on natural ventilation performance shows the air change per hour of case 1 and case 2 were .19n/h and .16n/h and there was 1.2 times difference. However, the difference was too insignificant and it could be seen as that different approaches on wall construction would not significantly influence on natural ventilation performance.