• 제목/요약/키워드: Wall thickness

검색결과 1,558건 처리시간 0.032초

Cell Wall Structure of Various Tropical Plant Waste Fibers

  • Abdul Khalil, H.P.S.;Siti Alwani, M.;Mohd Omar, A.K.
    • Journal of the Korean Wood Science and Technology
    • /
    • 제35권2호
    • /
    • pp.9-15
    • /
    • 2007
  • A comparative study of the structure and organization of the primary and secondary walls in different types of tropical plant waste fibers was carried out using transmission electron microscopy (TEM). The thickness of each layer was also measured using Image Analyzer. TEM micrographs haveconfirmed that cell wall structure of all six types of tropical plant waste fibers (empty fruit bunch, oil palm frond, oil palm trunk, coir, banana stem and pineapple leaf) has the same ultrastructure with wood fibre. The fibers consisted of middle lamella, primary and thick secondary wall with different thickness for different types of fibers. The secondary wall was differentiated into a $S_1$ layer, a unique multi-lamellae $S_2$ layer, and $S_3$ layer.

벽체의 축력 증진 방안 연구 (Retrofitting of Reinforced Concrete Wall to Increase Axial Load Capacity)

  • 신영수;홍기섭;최완철;홍영균;김상준
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1997년도 가을 학술발표회 논문집
    • /
    • pp.673-678
    • /
    • 1997
  • The main structural system of domestic apartments is the wall-slab system. In such structures, the lack of material strength of wall affects severely on the safety of structures. It is fond frequently that the wall in the apartment structures has lower strength in concrete than the specified. This paper presents the retrofitting method of the reinforced concrete wall with low concrete strength. The tests are performed to investigate the structural behavior and the effects of external reinforcing and thickness increasing on the axial load capacity of walls. Six specimens are tested. As the test results, the external reinforcing method is less effective than thickness increasing method.

  • PDF

초음파 Pulse-echo 방법에 의한 액체막 두께 측정 (Liquid Film Thickness Measurement by An Ultrasonic Pulse Echo Method)

  • Jong Ryul Park;Jong-Ryul Park;Se Kyung Lee
    • Nuclear Engineering and Technology
    • /
    • 제17권1호
    • /
    • pp.25-33
    • /
    • 1985
  • 경수형 원자로의 운전과 안전성 해석을 위해 열수력학적 모형을 개발하는 것이 하나의 중요한 과제이다. 특히, 2상류의 열수력학적 모형을 개발하기 위해서는 기포율, 액체막 두께, 유동 영역과 같은 중요한 변수들을 실제로 측정한 값이 필요하다. 본 연구의 목적은 초음파 Pulse-echo 방법을 이용하여 액체 두께를 실험적으로 측정하고, 이론치와 비교 분석하여 (1) 관벽의 두께, (2) 초음파의 주파수, (3) 관벽의 재질 등이 액체막 두께 측정에 미치는 영향을 분석하는 데에 있다. 평판협 (Plate-type)과 관(Tube-type)으로 된 시험관을 이용하여 수평으로 놓인 물-공기의 층류계 (a horizontal airwater stratified system)를 만들어 일련의 액체막 두께 측정 실험을 수행하였다. 시험관의 벽 두께와 초음파 Pulse-echo 의 주파수를 변화시키면서 액체막 두께 측정을 반복하였다. 또한, 관벽의 acoustic impedance가 초음파 Pulse-echo 방법으로 액체막 두께를 측정할 때, 어떠한 영향을 주는가도 아울러 파악하기 위해서 스텐레스 강과 폴리아크릴 (Polyacrylate) 등 재질이 다른 두 개의 격리봉 (Standonff rod) 을 사용하여 액체막 두께를 측정하였다. 이렇게 하여 얻은 실험 결과를 제시하고 실제로 측정한 액체막 두께와 비교 분석하였다.

  • PDF

전단간섭계를 이용한 직관시험편의 결함 깊이 측정 (Defect Depth Measurement of Straight Pipe Specimen Using Shearography)

  • 장호섭;김경석
    • 비파괴검사학회지
    • /
    • 제32권2호
    • /
    • pp.170-176
    • /
    • 2012
  • 원자력 산업에 있어서 파이프의 감육결함은 수명평가 및 안전평가에 막대한 손실을 발생 할 수 있다. 비파괴검사 기법을 이용하여 변형, 진동, 결함 평가를 수행하고 있지만, 넓은 면적의 결함을 평가하는 기법이 적으며, 시간이 오래 걸리는 단점이 있다. 원자력 발전소의 2차계통에서 주로 사용되는 탄소강 배관을 대상으로 내부에 인공 감육결함을 가공하고 두께를 서로 다르게 하여 제작하여 Shearography를 이용하여 감육결함부의 변형을 측정하였다. 또한 광 계측을 통하여 변형, 진동, 결함 평가뿐만 아니라 압력용기의 결함깊이를 정량적으로 평가하고자 한다. 본 논문은 전단간섭계를 이용하여 파이프의 내부 감육 결함을 측정하고, 압력에 따른 변형을 제시한 기법을 이용하여 정량적인 결함의 잉여두께를 평가하고자 한다. 변형량을 이용하여 잉여두께 예측결과 실제 결함깊이와 약 7%의 오차로 신뢰성을 확보하였으며, 압력에 따른 변형량과 잉여두께의 DB구축을 통하여 원전 배관의 감육부 건전성 평가에 활용될 수 있을 것이다. 따라서, 본 연구에서 제안하는 압력용기 결함깊이 측정법은 원자력배관의 감육결함 예측 및 건정성 평가 기술 개발 등 이론과 실험이 결함된 기초연구로서 압력용기의 안정성, 건전성, 보수성을 증진시킬 수 있는 기반확립에 기여할 것으로 기대한다.

LPG 충전장치의 강도안전성에 관한 연구 (A Study on the Strength Safety of LPG Fuelling Nozzle)

  • 김청균
    • 한국가스학회지
    • /
    • 제22권2호
    • /
    • pp.72-77
    • /
    • 2018
  • 본 연구에서는 볼밸브와 긴 실린더 튜브로 구성된 LPG 충전장치의 강도안전성에 대한 FEM 해석결과를 제시하고 있다. LPG 충전장치의 강도안전성 해석을 위해 1.7~3.5mm의 벽면 두께를 갖는 볼밸브와 긴 실린더 튜브에 0.5~3.5MPa의 가스압력을 공급하였다. 1.7mm 벽면 두께를 갖는 볼밸브에 3.5MPa의 가스압력을 공급하였을 때 발생한 von Mises 최대응력은 25.4MPa이고, 이 값은 황동소재 항복강도의 25.9%에 해당한다. 그리고 1.7mm 벽면 두께를 갖는 긴 실린더 튜브에 3.5MPa의 가스압력을 공급하였을 때 발생한 von Mises 최대응력은 23.7MPa이고, 이 값은 동일한 조건으로 해석한 볼밸브에 비해 6.7%나 더 안전한 것으로 나타났다. 긴 실린더 튜브의 벽면 두께를 2.0mm로 증가시켰을 경우 발생한 von Mises 최대응력 20.2MPa은 1.7mm의 벽면 두께를 갖는 같은 실린더 튜브에 비해 14.8%나 더 안전하였다. 따라서 본 연구에서는 볼밸브와 실린더 튜브의 강도안전성을 확보하기 위해서는 벽면의 두께를 1.7~2.0mm 정도로 최적화된 LPG 충전장치가 바람직하다.

골조-전단벽 구조에서 전단/코어벽의 Shear Lag 현상 (Shear Lag Phenomenon in Shear/Core Wall of Wall-Frame Structures)

  • 이은진;이강건;이리형
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 2001년도 봄 학술발표회 논문집
    • /
    • pp.215-222
    • /
    • 2001
  • This study investigates the shear lag phenomenon existing in the shear wall of the wall-frame structure. Elastic analysis of such structures is carried out using a 3-D frame analysis program. The structural parameters governing the shear lag phenomenon are wall height and thickness. The analysis shows that the overturning moment due to external lateral load is resisted by both of the shear/core wall and the external frame. Severe unstable stresses are identified in height ratio of about 0.7 The taller or thinner wall shows the smaller shear lag phenomenon.

  • PDF

Preparation and Optical Characterization of Mesoporous Silica Films with Different Pore Sizes

  • Bae, Jae-Young;Choi, Suk-Ho;Bae, Byeong-Soo
    • Bulletin of the Korean Chemical Society
    • /
    • 제27권10호
    • /
    • pp.1562-1566
    • /
    • 2006
  • Mesoporous silica films with three different pore sizes were prepared by using cationic surfactant, non-ionic surfactant, or triblock copolymer as structure directing agents with tetramethylorthosilicate as silica source in order to control the pore size and wall thickness. They were synthesized by an evaporation-induced self-assembly process and spin-coated on Si wafer. Mesoporous silica films with three different pore sizes of 2.9, 4.6, and 6.6 nm and wall thickness ranging from $\sim$1 to $\sim$3 nm were prepared by using three different surfactants. These materials were optically transparent mesoporous silica films and crack free when thickness was less than 1 m m. The photoluminescence spectra found in the visible range were peaked at higher energy for smaller pore and thinner wall sized materials, consistent with the quantum confinement effect within the nano-sized walls of the silica pores.

깊이가 깊은 사출 금형의 새로운 측벽 두께 설계에 관한 연구 (A Study on the Novel Prediction of Mold Wall Thickness for a Deep Depth Injection Mold)

  • 황수진;류민영
    • 소성∙가공
    • /
    • 제17권7호
    • /
    • pp.528-533
    • /
    • 2008
  • Cavity in the mold is exposed to high pressure during injection molding operation. Injection molded articles with deep depth are often demanded as design variety increases. Subsequently mold becomes weak and deformation increases as the mold depth increases. Thus the injection molds for deep depth articles should be designed to hold out high pressure or stress concentration and large deformation. Through this study, equation for mold design was examined and suggested novel method to determine equation for mold design with deep depth. Novel equation developed in this study was modified from beam theory considering cantilever and two points bending situation while previous equation was modified from just cantilever bending situation. The validity of novel equation was verified through computer simulations for various mold side and wall thickness.

OPTIMUM PERFORMANCE AND DESIGN OF A RECTANGULAR FIN

  • Kang, H.S.
    • International Journal of Automotive Technology
    • /
    • 제8권6호
    • /
    • pp.705-711
    • /
    • 2007
  • A rectangular fin with a fluid in the inside wall is analyzed and optimized using a two-dimensional analytical method. The influence of the fluid convection characteristic number in the inside wall and the fin base thickness on the fin base temperature is listed. For the fixed fin volumes, the maximum heat loss and the corresponding optimum fin effectiveness and dimensions as a function of the fin base thickness, convection characteristic numbers ratio, convection characteristic number over the fin, fluid convection characteristic number in the inside wall, and the fin volume are represented. One of the results shows that both the optimum heat loss and the corresponding fin effectiveness increase as the fin base thickness decreases.

최신 설계규정에 의한 심해 해저관로 두께의 기계적 설계 (Mechanical Design of Deepwater Pipeline Wall Thickness Using the Recent Rules)

  • Han-Suk Choi
    • 한국해양공학회지
    • /
    • 제16권6호
    • /
    • pp.65-70
    • /
    • 2002
  • This paper presents a mechanical design of the deepwater pipeline wall thickness using the recent design rules. Characteristics and limitations of the new codes were identified through a case study design in the Gulf of Mexico. In addition to the ASME, API, and DVD codes, the code of federal regulations (CFR) was also utilized in the design. It was found that conservatism still exists within the collapse prediction for water depth greater than 1500m. Comparision of the results from DNV and API codes were presented.