• 제목/요약/키워드: Wall subcooling

검색결과 44건 처리시간 0.021초

수평관에서 이원 혼합냉매의 응축 열전달계수 (Condensation Heat Transfer Coefficients of Binary Refrigerant Mixtures on a Horizontal Smooth Tube)

  • 김경기;서강태;정동수
    • 설비공학논문집
    • /
    • 제12권12호
    • /
    • pp.1049-1056
    • /
    • 2000
  • In this study, condensation heat transfer coefficients(HTCs) of 2 nonazeotropic refrigerant mixtures of HFC32/HFC134a and HFC134a/HCFC123 at various compositions were measured on a horizontal smooth tube. All data were taken at the vapor temperature of 39$^{\circ}C$ with a wall subcooling of 3~8K. Test results showed that HTCs of tested mixtures were 11.0~85.0% lower than the ideal values calculated by the mass fraction weighting of the pure components HTCs. Thermal resistance due to the diffusion vapor film was partly responsible for the significant reduction of HTCs with these nonazeotropic mixtures. The measured data were compared against the predicted ones by Colburn and Drew\`s film model and a good agreement was observed.

  • PDF

수직 벽면에서 과냉 핵비등 시 열유속 분배에 관한 실험적 연구 (Experimental Study on Heat Flux Partitioning in Subcooled Nucleate Boiling on Vertical Wall)

  • 송준규;박준석;정샛별;김형대
    • 대한기계학회논문집B
    • /
    • 제38권6호
    • /
    • pp.465-474
    • /
    • 2014
  • 본 연구에서는 비등 열유속 분배 모델의 예측 정확성을 검증하기 위하여 수직평판 자연대류 과냉 비등에서 기화, 급랭, 및 단상대류 열전달 기구에 대한 열유속 분배 특성을 실험적으로 조사하였다. 비등 열유속의 분배를 위해 적외선 열화상 기법과 전반사 가시화 기법을 동기화하여 비등 표면의 열유속 분포와 액상-기상 분포를 동시에 측정하여 분석하는 실험을 수행하였다. 실험은 대기압 조건에서 과냉도 $10^{\circ}C$를 가지는 물을 이용하여 수행하였으며, 벽면과열도 $12^{\circ}C$ 및 평균 열유속 $283kW/m^2$ 조건에 대한 실험 결과를 분석에 활용하였다. 실험을 통해 획득된 열유속 분배 결과는 상관식을 이용한 예측 결과와 큰 차이를 보였으며, 기포이탈직경과 기포이탈 시 주변의 과열액체층이 함께 뜯겨져 나가는 효과를 고려한 기포영향인자가 차이를 만드는 주요 원인들로 파악되었다.

응축전열관 외부형상 변화에 따른 HFC134a의 열전달 실험 (The Experimental Study on the Heat Transfer of HFC134a for Condensation Tubes with Various Enhanced Surfaces)

  • 박찬형;이영수;정진희;강용태
    • 설비공학논문집
    • /
    • 제18권8호
    • /
    • pp.613-619
    • /
    • 2006
  • The objectives of this paper are to study the characteristics of heat transfer for enhanced tubes (19.05 mm) used in the condenser with high saturation temperatures and to provide a guideline for optimum design of a condenser using HFC134a. Three different enhanced tubes are tested at a high saturation temperature of $59.8^{\circ}C$ (16 bar); a low-fin and three turbo-C tubes.. The refrigerant, HFC134a is condensed on the outside of the tube while the cooling water flows inside the tube. The film Reynolds number varies from 130 to 330. The wall subcooling temperature ranges from $2.7^{\circ}C$ to $9.7^{\circ}C$. This study provides experimental heat transfer coefficients for condensation on the enhanced tubes. It is found that the turbo-C(2) tube provides the highest heat transfer coefficient.

수평관에서 R245fa의 응축 열전달계수 (Condensation Heat Transfer Coefficients of R245fa on a Plain Tube)

  • 심윤보;박기정;정동수;김종성
    • 설비공학논문집
    • /
    • 제19권8호
    • /
    • pp.555-562
    • /
    • 2007
  • In this study, condensation heat transfer coefficients (HTCs) of R22, R134a, R245fa and R123 are measured on a horizontal plain tube. All data are taken at the vapor temperature of $39^{\circ}C$ with a wall subcooling temperature $3-8^{\circ}C$. Test results show the HTCs of newly developed alternative low vapor pressure refrigerant, R245fa, on a plain tube are 9.5% higher than those of R123 while they are 3.3% and 5.6% lower than those of R134a and R22 respectively. Nusselt's prediction equation for a plain tube underpredicts the data by 13.7% for all refrigerants while a modified equation yielded 5.9% deviation against all data. From the view point of environmental safety and condensation heat transfer, R245fa is a long term good candidate to replace R123 used in centrifugal chillers.

상변화물질을 이용한 축열조에서 열전달현상에 관한 연구 - 수직원통관 내에서 응고 열전달 - (A study of heat transfer with Phase Change Material in heat storage system - Inward freezing in the vertical cylinder -)

  • 이채문;임장순
    • 태양에너지
    • /
    • 제13권2_3호
    • /
    • pp.53-64
    • /
    • 1993
  • 본 연구는 용융된 파라핀을 채운 수직원관 내의 상변화물질의 초기온도와 수직원관의 벽면온도를 변화시켰을때 관 내에서 일어나는 열전달현상을 다루었다. 자연대류의 효과는 초기과열된 액상영역 내에서 응고초기 짧은 시간에 걸쳐 일어났고, 그 후 전도열전달이 paraffin 전 영역을 지배하였다. 실험에서 관찰한 응고 형태는 상부표면에서 밀도 증가에 의한 수축공간이 발생하였으며, 그 공간의 크기는 냉각이 진행됨에 따라 증가하였다. 자연대류가 끝나자. 상경계면 상에서 수지상 결정과 mush-zone이 발견되었다. 액상 paraffin의 초기과열은 실험 전반부의 응고질량과 응고두께를 감소시키는 경향을 보였으며, 초기액상과열도와 벽면 과냉도가 큰 경우에 크게 나타났다.

  • PDF

신냉매 R1234yf의 외부 응축 열전달계수 (External Condensation Heat Transfer Coefficients of R1234yf)

  • 박기정;이철희;강동규;정동수
    • 설비공학논문집
    • /
    • 제22권6호
    • /
    • pp.345-352
    • /
    • 2010
  • In this study, external condensation heat transfer coefficients(HTCs) of R134a and R1234yf are measured on a plain, low fin, and Turbo-C tubes at the saturated vapor temperature of $39^{\circ}C$ with the wall subcooling of $3{\sim}8^{\circ}C$. R1234yf is a new alternative refrigerant of low greenhouse warming potential for replacing R134a which is one of the greenhouse gases controlled by Kyoto protocol and is used extensively in mobile air-conditioners. Test results show that the external condensation HTCs of R1234yf are very similar to those of R134a for all three surfaces tested. For the application of condensation heat transfer correlations to the design of condensers charged with R1234yf, thorough property measurements are needed for R1234yf in the near future.

수직 동심 환형관 내부유동에서 과냉 유체의 비등 시작 열유속에 관한 표면 볼록 곡률의 영향 (Effect of Convex Surface Curvature on the Onset of Nucleate Boiling of Subcooled Fluid Flow in Vertical Concentric Annuli)

  • 변정환;이승홍
    • 대한기계학회논문집B
    • /
    • 제26권11호
    • /
    • pp.1513-1520
    • /
    • 2002
  • Effect of Convex Surface Curvature on the Onset of Nucleate Boiling of Subcooled Fluid Flow in Vertical Concentric Annuli An experimental study has been carried out to investigate the effect of the transverse convex surface curvature of core tubes on heat transfer in concentric annular tubes. Water is used as the working fluid. Three annuli having a different radius of the inner cores, Ri=3.18mm, 6.35mm, and 12.70mm with a fixed ratio of Ri/Ro=0.5 are used over a range of the Reynolds number between about 40,000 and 80,000. The inner cores are made of smooth stainless steel tubes and heated electrically to provide constant heat fluxes throughout the whole length of each test section. Experimental result shows that heat flux values on the onset of nucleate boiling of the smaller inner diameter model is much higher than that of the larger size test model.

Condensation Heat Transfer Coefficients of Flammable Refrigerants on Various Enhanced Tubes

  • Park Ki-Jung;Jung Dongsoo
    • Journal of Mechanical Science and Technology
    • /
    • 제19권10호
    • /
    • pp.1957-1963
    • /
    • 2005
  • In this study, external condensation heat transfer coefficients (HTCs) of six flammable refrigerants of propylene (RI270), propane (R290), isobutane (R600a), butane (R600), dimethylether (RE170), and HFC32 were measured at the vapor temperature of $39^{\circ}C$ on a 1023 fpm low fin and Turbo-C tubes. All data were taken under the heat flux of $32\~116\;and\;42\~142kW/m^2$ for the low fin and Turbo-C tubes respectively. Flammable refrigerants' data obtained on enhanced tubes showed a typical trend that external condensation HTCs decrease with increasing wall subcooling. HFC32 and DME showed up to $30\%$ higher HTCs than those of HCFC22 due to their excellent thermophysical properties. Propylene, propane, isobutane, and butane showed similar or lower HTCs than those of HCFC22. Beatty and Katz' correlation predicted the HTCs of the flammable refrigerants obtained on a low fin tube within a mean deviation of $7.3\%$. Turbo-C tube showed the best performance due to its 3 dimensional surface geometry for fast removal of condensate.

수평관에서 R22 대체냉매 및 R134a의 포화증기 온도변화에 따른 외부 응축 열전달계수에 관한 연구 (External Condensation Heat Transfer Coefficients of R22 Alternative Refrigerants and R134a According to the Saturated Vapor Temperature Change on a Smooth Tube)

  • 유길상;황지환;박기정;정동수
    • 설비공학논문집
    • /
    • 제17권8호
    • /
    • pp.729-735
    • /
    • 2005
  • In this study, external condensation heat transfer coefficients (HTCs) were measured on a horizontal smooth tube at the saturated vapor temperature of $30^{\circ}C,\;39{\circ}C,\;and\;50^{\circ}C$ for R22, R410A, R407C, and R134a with the wall subcooling of $3\~8^{\circ}C$. The HTCs of all refrigerants are the highest at $30^{\circ}C,\;39{\circ}C,\;and\;50^{\circ}C$ in order. This trend is due to its excellent thermodynamic properties of the liquid phase. The measured data of HTCs were compared with the calculated ones by Nusselt's equation for a smooth tube. Measured HTCs of R22, R134a, R410A are $4.2\~7.5\%$ higher than prediction respectively while those of R407C are $15.6\~28.9\%$ lower than the prediction.

열전달 촉진관에서 CFC-11 및 CFC-12 대체냉매의 응축 열전달 특성 연구 (Condensation heat transfer characteristics of alternative refrigerants for CFC-11, CFC-12 for enhanced tubes)

  • 조성준;황수민;정동수;김종보
    • 설비공학논문집
    • /
    • 제10권5호
    • /
    • pp.569-580
    • /
    • 1998
  • In this study, condensation heat transfer coefficients(HTCs) of a plain tube, low fin tube, and Turbo-C enhanced tube for CFC-11, HCFC-123, CFC-12, HFC-l34a are measured and compared against each other. All data are taken at the vapor temperature of 39$^{\circ}C$ with a wall subcooling temperature 3~8$^{\circ}C$. Test results show that HTCs of a low vapor pressure refrigerant, HFC-123, for a plain, low fin, and Turbo-C tubes are 10.5~20.5%, 8.2~12.2%, 16.5~19.2% lower than those of CFC-11, respectively. On the other hand, HTCs of a medium vapor refrigerant, HFC-l34a, for a plain, low fin, and Turbo-C tubes are 20.6~31.8%, 0.0~8.0%, 13.2~20.9% higher than those of CFC-12, respectively. For all refrigerants tested, HTCs of Turbo-C tube are the highest among the three tubes showing almost 8 times increase in HTCs as compared to those of a plain tube. Nusselt's prediction equation for a plain tube yielded 12% deviation for all plain tube data while Realty and Katz's prediction equation for a low fin tube yielded 20% deviation for all low tube data.

  • PDF